CATALOG OR PART NUMBER SX SX18 4 SX20 5 SX20 SAMPLE SX20-4 SX SX21 5 SX21 SAMPLE SX22 5 SX22 SAMPLE SX23 5 SX23 SAMPLE SX24 5 SX24 SAMPLE

Similar documents
Radioactive Waste Requirements

Proper Segregation and Disposal of Low-Level Radioactive Waste Procedures

Basics of a/b Discrimination for Liquid Scintillation Counting

Radio-HPLC Flow Cells

TECHNETIUM-99 IN WATER

Phase stability and lithium loading capacity in a liquid scintillation cocktail

TECHNETIUM-99 IN SOIL

COMPARATIVE STUDY BETWEEN EXTERNAL STANDARD METHOD AND INTERNAL STANDARD METHOD FOR LOW-LEVEL TRITIUM MEASUREMENTS

A New Measurement Method For Tritium Rapid Detection by LSC. IM.CAEP Xu Qinghua

TECHNETIUM-99 IN WATER

Acronyms, Abbreviations, and Symbols Foreword to the First Edition Foreword to the Second Edition Preface to the First Edition Preface to the Second

LIQUID SCINTILLATION COUNTERS. {Beta Counters}

Effect of liquid scintillating cocktail volume on 3 H and 14 C measurement parameters using a Quantulus spectrometer

Validation of detection efficiency of alpha particles in commercial liquid scintillation counters

Practical Approaches using TDCR Measurements and Alpha/Beta Separation

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

PRACTICAL 3 ph AND BUFFERS

High Performance Liquid Scintillation Analyzers. For Any Research, Discovery or Environmental Application Challenging Your Lab

DETERMINATION OF BETA EMITTERS IN MATERIALS FROM RESEARCH REACTOR DECOMISSIONING

NICKEL-63/59 IN WATER

IvanaJakonić 1, Nataša Todorović 2, JovanaNikolov 2, Ines KrajcarBronić 3, BranislavaTenjović 4, MiroslavVesković 2

10/16/17 ACIDS AND BASES, DEFINED WATER IS AMPHOTERIC OUTLINE. 9.1 Properties of Acids and Bases. 9.2 ph. 9.3 Buffers

Hidex 300 SL Automatic TDCR Liquid Scintillation Counter

Preparation of Tritium Labeled Compounds and Their Scintillation Proximity Assays

1220 QUANTULUS The Ultra Low Level Liquid Scintillation Spectrometer

Determination of 210 Pb and 210 Po in Water Samples

Water - HW. PSI Chemistry

RADIOLOGICAL CHARACTERIZATION Laboratory Procedures

Paraquat ELISA Kit. Catalog Number KA assays Version: 17. Intended for research use only.

SCINTILLATION SYSTEMS CATALOG

Technical data and operating instructions. Vivaspin 4. Vivaspin 4 10K device for in vitro diagnostic use

Solutions. Experiment 11. Various Types of Solutions. Solution: A homogenous mixture consisting of ions or molecules

ProPac WCX-10 Columns

Make a mixture of a weak acid and its conjugate base (as the SALT) Make a mixture of a weak base and its conjugate acid (as the SALT)

5. What is the name of the phase transition that occurs when a solid is converted directly into a gas (without going through the liquid phase)?

Particle Characterization Laboratories, Inc.

Protease Inhibitor Cocktail A (1 tablet / 7 10 ml, Roche Cat# ) Protease inhibitor Cocktail B (0.5ml per 250ml, Calbiochem Cat# )

Scintillation Proximity Assay on the TopCount Microplate Scintillation Counter

IDENTIFICATION AND DETERMINATION OF HYDROQUINONE IN COSMETIC PRODUCTS 2 14/11/17 ACM 003 BY TLC AND HPLC

Geochemical dating of a Swiss freshwater limestone cave using 230 Th/ 234 U ingrow and 226 Ra-excess decay chronometry

Multiplexing immunoassay with SERS

Enzymatic Assay of PROTEIN KINASE C

SOLUTIONS CHAPTER 13

Cellufine Butyl Cellufine Phenyl

QuickZyme Hydroxyproline Assay

Hidex LSCs. LSC 2013 Barcelona

Diquat 1,1 -ethylene-2,2 -bipyridium dibromide salt Paraquat 1,1 -dimethyl-4,4 -bipyridium dichloride salt Initial Preparation

TRITIUM DETERMINATION IN WATER

NCERT. [H O] Since water is in large excess, its concentration can be assumed to be constant and combining it with K provides a new constant K w

11. Introduction to Acids, Bases, ph, and Buffers

LIQUID SCINTILLATION

Proper&es of Water. Lesson Overview. Lesson Overview. 2.2 Properties of Water

Counting Solutions LSC Technical Tips from PerkinElmer

Application Note. An Optimum Solution for the Automatic Control of Cutting Oils

Sero: p30 Crossover Electrophoresis for Semen

TaKaRa BCA Protein Assay Kit

Liquid Scintillation at NPL: Practical Applications

Gross Alpha-Gross Beta Analysis in Water by Liquid Scintillation Counting (LSC)

Determination of H-3 and C-14 in the frame of decommissioning projects at the Paul Scherrer Institute

Nuclear Engineering Seibersdorf GmbH

Mixtures. Chapters 12/13: Solutions and Colligative Properties. Types of Solutions. Suspensions. The Tyndall Effect: Colloid

6. Extraction. A. Background. (a) (b) (c) Figure 1. Mixing of Solvents

Microdetermination of phosphorus using the SPECTRAmax PLUS microplate spectrophotometer: choice of microplate, cuvette or test tube assay formats

Liquid Chromatography

LS6500 Scintillation Counting Systems

Application Note. Abstract. Introduction. Experimental

Time-Resolved Liquid Scintillation Counting

Nitric Oxide Synthase Ultrasensitive Colorimetric Assay

Shodex TM ODP2 HP series columns

Introduction to biochemical practicals. Vladimíra Kvasnicová

Nitric Oxide Synthase Colorimetric Non-enzymatic Assay

1/5 Specifications Hidex 300 SLL automatic TDCR liquid scintillation counter

Cation Exchange HPLC Columns

INDBOND 3000 Dry Strength Resin for Paper

RESULTS YOU CAN COUNT ON

NECi Nitrate Kits FAQs

Glossary of Common Laboratory Terms

The Isosorbide Mononitrate Extended-Release Tablets Revision Bulletin supersedes the currently official monograph.

Method Development with ZirChrom's Ion Exchange Phases

PHYSICAL CONSTANTS: MELTING POINTS, BOILING POINTS, DENSITY

Chapter 17: Additional Aspects of Aqueous equilibria. Common-ion effect

11,12-EET/DHET ELISA kit

NANO 243/CENG 207 Course Use Only

We need to find the new concentrations of the species in this buffer system. Remember that we also DILUTED the solution by adding 5.0 ml of the HCl.

Formation of a salt (ionic compound): Neutralization reaction. molecular. Full ionic. Eliminate spect ions to yield net ionic

Non-Interfering Protein Assay Kit Cat. No

Supporting Online Material. On-Chip Dielectrophoretic Co-Assembly of Live Cells and. Particles into Responsive Biomaterials

Experiment 8 - Double Displacement Reactions

A solution is a homogeneous mixture of two or more substances.

High Performance Liquid Chromatography

High Performance Liquid Chromatography

(A) Effect of I-EPI-002, EPI-002 or enzalutamide on dexamethasone (DEX, 10 nm)

6. Extraction. A. Background. (a) (b) (c) Figure 1. Mixing of Solvents

HPLC Columns. HILICpak VT-50 2D MANUAL. Shodex HPLC Columns Europe, Middle East, Africa, Russia

TIME-RESOLVED LIQUID SCINTILLATION COUNTING

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

1. Which substance will conduct the current in the solid state? 1. Diamond 2.Graphite 3.Iodine 4.Sodium chloride.

Buffers Keep the Balance

Counting Solutions LSC Technical Tips from Packard

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Transcription:

MANUFACTURER PRODUCT NAME CATALOG OR PART NUMBER Amersham BCS NBCS104 Amersham BCS NA NBCS204 Beckman Ready Safe Scintiverse BD Cocktail 60803 ScintiSafe Econo 1 45345 ScintiSafe Econo 2 45346 ScintiSafe Econo R 45347 ScintiSafe 30% 45348 ScintiSafe Gel 45349 158735 141349 SX18 250 SX18 4 SX20 5 SX20 SAMPLE SX20-4 SX20-500 SX21 5 SX21 SAMPLE SX22 5 SX22 SAMPLE SX23 5 SX23 SAMPLE SX24 5 SX24 SAMPLE USES RECOMMENDED BY MANUFACTURER Designed for counting a wide variety of aqueous, inorganic, and organic samples at high capacities. Efficient counting of nonaqueous Multipurpose with high counting efficiency. Universal cocktail for aqueous, non-aqueous, and emulsion counting systems. Best at ambient temperatures for aqueous samples, dilute salt and buffer solutions, acids and bases, density gradients. As for ScintiSafe Econo 1, but performs well above and below ambient temperatures. 100% organic samples, dry filters, as an alternative to Toluene/PPO. High efficiency for swipe tests, dilute salt and buffer solutions, tritium counting. Suspension particle counting, TLC scrapings, soil samples, density gradients, biological

ScintiSafe Plus 50% SX25 5 SX25 SAMPLE Large volumes of aqueous sample, miniaturization, strong alkaline samples, wet filter counting for receptor binding assays. ICN EcoLume 880020 Aqueous and organic samples such as deionized water, phosphate buffered saline, PBS with gelatin or BSA, sucrose gradients, salt solution, 0.1N HCl, 0.1 N NaOH, etc. ICN EcoLite(+) 882453 Exceptional water and salt holding characteristics, and for difficult to count RIA samples, basic samples, phosphate buffers, and biological fluids. High H-3 and C-14 counting efficiencies. Gelling cocktail with ICN Universol ES 882470 physical characteristics of "triton and toluene" type cocktails. One-step counting of ICN CytoScint ES 882475 filters, TLC scrapings, and samples solublized in hyamine hydroxide. ICN BetaMax ES 882480 Beta particle counting in non-aqueous samples, samples dried on solid supports, and organic samples extracted from aqueous mixtures. National Diagnostics Ecoscint LS-271 Aqueous and nonaqueous

National Diagnostics Ecoscint A National Diagnostics Ecoscint O National Diagnostics Ecoscint H National Diagnostics Uniscint BD National Diagnostics Monoflow 5 Ultima Gold LS-273 LS-274 LS-275 LS-276 LS-285 6013329 High efficiency for aqueous samples, resistance to photo- and chemiluminescence, biological samples, acrylamide gel slices. Non-aqueous samples, lower background, improved quench resistance compared with non biodegradable solutions. High efficiency for aqueous sample volumes under 10% of total sample volume, resistance to photo- and chemiluminescence, biological samples, acrylamide gel slices. Accommodates high salt and buffer samples, nongelling, suitable for use in on-line HPLC flow detectors. Nontoxic, biodegradable scintillator for flow detectors (ratios of 3:1). Very high counting efficiency, high capacity, for aqueous or nonaqueous samples, high quench resistance. Ultima Gold XR 6013119 Extended range of sample holding capacity, high quench resistance, high counting efficiency.

Ultima Gold LLT 6013377 (4 x 2.5 liters) High water capacity, high counting efficiency, very low background levels, for bioassay of urine, high heavy metal sample capacity. Ultima Gold MV 6013329 Fast and easy sample mixing, high counting efficiency, ideal for counting small volumes, vortexing and counting wet glass fiber filters. Ultima Gold F Ultima Gold AB 6013179 6013309 High counting efficiencies for dried filters, filter mats and organic samples, alpha and beta LSC counting. Excellent alpha/beta discrimination, excellent for strong mineral acids, high quench resistance, high sample capacity. Opti-Fluor 6013199 Multi-purpose cocktail, low photo and chemiluminescence. Opti-Fluor O Poly-Fluor Ultima-Flo M 6013339 6013279 6013579 6013572 (20 liters) Non-aqueous organic Economical sample counting. Multi-Purpose flow cocktail, high counting efficiency, low viscosity, non-gelling. / Ultima-Flo AF 6013589 Specifically formulated for ammonium formate, high counting efficiency, low viscosity, non-gelling.

Research Products Bio-Safe II 111195 111196 Aqueous solutions, salt/buffer solutions, biological materials, organic solutions, wet filters. Research Products Bio-Safe NA 111198 111199 Highest efficiency when counting organic miscible samples and dry filters. Research Products Econo-Safe 111175 111176 Wallac OptiScint HiSafe II 1200-434 Wallac OptiPhase HiSafe 2 1200-436 Wallac OptiPhase HiSafe 3 1200-437 General purpose cocktail for aqueous and nonaqueous Suitable for all organic General purpose cocktail with a moderate to high sample holding capacity for a wide range of aqueous and nonaqueous solutes. Capable of handling a broad range of solutes, very high level of sample acceptance particularly for high ionic strength solutes. Wallac OptiPhase Hi-Load 1200-438 No description available Wallac OptiPhase SuperMix 1200-439 Wallac OptiPhase TriSafe 1200-440 Wallac Betaplate Scint 1205-440 For use with microtitration plates. High solute uptake and low background, ideal for extended counting times. For samples harvested or spotted onto filter membranes.