CARBOXEN 564 A NEW CARBON MOLECULAR SIEVE SORBENT USED FOR RADON AND THORON MONITORING

Similar documents
RESPONSE OF A RADON CHARCOAL CANNISTER TO CLIMATIC AND RADON VARIATIONS IN THE INTE RADON CHAMBER. A. Vargas, X. Ortega, I.

ALPHA AND GAMMA SPECTROSCOPY METHODS FOR THORON PROGENY IMPLANTED IN GLASSES AND OTHER MATERIALS

Radon Determination by Activated Charcoal Adsorption and Liquid Scintillation Measurement. Canoba, A.C.; López, F.O. and Oliveira, A.A.

Results of the 2015 national indoor radon intercomparison measurements in Serbia

RADON EQUILIBRIUM MEASUREMENT IN THE AIR *

INFLUENCE OF EXPOSURE GEOMETRY ON THE RESPONSE OF CR39 SSNT RADON DETECTORS *

The LSC Approach to Radon Counting in Air and Water

Development And Testing of a Thermoluminescent Dosemeter for Mixed Neutron-Photon-Beta Radiation Fields

Evaluation Model of Atmospheric Natural Radiaoctivity Considering Meteorological Variables

Study of Radium and Radon Exhalation Rate in Some Sand Samples Using Solid State Nuclear Track Detectors

Experiment Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado

A Simple Measurement Technique of the Equilibrium. Equivalent Thoron Concentration with a CR-39 Detector

Measurement of radon ( 222 Rn) and thoron ( 220 Rn) concentration with a single scintillation cell

DUNPL Preliminary Energy Calibration for Proton Detection

Adsorption of Radon at different gamma energies using different activated carbon

SECTION 8 Part I Typical Questions

CALIBRATION OF INSTRUMENTS MEASURING RADON OVER A LARGE ACTIVITY RANGE. N. Michielsen, V. Voisin

Natural Radiation K 40

DYNAMICS OF OUTDOOR RADON AND THORON PROGENY CONCENTRATIONS IN SOME GEOGRAPHICAL AREAS OF ROMANIA *

Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado

A STUDY OF RADON ADSORPTION ON ACTIVATED CARBON AS A FUNCTION OF TEMPERATURE

A COMPUTER PROGRAM FOR THE DECONVOLUTION OF THERMOLUMINESCENCE GLOW CURVES K. S. Chung 1,, H. S. Choe 1, J. I. Lee 2, J. L. Kim 2 and S. Y.

Journal of American Science 2013;9(12)

Quality Assurance. Purity control. Polycrystalline Ingots

Radionuclide Imaging MII Detection of Nuclear Emission

A coincidence method of thorium measurement

COMBINED LSC-BASED METHOD FOR RADON IN AIR MEASUREMENTS

International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: Vol.8, No.3, pp , 2015

THE ANNUAL EFFECTIVE DOSE FROM NATURAL RADIONUCLIDES SOIL SURFACES OF UZHGOROD AREA

STUDIES ON THE AEROSOL RADIOACTIVITY LEVEL AND AIR QUALITY AROUND NUCLEAR RESEARCH INSTITUTE AREA

Measurement of indoor radon, thoron and annual effective doses in the some dwellings of Jaipur city, Rajasthan, India

Ion Chamber. Radon Measurements. Theremino System Rev.1. Theremino System IonChamber_ENG Page 1

Project Memorandum. N N o. = e (ρx)(µ/ρ) (1)

Vapor Intrusion Sampling Options: Performance Data for Canisters, Badges, and Sorbent Tubes for VOCs

Thermoluminescence Properties of Local Feldspar from Gattar Mountain Area

Radon Activity And Exhalation Rate In Building Materials From Crushing Zone Of Shivalik Foothills In India

Introduction to Environmental Measurement Techniques Radioactivity. Dana Pittauer 1of 48

Measurement of Radon and Uranium Concentrations and Background Gamma Rays at the University of Baghdad -Jadiriyah Site

WM2018 Conference, March 18-22, 2018, Phoenix, Arizona, USA. PVT and LaBr3(Ce)-based Radon Express Analyzers 18164

Chem 481 Lecture Material 3/20/09

TRACERLAB. Natural Radiation, the Determination of Radon, Thoron and it s Progenies. Quality and Technology - Made in Germany - TRACERLAB GmbH

First tests of the big volume ultra low background gamma spectrometer

ATOMIC PHYSICS Practical 11 STUDY OF DECOMPOSITION OF RADIOACTIVE RADON 1. INTRODUCTION

NUCL 3000/5030 Laboratory 2 Fall 2013

Ultra-Low Background Counting and Assay Studies At SNOLAB

Multilayer Nuclear Track Detectors for Retrospective Radon Dosimetry

Journal of Radiation Protection and Research

Radon Emanation Testing for DRIFT

Radon escape from mine tailings dams. Robbie Lindsay + Joash Ongori (PhD student) Co-authors Prof Richard Newman/Dr Peane Maleka

Estimating the natural and artificial radioactivity in soil samples from some oil sites in Kirkuk-Iraq using high resolution gamma rays spectrometry

Application Note. The Continuous Air Monitoring (CAM) PIPS Detector Properties and Applications

Radioactivity is the spontaneous disintegration of nuclei. The first radioactive. elements discovered were the heavy atoms thorium and uranium.

Characterising NORM hazards within subsea oil and gas facilities. Daniel Emes SA Radiation

The Pharmaceutical and Chemical Journal, 2017, 4(6): Research Article

Low Background Counting At SNOLAB

Characterization of Low-Energy (6-30 kev) Response of Polish TLDs (MTS-N, MCP-N) with Synchrotron Radiation and Determination of Some TLD Quantities.

Natural Radiation Map of the Sudan

Chapter Seven (Nuclear Detectors)

Workshop on Understanding and Evaluating Radioanalytical Measurement Uncertainty November The Romanian underground laboratory

International Journal of PharmTech Research CODEN (USA): IJPRIF, ISSN: , ISSN(Online): Vol.9, No.9, pp , 2016

Radioactivity measurements and risk assessments in soil samples at south and middle of Qatar

EXPERIMENTAL TECHNIQUE TO MEASURE THORON GENERATION RATE OF BUILDING MATERIAL SAMPLES USING RAD7 DETECTOR

REPORT RESULTS OF RADON DIFFUSION COEFFICIENT (SAMPLES SYNTHESIA O-14015)

THE COMPTON EFFECT Last Revised: January 5, 2007

Beta Spectrum. T β,max = kev kev 2.5 ms. Eγ = kev

Level of Radionuclide Contents in Surface Water from Shutt- Al-Arab River in Basrah Governorate, Iraq

Keywords: experimental verification; LiF:Mg,Cu,P; lithium fluoride; radial dose distribution

Chapter 10. Table of Contents. Section 1 What Is Radioactivity? Section 2 Nuclear Fission and Fusion. Section 3 Nuclear Radiation Today

Committed Effective Dose from Thoron Daughters Inhalation

J. Rad. Nucl. Appl. 2, No. 1, (2017) 11 Journal of Radiation and Nuclear Applications An International Journal

Ultra-Low Background Measurement Capabilities At SNOLAB

Electrical conductivity of air related to ion pair production rate from radon and its progeny concentrations in dwellings of Mysore city

MATHEMATICAL MODEL OF RADON ACTIVITY MEASUREMENTS

Uncertainty in radon measurements with CR39 detector due to unknown deposition of Po

Particle Size of Radioactive Aerosols Generated During Machine Operation in High-energy Proton Accelerators

Volume 1 No. 4, October 2011 ISSN International Journal of Science and Technology IJST Journal. All rights reserved

1 cm. Cu electrode. Ge crystal. end cap. Dead layer. crystal cup

ARMUG New CAM Developments. Arran Morgan MSc Physicist

Dosimetry of ionizing radiation

Alpha-particle Stopping Powers in Air and Argon

RADIOACTIVITY. Nature of Radioactive Emissions

Natural Rock Sample Manual

GLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY

Study Guide 7: Ionizing Radiation

GAMMA RAY SPECTROSCOPY

NORM and TENORM: Occurrence, Characterizing, Handling and Disposal

Measurement of Gamma Emitting Radionuclides in Environmental Samples of Talagang Tehsil-District Chakwal

Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics

LAAPD Performance Measurements in Liquid Xenon

General Physics (PHY 2140)

Available online at ScienceDirect. Physics Procedia 80 (2015 )

Real-Time Detection: From Gisclard et al.: A Simple Device for Air Analysis. AIHA Quarterly, 14(1):23-25 (1953)

Physics of Radioactive Decay. Purpose. Return to our patient

RADIOECOLOGICAL PROBLEMS IN HOME BUILDING IN THE CITY OF NOVI SAD

Evaluation and analysis of 226 Ra, 232 Th, 40 K and radon exhalation rate in various grey cements

Influence of volcanic subsoil on indoor radon levels in Olot (NE Spain)

1. Introduction. Etim I.P. 1, William E. S. 2, Ekwe S.O. 3. Licensed Under Creative Commons Attribution CC BY

Analyzing Radiation. Pre-Lab Exercise Type of Radiation Alpha Particle Beta Particle Gamma Ray. Mass (amu) 4 1/2000 0

RADIATION MEASUREMENTS AT THE CAMPUS OF FUKUSHIMA MEDICAL UNIVERSITY THROUGH THE 2011 OFF THE PACIFIC COAST OF TOHOKU EARTHQUAKE AND

12/18/2016. Radioanalysis Laboratory Capabilities and Issues. Eleventh Annual Radiation Measurement Cross Calibration Workshop RMCC XI

Transcription:

CARBOXEN 564 A NEW CARBON MOLECULAR SIEVE SORBENT USED FOR RADON AND THORON MONITORING C. Cosma 1, T. Jurcut 2, V. Benea 1, M. Moldovan 1, Alida Timar 1 1 Faculty of Environmental Science, Babes-Bolyai University, Cluj-Napoca, Romania 2 Faculty of Sciences, University of Oradea, Oradea, Romania Abstract The possibility to combine the track-etched CR-39 or Makrofol detectors with charcoal to increase the detector sensitivity was shown in the last years. Special requests are necessary in the case of a personal dosimeter when the detector must be active only during working activity. Regarding the combination of charcoal with TL detectors our preliminary investigations indicate that the TLD intensity in normal indoor air (~80 Bq/m 3 ) is about two times higher for TLD + charcoal in comparison with simple uncombined TLD. This paper presents a study on the charcoal combined with TLDs and some remarks about charcoal properties. The results show a linear dependence between TLD+charcoal signal versus radon air concentration. Using Carboxen 564, a special carbon molecular sieve, the detection limit for indoor radon can be lowered under 60 Bq/m 3 /day, rather small and promising to be used for a radon personal dosimeter at workplaces Key words: Carboxen-564, charcoal, radon, termoluminescence, dosemeter INTRODUCTION Radon and radon progeny exposure is the most important source of irradiation for public [1]. A lot of investigations have and are being performed in the indoor environment (houses, schools, mines) and also for some workplaces. The most commonly used integrating radon detectors up to now are the activated charcoal and track-etched detectors. The first one is used for short term measurements, typically with an exposure time of a few days and the radon air concentration is found from the radon charcoal content measured by gamma spectrometry [2-4]. The second detector type is exposed for a few months and then chemical and/or electrochemical etched to count the alpha tracks [5]. Because of its large adsorption ability, charcoal is often used to collect radon. The principle of the charcoal method is based on the measurement of the gamma emission of radon progeny adsorbed in the charcoal by means of gamma rays detectors such as sodium iodide (NaI(Tl)). Some of those detectors are equipped with a diffusion barrier between the charcoal and the air; therefore the radon adsorbed by the charcoal is proportional to the radon concentration in the air.

The possibility to combine the track-etched detectors CR-39 with charcoal for the growth the detector sensitivity was shown in the last years [6-8]. Special requests are necessary in the case of a personal dosimeter when the detector must be active only during working activity. To find the best combination between charcoal and TLD a complete relevant study is requested. A lot of data for 20 different sorts of activated charcoal were presented by Scarpitta [9-10], as a study in the radon chamber for 2.8 days at 14% relative humidity (RH) using open-faced canisters of 1-1.5 cm thickness of charcoal bed. For some charcoals having better characteristics for radon adsorption, were also made measurements at 43%, 51%, and 70% RH. The response of charcoal to humidity variations using both diffusion and convection of radon also influence of the desiccant on radon adsorption has been investigated [11]. TLDs have only a limited utilization in radon dosimetry because they are generally sensible to whole spectrum of natural radiation: cosmic, terrestrial or gamma-beta radioactivity of building materials. But they can be used for radon progenies measurement. The TLD type contains an airsampling pump that draws a continuous uniform flow of air through a detector assembly. The detector assembly includes a filter and at least two TLDs. One TLD measures the radiation emitted from radon decay products collected on the filter, and the other TLD is used for a background gamma correction. Analysis of the TLDs are performed using a TLD reader. Interpretation of the results of this measurement requires a calibration for the detector and the analysis system based on exposures to known concentrations of radon decay products [12]. Stranden [13] shown that charcoal detectors can be equipped with a TLD chip inserted into the charcoal, the radon concentration is then determined using a TLD reader. Those detectors are convenient for the determination of indoor radon concentrations because of their low cost, the short time of exposure required and their small size. The main characteristics involved in the design of a combined Charcoal-TLD detector are: the background radioactivity of the charcoal, the adsorption and desorption time, directly connected with thickness of charcoal bed, the k value of adsorption coefficient and the breakpoint of the charcoal which is directly related with the water mass in charcoal. In the case of an important quantity of radon adsorbed in charcoal, the achievement of this breakpoint leads to the substitution of radon with water vapors, diminishing drastically the adsorbed radon by charcoal [9]. Recently, Scarpitta, [14] made a comparative study using the best known charcoal, Calgon PCB, and a new charcoal sort, Carboxen 564, 6

produced by Supelco Inc, Belafonte, USA. It was found that the last have superior characteristics regarding the adsorption properties of the radon especially in thin layers [15]. Using this charcoal and Makrofol track detectors a radon dosimeter for work places exposure was proposed by C. Cosma and A. van Deynse [16]. Very recently studies about a TLD-Charcoal dosimeter were made by a Polish team [17-18], which used a very sensitive TLD chip, namely MCP-N (LiF: Mg, Cu, P), produced in their laboratory. In the present work are presented our results obtained using the abovespecified TLD chips (LiF: Mg, Cu, P) and a sort of Romanian charcoal of which properties were studied in the radon laboratory from Ghent University [8,15,16]. Comparative studies between Carboxen 564 and other charcoal proprieties are also presented folowing measurements in our laboratory. These sensitive chips coupled with Carboxen 564 can improve the detection limit, to obtain a personal radon dosimeter possible to be used for work place exposures. BACKGROUND THEORY For the equilibrium adsorption of radon by charcoal [4] one can write: A= k ρ C (1) where A and C are respectively the activity concentrations of radon in the charcoal and in the air (Bq/m 3 ), k is the adsorption coefficient (m 3 /kg) and ρ is the bulk density of charcoal (kg/m 3 ). From the data reported in the literature (ρ 500kg/m 3 and k 4m 3 /kg) it can calculate that the radon concentration in the charcoal is approximately three orders of magnitude higher than in the air. For practical use of a dosimeter based on the combined TLD-charcoal technique the time of adsorption and desorption from the charcoal bed is a very important parameter. This constant can be measured and a strong dependence of the thickness of the charcoal bed was observed [9-10]. The quickness of adsorption is characterized by build-up time constant (BUTC) and can be determined from: BUTC=t s /ln(k max /(k max -k(t s )) (2) where k(t s ) is the adsorption coefficient for t s, k max being the equilibrium k coefficient utilized in equation (1) and t s is the time required to achieve 67% of k max. The desorption is characterized by desorption time constant (DTC) related of the t 1/2 time (the desorption of a half radon from charcoal) as: 7

DTC=t 1/2 /ln2 (3) These two constants (BUTC and DTC) measure the radoncharcoal inertia, being very important parameters for designing a simple dosimeter or a personal dosimeter. An important characteristic of charcoal is the breakpoint [14]. The breakpoint represents the mass of adsorbed water vapors which if is surpassed the water molecules substitute the radon atoms from the inner structure of charcoal. As results the k coefficient drastically decreases. The background radioactivity of charcoals also can influence the signal induced in TLD chip, especially at low radon concentrations and for long time exposure. EXPERIMENTAL METHOD The radon dosimeter is based on radon adsorption on activated charcoal. By placing TLD chips inside an open charcoal container, the beta and gamma radiation from radon daughters, produced by the decay of adsorbed radon, is detected continuously during the exposure time [13]. The adsorption constant, also the background radioactivity of the different charcoals was measured by gamma spectrometry using a Ge calibrated detector. For the radon evidence the main two photo- peaks of the radon progeny (609 kev and 352 kev) were used. Radon concentration in the air was measured using a Radim device [18]. The sample Nr. 7 (Ro-2F, from Table 1) was measured in Ghent and remeasured in our laboratory. It is a Romanian sort of charcoal (CASS-Buzau) and this sort was used in the first experiments. Because, for low radon concentration the charcoal radioactivity itself can contribute to the TLD signal, we present in Table 2 the background radioactivity of different types of charcoal in comparison with Carboxen 564. A special device for rapid and complete charcoal cleaning (complete activation) used in our work is shown in Fig.1. This device is a brass cylindrical vessel of 0.8 l connected to a vacuum pump and during degassing time the temperature is maintained at 100 C (boiling water). After 15-20 min of pumping the charcoal is removed and it radioactivity after 3-4 hours (radon progeny disintegration) shows the background activity of charcoal. The Polish TLD chips, namely MCP-N (LiF: Mg, Cu, P) type, 3 mm in diameter and 1.2 mm thick were installed in the center of two kinds of charcoal plastic canisters of 10 ml and 30 ml in volume. These plastic canisters have many holes symmetrically delivered to allow easy entrance of 8

radon gas. The canisters were exposed typically for 120 h in a radon chamber (58 l) at four different concentrations: 850 Bq/m 3 ; 1240 Bq/m 3 ; 1970 Bq/m 3 and respectively 3260 Bq/m 3, Fig.2. These radon concentrations were continuously measured with the Radim monitor device inside [18]. After exposure, the reading of TLD was made with Harshaw - 2000 device. Fig.1. The device for charcoal degassing. Fig. 2. The radon chamber and Radim device RESULTS AND DISCUSSION In Table 1 are shown the adsorption constants for eleven charcoal sorts. For Carboxen 564 two charcoal thickness (2 mm and 3 mm) were used and in each case five measurements were performed. As it results from this table the errors in adsorption constant are smaller as 7-8% and Carboxen 564 has the best adsorption properties. In the table is marked with bold letters the charcoal used by us (Nr.7-Ro-2F), in our preliminary measurements. By using Carboxen 564 instead of Ro-2F the sensibility of method can increase about five times. 9

Table 1. The equillibrium adsorption constants (k) measured at 120 Bq/m 3 and 60%RH Nr. crt. Type of charcoal Nr. samples 10 Gamma activity (counts/g) k (m 3 /Kg) 1 Ro-1G 2 83 4.02 2 George 4 56(15%) 2.75 3 CalgonBPL 3 56(16%) 2.75 4 CalgonPCB 3 75(10%) 3.61 5 Norit R1 4 61(12%) 2.9 6 PZ 1 25 1.52 7 Ro-2F 4 20(20%) 1.42* 8 Merck 1 21 1.05 9 ART2515 1 19 0.98 10 Carboxen (2 mm) 5 140(8%) 6.92 11 Carboxen (3 mm) 5 148(7%) 7.1 *Remeasured in our laboratory In Table 2 one can see the background radioactivity of some charcoals measured with a Ge high resolution spectrometer after a very good degassing using the device from Fig.1. As it can see from this table Carboxen 564 has a very low background closed of Ge background both for total radioactivity (columns 2 and 3) and the for radium content (columns 4 and 5). The charcoal Ro-2F have the background with 10% higher, especially due to radium and cesium content. George type of charcoal (obtained from coconut shell) also have a low background radioactivity but adsorption constant is three time smaller (Table 1). Table 2. Gamma background of different charcoals. Type E γ > 90 kev Photopeak area (A) (B) (609 (352 Obs. kev) kev) CalgonPCB - 107976 48 92 Low activity George 101380 100800 49 52 Background Norit R1 112600 109263 180 250 226 Ra, 137 Cs Ro-1G 121280 117500 233 346 Much 226 Ra Ro-2F 109700 110400 161 201 137 Cs, 226 Ra Merck - 104200 - - Low activity

137 Cs PZ - 108300 - - Carboxen 564 100720 100630 48 65 Background Ge backgr. 100700 100600 30 54 The results for 4 chips simultaneous exposed in the radon chamber (5 days) at 1240 Bq/m 3 in V 1 (30 ml) and V 2 (10 ml) canisters are shown in Table 3. The TLD intensity of background was for these chips B=4ηC. As can see, the reproducibility (standard deviation) is better as 10%. If we consider the detection limit as B 1/2 =2ηC the minimum detectable concentration for one day exposure is about 400 Bq/m 3. The result recently obtained by Bogacz et al. [17] is 300 Bq/m 3 for the same time of exposure. Considering usage of Carboxen 564, the limit of detection can be five times smaller, therefore 60 Bq/m 3 /day, rather small and promising to be used for a radon personal dosimeter at workplaces [16]. Another experiment was the exposure of 3 TLD + charcoal and others 3 TLD only chips in the laboratory room (about 60 Bq/m 3 ) for 5 days. The average corrected background signal was two times higher in the case of TLD + charcoal sets. In Fig.3 are presented the results obtained for the five days exposure of TLD + charcoal in the radon chamber at four different concentrations. A linear dependence between the signal intensity and radon content in the radon chamber can be seen both for V 1 and V 2 sample types as in paper [17]. Although V 1 canister is three times larger as V 2 it can see from Table 3 and Fig.3 that the intensity of the signal is only with 27% higher. Table 3. Four TLD + charcoal canisters exposed at 1240 Bq/m 3 for 5 days Chip Standard P number 1 P 2 P 3 P 4 Mean deviation TLD V 1 (ηc) 33.7 32 29.1 29.7 31.16 2.12 signal V 2 (ηc) 24.1 27.2 25.3 21.7 24.57 2.29 11

- V 1 (40 ml) - V 2 (10 ml} Fig.3. Signal intensity of TLD + charcoal versus concentration in radon chamber CONCLUSIONS A liniar dependence between the signal intensity and radon content in the radon chamber was observed, both for V1 and V2 sample types. Growing the charcoal volume over 40 ml have not important influence on the sensivity increasing The minimum detectable concentration (LLD) for one day exposure is about 400 Bq/m3 in the case of Ro-1F charcoal. Considering usage of Carboxen 564 the limit of detection can be five times smaller, that is 80 Bq/m3/day, rather small and promising to be used for a radon personal dosimeter at workplaces. REFERENCES 1. D. Bodansky, M.A.Robkin and D.R.Stadler Indoor Radon and its Hazards, University of Washington Press, Seattle and London (1989) 2. A.C. George, Passive integrating measurement of indoor radon using activated carbon. Health Phys. 46, 867-872 (1984) 3. H.M. Prichard and K. Marien, A passive diffusion radon sampler based on activated carbon adsorption. Health Phys. 48, 797-801 (1985) 12

4. B.L. Cohen and E.S. Cohen Theory and practice of radon monitoring with charcoal adsorption. Health Phys. 45, 501-508 (1983) 5. L.Tommasino, Radon monitoring by alpha track detection. Nucl.Tracks Radiat.Meas, 17, 43-48 (1990) 6. T. Sutej, R. Ilic and M. Krizman A new technique for radon measurement based on a combination of a track-etch detector and activated charcoal. Nucl. Tracks Radiat. Meas. 19, 423 (1991) 7. T. Sutej Sensitivity of a combined charcoal and track-etched technique for 222-Rn. Radiat. Protection Dosim. 56, 255-258 (1994) 8. C. Cosma, A. Van Deynse, A. Poffijn, Studies on Radon Adsorption Characteristics of Different Charcoals used as Amplifiers for Track detectors, Radiation Measurements, 31, 351-354 (1999) 9. S. C. Scarpitta and N.H. Harley, An improved 222-Rn canister using twostage charcoal system. Health Phys. 60, 177-188 (1991) 10. S.C. Scarpitta, Optimum 222-Rn charcoals. Health Phys. 62, 576-580 (1992) 11. Helene Climent, Performance of radon detectors in the environment. Human Radiation Environment Division, NIRS, guest08@nirs.go.jp 12. http://www.epa.gov/radon/pubs/devprot4.html Indoor Radon and Radon Decay Product Measurement Device Protocols Section 3: Indoor Radon Measurement Device Protocols 13. E. Stranden, A.K. Kolstad and B. Lind, Passive Integrating Radon Dosimeter Combining Activated Charcoal and TLD, Radiat. Prot. Dosim. 5, 241-245 (1983) 14. S. C. Scarpitta, A new beaded carbon molecular sieve sorbent for 222- Rn monitoring Health Phys. 70, 673-679 (1996) 15. A. Van Deynse, C. Cosma, A. Poffijn, A radon Dosimeter Based on Makrofol Track and Charcoal Adsorption. Radiation Measurement, 31, 328-344 (1999) 16. A. Van Deynse, Development of a radon personal dosimeter, Thesis, Ghent University (2002) 17. J. Bogacz, J. Mazur, J. Swako, M. Budzanowski and P. Olko, MCP-N (LiF: Mg, Cu, P) TLDs for Radon Measurements with Charcoal, Radiat. Prot. Dosim. 101 (1-4), 267-270, (2003) 18. J. Plch, Radim-2P Detector, Manual for operating, Jiri Plch M Eng. SMM Prague (1997) 13