Effective Lab Oral Report Spring 2018

Similar documents
Effective Lab Oral Report Fall 2018

Modern Experimental Physics Introduction for Physics 401 students. Eugene V. Colla

Modern Experimental Physics Introduction for Physics 401 students. Fall 2017 Eugene V. Colla

PHYS 228 Template Example

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

PHYS General Physics II Lab The Balmer Series for Hydrogen Source. c = speed of light = 3 x 10 8 m/s

Experiment 9. Emission Spectra. measure the emission spectrum of a source of light using the digital spectrometer.

University of Maryland Department of Physics. Spring 2009 Final Exam 20. May (175 points) Post grades on web? (Initial, please) Yes No

Schematic for resistivity measurement

MODERN OPTICS. P47 Optics: Unit 9

Lab 10: Spectroscopy & the Hydrogen Atom Phy208 Fall 2008

Requirements for scaleable QIP

Experimental Physics I & II "Junior Lab" Fall Spring 2008

Observation of Atomic Spectra

Exploring diffraction

Physics 403 Modern Physics Laboratory. Fall 2014 Eugene V Colla, Liang Yang

PPT PRESENTATION. What works, and what doesn t. Associate Dean USF Graduate School. Revised

Physics 231 Lab 8 & 9

Atomic Spectra HISTORY AND THEORY

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO

AS 101: Day Lab #2 Summer Spectroscopy

Designing and Delivering an Effective Research Talk

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

Emission Spectroscopy

Physics 2310 Lab #3 Driven Harmonic Oscillator

Questions on Electric Fields

DAY LABORATORY EXERCISE: SPECTROSCOPY

Reference literature. (See: CHEM 2470 notes, Module 8 Textbook 6th ed., Chapters )

Measurements of ultralow temperatures

Chapter 5 Simplifying Formulas and Solving Equations

Praktikum zur. Materialanalytik

Blind Measurements and Precision Muon Physics. David Hertzog University of Washington

Lab 6 - Electron Charge-To-Mass Ratio

B = 8 0 NI/[r (5) 3/2 ],

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO

Measuring Cosmic Ray Muon Decay Constant and Flux

QUIZ 4 REVIEW QUIZ (DEC 7)

Electron Spin Resonance. Laboratory & Computational Physics 2

LAB 3 - VELOCITY AND ACCELERATION

Principles and Applications of Superconducting Quantum Interference Devices (SQUIDs)

EXPERIMENTAL COMPETITION

Relativistic Electrons

Linear Motion with Constant Acceleration

Lab 6 - ELECTRON CHARGE-TO-MASS RATIO

Electron Spin Resonance. Laboratory & Comp. Physics 2

Magnetization Gradients, k-space and Molecular Diffusion. Magnetic field gradients, magnetization gratings and k-space

n(λ) = c/v(λ). Figure 1: Dispersion curves for some common optical glass types.

= 6 (1/ nm) So what is probability of finding electron tunneled into a barrier 3 ev high?

PHYSICS 116 SPECTROSCOPY: DETERMINATION OF THE WAVELENGTH OF LIGHT

Atomic Theory: Spectroscopy and Flame Tests

Advanced Optical Communications Prof. R. K. Shevgaonkar Department of Electrical Engineering Indian Institute of Technology, Bombay

Atomic Theory: Spectroscopy and Flame Tests

NMR Spectroscopy Laboratory Experiment Introduction. 2. Theory

Question 1. (Marks 16)

Finding e/m. Purpose. The purpose of this lab is to determine the charge to mass ratio of the electron. Equipment

Power Point Presentation Example

Circuits for Analog System Design Prof. Gunashekaran M K Center for Electronics Design and Technology Indian Institute of Science, Bangalore

PHY451, Spring /5

Energy loss of alpha particles - Prelab questions

Lab 5: Spectroscopy & the Hydrogen Atom Phy248 Spring 2009

University of Massachusetts, Amherst

Atomic Theory: Spectroscopy and Flame Tests

With that first concept in mind, it is seen that a spinning nucleus creates a magnetic field, like a bar magnet

Polarized Light. Nikki Truss. Abstract:

What detectors measure

Signals in Particle Detectors (1/2?)

Optics in a Fish Tank Demonstrations for the Classroom

Phys 2310 Fri. Dec. 12, 2014 Today s Topics. Begin Chapter 13: Lasers Reading for Next Time

Phys 2310 Mon. Dec. 4, 2017 Today s Topics. Begin supplementary material: Lasers Reading for Next Time

X-ray spectroscopy: Experimental studies of Moseley s law (K-line x-ray fluorescence) and x-ray material s composition determination

Communication Engineering Prof. Surendra Prasad Department of Electrical Engineering Indian Institute of Technology, Delhi

EXAMINATION QUESTIONS (6)

Experiment Ma8: Superconductivity

Laboratory Atomic Emission Spectrum

Name Date Time to Complete

Math Lecture 3 Notes

LAB 4: Gamma-ray coincidence spectrometry (2018)

OPSE FINAL EXAM Fall 2016 YOU MUST SHOW YOUR WORK. ANSWERS THAT ARE NOT JUSTIFIED WILL BE GIVEN ZERO CREDIT.

LAB: MOTION ON HILLS

HSC KICKSTART PHYSICS WORKSHOP

Spectroscopy of Various Light Sources: The Interactions between Light and Matter ASTR 170B1, Spring 2017, Lab #2. 1 Introduction.

LEP 2 Energy Calibration and the Spectrometer

positron source EPOS - general concept - timing system - digital lifetime measurement

Goals: Equipment: Introduction:

LAB 3: VELOCITY AND ACCELERATION

Solving Quadratic & Higher Degree Equations

Overview of Experiments for Magnetic Torque

Temperature and Pressure Sensor Interfaces for the ATTA Experiment. Ashleigh Lonis Columbia University REU 2012

EMISSION SPECTROSCOPY

$100 $400 $400 $400 $500

Electron Current Extraction and Interaction of RF mdbd Arrays

Grade Level 11 (9-12) Activity Dependency Time Required: 10 minutes Group Size: 2 to 4 persons Expendable Cost per Group US $0.80

Background The power radiated by a black body of temperature T, is given by the Stefan-Boltzmann Law

Radioactivity and Ionizing Radiation

Optogalvanic spectroscopy of the Zeeman effect in xenon

Fall 2014 Mott Target Replacement and Ladder Position Re- Calibration JLAB- TN Joe Grames. September 17, 2014

Nuclear Physics Fundamental and Application Prof. H. C. Verma Department of Physics Indian Institute of Technology, Kanpur

Fall 2014 Nobby Kobayashi (Based on the notes by E.D.H Green and E.L Allen, SJSU) 1.0 Learning Objectives

2. In words, what is electrical current? 3. Try measuring the current at various points of the circuit using an ammeter.

Transcription:

Effective Lab Oral Report Spring 2018 David Hertzog, Eugene V Colla, Virginia Lorenz University of Illinois at Urbana-Champaign DKDP We will present some of my slides and many Phys 403 student slides as examples. We can talk about why they are well constructed examples. (All remarks about real slides are in these red boxes) An eye-catching feature on slide 1

This is a technical presentation, so you must develop it as a logical sequence What was the goal? What physics did you address? What technology? Define your special vocabulary here What did you actually do? Apparatus / Procedures / Raw Data Sentence title tells what the slide is about the rest of the slide supports the assertion Fonts matter Arial Comic Sans Times X What are your results? Polished graphs, proofs, numerical findings Principal difficulties and uncertainties Courier X Conclusions

Presentation components and grading scale. Title slide Science introduction Procedure Results. Analysis. Data. Conclusions. Suggestions etc. CRITERIA Technical slides (15) Science accuracy (15) Quality of oral delivery and sharing of effort (15) Got essential points across of effort (15) Overall impression (15) Final Totals (75) Score Physics 403. Summer 2017 3

Title Title slide Author name Student name 2/19/13 Date Physics 403, Fall 2013 University of Illinois at Urbana- Champaign Affiliation Physics 403. Summer 2017 4

Science introduction Phase transition of Helium 4 Below T λ = 2.17 K, helium exists in mixture of superfluid and normal liquid helium. λ line cooling Physics 403. Summer 2017 5

The muon lifetime leads to the most precise determination of the Fermi constant, and gives the weak interaction strength The relation is measure this 1 2 G F t 1 MuLan aims to determine t m to 1 part per million precision, which requires: 10 12 muon decays A muon beam of several MHz A time-structured (chopped) beam

The experimental concept in one animation What happen if they are struck by pulses? A pulse or a series of pulses is used to change the net magnetization of system. Pulsed NMR! z 90 0 Pulse z x y x y z x y? Physics 403. Summer 2017 M () t M e 0 t T 2 7

What happens to a nucleus in a magnetic field? B = 0 B = B 0 ΔE M z = -1/2 M z = +1/2 m w w m Energy U = -mb (Courtesy of Bishop. K) E B w Larmor frequency! 0 0 Physics 403. Summer 2017 8

Phase Transition in BaTiO 3 Gibbs Free Energy Polarization Physics 403. Summer 2017 9

Phase Transition in BaTiO 3 Gibbs Free Energy Polarization Physics 403. Summer 2017 10

Phase Transition in BaTiO 3 Gibbs Free Energy Polarization Physics 403. Summer 2017 11

Phase Transition in BaTiO 3 Gibbs Free Energy Polarization Physics 403. Summer 2017 12

ASIDE: Keep equations selective and informative What can an audience grasp in real time? If they already know it, then they know it If they don t know it, they usually have to study it term by term Take a simpler approach Substitute proportionalities for equalities? Can eliminates uninteresting constants Can emphasize relationship of variables Substitute words for blocks of standard terms? 1 t G 2 m 5 F m 1 3 192 1 2 G F t 1 (phase space) M ij Set them off attractively Use builds and arrows to walk audience thru (see example)

When you really need your audience to understand a core equation that is central to your discussion, do it in parts and label them as you go observed signal Excitation and fluorescence signal convoluted together t F t E t F t t dt excitation signal Excitation as sinusoid is simplest: 0 0 1 E t E 2E cos( wt) Generalized through Fourier analysis simple fluorescence response (exponential) All periodic function can be expanded as sum of sinusoids Physics 403. Summer 2017 14

Show the equipment IF it helps explain your steps not because you love it Photographs give scale and reality but you add labels Schematics provide concept Icons strip away unnecessary details All of these techniques can be useful Vacuum chamber Mass spectrometer RHEED screen Source flanges

Everybody loves an optical bench, but unless you map out the elements and the beam paths, it doesn t mean much Experimental Apparatus Polarizer Diffraction Grating Beam Reducer Polarizer Chopper PRQW Physics 403. Summer 2017 16

An example of image which is nice but does not help too much

Magnetic Field Calibration The magnetic field from the Earth and other residual magnetic fields is minimized by rotating the stand and adjusting the vertical field coils to minimize the zero field peak width. With the main field coils off, the sweep field is applied to determine the center of the zero field resonance (was found to be at 0.251A; using the geometry of the coils, this corresponds to 0.151 gauss). RF field is adjusted to provide maximum transition probability. Too many words on slide

Setup diagrams, apparatus, measuring idea GPIB Cryostat 6.4mA DC Current for receiver Power Supply AC input SR830 Lock-in amplifier Receiver Acrylic Cavity Liquid He Transmitter Asin(wt) Function generator Agilent 33120A DT470 Silicon Diode 10mA LakeShore 110 DC current supply DMM Agilent 34401A Physics 403. Summer 2017 Schematic diagram adapted from notes 19

Samples: preparation, configuration etc. Silver Paint Electrode Sample Leads Physics 403. Summer 2017 20

Setup of Source and Detectors C θ BC θ AC Anode (to CFD) B Dynode (to MCA) A Aperture High voltage power supply θ AB Physics 403. Summer 2017 21

Results Raw tunneling data Energy gap derived from tunneling conductivity t M 3.9 0.14 ms Data + fitting results fluorescence Data + fitting results a- range t a slow slow 3.54 0.013 ms 99% t a fast fast 4 ns 1% Physics 403. Summer 2017 22

Results Difference in Up-Down (unnormalized) t Fit equation Ne t 1 a cos( w t ) Courtesy Samuel Homiller and Pakpoom Buabthong Fall 2013 Physics 403. Summer 2017 23

Results Difference in Up-Down (normalized} t Fit equation Ne t 1 a cos( w t ) Courtesy Samuel Homiller and Pakpoom Buabthong Fall 2013 Physics 403. Summer 2017 24

Results witnessing a mystery? Physics 403. Summer 2017 25

Presenting data is your most important and challenging task

Fitting to the Curie-Weiss law ' T C T C off C 3563.3 0.4K T C 118.9825 0.0003 K T c Courtesy Zongyuan Wang and Arnulf Taylor Su 2017 Physics 403. Summer 2017 27

AFM of Optical Data Storage Media CD DVD Blu-Ray CD DVD Blu-Ray Mark length 0.99-2.96 0.48-1.45 0.14-0.41 Track pitch Track width 1.63 1.00 0.40 0.50 0.24 0.15 Physics 403. Summer 2017 Units in μm 28

Fitting the data 5.6 1 T T T T T T C V offset offset T T T T T T C V offset offset 1 Offset, intrinsic to the experiment Fit to the exponents as well Perform the 5 parameter fit- The values that are obtained are not very close to the expected values Also, the fit is not the best 2.17 26 T C Physics 403. Summer 2017 29

Try a simpler fit Try to fit the data with this function The data refuses to fit to this function V 1 T T T offset Physics 403. Summer 2017 30

Finish your talk with the data analysis and conclusions and a slide showing the main points you want us to remember Make sure you discuss the principal uncertainties. For most of these experiments, it will be how accurately does your instrument measure something A few experiments will also have statistical uncertainties more data leading to a better finding Include a representative (simplified) graphic This slide will be up during question period so this graphic will get burned into people s memory Because this is a lab, offer some advice for others who follow

Typical Problems Nice Figure Great Data but lines are too thick and symbols are too small

Typical Problems Too many lines graph should be polished Use more contrast color for lines