The sercon group Isotope Ratio Mass

Similar documents
20-22 ISOTOPE RATIO MASS SPECTROMETER

IRMS. perspective. Isotope Ratio Mass Spectrometry.

PERSPECTIVE STABLE ISOTOPE RATIO MS

PERSPECTIVE STABLE ISOTOPE RATIO MS

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

HIGH PERFORMANCE MASS SPECTROMETERS FOR EARTH AND PLANETARY SCIENCE

Defining quality standards for the analysis of solid samples

HELIX MC Plus. Static Vacuum. ARGUS VI Thermo Scientific HELIX MC Plus Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

Thermo Finnigan LTQ. Specifications

Hiden HPR60 Molecular Beam Mass Spectrometer System

ICP-MS. High Resolution ICP-MS.

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Mass Spectrometers. for Surface Analysis SURFACE ANALYSIS

Finnigan LCQ Advantage MAX

10/8/2013. Alternatives to Mass Spectrometry and Some Real-time Monitoring Measurements. Project Driven Tasks -- Process Gas Measurements

Translational Biomarker Core

Ion Pump Applications

Product Description and Specification

Catalysis CAPABILITIES

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Thermo Scientific 253 Plus 10 kv Isotope Ratio MS. Utilize the Gold Standard. in isotope ratio MS. Robustness Sensitivity Precision

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Petrochemical. Transformer Oil Gas Analysis - TOGA

vacuum analysis plasma diagnostics surface science gas analysis

Extrel is widely respected for the quality of mass spectrometer systems that are

Thermo Scientific DELTA V Advantage DELTA V Plus

Vacuum Pumps. Two general classes exist: Gas transfer physical removal of matter. Mechanical, diffusion, turbomolecular

ICP-MS. plasma 17OO. High Resolution Multi-Collector ICP-MS.

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz

of mass spectrometry

Noble Gas Mass Spectrometer

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

Hiden SIMS Secondary Ion Mass Spectrometers. Analysers for surface, elemental and molecular analysis

Ultra-High Vacuum Technology. Sputter Ion Pumps l/s

Agilent G2350A Atomic Emission Detector (AED)

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

costech instruments ECS 4010 Elemental Combustion System CHNS-O

Hiden CATLAB Systems Microreactor for Catalysis Studies & Thermal Analysis

High-Pressure Volumetric Analyzer

Courtesy of ESS and TheRGA web pages part of a series of application and theory notes for public use which are provided free of charge by ESS.

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219

Water & Vapor Sorption

BioDrop DUO dsdna Application Note

MM 2. Innovation with Integrity. The new Generation of Mobile Mass Spectrometers. Defence CBRNE

High-Performance Continuous Flow Chemistry Systems. Robust Accurate Flexible Safe

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

Thermo Scientific GasBench II

Magnetic Property Measurement System

The Claviature of Gas Analysis

THE APPLICATION OF PROCESS MASS SPECTROMETRY TO FUMED SILICA PRODUCTION

Approval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

Thermo VG PQ EXCELL INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER

ChromTech HPLC System

ACCELERATOR MASS SPECTROMETRY AT THE LUND PELLETRON ACCELERATOR

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

novaa 800 D Atomic Absorption Spectrometer

Agilent G3212 GC-APCI Source

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Prima PRO Process Mass Spectrometer

The Vacuum Sorption Solution

Everyday NMR. Innovation with Integrity. Why infer when you can be sure? NMR

ICPMS Doherty Lecture 1

TO-15 Checklist Determination of VOCs in Air by GC-MS

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

Extrel Application Note

Introduction to GC/MS

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

SNMS. SNMS Applications. Combined SIMS and SNMS

The DialPath Solution an Easier Way to Analyze Liquids By FTIR. Yanqia Wang, Ph.D. Application Engineer - FTIR Agilent Technologies May 7, 2015

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

SOPHISTICATED DESIGN, INTUITIVE OPERATION, RESEARCH-GRADE RESULTS

CHEMISTRY WORKSTATION. The power of proven quality GIVING YOU PEACE OF MIND

DI 3500 Discrete Aoalvzer

VUV ANALYTICS VGA-100 GC DETECTOR Gas Chromatograph Agilent 6890 equipped with a 7683 model autosampler Restek 30m x 0.25mm x 0.

CapaciTorr HV Pumps. making innovation happen,together

Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:

Microscopy Cryostat System

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

THE MEASUREMENT OF SOLAR ULTRAVIOLET SPECTRAL IRRADIANCE PROBLEMS & SOLUTIONS

Compact Orifice FlowMeter

AN ION SOURCE FOR THE HVEE 14C ISOTOPE RATIO MASS SPECTROMETER FOR BIOMEDICAL APPLICATIONS

Automatic titrators, TitroMatic

Making Improvements to Today s Natural Gas Analysis Systems

The solution for all of your

Scientific Instruments for Radiocarbon Dating and Accelerator Mass Spectrometry

473-SHX Dew Point Mirror

Mining Analyzer XRF-3360

high performance OPTIC 3 and applications a total analytical solution

Chapter 13: Partial Pressure Analysis

110 Lowell Rd Hudson, NH USA Tel:

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

The Analyzer. We will deal mainly with magnetic sector instruments here although we will talk briefly about other separation methods later.

Bolometry. H. Kroegler Assciazione Euratom-ENEA sulla Fusione, Frascati (Italy)

HiPace 300 with TC 110, DN 100 CF-F

881 Compact IC pro / 882 Compact IC plus for ion chromatography. Intelligent. Reliable. Precise.

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F

Transcription:

The sercon group 20-22 Isotope Ratio Mass Spectrometer

20-22 Isotope Ratio Mass Spectrometer Product Information Sheet 20-22 ISOTOPE RATIO MASS SPECTROMETER Sercon are dedicated to the design, manufacture and support of Isotope Ratio Mass Spectrometers and their associated sample preparation systems. Backed by a wealth of experience in Isotope Ratio Instrumentation, we provide a full range of services specific to isotope ratio scientists and their applications. Sercon continues the pioneering efforts of Europa Scientific. We are committed to the continuous development of our instrumentation and support services to ensure that ground breaking research needs are met. To ensure that all Europa and Sercon instruments remain fully operational and productive, we offer a range of upgrades and system refurbishments from the Tracermass of the 1980s. All systems can benefit from electronics upgrades, pumping system renewal and ion optics refurbishments. All systems can be brought up to the latest technology. In order to ensure the best possible performance at all times Sercon recommend an annual service of your instrument. Sercon are able to provide rapid on-site response from our team of specialist, experienced engineers. We can provide remote support via telephone and email. All of our users receive training as part of an installation programme. We can also provide further training on specific applications or tailor your course to your analytical needs. purity and are always supplied with the MSDS and Certificate of Analysis. We can supply products of a full range of enrichments and of a large variety of label positions in any quantity you would require. Sercon are global representatives 18 O labelled water, both 10 atom % and 98 atom % used for energy expenditure and PET studies. We ensure that we supply water of the highest quality at a competitive price for your requirements. 20-22 and 20-22 GEO Stable isotope Ratio Mass Spectrometer Combining superior analytical performance with class leading reliability, the 20-22 ensures that all your scientific needs are met. Backed by over 20 years of development with a no compromise approach to its engineering integrity, Sercon provides the ultimate isotope ratio mass spectrometer. This technology is available in both continuous flow 20-22 and dual inlet GEO 20-22 forms to be interfaced with our range of automated preparation units and peripherals. The 20-22 incorporates many high level design features. These include an all stainless steel and metal gasket construction flight tube for ultra-high vacuum purity to ensure minimal backgrounds and zero water contamination. True differential pumping for superior ion transfer through the flight tube from the high sensitivity source to the large dynamic range collectors. The benchtop design with Windows 7 based software ensures a user friendly interface for the most productive IRMS system available. As well as IRMS, Sercon supply consumables and spares of the highest quality for all isotope ratio monitoring mass spectrometers and elemental analysers. Our unique approach of providing the highest possible quality at the most competitive prices means that now all users can benefit from our products. Sercon are the UK distributor for the complete range of isotopically labelled compounds. All products are of the highest possible chemical www.sercongroup.com

Geo 20-22 The Geo 20-22 dual-inlet gas isotope ratio mass spectrometer provides the ultimate precision and sensitivity in stable isotope measurement of a wide range of gases. High precision analysis combined with a wide range of sample preparation modules gives the Geo 20-22 the flexibility to adapt to a wide range of applications. These include geochemistry, hydrology, environmental research, marine and biological sciences. Using all the superior features of the 20-22, combined with an ultra low dead volume dual inlet, the Geo 20-22 is capable of analysing all light gas species from m/z 2 to m/z 96. Provided as a modular benchtop unit, this system can be interfaced with all Sercon peripherals and preparation units including the microcaps for carbonate analysis and WES for water equilibration through the dual inlet. For pure gases the system can be provided with a 10 or 20 port manifold and tube crackers. An extensive range of automated sample preparation units gives the researcher the flexibility to measure 15 N, 13 C, 18 O and 34 S 2 H and other species in a host of applications. It is based on the 20-20, the first analyser that was been purposely designed to measure 2 H by continuous flow methodology. The novel 120 ion optics came out of a design study to find the best geometry for both dual-inlet and continuous flow use and to improve sensitivity for new applications. True stigmatic focusing results in high sensitivity. Novel ion optical design results in an instrument having high dispersion with a short ion path length. This gives exceptionally high stability and has the distinct advantage of having very low abundance sensitivity when being used for continuous-flow. The high dispersion hydrogen spur gives complete separation of HD m/z 3 from He m/z 4 without the need for shields or voltage driven retardation grids (to prevent He from entering the HD collector).

20-22 Isotope Ratio Mass Spectrometer Product Information Sheet features of 20-22 and geo 20-22 120 extended geometry with an 11 cm radius magnetic sector giving an effective 21 cm radius dispersion and double direction focusing. Additional high dispersion long spur with 98.8 sector which creates a distance of 24 cm between the focal points for m/z 2 and 3. This leads to an abundance sensitivity at m/z 3 of <1 ppm which eliminates helium tailing in to the D/H collector. Truly universal Faraday triple collectors for simultaneous collection of adjacent masses in the range 28,29,30-64,65,66 with no adjustment of collectors or amplifiers. Additional single Faraday collector and high gain amplifier for m/z 3 on the hydrogen spur. The desired combination of the 4 collectors is selected through the software. Software switchable variable gain amplifiers and 50v amplifier outputs are available as options. Optional extended geometry system to incorporate up to 12 collectors for custom applications. Asymmetric extended geometry to give true stigmatic focussing with twice the dispersion of normal geometry with the same radius sector. True differential pumping by turbo-molecular pumps with a high compression ratio for both He and H 2, to remove the detrimental effect of abundance sensitivity during continuous flow applications and eliminate memory. With a mass range covering 2 to 96 AMU it is suitable for the analysis of light stable isotopes in all the commonly measured gases; H 2, N 2, NO, N 2 O, O 2, CO,, SO and SO 2. Triple port reference gas injection system. Suitable for calibrating each sample, using a reference gas instead of an internal standard and for easy tuning of the mass spectrometer. Size, type and positioning of reference gas pulses are under software control. Data acquisition system uses state of the art highly stable and linear high frequency converters which produce integral slices with zero dead time and quantisation below the beam statistical noise floor at all signal levels. The 20-22 is a bench-top mass spectrometer with built-in continuous flow interface ready to be connected to our automated continuous flow sample preparation modules. Shorter path length than traditional extended geometry to decrease ion/molecule interactions and so ensure 100% transmission through the analyser and a sensitivity which is higher than any other commercial IRMS (<1000 molecules/ion for ). Small analyser footprint and wide flat peak shape reduce the effect of temperature drift therefore removing the need for peak centring during analysis. Design allows greater tolerance of the known variables of ion optics making the manufacture of the analyser more reproducible and less sensitive to magnet positioning. www.sercongroup.com

Specification Geometry Materials Ion source Magnet Resolution Sensitivity Abundance Sensitivity 120 extended geometry with an 11 cm radius magnetic sector giving an effective 21 cm radius dispersion and double direction focusing. Truly universal Faraday triple collectors for simultaneous collection of adjacent masses in range 28, 29, 30-64, 65, 66 with no adjustment of collectors or amplifiers. Additional long spur with 98.8 sector which creates a distance of 24 cm between the focal points for m/z 2 and 3. Additional single Faraday collector for m/z 3. All stainless steel construction with metal gasket seals to ensure ultra clean internal environment. The use of all metal permits bake out of the analyser and negligible water background. Industrial sealing technology (conflat flanges) means no dead volumes within ion optics so eliminating contamination and memory effects. High sensitivity, electron impact, plug-in design. Programmable electromagnet. m m= 90 (N 2 ) 10% valley definition. m m= 40 (H 2 ) 10% valley definition. < 1000 molecules per m/z 44 ion. < 10000 molecules per m/z 2 ion. < 5 ppm for N 2, < 30 ppm for < 1 ppm for H 2 at 4 x10-6 mbar He in continuous-flow mode. < 10 ppm for - dual-inlet mode. Linearity < 0.03 / na at beam intensity of 2 x10-8 A for H3+ <5 ppm / na. Stability < 0.03 ppm/na/hour. Sample Decay Time for a signal of 2E-8 Amps for m/z 44 to decay below 2E-10 Amps when inlet is isolated. Continuous flow mode = 30 seconds Vacuum Mass analyser - truly differentially pumped by 2 x drag stage turbomolecular pumps (70 L/s) backed by two-stage rotary pumps. Ultimate vacuum of 1 x 10-9 mbar. Source pressure monitored by inverted magnetron gauge. (Nb. this configuration is essential for GC-C-IRMS applications). Inlet Zero dead volume capillary interface to allow the use of continuous flow methods e.g. ANCA-MS and GC-C-IRMS. Data acquisition system Data acquisition system uses state of the art highly stable and linear high frequency converters which produce integral slices with zero dead time and quantisation below the beam statistical noise floor at all signal levels. Software Sercon Callisto software. Proprietary operational software for system control and data handling. Fully compatible with all versions of Windows, currently systems are installed with Windows 7. Electronics Sercon System Controller. Flashover-resistant electronics with semiconductors close to ground and isolated from high voltages. Full control of ion source parameters through software and on-board microprocessors. Communication is via USB with PC system. Valve control outputs for 32 valves as standard, can be extended to 64. Four VFC channels for ion beam and other detector readbacks are installed, extendable to eight or twelve depending on system configuration. Refgas Triple-port reference gas injection system to calibrate sample peaks produced by attached continuous flow modules. Fitted with dedicated pneumatic valves and inlet manifold for 3 reference gas bottles. Reference valve array can be expanded to six or more reference gases if required. Basic unit comprises 20-22 mass spectrometer. Fitted with a triple and single collector for 13 C, 15 N, 18 O and 2 H, and electromagnet. Precision Precision analysis will always yield an SD better than presented below for 5 injections of gases at natural abundance. Major beam of 10 nano amps.

20-22 Isotope Ratio Mass Spectrometer Product Information Sheet Gas Reference Gas ( vs Ref) ( 13 C) 0.1 0.06 ( 18 O) 0.1 0.06 N 2 0.1 0.05 SO 2 ( 34 S) 0.1 0.08 H 2 1.0 0.46 Typical Data (from test records) turbomolecular pump (70 L/s). Standard cold finger has a total dead-volume when the sample is isolated of 90 µl. Liquid nitrogen usage is <100 ml per sample. Cold finger takes <2 min to reach minimum temperature from ambient and is easily interchangeable via screw fittings. Bench arrangement allows easy access to the analyser and dual-inlet for easy maintenance, removing the need to disassemble parts of the system while servicing others. The Geo 20-22 has all the features and performance of the 20-22 with extended capabilities that dual inlet provides. The GEO20-22 s low dead-volume dual micro inlet has been designed for high performance, sensitivity, reliability and ease of maintenance by using the most up to date materials and modern precision engineering. A micro cold finger and continuous flow interface are built in as standard features to meet the demands of modern day dual-inlet isotope ratio mass spectrometry. The whole instrument system is driven by Windows compatible software for ease of operation and networking capability Dual micro inlet consisting of twin ultra-low dead-volume, precision machined, five-sided stainless steel blocks (Pentabloc) interfaced to a common changeover valve (COV). Valves are of fail-safe, normally-closed design. Seals are manufactured from Kel-F making them more economical to service than the outdated gold seal design. The COV is a single ultra-low dead-volume fourway valve block which uses the same valve design as the dual-inlet blocks. An additional manual valve is provided to isolate the COV from the bleed pump to facilitate leak checking and allow maintenance without shutting off the vacuum pumps. The PentaBloc dual micro inlet and COV are pumped by a External Precision (σ (n-1))for n=10 from sample manifold (C) 100 0.01 (O) 100 0.03 H 2 200 0.5 Internal Precision 2σ10 for 10 changeovers on gases at natural abundance. Gas Sample Size (bar µl) (C) 100 10 3 (O) 100 10 3 Standard Inlet ( ) 0.01 0.01 0.02 Cold Finger ( ) 0.015 0.015 0.03 N 2 100 0.01 0.01 N 2 20 H 2 200 0.15 SO 2 100 20 0.015 0.015 www.sercongroup.com

Anatomy of a 20-22 Ion Optics Flight Tube All high grade stainless steel construction for ultimate clean construction and no water background. The use of all metal gaskets permits full bake out and prevents blind volumes. This ensures ultra high vacuum (UHV) conditions can be met. UHV conditions are necessary to minimise contaminant masses and stray molecules. Magnet Permanent Magnet provides total stability of the system. High range electromagnet permits the analysis of Hydrogen (m/z 2) to Methyl bromide (m/z 96) Ion Source High sensitivity Nier type electron impact design ensures high ionisation efficiency. Thoriated filament is highly stable and permits analysis of O 2. Modern design concept ensures zero memory effect and permits analysis of SO 2 gas as standard. Self-alignment ensures perfect ion optics. Collectors Universal triple collector of a fully enclosed design eliminates noise and scatter of ions. Dedicated 2HH (m/z 3) detector does not require electrostatic filter or retardation grid due to full spatial separation of He (m/z 4) Pumping True differential pumping ensures the best possible vacuum conditions, higher pressure in the source for sample ionisation with reduced analyser pressure to ensure 100% beam transmission through magnetic sector to the collector.

www.sercongroup.com geo 20-22 dual inlet irms Approx. 160kg 610mm 580mm 810mm 20-22 IRMS Approx. 80kg Power and Gas Requirements 580mm 610mm Power 100-240 VAC Helium 99.998% Compressed Air* 100psi Nitrogen 99.999% Carbon Dioxide 99.999% Hydrogen 99.999% Liquid Nitrogen* 810mm * For GEO 20-22 only. Unit 3B Crewe Trade Park, Gateway, Crewe, Cheshire. CW1 6JT UK Like us on Facebook SerconLimited t: +44 (0)1270 580008 f: +44 (0)1270 252310 e: sales@sercongroup.com Follow us on Twitter @SerconLimited Sercon is ISO 9001:2008 accredited