Become a Microprobe Power User Part 2: Qualitative & Quantitative Analysis

Similar documents
Creating Empirical Calibrations

SFT3000S Measurement of Sn-Cu Coating

Electron probe microanalysis - Electron microprobe analysis EPMA (EMPA) What s EPMA all about? What can you learn?

Mnova Software for Analyzing Reaction Monitoring NMR Spectra

EDAX Microanalysis Course. Tasks

Polar alignment in 5 steps based on the Sánchez Valente method

Standards-Based Quantification in DTSA-II Part I

Mimir NIR Spectroscopy Data Processing Cookbook V2.0 DPC

How to Make Photometric & Colorimetric Measurements of Light Sources using an Ocean Optics Spectrometer and SpectraSuite Software

Activity P27: Speed of Sound in Air (Sound Sensor)

University of Colorado Denver Anschutz Medical Campus Online Chemical Inventory System User s Manual

Lasentec Product Group

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Physics Department. Experiment 03: Work and Energy

PHY 111L Activity 2 Introduction to Kinematics

Impulse, Momentum, and Energy

NIST DTSA-II ( Son of DTSA ): Step-by-Step

Measuring ph with Smart Cuvettes

Software BioScout-Calibrator June 2013

Exercises for Windows

Quantification of JEOL XPS Spectra from SpecSurf

v Prerequisite Tutorials GSSHA WMS Basics Watershed Delineation using DEMs and 2D Grid Generation Time minutes

Cerno Application Note Extending the Limits of Mass Spectrometry

Miniature Fiber Optic Spectrometry StellarNet Tutorial

Photoluminescence Spectrometer (FLS980)

Atomic Spectra HISTORY AND THEORY

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

Information on the test material EDS-TM002 and the BAM software package EDX Spectrometer Test for determination of the spectrometer performance

ELEC 1908 The Electric Potential (V) March 28, 2013

Standards-Based Quantification in DTSA-II Part II

Jasco V-670 absorption spectrometer

2. To measure the emission lines in the hydrogen, helium and possibly other elemental spectra, and compare these to know values.

Lasentec Product Group

Force vs time. IMPULSE AND MOMENTUM Pre Lab Exercise: Turn in with your lab report

Automatic Watershed Delineation using ArcSWAT/Arc GIS

SkyGlobe Planetarium

Graphical User Interfaces for Emittance and Correlation Plot. Henrik Loos

Technical notes: using the optical/ellipsometric film thickness measurement setup.

MassHunter Software Overview

HOW TO ANALYZE SYNCHROTRON DATA

Experiment: Oscillations of a Mass on a Spring

Application Note. U. Heat of Formation of Ethyl Alcohol and Dimethyl Ether. Introduction

Joint ICTP/IAEA Workshop on Advanced Simulation and Modelling for Ion Beam Analysis

MERGING (MERGE / MOSAIC) GEOSPATIAL DATA

Tutorial 2: Analysis of DIA data in Skyline

The OptiSage module. Use the OptiSage module for the assessment of Gibbs energy data. Table of contents

Faults Loading and Display in CE8R2 and R3. David Worsick, Calgary February 25, 2009

You w i ll f ol l ow these st eps : Before opening files, the S c e n e panel is active.

Newton's 2 nd Law. . Your end results should only be interms of m

Treatment of Data. Methods of determining analytical error -Counting statistics -Reproducibility of reference materials -Homogeneity of sample

Background The power radiated by a black body of temperature T, is given by the Stefan-Boltzmann Law

ON SITE SYSTEMS Chemical Safety Assistant

Physics 476LW Advanced Physics Laboratory Atomic Spectroscopy

Connect the Vernier spectrometer to your lap top computer and power the spectrometer if necessary. Start LoggerPro on your computer.

S8 TIGER Series 2 for ASTM D 6443

Chem 1 Kinetics. Objectives. Concepts

TIMEZERO PROFESIONAL V3.2

Technical Procedure for Glass Refractive Index Measurement System 3 (GRIM 3)

1. Prepare the MALDI sample plate by spotting an angiotensin standard and the test sample(s).

Physical Chemistry II Laboratory

IncuCyte ZOOM NeuroTrack Fluorescent Processing

Kinetics of Crystal Violet Bleaching

85. Geo Processing Mineral Liberation Data

Agilent MassHunter Quantitative Data Analysis

Computer simulation of radioactive decay

HMQC HSQC and HMBC. Gradient HMQC, HMBC on the Bruker400 and 500

Login -the operator screen should be in view when you first sit down at the spectrometer console:

X-RAY SPECTRA. Theory:

Sample Alignment (2D detector) Part

Figure 2.1 The Inclined Plane

General Chemistry Lab Molecular Modeling

RC Circuits. Equipment: Capstone with 850 interface, RLC circuit board, 2 voltage sensors (no alligator clips), 3 leads V C = 1

Measuring the time constant for an RC-Circuit

UV-Vis optical fiber assisted spectroscopy in thin films and solutions

Lab 1: Dynamic Simulation Using Simulink and Matlab

Introduc)on to IQmol: Part I.!!! Shirin Faraji, Ilya Kaliman, and Anna Krylov

Application Note. Capillary Zone Electrophoresis

85. Geo Processing Mineral Liberation Data

Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI

Lab 1 Uniform Motion - Graphing and Analyzing Motion

Chem 253. Tutorial for Materials Studio

University of Minnesota Nano Center Standard Operating Procedure

Work and Energy. This sum can be determined graphically as the area under the plot of force vs. distance. 1

Relativistic Electrons

Spin transport in Magnetic Tunnel Junctions

DIFFUSION THROUGH MEMBRANES STANDARDS B C.4 INTRODUCTION

LAB 2 - ONE DIMENSIONAL MOTION

Gravity: How fast do objects fall? Student Advanced Version

Experiment 4 Radiation in the Visible Spectrum

Exercise 2-2. Titration of a Strong Acid EXERCISE OBJECTIVES

University of TN Chattanooga Physics 1040L 8/18/2012 PHYSICS 1040L LAB LAB 4: R.C. TIME CONSTANT LAB

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

Title: ASML PAS 5500 Job Creation Semiconductor & Microsystems Fabrication Laboratory Revision: D Rev Date: 09/20/2012

Experiment 10. Zeeman Effect. Introduction. Zeeman Effect Physics 244

TECDIS and TELchart ECS Weather Overlay Guide

Zeeman Effect Physics 481

Agilent MassHunter Quantitative Data Analysis

Faults Loading and Display in HRS-9. David Worsick, Calgary September 12, 2012

Athena Visual Software, Inc. 1

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Physics Department

Magnetic Fields. Experiment 1. Magnetic Field of a Straight Current-Carrying Conductor

Transcription:

Become a Microprobe Power User Part 2: Qualitative & Quantitative Analysis Mike Spilde Spring IOM Seminar February 5, 2008

Qualitative Analysis Why use qualitative scans? Elemental ID (especially trace element ID) Locating Background Positions Identifying peak overlaps Setup a Qualitative Scan

ID of Trace Elements: Qualitative Jarosite Scan <0.2 wt% As <1 wt% P Neither the As nor the P will be detected using the EDS

Overlaping Peaks Question: Is sulfur present? Parasitic overlap between Pb M & S K is resolved in WDS Qualitative Scan

Determination of Background Positions Question: Will the 2nd order Fe lines interfere with the background positions for K? Hint: right-click here to tear off Spectral Display menu Select Zooming to zoom in around K & Fe peaks in Channel 2. Then select Quant. Background

Determination of Background Positions Low Bkg Peak Hi Bkg Upper K background at the default 5 mm offset is too close to 2nd order FeK Click on right background line and drag to the right. Then Exec to write to file.

Why it is Important to Check Backgrounds with a Qualitative Scan Low Bkg 2nd order Ca K 80 cts 20 cts Low background at 5 mm on diopside standard produces 600 cts (10 sec count) background differential. Background measured on enstatite sample yields 200 cts less. Sample has higher counts relative to standard. Result? High totals on sample.

Stored Qualitative Scans Qual_Database: everyone has a copy WDS_Scans: Change Working Directory to /export/home/spilde

Change Working Directory to get to WDS_Scans Select File and click on Change Working Directory Select /export/home/spilde (be sure Qualitative Analysis is closed before switching) Be sure to return to your working directory when finished

How to Setup a Qualitative Scan Set # of spectra, Channel #, and Crystal Set for range (e.g. length of spectrometer) or click on Elem to set specific elements

QUANTATIVE ANALYSIS The reason most of us use the probe

Quantitative Analysis Setup Setup Quantitative Analysis file first Then setup Standard Analysis file, if necessary Calibrate Verify that peak position is appropriate Verify that background counts are reasonable Verify that Std Variance is low Check analysis file Check the places where you can get tripped up

Quantitative Analysis Setup Work sequentially through the Measurement setup menu Select Correction Method Enter Element Conditions Enter EOS Conditions After calibration, set Standard Conditions If necessary, set Additional Functions Save with Conditions Store Then set Stage Conditions

Quantitative Analysis Setup Correction Method Set Material type according to what you are analyzing: Select Oxide for most silicate analysis conditions Select Metal for oxygen analysis, metals, sulfides, etc. Use ZAF for most conditions PRZ tends to give better results for light element analysis

Quantitative Analysis Setup Element Selection Click buttons to select To delete, click or drag across elements to select, then Clear

Quantitative Analysis Setup Element Conditions Element Setup Global conditions file Conditions specific to this file Global file is available to Quant and Standard Analysis, Map, Line, etc. You can have multiple setups on the same spectrometer for different ent conditions

Quantitative Analysis Setup Element Setup After element entry, click on Peak overlap button Always check Peak Overlap window. Red highlighted entries are critical.

Quantitative Analysis Setup Differential vs. Integral mode Higher order Ca peaks interfere with P peak Int mode Diff mode Diff mode w/ 4 volt window Diff mode filters out interference

Quantitative Analysis Setup Calculated elements setup Hydrated mineral setup Ex: jarosite KFe 3 (SO 4 ) 2 (OH) 6 Carbonate mineral setup CO2 is calculated by atomic ratio to the 3 anions of oxygen.

Quantitative Analysis Setup EOS (Electron Optics) setup For constant beam current, click check box and then enter value in Auto window Expand beam for unstable minerals Make sure beam scan is off!!! Beam stabilizer is set here if desired (CL or CL & Tilt)

Quantitative Analysis Setup Additional Function setup For overnight runs involving 100 s of analyses, run peak search every 100 or so analyses For fairly constant compositions, background measurements are not needed at every point Set overlap correction for V-Ti, V Cr- Mn,, Mo-S, etc. Software measures the contribution to Mo from S and corrects for the overlap

Quantitative Analysis Setup Stage Conditions Focus on point and hit Read & Apply to record point Use down arrow to move to new point Small star indicates current position X Use Move button to move to recorded position Larger red X indicates where saved point is set (where stage will move to)

Select Line Set to set line traverse Quantitative Analysis Setup Stage Conditions: Line Traverse Move to starting point and select Read Move to ending point and select Read Set points in between start and stop by number of points or distance between points

Quantitative Analysis Setup Setup Quantitative Analysis file first Then setup Standard Analysis file, if necessary Calibrate Verify that peak position is appropriate Verify that background counts are reasonable Verify that Std Variance is low Check analysis file Check the places where you can get tripped up

Standard Analysis Setup Standard Composition Make absolutely sure that you are entering the right values: If Standard Type is set for oxide, enter oxide values in composition window. If Type is set for metal, enter elemental values in composition window, including oxygen.

Standard Analysis Setup Element Setup Do these agree between standard & analysis setups? Correct spectrometer? Right crystal? PHA conditions the same? Make sure that your calibration setup is correct: Calibrate each element on the same spectrometer and crystal as the t analysis file The PHA conditions must be the same for calibration and analysis Other conditions may vary between standard and analysis setup files: Counting times can be different Background positions can be different

Quantitative Analysis Setup Setup Quantitative Analysis file first Then setup Standard Analysis file, if necessary Calibrate Verify that peak position is appropriate Verify that background counts are reasonable Verify that Std Variance is low Check analysis file Check the places where you can get tripped up

Standard Analysis Calibration Use Peak Search Monitor (Analysis menu) to inspect peak positions during calibration Open the Peak Search Monitor ONLY before you start calibration If the resulting peak is not on the peak centroid,, redo the search

Standard Analysis After Calibration Look at your calibration (possibly save for later reference) Check accumulated values. Are there significant deviations? Check Standard Variance (S.V.). Ideally 0.5% or less. Check backgrounds. If one is significantly higher (2X), double check c your background positions for interfering peaks, such as K. K Compare with previous calibration. Did peak position or count rate change?

Standard Analysis After Calibration If S.V. is too high, select Check Data to remove bad data Click Acm button Then click on standard accumulations Unselect values that deviate significantly from the average, then Save

Quantitative Analysis Setup Setup Quantitative Analysis file first Then setup Standard Analysis file, if necessary Calibrate Verify that peak position is appropriate Verify that background counts are reasonable Verify that Std Variance is low Check analysis file Watch the places where you can get tripped up

After Calibration Places where you are going to get tripped up Open Standard Condition window and make sure that the correct standards are selected. If not, open the Standard Data for that element and select the right standard. If the standard that you just calibrated does not appear in the list, make sure STD Group All is selected. If you still cannot see the standard that you calibrated, you have probably calibrated the element on the wrong g spectrometer or at the wrong conditions (20 kv when you meant to use 15 kv).

After Calibration Places where you are going to get tripped up Open Element Conditions window and verify that all Peak Positions have been updated. Old peak position New peak position If peak has not updated, open global element window for that element and click OK