Similar documents
Lab Safety Rules GENERAL GUIDELINES. 1. Conduct yourself in a responsible manner at all times in the laboratory.

EOSMS Guidelines Date: 01/16/2014 Page 1 of 5

General Rules. Be alert and responsible at all times in the laboratory.

Objective: Science Classroom Laboratory Safety

Laboratory Safety SAFETY IN THE LABORATORY

Safety and Rules of the Lab

Completion Match each each piece of equipment with its description. Please only put one number in the blank.

Science Safety Booklet

Chemistry 102: General Chemistry II Laboratory Course Syllabus Spring 2010

Newton s Second Law of Motion

Scientific Inquiry. Standards B 1.2 & B 1.9

Safety in the Chemistry Laboratory

1. The Supervisor and/or the Section Safety Officer must be notified of all accidents and injuries which may occur within the section.

UNIT 01 LAB SAFETY & EQUIPMENT

2.8-1 SCIENCE EXPERIMENTS ON FILE Revised Edition. Dew Formation

Simple Battery. Alessandro Volta ( ) A replica of the first battery, built by Volta, can be created and used to understand electricity.

Chemistry Lab Safety

HHPS WHMIS. Rules MSDS Hazard Codes Systems. Biology based. Chemistry based. Safety Symbols. Safety in the Lab. Lab Equipment

DARKROOM HAZARDOUS WASTE MANAGEMENT GUIDE

Topic Students devise an experiment to determine the types of bonds in three compounds.

Scientific Notation and Scaled Models

Introduction to Uncertainty and Treatment of Data

Introduction to the General Physics Laboratories

Basic Chemistry Laboratory Manual CHEM 101L Prof. Haber Prof. McPike Morrisville State College FALL 2017

Name: Period: Date: UNIT 0: Introduction to Chemistry Lecture 2: Success in Lab!

C. Eugene Bennett Department of Chemistry

Honors Chemistry 2016 Summer Assignment

1- Laboratory: Rules and Regulations 2- Procedure for the Withdrawal of Apparatus, disposable and chemicals

Plant Indicators for Acids and Bases

USING COINS TO MODEL RADIOACTIVE DECAY

CHEMICAL SAFETY TRAINING LEADER GUIDE. Chemical Safety Training Leader Workbook 1

CHEM 200 Chapter 2 General Work Practices

3. Chemical Hygiene Plan: Laboratory Standard Operating Procedures. A. Laboratory Specific Information and Signatures

Hazard Communication & Chemical Safety. Based on OSHA Standard

Full file at

Modeling Organic Chemistry

Department of Chemistry University of Vermont. Chemistry 144 Spring, 12 Organic Chemistry Professor J. Madalengoitia

SCIENCE LABORATORY POLICY

EXPERIMENT 6 Buffer Effects

Proper Reporting of Experimental Data

Lab Safety EYE PROTECTION CLOTHING AND PERSONAL ITEMS

Lab Equipment and Safety

Chesapeake Campus Chemistry 111 Laboratory

Create a safety video for your school's chemistry lab. Show what safety equipment is available and demonstrate how to properly use it

Year 7 Health & Safety

PROBLEM AREA 8 UNIT C8-2. Interest Approach LESSON 2. What skills are needed in agricultural mechanics? Student Learning Objectives.

Density of Aqueous Sodium Chloride Solutions

Exploring Habitats. Study Habitat Drawings to Identify Living Things & Nonliving Conditions. Safety Precautions

CHEMICAL MANAGEMENT PLAN

Voltaic Cells. 100 ml graduated cylinder Emery cloth 150 ml beakers, 3 Salt bridge Voltmeter Wires with alligator clips, 2

INSTRUCTOR: Mike Fenton OFFICE PHONE: (818) OFFICE: CMS 243

EXPERIMENT 2 Reaction Time Objectives Theory

TITRATION STAKES 2018 INSTRUCTIONS TO TEAM MEMBERS

Effective January 2008 All indicators in Standard / 11

De Anza College Chemistry Department Spring 2018

Chapter 1 Introduction to Science / Safety

CHEM 25 Preparation Course for General Chemistry 5 Unit(s)

To the Student. Materials The materials list shows the apparatus you need to have on hand for the activity.

Chemistry 64 Lab Winter 2006 GENERAL INFORMATION. Jian Yuan (310 Burke)

INSTRUCTOR (Lec 26801): Said Pazirandeh OFFICE PHONE: (818) OFFICE: CMS 242

5. Safety in the Organic Laboratory

LABORATORY SAFETY & PROTOCOL MANUAL

Treatment of Error in Experimental Measurements

The effects of sodium chloride on the Boiling Point of Dihydrogen Monoxide

LABORATORY SCHEDULE. CHEM 121L SPRING 2019 Date Experiment Page. 1/22/19 1. Check-In/Safety and Balances 13

PART I: MEASURING MASS

PS. 1 - SCIENTIFIC INVESTIGATION

Standard Operating Procedure

experiment3 Introduction to Data Analysis

Chemistry IA Course Syllabus

Chemistry: Introduction to Chemistry

Moles, Mass, and Volume

Po Kok Secondary School S.1 Integrated Science Chapter 1.1 Classwork What is Science? Class: S.1 ( ) Date: A. What is Science? P.

Uncertainty, Error, and Precision in Quantitative Measurements an Introduction 4.4 cm Experimental error

CIVIL & ENVIRONMENTAL ENGINEERING 5610/6610 WATER CHEMISTRY AND LABORATORY ANALYSIS UNIVERSITY OF UTAH FALL SEMESTER 2005

General Chemistry 10122/10125

Lab #5 - Limiting Reagent

SECTION 3 PRODUCT COMPOSITION The test kit is composed of QuSTICK Strep A Reagent Stick, Reagent A, Reagent B, Positive Control, and Negative Control.

Honors Chemistry Summer Assignments

Percentage of Acetic Acid in Vinegar

Slide 1 / 25. Slide 2 / 25. Applying Green Chemistry to Purification. The goals of this lab are to: Background Slide 3 / 25

LABORATORY SCHEDULE CHEM 122L SPRING 2019

Individual Laboratory Safety & Chemical Hygiene Plan

Density of Aqueous Sodium Chloride Solutions

EXPERIMENT 1 Chemistry 110 LABORATORY SAFETY

CHEM 124L Syllabus General Organic and Biochemistry Lab Summer 2014

GHS/ CHEMICAL RIGHT TO KNOW

Experiment 1 - Mass, Volume and Graphing

GENERAL INSTRUCTIONS

PREREQUISITE: Chem. 25 with a C or better or high school chemistry with a B or better, Math C or higher.

Uncertainty Analysis of Experimental Data and Dimensional Measurements

CHEM 1B General Chemistry 5 Unit(s)

Measurement. Objectives. Assessment. Assessment. Physics terms. Assessment 5/13/14. Make measurements with accuracy and precision.

Junior Laboratory. PHYC 307L, Spring Webpage:

Syllabus: General Chemistry Monday, Wednesday, Friday 9:10-10:05 am WH 141 Dr. C. Scholz

ph and Titrations Lesson Created by: Length of lesson: Description of the class: Name of course: Grade level: Honors or regular:

Unit 1: Safety in the Laboratory

Periodicity of Properties of Oxides

Experiment 2 Random Error and Basic Statistics

Chemistry 102 GENERAL CHEMISTRY II Day/Time: Lec: MW 5:15-6:40 pm Section: 3157 & 3158 Room: CMS 236

Transcription:

By: Daisy Fuentes

Table Of Contents iii Table of Contents Table of Contents... iii Introduction... v Chemical Laboratory Safety Rules... 3 Safety Rules... 3 Experiment 1A: Statistical Analysis on Different Types of Pennies... 7 Introduction... 7 Figure 1.1:... 7 curacy v. Precision... 7 Equation 2: Standard deviation... 7 Equation 1: Mean value... 7 Figure 1.2 Normal distribution bell-shaped distribution... 8 Standard Deviation Determination on Post-1982 Pennies... 9 Comparison of Different Data Sets Using Student s t-test... 9 Equation 1.3... 10 Equation 1.4... 10 Table 1.1: Student s T for comparing two data sets (n1 = n2 = 5)... 11 Experiment 1B: Statistical Analysis of the Density of Coca-Cola Versus Diet Coke... 15 Introduction... 15 Density Determinations... 15 Comparison of Different Data Sets Using Student s T-test... 15 Index... 17

Introduction v Introduction The laboratory manual is designed for a two-semester general laboratory sequence for science majors. The laboratory experiments that have been included cover most (if not all) of the topics typically found in university-level general chemistry laboratory courses throughout the United States. Topics covered include: properties of matter stoichiometric relationships chemical formula molar mass determination, chemical syntheses properties of gases various statistical analyses thermochemistry phase behavior colligative properties acid base and oxidation chemical reactions chemical kinetics chemical equilibrium spectroscopic measurements electrochemistry Approximately half of the experiments use the Pasco probeware and data acquisition system (version 1.9.0). Using probeware, students are able to make temperature, absolute pressure, ph, potential and absorbance measurements. Measured values are displayed in real time, and using built-in software functions. Students can perform various mathematical computations and statistical analyses on their recorded experimental data. Although the specific instructions were written with the Pasco system in mind, the experiments can easily be adapted to other probeware and data acquisition systems, such as the Vernier system and MeasureNet system.

Fly Safety Rules

Safety Rules 3 Safety Rules 3 Chemical Laboratory Safety Rules Depending on your major, you will be enrolled in the general chemistry laboratory course for either one semester or for two semesters. Each semester you will perform twelve laboratory experiments, each of which is designed to illustrate different chemical principles and concepts, to apply several computational methods, and to learn various experiment techniques. You will be exposed to many different chemical substances, and will learn how to use various pieces of chemical glassware and chemical instrumentation. It is essential that you read the laboratory experiments prior to going to the laboratory, and that you abide by all of the chemical laboratory safety rules stated below. These rules are designed to ensure that work performed in the laboratory will be safe for you and your fellow students. After you have carefully read and understood the safety rules, please sign the attached form and give it to your teaching assistant. These should be two copies of the form, one copy to be signed and turned in this semester and the second copy is for next semester s course. Safety Rules 1. Never enter the laboratory unless your teaching assistant (TA) is present. Accidents are more likely to occur when students are left unsupervised in the chemistry laboratory. 2. Always wear approved safety goggles/glasses when in the chemistry laboratory. Regular vision glasses are not the same as chemical safety glasses. Vision glasses do not protect from the sides. 3. Always read the laboratory experiment ahead of time-and if you do have questions regarding safety or the experimental procedure, as your TA before attempting to perform the experiment. 4. Never eat, drink, chew, or smoke in the laboratory. 5. Wear sensible, relatively protective clothing. Open-toed shoes, sandals, etc. are not allowed nor are shorts, mini-skirts etc. The TAs have been instructed to send anyone who does not have proper footwear home. 6. Tie back long hair and remove ties/scarfs. 7. Always wash your hands before leaving the laboratory. 8. Horseplay and unauthorized experiments are not acceptable in the laboratory. 9. Place coats, jackets, books and backpacks in the book/backpack shelves located in the laboratory. Cluttered aisles and lab benches are dangerous. 10. Treat all chemicals, glassware and instrumentation with the utmost respect. 11. Never smell or touch chemicals unless specifically instructed to so. When instructed to smell chemicals, hold the container level with your nose, but removed by several inches, and waft the vapors towards you by waving your hand over the top of the container. Never put the container directly under your nose. 12. Chemical waste and broken glassware should be disposed of in the correct fashion. The laboratories have special containers for collecting chemical waste and broken glassware. The chemical waste containers will be labeled with the type of waste that is supposed to be put in

4 Modern General Chemistry Laboratory 4 Title of Manual the container. Read the label on the waste container before putting any chemical into the container. For safety reasons, some chemicals have to be disposed of in separate containers. The TA will provide more instruction on how you are to dispose of the chemicals for each laboratory experiment. 13. All accidents, breakages, spills injuries should be reported to the TA immediately. 14. Familiarize yourself with the location of all safety equipment-fire extinguishers, safety shower, eye-wash station, eye-wash bottles, and first aid kit. 15. Carefully read the label on bottles for identity of a substance before using the chemical. Abide by any warnings that might be on the label. 16. If you are unsure of any chemical, ask the TA or check the Materials Safety Data Sheets (MSDS) that are available in the Chemistry Stockroom for any chemical. 17. Never pipette by mouth. 18. Always clean up after yourself and keep your work area neat and clean at all times. When you leave the laboratory your work area should be clean and all common glassware returned to its storage location. The TA has been instructed to deduct points from that day s laboratory report if you leave without cleaning your work area. 19. If you break a thermometer, do not touch the mercury. Tell your TA immediately and cover any mercury with sulfur powder. The department has special kits for cleaning up any mercury that might be spilled. 20. Cover any acid spills with sodium bicarbonate (NaHCO3). 21. Be aware if all hazard warnings before entering the laboratory and follow them.

Fly Experiment 1A

Experiment 1A 7 Chapter 2 7 Experiment 1A: Statistical Analysis on Different Types of Pennies Introduction Every experimental measurement involves some level of experimental uncertainty or error. For example, if asked to repeatedly measure the length of an 8-foot table with a 12-inch ruler, you would not get exactly the same numerical value every time. There would be some level of uncertainty associated with placement of the ruler every time that you picked up the ruler and replaced it on the tabletop as you move from left-hand side of the table to the right-hand side. You would have to pick the ruler up several times to measure the table s length. Even if you were to make a small pencil or chalk mark on the tabletop to indicate where each ruler length ended, it would be difficult (if not impossible) to place the ruler in exactly the same spot every time in a series of replicate measurements. Experimental uncertainties (or errors) give rise to different numerical values when you make a series of replicate measurements on the same sample or object. In other words, there will be a dispersion (or spread) of the reproducibility (or scatter) of replicate measurements. Precision is a measure of the reproducibility (or scatter) of replicate measurements. Precision has absolutely nothing to do with how close the measured values are to the so-called true value. Figure 1.1: Accuracy v. Precision Accuracy is the term used to indicate how close a measured value is to the true or accepted value. The average of several replicate measurements might be accurate without being precise. Or conversely, a set of replicate measurements might be very reproducible (very precise), yet the measured values may not be very close to the try or accepted value. The ideal situation would be that the series of replicate measurements were both precise and accurate. Figure 1 shows accuracy, precision and both. Typically, when one performs a series of replicate measurements, one reports not only the individual values, but also the mean value (also referred to as the average value) and standard deviation. The mean value, x, is obtained by adding all of the individual measurements and then dividing by the total number of measurements. In Equation 1, Σ represents the mathematical Equation 1: Mean value summation operation, and n is the number of replicate measurments performed. Equation 2 shows how to calculate standard deviation. Standard deviations are generally expressed with a ± sign; e.g. 100.53 ±.32. The smaller the standard deviation, the less scattered the numerical values. When the standard deviation is small, the individual values are grouped closer about the mean value. Equation 2: Standard deviation

8 Modern General Chemistry Laboratory 8 Title of Manual The calculated standard deviation does have statistical significance in that random experimental errors follow a Gaussian error distribution (e.g., bell-shaped distribution in Figure 1.2). If a given measurement is performed a large number of times, you will obtain a range of numerical values that will be distributed according to a Gaussian error distribution, provided that you do not make systematic errors of measurement. For random errors, small errors are much more probable than large errors and positive deviations are just as likely as Figure 1.2 Normal distribution bell-shaped distribution negative ones. In the laboratory, we rarely repeat the same experiment enough timers to truly obtain a Gaussian distribution. We can take our smaller set of measured values; however, calculate the mean and standard deviation for our smaller data set, and using statistics project what the Gaussian distribution would look like, and had we performed the much larger number of experimental measurements. The standard deviation is used to describe the variation in a finite data set, whereas the variance (denoted as σ), or population standard deviation as it is sometimes called, is used in an infinite population. The variance is calculated in a similar fashion as the standard deviation, except that the denominator is n, rather than n-1. The population standard deviation measures the width of the Gaussian distribution curve. The larger the value of σ, the broader the curve. For any Gaussian distribution, 68.3% of the area under the curve falls in the range of x ± 1σ. That is. More than two-thirds of the measurements are expected to lie within one standard deviation of the mean. Also, 95.5% of the area under the Gaussian curve lies within x ± 3σ. Only a very small percentage of the experimental measurements would be expected to be more than 3 standard deviations from the mean as the result of random errors. One can use this rationalization in reverse. Suppose that one did measure an experimental value that was more than three standard deviations larger than the calculated average value for five replicate experimental determinations. The experiment had been performed five times, and one value was significantly different from the other values. What would you think or conclude based on the preceding discussion? That the difference between the one apparent outlier and the other four values resulted from solely random errors, or that one unknowingly made a mistake in that particular experimental measurement? In Experiment 1, we will determine the average mass and standard deviation for a post-1982 collection of pennies, and using statistics determine whether or not there is a significant difference in the mass of a pre-1982 penny versus the mass of post-1982 penny versus the mass of a 1943 steel penny. In 1982 the United States Mint changed the composition of the penny from a predominantly copper-based alloy (1963-1982 pennies are 95% Cu + 5 % Zn; 1947-1962

Experiment 1A 9 Chapter 2 9 pennies are 95% Cu + 5% Zn & Sn) to a zinc-based alloy (97.5% Zn + 2.5% Cu). The 1943 pennies were made of steel with zinc coating. The diameter of the penny has remained the same. 19mm. If a difference is found, it will be caused by a change in the manufacturing process (e.g., different alloy material), and not the uncertainty in measuring the mass of the penny. The error in the mass measurement should be quite small, if the electronic balance is functioning properly. The manufacturer s specification for our electronic balanced is an accuracy of ± 2 in the last decimal place. The type of statistical analysis that we will be performing is quite similar to what manufacturing companies us in assessing quality control, in doing hypothesis testing, and in verifying warranty claims. In manufacturing applications, one would be applying statistical methods to determine whether or not a manufactured product met the given specification within the predetermined, set tolerance level. Standard Deviation Determination on Post-1982 Pennies 1. Using an electronic balance, determine the mass of 20 post-1982 pennies. 2. Record the mass of each penny on your Laboratory Data Sheet for Experiment 1. 3. Calculate the average mass (mean) and standard deviation of the 20-post 1982 pennies. 4. Record the mean and standard deviation on the Data Sheet in the indicated space. Comparison of Different Data Sets Using Student s t-test 1. Using an electronic balance, determine the mass of five pre-1982 and five post-1982 pennies. 2. Record the mass of the individual pennies on the laboratory data sheet. The masses of five 1943 steel pennies have already been recorded on the data sheet for you. The data sheets will guide you through the three mean and standard deviation calculations if your calculator does not have this built-in function. Alternatively, you can calculate the mean and standard deviation of each data set using Microsoft Excel spreadsheet. 3. Do this for the three datasets. Next, we need to analyze the experimental results using statistics to determine how significant the difference is between the pre-1982 pennies versus post-1982 pennies, between the pre-1982 pennies versus 1943 steel pennies. You need to make three comparisons. Some idea of whether or not there is a significant between any two data sets can be made by simply looking at the data sets being compared. Suppose that the two data sets had exactly the same average value to the third decimal place. What would your intuition tell you? That the two data sets were the same, at least as far as the mass is concerned. It is very unlikely though, that the two data sets will have exactly the same average value. Now what type of information would you want to have? You would probably want to know not only the average mass of each data set, but also how much variation was there in the individual masses for each data set. In other words, you would want to

10 Modern General Chemistry Laboratory 10 Title of Manual know the mean and standard deviation of both data sets being compared. As was stated earlier, we could use the calculated mean and standard deviation for each finite data set to construct a Gaussian distribution for the pre-1982 pennies, for the post-1982 pennies and for the 1943 steel pennies using statistic methods. If I were asked to compare the pre-1982 pennies versus the post- 1982, I could look at the amount of overlap between the two respective Gaussian distributions. For example, if the two Gaussian distributions were super-imposable on one another, then I would likely state that the two sets of pennies are definitely identical, at least as far as their mass is concerned. If there was a lot of overlap in the two Gaussian distributions, I would likely state that I believe that the two sets of pennies are identical. A little bit less overlap, that the two data sets may be identical. Even less overlap, that the two data sets are likely different. You will not that I was hedging my statement depending on how confident I was in the conclusion that I was making based on the analyses that I was visually doing by looking at the amount of overlap in the Gaussian distributions of the two data sets. The Student s T-test allows us to do a somewhat similar analysis, but in a more mathematical fashion. Using the Student s T-test, we will assign a perfect confidence level that the two different groups of pennies in fact represent different data sets or populations. To determine with what percent confidence level the two sets of data are different, we need to calculate a Student s T-Value, which will be Tcalc = x 1 x 2 Spooled Equation 1.3 n1n2 n1+n2 compared with statistical tables. The Students T-value is calculated according to Equation 1.3 where x 1 = mean value of first set of pennies x 2 = mean value of second set of pennies n1 = number of pennies in first set n2 = number of pennies in second set Spooled = pooled standard deviation The value of Spooled us calculated using the standard deviations of the two sets of pennies, S1 and S2, respectively, according to Equation 1.4. Note that tcalc contains the same information that we used in our intuitive analysis, how close the two average values were to each other (x 1 - x 2), and the amount of scatter in the data sets (Spooled). Spooled = Equation 1.4 s1 2 (n1-1) + s2 2 (n2-1) n1 + n2 2

Experiment 1A 11 Chapter 2 11 Table 1.1 contains the theoretical values of Student s T-values at various confidence levels for your experiment. The table applies only for the number of measurements made here, namely for comparing two sets of values, with each data set containing five data points. If the value of tcalc that you calculate based on your experimental data exceeds the value give in Table 1.1, then there is a difference in the two data sets considered for the level of confidence that you were testing at. If tcalc does not exceed the tabulated value in Table 1.1, then there is not a significant difference in the two data sets. In science, we typically use a 95% confidence level or greater. In this experiment, there is only two possible outcomes: either the data sets are significantly different or they are not significantly different. One would have a 50-50 chance of guessing the correct result. We want to be more confident in our answer than this. What does a conclusion at the 95% confidence level mean? Suppose that we concluded at the 95% confidence level that the mass of pre-1982 and post-1982 pennies was significantly different. What this means is that if we repeated the exact same experiment 100 more times, 95 times we would get the same result. Confidence level (%) Student s T 50.706 90 1.860 95 2.306 98 2.896 99 3.355 99.5 3.832 99.9 5.041 Table 1.1: Student s T for comparing two data sets (n1 = n2 = 5)

Experiment 1B Fly Page

Experiment 1B 15 Experiment 1B: Statistical Analysis of the Density of Coca-Cola Versus Diet Coke Introduction Density Determinations Comparison of Different Data Sets Using Student s T-test

Index 17 Index Accuracy, 7 mean value, 7, 10 Precision, 7 standard deviation, 7, 8, 9, 10