Chemical Analysis Problem

Similar documents
CHAPTER CHROMATOGRAPHIC METHODS OF SEPARATIONS

OPTIMISATION OF SOLID PHASE MICROEXTRACTION (SPME) CONDITIONS FOR HEADSPACE ANALYSIS OF ORGANOPHOSPHATE PESTICIDES IN WHOLE BLOOD

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples

What type of samples are common? Time spent on different operations during LC analyses. Number of samples? Aims. Sources of error. Sample preparation

Chapter 23 Introduction to Analytical Separations

Open Column Chromatography, GC, TLC, and HPLC

Chromatography. writing in color

Application of Bio-SPME for the Enrichment of Illicit Phenethylamine and Cathinone Compounds from Biological Samples

Chromatography. Mrs. D. MEENA MPharm PA & QA KTPC

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

Shodex TM ODP2 HP series columns

Solid Phase Micro Extraction (SPME) of Opiates from Urine: Coupling SPME and DESI-MS/MS Detection

Determination of Volatile Substances Proof of Food Adulteration

Detection of 9-tetrahydrocannabinol ( 9-THC) in human urine by Solid Phase Extraction and HPLC.

CHROMATOGRAPHY. The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments.

Chromatography: Thin-Layer Chromatography (TLC) & Column Chromatography

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)

Chapter 27: Gas Chromatography. Principles Instrumentation Detectors Columns and Stationary Phases Applications

Principles of Gas- Chromatography (GC)

CHEMISTRY Unit 3, Area of Study 1: Chemical Analysis

Introduction to Chromatography

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Chapter content. Reference

ChromTech options for PAL systems

Chromatographic Separation

DEFINITION CHROMATOGRAPHY

Ch24. Gas Chromatography (GC)

Hints for Strong Ion Exchange Resins

Sample Prep Options for GC users

Quad-Z 215 with Disposable Tips: Implementing the Use of ZipTips for the Purification of Biological Samples

RediSep Rf C18 Flash Column Loading Techniques

DEHYDRATION OF ALCOHOLS-GAS CHROMATOGRAPHY

Chromatography. What is Chromatography?

CfE Higher Chemistry. Unit 3: Chemistry in Society. Chemical Analysis as part of quality control

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

SPE Columns. Solid Phase Extraction. SPE Columns

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Applications and Properties of New Polymeric Mixed Mode Cation Exchange Chromatography Media

PHYSICAL CONSTANTS: MELTING POINTS, BOILING POINTS, DENSITY

Solutions. Experiment 11. Various Types of Solutions. Solution: A homogenous mixture consisting of ions or molecules

The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction

Chromatography. Gas Chromatography

Column Liquid Chromatography Experiment Adapted for Use in Secondary Schools

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

Chromatography Lab # 4

2501 High Performance Liquid Chromatography

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

High Performance Liquid Chromatography (HPLC)

DATES: LAB: Liquid Chromatography Separation of Grape Kool-Aid

anthracene Figure 1: Structures of Selected Polyaromatic Hydrocarbons (PAHs)

CHROMATOGRAPHY AND MASS SPECTROMETER

Adsorption (Ch 12) - mass transfer to an interface

Characterization of Carbon SPE for the Extraction of Polar Analytes

AYOUB ET AL.: JOURNAL OF AOAC INTERNATIONAL VOL. 85, NO. 6,

Option D: Medicinal Chemistry

Solid Phase Microextraction

Dehydration of Alcohols-Gas Chromatography

Designed polymers for purification of flavor oils

Institute for Chemical Education, Fun With Chemistry; Vol. 1, Sarquis, Mickey and Sarquis, Gerry, Ed.; University of Wisconsin Madison, 1991,

Liquid Chromatography

School of Chemistry UNIVERSITY OF KWAZULU-NATAL, WESTVILLE CAMPUS JUNE 2009 EXAMINATION CHEM340: INSTRUMENTAL ANALYSIS.

Introduction to Pharmaceutical Chemical Analysis

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to En vi ron men tal Aqueous Samples INTRODUCTION

TOTALLY INNOVATIVE MULTIMODE AUTOSAMPLER NEW KONIK ROBOKROM Laboratory Gas Generators An Overview +8 OPERATIONAL MODES MAIN FEATURES

Cellufine Butyl Cellufine Phenyl

THE USE OF ORGANOCLAY IN MANAGING DISSOLVED ORGANIC CONTAMINANTS RELEVANT TO CONTAMINATED SEDIMENTS

Sorptive sample preparation a review

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

High Performance Liquid Chromatography

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Analytical Chemistry

Yuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Instrumental Chemical Analysis

ERT320 BIOSEPARATION ENGINEERING CHROMATOGRAPHY

Ben Diamond. Sonoma State University

Chromatography What is it?

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Basic Principles for Purification Using Supercritical Fluid Chromatography

A solution is a homogeneous mixture of two or more substances.

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

Chromatography and its applications

High Performance Liquid Chromatography

Introduction to Gas Chromatography

Physical Separations and Chromatography

Chemistry Gas Chromatography: Separation of Volatile Organics

Spectroscopy and Chromatography

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Luminescence transitions. Fluorescence spectroscopy

Development of Portable GC/MS System with Benchtop Performance for Critical DoD Applications. Mitch Wells, Ph.D. Philip Tackett, Ph.D.

Recently Developed Techniques for Extraction of Drugs and Medicines during. Chromatographic Determination in Toxicological Analysis

9.1 Water. Chapter 9 Solutions. Water. Water in Foods

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

Gas Chromatography (GC)

Transcription:

Chemical Analysis Problem Hair analysis is frequently used for the long-term monitoring of drug and alcohol users. You are working at a forensics laboratory and have been given the task of developing a method for the analysis of hair samples from suspects for alcohol and drug usage. How would you go about doing this to determine if an individual has been using drugs? Methadone Nicotine Chlorphenamine Heroin Lipophilic able to dissolved in oils, lipids and non-polar solvents

Solid Phase Microextraction (SPME) Challenge Can the measurement scientist use sample preparation for analyte preconcentration (to lower detection limits) and or to remove analytes from a complex matrix? Sample preparation is an essential step in analysis, greatly influencing the reliability and accuracy of resulted the time and cost of analysis. Solid-Phase Microextraction (SPME) is a very simple and efficient, solventless sample preparation method, invented by J. Pawliszyn in 1989. Hair differs from other traditional biological samples used for human toxicological analysis such as urine, blood, liver or saliva with its significantly longer detection window (months) allowing retrospective investigation and measurement of drug consumption.

Solid Phase Microextraction (SPME) SPME is a fast, solventless alternative to conventional sample extraction techniques. Analytes establish equilibria among the sample matrix, the headspace above the sample, and a polymer-coated fused fiber, then are desorbed from the fiber to a chromatography column.

Analyte Adsorbed Theory of SPME Pre-equilibrium Big effect of time Equilibrium - change in time has little effect on amount adsorbed Extraction Time Molecular adsorption onto the solid phase from either head space or solution. Moles adsorbed (i) = K eq,spme x V SPME x C(i)

Solid Phase Material Polydimethylsiloxane (PDMS) Active sites Nonpolar sorbent phase medium to non-polar volatile and semi-volatile analytes 280-300 o C stability Useful for both GC and HPLC analysis 100 μm thick The chemistry of the sorptive SPME layer plays a significant role in enhancing or discriminating against classes of compounds!!

Chemical Problem Hair Analysis Apart from external drug deposition on hair, drugs are mainly enclosed tightly in the hair shaft and to a certain extent maybe bound to proteins, melanin or lipids of the cell membrane complex. Therefore, hair matrix type, structure of the drug, method and duration of extraction, and solvent used are all important factors affecting the final extraction yield. 1. Hair sample collection and preparation (washing, drying and weighing). 2. Digestion or removal of drugs from hair matrix (NaOH, CH 3 OH) 3. Control measurements to determine recovery of drugs. Why important? Pharmacology & Pharmacy Vol.3 No.3(2012), Article ID:20639,12 pages DOI:10.4236/pp.2012.33035

Approach for Hair Analysis

Solid Phase Microextraction Head Space

Example Data from Hair Analysis 50 μg/l or 50 ppb samples Fiber chemistry and thickness can make a difference in extraction efficiency. Sigma-Aldrich

Solid Phase Microextraction (SPME) 25-50 μl injection volume

Percent Recovery Percent recovery is used in cases where no chemical reaction is taking place, as in purification of a sample. It is calculated as follows: Percent Recovery (%) = amount of pure product recovered (g) amount of crude product used (g) x 100 For quantitative analysis of samples using SPME, one must know the % percent recovery. Experiments can be done to determine this. Alternately, one can generate a response curve using the SPME on standard solutions and this would take into account the percent recovery for the specific extraction conditions.

Solid Phase Extraction Solid-phase extraction (SPE) is a sample preparation process by which compounds that are dissolved or suspended in a liquid mixture are separated from other compounds in the mixture according to their physical and chemical properties. Analytical laboratories use solid phase extraction to concentrate and purify samples for analysis. Normal phase (polar) Reversed phase (non-polar) Anion exchange (anions) Cation exchange (cations)

Solid Phase Extraction (SPE) Analytes must have some chemical affinity for the packing material or the stat. phase. Must select the packing material to have some specific chemical interactions or affinity for the analytes of interest. Process is very much like that which occurs during an analytical separation on a column, often with some preconcentration used.

Solid Phase Extraction (SPE) Steps in Process Select the proper stat. phase Condition the stat. phase Add the sample (ml) Wash the stat. phase Elute the compounds of interest Solvent or solution selection for the elution depends on the chemistry of the stat. phase and chemical nature of the analytes.

Solid Phase Extraction Solid-phase extraction (SPE) is a sample preparation process by which compounds that are dissolved or suspended in a liquid mixture are separated from other compounds in the mixture according to their physical and chemical properties. Preconcentration volume passed vs. volume eluted If 10 ml of sample is passed through the packing and then elution is done with 100 μl of solvent, then preconcentration factor is 100x!!!

Solid Phase Extraction Analysis often by HPLC. Excellent for sample clean up and analyte preconcentration. Process is much like that which occurs on the stationary phase of an analytical column.