Similar documents
GL Chromatodisc. Usage Type Description. GL Chromatodisc Type A GL Chromatodisc Type P GL Chromatodisc Type N 13AI

Chemical Compatibility Guide and Life Expectancy for the SolVac Filter Holder

Glove Selection Chart

Spectra/Por. Float-A-Lyzer READY-TO-USE DIALYSIS DEVICES. Product Information & Operating Instructions

Micro Float-A-Lyzer READY-TO-USE MICRODIALYSIS DEVICES. Product Information & Operating Instructions

Tube O Reactor. (Micro: Cat. # K, K, K) (Medi: Cat. # K, K, K)

Sizes 48" x 96" (1.22m x 2.44m) Custom sheet sizes available upon request

TAMMSFLEX SL / TAMMSFLEX NS

Safe Installation and Use of the NanoRam Immersion Probe

500 SERIES CHEMICAL RESISTANCE GUIDE

Technical data and operating instructions. Vivaspin 4. Vivaspin 4 10K device for in vitro diagnostic use

3.0 Spiraltek Rolled Filters

Chemical Polyurethane Polyethelyne PVC Nylon 11 Kynar

Halar ECTFE chemical resistance chart

High Purity Chromasolv Solvents

Category Major Groups Products

Swell Sheet Chemical Resistance Guide

Swell Sheet Chemical Resistance Guide

Chemical Compatibility of Filter Components

Appendix 5: table of chemical compatibility for tubing

A freely accessible HNS data base

PRODUCT DATA SHEET PDS A88_E

Gloves: choice and use

The best material for original Eppendorf Tubes and Plates: Properties and chemical resistance of polypropylene

Laboratory filtration. Principles and chemical compatibility chart

Zeta Plus LP Series. Lenntech. Applications. Features and Benefi ts. Lenticular Depth Filter Cartridges

Revised Permeation Values for DuPont Tychem SL

PRODUCT DATA SHEET PDS A112_E. Metric thread M 1.5 pitch CEI EN CEI EN 50262

Color Availability Clear Standard colors stocked (thin gauge only) Custom colors available by special order.

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products.

stance et Helper Eppendorf Pipet Helper Chemical Resistance

HSW NORM-JECT SYRINGES CHEMICAL RESISTANCE CHART

Materials of Construction and Chemical Compatibility for Sensing and Control Products

Choosing the Right KLEENGUARD* Chemical Resistant Glove for the Job

Chemical Resistance Guide for Flowchem EPN

LATEST TECHNOLOGY IN Safe handling & Recovery OF Solvents in Pharma Industry

stance 4 Repeater M4 Register your instrument! Multipette M4 Repeater M4 Chemical Resistance

Headspace Technology for GC and GC/MS: Features, benefits & applications

BEST PRACTICE GUIDELINES

Aromatic Hydrocarbons

SOLUZIONI PER L ENERGIA TERMICA THERMAL ENERGY SOLUTIONS

PRODUCT DATA SHEET PDS A4_E. Metric thread M 1.5 pitch CEI EN CEI EN 50262

KOCH MODULAR PROCESS SYSTEMS

Chemical Compatibility Guide Issue One

MEMBREX. Ready-to-use Syringe Filters < 1 up to 100 ml. Minimizes Loss of Sample. Minimale Holdup-Volume. Low Adsorption.

Ferdowsi University of Mashhad

Peek Chemical Resistance

Zeta Plus HT Series. Lenntech. Applications. Features and Benefi ts. Lenticular Depth Filter Cartridges

Spectroscopy in Inorganic Chemistry. Electronic Absorption Spectroscopy

FUNDERMAX GMBH TEST REPORT

Test Report For: FunderMax GmbH. MAX Resistance 2. SEFA , 2.1 Chemical/Stain Resistances

APPENDIX C CHEMICALS USED IN CLANDESTINE DRUG LABS

CHEMICAL RESISTANCE TABLE

Eppendorf UVette. Instructions for use

CHEMICAL RESISTANCE DATA FOR POLYETHYLENES

ADDITIVES FOR PAINTS, INKS & COATINGS. Innovative Silicone Specialties

8 Materials, Corrosion Resistance Tables

CHEMICAL RESISTANCE LIST

gerflor.com.au Stain chemicals

15.1: Hydrocarbon Reactions

Acetals, more than solvents. Expanding Chemistry 8-9 November 2017

Chemical Resistance Properties of Anko Tubing

Solshield Hydrocarbon Gas Membrane Chemical Resistance Table

An alcohol is a compound obtained by substituting a hydoxyl group ( OH) for an H atom on a carbon atom of a hydrocarbon group.

ecoinvent data v2.0 Life-Cycle Inventories of Petrochemical Solvents and Highly Pure Chemicals

Proper Storage of Chemicals in Laboratories

Amicon Ultra-15 10K Centrifugal Filter Devices

Buy 2 Get 1 FREE on Acros Organics

COPPER SHEATHED CABLE

Pervaporation: An Overview

PREVENTING HAZARDOUS WASTE FINES

Combustible Gas Catalytic Bead (0-100 %LEL) Part No FM Performance Certified 1,4 FM Performance Certified 1

CHEMICAL RESISTANCE LIST

Technical/Application Article 01 Version 1.2

Desalting and Buffer Exchange with Corning Spin-X UFCentrifugal Concentrators

Target Compound Results Summary

NJ MATERIALS ACCOUNTING & POLLUTION PREVENTION PLANNING

NaOH CH 3 CO 2 H C 2 H 5 OH. NaCl H 2 SO 4. Technical. Technical. Chemical Resistance Terms of Sale

Molded/Machined Both Both Machined Machined Both Dielectric Strength V/mil D ,000

CHEMICAL RESISTANCE OF BELZONA 1523 FN10150

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods

PROCESS TECHNOLOGY- ORGANIC II. 51. Gas phase dehydrogenation of ethyl-benzene to styrene occurs over catalyst based on

Watering Systems. Water and Chemical Reference Guide. Instruction # IM /06

CHEMICAL RESISTANCE LIST

Chemical Storage According to Compatibility

HAZARDOUS MATERIALS SURVEY. Note: List ALL virgin stock materials in current and projected inventories LAB NAME: PI: ADDRESS:

Zirconium in Organic Applications

DuPont Personal Protection Product Catalog

60PS Series Couplings

Liquid is assumed to be at saturated concentration in aqueous solution unless stated otherwise.

The Isosorbide Mononitrate Extended-Release Tablets Revision Bulletin supersedes the currently official monograph.

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

The Right Choice Merck Solvents for Analysis. Highest quality wide range of applications

Chemical Resistance Chart for Plastic Labware Please see page 428 for table notes and guide to abbreviations.

Chemistry 262 Homework 2 Part II Winter 2018

Unique Selectivity: The Power of Ionic Liquid GC Columns

Thermo Scientific Titan3 and Target2 Chromatography Syringe Filters. Performance filtration solutions. for sample preparation

BELZONA PRODUCT DATA M516 CHEMICAL RESISTANCE OF BELZONA 1591

Handbook On Chemical Industries (Alcohol Based)

Fast, Quantitative Analysis of Residual Solvents in Cannabis Concentrates

Transcription:

Rev. Date: 20-Jun-2010 Ultipor Nylon 6,6 and N6,6 Posidyne Membrane Description Pall provides a complete range of Nylon 6,6 membranes for fluid filtration in the pharmaceutical, biotechnology, electronics, food and beverage industries, and for analytical applications. Ultipor Nylon N6,6 Membranes Ultipor Nylon 6,6 membranes are very resistant to mechanical, chemical and thermal stress. They can be used in either direction, are inherently hydrophilic, have high flow rates, low pressure drops and very low extractables. Where appropriate, they can be steam sterilized without change in flow or pore size characteristic. Ultipor Nylon 6,6 membranes are available in a wide range of pore sizes, and as supported and unsupported membranes. N6,6 Posidyne Membranes N6,6 Posidyne membranes possess all the benefits of the Ultipor N6,6 range, plus an important additional feature: Positive zeta potential in aqueous fluids. Many important contaminants, such as endotoxins, bacteria, viruses and colloidal silica are negatively charged, and the retention of these particles is therefore significantly improved with N6,6 Posidyne membranes. N6,6 Posidyne membranes are available in various pore sizes. Major Advantages Safe retention of contaminants Inherently hydrophilic Excellent flow rates Lot-to-lot and within-lot consistency Excellent handling properties Mechanically robust Low extractables Compatible with a variety of sealing methods Passes USP Class VI-121 C plastic test for biosafety Specifications Dimensions Master rolls: 12.75 x500 Packaging Core: Cores are PVC 3.0 I.D. Packaging: Shrink-wrap around outside of each roll.

Chemical Compatibility Acids Acetic acid - glacial: Not Acetic acid - 10%: Acetic acid - 30%: Acetic acid - 90%: Hydrochloric acid - conc. (35%): Not Hydrochloric acid - 6N (20%): Not Hydrochloric acid - 1N (3.3%): Not Nitric acid - conc. (67%): Not Nitric acid - 6N (27%): Not Sulfuric acid - conc. (96%): Not Sulfuric acid - 6N (16%): Insufficient Data Alcohols Amyl alcohol: Benzyl alcohol: Butanol: Ethanol: Insufficient Data Isopropanol: Not Methanol: Insufficient Data Aromatic Hydrocarbons Benzene: Toluene: Xylene: Bases Ammonium hydroxide - 3N (5.7%): Ammonium hydroxide - 6N (11.4%): Potassium hydroxide - 3N (15%): Sodium hydroxide - 3N (11%): Sodium hydroxide - 6N (22%): Esters Amyl acetate: Insufficient Data Butyl acetate: Cellosolve acetate: Ethyl acetate: Isopropyl acetate: Insufficient Data Methyl acetate: Ethers Ethyl ether: Limited Resistance Tetrahydrofuran: Tetrahydrofuran/water (50/50 v/v): Glycols Ethylene glycol: Limited Resistance Glycerol: Propylene glycol: Limited Resistance Halogenated Hydrocarbons Carbon tetrachloride: Chloroform: Ethylene dichloride: Limited Resistance Methylene chloride: Limited Resistance Tetrachloroethylene: Insufficient Data Ketones Acetone: Limited Resistance Cyclohexanone: Methyl ethyl ketone: Methyl isobutyl ketone: Miscellaneous Acetonitrile: Limited Resistance Dimethyl formamide: Dimethyl sulfoxide: Insufficient Data Formaldehyde - 37%:

Formaldehyde - 4%: Hexane - dry: Kerosene: Insufficient Data Pyridine: Insufficient Data 18 Megohn water: Oils Cottonseed: Peanut: Insufficient Data Sealing Method Compatibility ABS Acrylic EVA Latex Natural Rubber Poly Carbonate Polyester (PBT) Polyethylene Polypropylene PVC

Silicone Mechanical Seal: Not Compatible Styrene Synthetic Rubber Urethane (thermoplastic) Applications General filtration Laboratory filtration devices Performance Typical Membrane Characteristics Base Material Pore Size (µm) Thickness (mils) Thickness (µm) Supported nylon (hydrophilic) (LoProdyne LP) 0.2 5.5-7.0 139.7-177.8 Supported nylon (hydrophilic) (LoProdyne LP) 0.45 5.7-6.7 144.8-170.2 Supported nylon (hydrophilic) (LoProdyne LP) 1.2 5.0-7.5 127.0-190.5 Typical Performance Characteristics Base Material Supported nylon (hydrophilic) (LoProdyne LP) Supported nylon (hydrophilic) (LoProdyne LP) Supported nylon (hydrophilic) (LoProdyne LP) Pore Size (µm) Point (psi) Point (bar) Protein Binding (µg/cm 2 ) (inches Hg) (bar) 0.2 51.0-56.0 3.52-3.86 N/A < 26.5 < 0.89 0.45 32.0-36.0 2.21-2.48 N/A < 8.0 < 0.27 1.2 13.8-16.2 0.95-1.12 < 9.0 < 4.2 < 0.14 Typical Membrane Characteristics Base Material Pore Size (µm) Thickness (mils) Thickness (µm) (Ultipor, Biodyne A) 0.2 5.5-7.0 139.7-177.8 0.45 5.7-6.7 144.8-170.2 0.65 5.6-6.4 142.2-162.6 1.2 5.5-7.0 139.7-177.8 3.0 11.0-12.5* 279.4-317.5

5.0 11.0-12.5* 279.4-317.5 nylon (Posidyne, Biodyne B) 0.2 11.0-13.0* 279.4-330.2 0.45 5.7-6.7 144.8-170.2 0.8 5.5-7.0 139.7-177.8 1.2 11.0-12.5* 279.4-317.5 3.0 11.0-12.5* 279.4-317.5 5.0 11.0-12.5* 279.4-317.5 *Dual layer measurement. Typical Performance Characteristics Base Material Pore Size (µm) Point (psi) Point (bar) DNA Testing (pg) (inches Hg) (bar) 0.2 51.0-56.0 3.52-3.86 < 10 < 26.5 < 0.90 0.45 32.0-36.0 2.21-2.48 < 10 < 8.0 < 0.27 0.65 21.0-24.0 1.45-1.65 N/A N/A N/A 1.2 13.8-16.2 0.95-1.12 < 10 < 4.2 < 0.14 3.0 > 9.0 > 0.62 N/A < 2.5 < 0.08 5.0 > 5.0 > 0.34 N/A < 1.5 < 0.05 0.2 N/A N/A N/A < 25.0 < 0.85 0.45 32.0-36.0 2.21-2.48 < 10 N/A N/A 0.8 17.5-21.0 1.21-1.45 N/A < 5.5 < 0.19 1.2 13.0-15.0 KL5 0.90-1.03 N/A < 3.3 < 0.11 3.0 9.0-11.0 KL5 0.62-0.76 N/A < 2.0 < 0.07 5.0 5.0-7.0 KL5 0.34-0.48 N/A < 1.1 < 0.04 The Biodyne, LoProdyne, Posidyne, and Ultipor names are registered trademarks of Pall Corporation and are not available for use. Products in this datasheet may be covered by one or more patents including US 4,693,985; and US 4,886,836. Ordering Information For more information and to order this product, please contact the Pall Industrial Materials representative for your region, or email us at industrialmaterials@pall.com Western Hemisphere Pall Trincor Pall Membrane Technology Center 770 Pennsylvania Drive, Suite 100 Exton, Pennsylvania 19341 +1.610.458.9500 phone +1.610.458.9595 fax Europe Pall Filtersystems GmbH Werk Schumacher Crailsheim

Zur Fluegelau 70 D 74564 Crailsheim +49 7951 302 phone +49 7951 26511 fax Asia Nihon Pall Ltd. 6-8-1, Nishishinjuku Shinjuku-Ku Tokyo, Japan, 163-6017 +81 3 6901 5800 phone +81 3 5322 2134 fax Contact Information Copyright Pall Corporation Visit us on the Web at www.pall.com This information is accurate as of the revision date indicated.