Noble Gas Mass Spectrometer.

Similar documents
HIGH PERFORMANCE MASS SPECTROMETERS FOR EARTH AND PLANETARY SCIENCE

PERSPECTIVE STABLE ISOTOPE RATIO MS

PERSPECTIVE STABLE ISOTOPE RATIO MS

IRMS. perspective. Isotope Ratio Mass Spectrometry.

ICP-MS. High Resolution ICP-MS.

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

ICP-MS. plasma 17OO. High Resolution Multi-Collector ICP-MS.

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

HELIX MC Plus. Static Vacuum. ARGUS VI Thermo Scientific HELIX MC Plus Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

Noble Gas Mass Spectrometer

of mass spectrometry

AND LIMITATIONS K. BALOGH

Finnigan TRITON Finnigan NEPTUNE. High Resolution Multicollector Mass Spectrometers

Thermo Scientific Neptune XT MC-ICP-MS

The sercon group Isotope Ratio Mass

Thermo Scientific TRITON Thermal Ionization MS. Thermo Scientific NEPTUNE Multicollector ICP-MS. High Resolution Multicollector Mass Spectrometers

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis

Catalysis CAPABILITIES

GSA Data Repository How old is Kīlauea Volcano (Hawai i)? Insights from 40 Ar/ 39 Ar dating of the 1.7-km-deep SOH-1 core M.O. Garcia et al.

Additional Analytical Methods. Detrital zircon samples were collected from nine fine-, medium-, and coarse-grained

- A spark is passed through the Argon in the presence of the RF field of the coil to initiate the plasma

Defining quality standards for the analysis of solid samples

Mass Spectrometers. for Surface Analysis SURFACE ANALYSIS

Hiden HPR60 Molecular Beam Mass Spectrometer System

CapaciTorr HV 200 HIGHLIGHTS

High Resolution Optical Spectroscopy

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Courtesy of ESS and TheRGA web pages part of a series of application and theory notes for public use which are provided free of charge by ESS.

TABLE DR1. SUMMARY OF SHRIMP U-Pb ZIRCON RESULTS FOR SAMPLES D2-83 AND D2-24.

20-22 ISOTOPE RATIO MASS SPECTROMETER

TGA Thermal Gravimetric Analysis

CapaciTorr HV Pumps. making innovation happen,together

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Thermo Finnigan LTQ. Specifications

ELEMENT2 High Resolution- ICP-MS INSTRUMENT OVERVIEW

DI 3500 Discrete Aoalvzer

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

ADVANCED UNDERGRADUATE LABORATORY EXPERIMENT 28 MASS SPECTROMETER

Supporting Online Material for

PARTICLE MEASUREMENT IN CLEAN ROOM TECHNOLOGY

Error Analysis. The big questions are: - What value best represents a set of measurements and how reliable is it?

Finnigan LCQ Advantage MAX

costech instruments ECS 4010 Elemental Combustion System CHNS-O

High-Performance Continuous Flow Chemistry Systems. Robust Accurate Flexible Safe

Atomic Absorption Spectrometer ZEEnit P series

GSA DATA REPOSITORY Topuz et al. ANALYTICAL PROCEDURE

Introduction to Blackbody Sources

novaa 800 D Atomic Absorption Spectrometer

Hiden CATLAB Systems Microreactor for Catalysis Studies & Thermal Analysis

vacuum analysis plasma diagnostics surface science gas analysis

Uncertainty in Measurement of Isotope Ratios by Multi-Collector Mass Spectrometry

dating of geological samples by laser ablation ICPMS

10/8/2013. Alternatives to Mass Spectrometry and Some Real-time Monitoring Measurements. Project Driven Tasks -- Process Gas Measurements

Automated, Turn-key Thermochronology

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization

Metz Syn 10 Reaction Station

Ion Pump Applications

Lecture 5-8 Instrumentation

ICPMS Doherty Lecture 1

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

NEXTorr HV 100 HIGHLIGHTS

Translational Biomarker Core

Hiden SIMS Secondary Ion Mass Spectrometers. Analysers for surface, elemental and molecular analysis

HFM 100 Series. Thermal Conductivity Meter for measurement of insulation and construction materials.

SNMS. SNMS Applications. Combined SIMS and SNMS

Lecture 3 Vacuum Science and Technology

THE APPLICATION OF PROCESS MASS SPECTROMETRY TO FUMED SILICA PRODUCTION

Thermo VG PQ EXCELL INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER

Extrel is widely respected for the quality of mass spectrometer systems that are

HOW ADVANCED PYROMETERS INCREASE THERMAL PROCESS REPEATABILITY AND PRODUCT QUALITY

BALKAN PHYSICS LETTERS Bogazici University Press 15 November 2016 BPL, 24, , pp , (2016)

Determination of Capillary pressure & relative permeability curves

LIBSlab ANALYZERS ANALYZERS

Microscopy Cryostat System

Beam Diagnostics and Instrumentation JUAS, Archamps Peter Forck Gesellschaft für Schwerionenforschnung (GSI)

Using a Research Laboratory for training Students

JARA FIT Ferienprakticum Nanoelektronik Experiment: Resonant tunneling in quantum structures

ICP-Mass Spectrometer

Autoresonant Ion Trap Mass Spectrometer The RGA Alternative

Status of the ESR And Future Options

ionos The most advanced stable isotope software ever created

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

Water & Vapor Sorption

Angular Correlation Experiments

Thermo Scientific 253 Plus 10 kv Isotope Ratio MS. Utilize the Gold Standard. in isotope ratio MS. Robustness Sensitivity Precision

The Claviature of Gas Analysis

Automated Clinical Analyzer

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

Accelerator Mass Spectroscopy

Photoemission Spectroscopy

Improvement of bulk analysis of environmental samples by using a multiple collector ICP-MS

Hidex 300 SL Automatic TDCR Liquid Scintillation Counter

ION Pumps for UHV Systems, Synchrotrons & Particle Accelerators. Mauro Audi, Academic, Government & Research Marketing Manager

Atomic Spectra HISTORY AND THEORY

Header. Volcanic matrix from three basalts and one dacite sample from the Black Mountains and Black Hills, respectively, were separated to perform

The atomic number, Z, is the number of protons in the nucleus. The mass number,a, is the total number of protons and neutrons in the atom.

Survey Meter OD-01 Address: Phone: Fax: URL:

APPENDICES. Appendix 1

TESCAN S New generation of FIB-SEM microscope

Distillation purification and radon assay of liquid xenon

Transcription:

noblesse HR Noble Gas Mass Spectrometer www.cameca.com www.nu-ins.com

Noblesse HR Accurate Noblesse HR can resolve most isobaric interferences to the noble gases, giving more accurate results. In particular, all carbon based interferences to Ar, and the 40 Ar ++ interference to 20 Ne +, may be easily separated. Flexible Noblesse HR has a new design of ion source which allows optimisation of either sensitivity or resolving power, without any moving parts. The instrument s unique, patented, zoom optics allow instantaneous switching between different isotope sets. 02 Reliable The zoom optics permit the detectors to be fixed, greatly enhancing reliability. The sensitivity and resolving power are also adjusted without the complexity of a movable source slit.

Noblesse HR - key features Greatly enhanced resolving power demonstrated separation of H 35 Cl from 36 Ar Up to 5 large discrete dynode electron multipliers for simultaneous measurements of Argon Isotopes Enhanced collector options Zoom Optics for maximum flexibility and reliability Large 55 Volt dynamic range on the Faraday collectors State of the art purpose built electronics Straightforward source filament change Removal of carbon based interferences at all masses Fully bakeable to 300 deg C Intuitive control software 03

Noblesse HR Noble Gas Mass Spectrometer 04

Mass scans showing resolution of 36 Ar and 38 Ar from interferences Mass Spectrometer The Noblesse HR is a single focussing mass spectrometer using a 24 cm radius, 75 degree magnet. The instrument provides good mass dispersion without excessive volume the volume of the popular 1 Faraday 3 Multiplier array is ~1550 cc (without getters). Source The Noblesse HR employs a unique Nier type ion source, which permits adjustment between higher sensitivity and higher resolving power, without using a moveable source slit. The filament can be replaced easily without removing the source and is self-aligning on installation. Variable Dispersion Ion Optics The Noblesse HR uses Nu Instruments unique and patented Zoom Optics system, which enables multi-collection of different sets of isotopes using a fixed collector array. The Zoom Optics allows the dispersion to be changed instantaneously even during an analysis whilst use of a fixed array reduces volumes and greatly increases reliability. The Zoom lenses also perform fine focussing of the ion beam, making adjustable magnet pole pieces a thing of the past. Vacuum System The Noblesse HR is fitted with a 20 l/s ion pump for pump out during normal operation, whilst a 75 l/s Turbomolecular pump and dry backing pump are used to pump the instrument down from atmospheric pressure. The pneumatic valve to the source end ion pump is software controlled. A pneumatic inlet valve is available as an option, for use with an automatic gas preparation system. The instrument is fitted with a getter adjacent to the source; a getter or ion pump can be fitted at the collector. Both getters can be isolated and pumped independently, allowing activation without polluting the mass spectrometer. 05

Noblesse HR Versatile Collector Options Collector Options A key feature of Noblesse HR is the wide range of collector arrays which are offered. These have evolved over the last 10 years, leading to the 5 ion counter array shown below. This provides the ultimate in multicollection capability. All 5 Ar isotopes can be measured simultaneously, with the option to measure 37, 39 and/or 40 on Faradays. All Xe isotopes can be measured in just 3 steps. The detectors are fixed giving greater reliability and the dispersion changed with the unique Zoom Optics. It is possible to switch the beam between Faraday and multiplier, increasing the dynamic range for isotopes such as 40 Ar. In each case, the two detectors are positioned behind the same source slit. 55V amplifiers are used providing enhanced dynamic range. Full size discrete dynode multipliers are employed, providing maximum stability and lifetime. Over-limit protection is provided, preventing beam entry into the multipliers should the count rate become too high. 06

Collector Option Examples The most popular collector array has been the 1 Faraday, 3 Multiplier (1F3M, offset Faraday) system illustrated below. Other collector arrays have been developed, many in collaboration with our users for specific applications, and these are still available. We welcome enquiries from researchers requiring a special array for a specific application. 07

Noblesse HR Integrated Sample Preparation System Sample Preparation System Nu Instruments offer an all metal sample preparation system for connection to the Noble gas mass spectrometer, either for use by itself, or as an interface between the user s systems and the mass spectrometer inlet. The complete manifold system is manufactured to rigorous UHV standards, and has been designed to have the smallest possible volume, whilst maintaining reasonable gas conductance, so as to ensure the lowest possible blank levels for the analyses. The system includes two calibration gas reservoirs, each fitted with a pipette with auto valves, to enable known quantities of reference gas to be admitted into the mass spectrometer. Automatic valves are provided to the ion pump, and to the furnace section. A dedicated getter is provided adjacent to the furnace, to enable dirty samples to be processed prior to opening the valve to the main manifold section. An additional getter is provided on the manifold near the ion pump. A sample cell is provided, for the user to integrate with their own laser system. 08

Resistance Furnace The furnace consists of a central tantalum crucible, heated by a split tantalum resistive element. This is then surrounded by a series of heat shields and the whole assembly is placed inside a water-cooled chamber, which is pumped independently from the main sample introduction line, with a dedicated high vacuum and backing pump. A water chiller unit is included in the package. A disposable tantalum inner liner is used to contain the dropped samples in the furnace, and hence minimise chemical reactions with the tantalum crucible, thus maximising its lifetime. samples are introduced using a low volume carousel, which permits sequential dispensing of samples. A window enables the samples to be viewed during heating, as well as enabling the temperature to be monitored independently via the use of a (user supplied) optical pyrometer, if required. The temperature of the furnace is monitored using a W/W-Re thermocouple, and controlled using a dedicated controller, interfaced to a PC. A number of different heating profiles may be stored for use in different experiments. 09

Noblesse HR User Friendly and Intuitive Software The Noblesse HR comes with powerful, yet easy to use software that provides the user with all the tools required for analysis of the noble gases. All instrument parameters are controlled from the software. The data analysis package includes curve fitting and extrapolation to time zero, for either amounts versus time or ratios versus time and including rigorous error propagation. data acquisition runs are simple to set up and it is also possible to construct batch runs for a series of samples. The software may also be used to control the Nu Instruments sample preparation system and furnace. Additional digital outputs are available for the control of user-supplied valves. The standard Nu Instruments Calculation Editor (NICE) software provides user-definable data reduction functions. Both raw and calculated data are available for each sample run along with full logging of instrument settings. data can be analysed on or off-line and can be easily exported for further analysis to third party software packages. 10

Selected Publications C J Warren, S C Sherlock, S P Kelley. Interpreting high pressure phengite 40 Ar/ 39 Ar laser probe ages: an example from Saih Hatat, NE Oman. Contributions to Mineralogy and Petrology, DOI 10.1007/s00410-010-0576-1 (2010). C J Warren, S P Kelley, S C Sherlock, C S McDonald. Metamorphic rocks seek meaningful cooling rate: Interpreting 40 Ar/ 39 Ar ages in an exhumed ultra-high pressure terrane. Lithos, DOI: 10.1016/j.lithos.2012.08.011 (2012). C J Campisano, E C Kirk, K E B Townsend and A L Deino. Geochronological and Taxonomic revisions of the Middle Eocene Whistler Squat Quarry (Devil s Graveyard Formation, Texas) and Implications for the Early Uintan in Trans-Pecos Texas. PloS one 9 (7), e101516 (2014). Brad Singer, Brian Jicha, Daniel Condon, Alexandra S Macho, Kenneth A Hoffman, Joseph Dierkhising, Maxwell C Brown, Joshua M Feinberg, Tesfaye Kidane. Precise ages of the Reunion event and Huckleberry Ridge excursion: Episodic Clustering of geomagnetic instabilities and the dynamics of flow within the outer core. Earth and Planetary Science Letters (405), 25-38 (2014). D Kellett and N Joyce. Analytical details of single- and multicollection 40Ar/39Ar measurements for conventional step-heating and total-fusion age calculation using the Nu Noblesse at the Geological Survey of Canada. Geological Survey of Canada, Technical Note 8 (2014) Bastian Baecker. Primordial and other noble gases in micrometeorites. Doctoral Thesis, Ruprecht-Karls-Universität, Heidelberg (2014). Stephanie Flude, Alison M Halton, Simon P Kelley, Sarah P Sherlock and James Schwanetal, Observation of centimetre-scale argon diffusion in alkali feldspars: implications for 40 Ar/ 39 Ar thermochronology. Geological Society, London, Special Publications, 378 pp. 265 275 (2014). Cameron M Mercer, Kelsey E Young, John R Weirich, Kip V Hodges, Bradley L Jolliff, Jo-Anne Wartho, Matthijs C van Soest. Refining lunar impact chronology through high spatial resolution 40 Ar/ 39 Ar dating of impact melts. Sci. Adv. 2015; 1; e1400050 (2015). E N DiMaggio, C J Campisano, J Rowan, G Dupont-Nivet, A L Deino, F Bibi, M E Lewis, A Souron, L Werdelin, K E Reed and J R Arrowsmith. A Rare late Pliocene Fossiliferous Sedimentary Record and the Environmental Context of the early Homo from Afar, Ethiopia. Science Express, 5 March 2015 / 10.1126/science.aaa1415 (2015). E Cossette, D A Schneider, C J Warren, B Grasseman. Lithological, rheological and fluid infiltration control on 40 Ar/ 39 Ar ages in polydeformed rocks from the West Cycladic Detachment System, Greece. Lithosphere 7, 189-205 (2015) J M Saxton, A method for measurement of 36 Ar without H 35 Cl interference. Chemical Geology, 409, 112-117 (2015). 11