Development and Validation of Flat-Plate Collector Testing Procedures

Similar documents
Development and Validation of Flat-Plate Collector Testing Procedures

Development and Validation of Flat-Plate Collector Testing Procedures

Simplified Collector Performance Model

OPTIMIZATION of the GEOMETRY & MATERIAL of SOLAR WATER HEATERS.

Performance Assessment of PV/T Air Collector by Using CFD

THERMAL PERFORMANCE OPTIMIZATION OF A FLAT PLATE SOLAR WATER HEATER COLLECTOR USING MATLAB

Theoretical Analysis of Overall Heat Loss Coefficient in a Flat Plate Solar Collector with an In-Built Energy Storage Using a Phase Change Material

Solar Flat Plate Thermal Collector

Contents... 1 Intro... 1 Giving guarantees... 2

ANSI/AHRI Standard (Formerly ARI Standard ) 2006 Standard for Performance Rating of Desuperheater/Water Heaters

Chapter 5 MATHEMATICAL MODELING OF THE EVACATED SOLAR COLLECTOR. 5.1 Thermal Model of Solar Collector System

CFD ANALYSIS OF TRIANGULAR ABSORBER TUBE OF A SOLAR FLAT PLATE COLLECTOR

Enerpool v Swimming Pool Simulation Simulation File: C:\ENERPOOL\SANDA.EPL Run on: Fri Feb 07 19:27:

Experimental analysis of thermal performance of flat plate and evacuated tube solar collectors in stationary standard and daily conditions

N. Lemcoff 1 and S.Wyatt 2. Rensselaer Polytechnic Institute Hartford. Alstom Power

Thermal Analysis of a Flat-Plate Solar Collectors in Parallel and Series Connections Huseyin Gunerhan

Vertical Mantle Heat Exchangers for Solar Water Heaters

Experimental Investigation of the Effect of Forced Convection on Solar Thermal Collector Efficiency

THE EFFECTS OF CALORIMETER TILT ON THE INWARD-FLOWING FRACTION OF ABSORBED SOLAR RADIATION IN A VENETIAN BLIND

UNIT FOUR SOLAR COLLECTORS

A. Solar Walls. B. Prototype I

Construction and performance analysis of a three dimensional compound parabolic concentrator for a spherical absorber

Test Procedures for Sorption Chillers Based on the Working Mode

Advanced Thermography Investigations

EFFECT OF OPERATING PARAMETERS ON THE PERFORMANCE OF THE HYBRID SOLAR PVT COLLECTOR UNDER DIFFERENT WEATHER CONDITION

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 6, Issue 11, May 2017

1 / 17. TÜV Rheinland (Shanghai) Co., Ltd Solar/ Fuelcell Technologies. Test Report

Collector test according to EN ,2:2002

Optimization of the Air Gap Spacing In a Solar Water Heater with Double Glass Cover

Tick the box next to those resources for which the Sun is also the source of energy.

BACK TO BASICS: PIPE INSULATION

SOME ASPECTS ON PARABOLIC TROUGH FIELD OPERATION WITH OIL AS A HEAT TRANSFER FLUID

Report of Performance Test according to EN for a Glazed Solar Collector

Exam questions: HEAT. 2. [2003 OL][2004 OL][2005 OL][2006 OL][2007 OL][2008 OL][2009] Name two methods by which heat can be transferred.

The Comparison between the Effects of Using Two Plane Mirrors Concentrator and that without Mirror on the Flat- Plate Collector

Performance Rating of Thermal Storage Equipment Used for Cooling

A Typical Meteorological Year for Energy Simulations in Hamilton, New Zealand

ISO/TC 180/SC. Date: ISO/xxxx yyyy. Secretariat: SA. Solar energy Collector fields Check of performance. Énergie solaire xxx yyy

TEST OF MEASURED SOLAR HEAT GAIN VARIATION WITH RESPECT TO TEST SPECIMEN TILT

ANALYSIS OF FLAT PLATE PHOTOVOLTAIC-THERMAL (PVT) MODELS

STUDY OF FLAT PLATE COLLECTOR SOLAR WATER HEATER

AR/IA 241 LN 231 Lecture 4: Fundamental of Energy

Ordinary Level Physics Long Questions: TEMPERATURE AND HEAT

Report of Performance Test according to EN for a Glazed Solar Collector

Experimental investigation of the performance of a Parabolic Trough Collector (PTC) installed in Cyprus

STUDY ON THE THERMAL PERFORMANCE AND AIR DISTRIBUTION OF A DISPLACEMENT VENTILATION SYSTEM FOR LARGE SPACE APPLICATION

DETAILED MODELING OF SOLAR FLAT-PLATE COLLECTORS WITH DESIGN TOOL KOLEKTOR 2.2

Effect of Selective Coatings on Solar Absorber for Parabolic Dish Collector

INVESTIGATION OF THE PERFORMANCE OF COOLING PANELS: CEILING AND FLOOR PANElS.

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

Performance Investigation of Cavity Absorber for Parabolic Dish Solar Concentrator

Use Coldplate to model a cold plate and heat exchanger circuit

Handout 10: Heat and heat transfer. Heat capacity

Validation of IDA Indoor Climate and Energy

Chapter 1 INTRODUCTION AND BASIC CONCEPTS

Chapter Seven. Solar Energy

TÜV Rheinland PTL, LLC 2210 South Roosevelt Street Tempe, AZ Test Report

Institut national des sciences appliquées de Strasbourg GENIE CLIMATIQUE ET ENERGETIQUE APPENDICES

INDUSTRIAL INSULATION for Systems Operating Above Ambient Temperature

4.1 Derivation and Boundary Conditions for Non-Nipped Interfaces

Chapter 11: Heat Exchangers. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Coolant. Circuits Chip

Radiant Heating Panel Thermal Analysis. Prepared by Tim Fleury Harvard Thermal, Inc. October 7, 2003

NUMERICAL SIMULATION OF THE AIR FLOW AROUND THE ARRAYS OF SOLAR COLLECTORS

DESIGN AND COST ANALYSIS OF HEAT TRANSFER EQUIPMENTS

HEAT TRANSFER CAPABILITY OF A THERMOSYPHON HEAT TRANSPORT DEVICE WITH EXPERIMENTAL AND CFD STUDIES

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

ME 476 Solar Energy UNIT THREE SOLAR RADIATION

Overall Heat Transfer Coefficient

The influence of solar radiation on the distribution of temperatures in historic masonry

An Experimental Study of Flat Radial Fresnel Len Solar Collector for High Temperature Thermal System

Solar radiation and thermal performance of solar collectors for Denmark

The Electrodynamics of a Pair of PV Modules with Connected Building Resistance

1/54 Circulation pump, safety valve, expansion vessel

Thermal Analysis of Solar Collectors

TOLERANCES AND UNCERTAINTIES IN PERFORMANCE DATA OF REFRIGERANT COMPRESSORS JANUARY 2017

PROBLEM Node 5: ( ) ( ) ( ) ( )

NFRC SOLAR HEAT GAIN COEFFICIENT TEST REPORT. Rendered to: CLEAR FOCUS IMAGING

Faculty of Technology and Science Department of Physics and Electrical Engineering. Helena Johansson. Nocturnal cooling

The Heat Budget for Mt. Hope Bay

Chapter 1: 20, 23, 35, 41, 68, 71, 76, 77, 80, 85, 90, 101, 103 and 104.

Flow and Temperature Analysis inside Flat Plate Air Heating Solar Collectors

Making Decisions with Insulation

Solar Matters II Teacher Page

EE Properties of Sunlight. Y. Baghzouz Professor of Electrical Engineering

PERFORMANCE EVALUATION OF REFLECTIVE COATINGS ON ROOFTOP UNITS

CCMR Educational Programs

NEGST. New generation of solar thermal systems. Advanced applications ENEA. Comparison of solar cooling technologies. Vincenzo Sabatelli

Model 3024 Albedometer. User s Manual 1165 NATIONAL DRIVE SACRAMENTO, CALIFORNIA WWW. ALLWEATHERINC. COM

EXPERIMENTAL STUDY ON A CASCADED PCM STORAGE RECEIVER FOR PARABOLIC DISH COLLECTOR

Effect of Periodic Variation of Sol-air Temperature on the Performance of Integrated Solar Collector Storage System

Estimation of insolation of flat plate solar collectors in selected cities in Nigeria

Energy flows and modelling approaches

Standard Practices for Air Speed Calibration Testing

Standard Test Method for Measuring the Steady-State Thermal Transmittance of Fenestration Systems Using Hot Box Methods 1

IN-PLANE THERMAL CONDUCTIVITY OF FLAT PLATES UTILIZING THE FOURIER HEAT CONDUCTION LAW

CFD ANALYSIS FOR INTEGRATED COLLECTOR STORAGE SOLAR WATER HEATERS (ICSSWH) BASED ON CUBOID TYPE GEOMETRIES

Optimizing the Photovoltaic Solar Energy Capture on Sunny and Cloudy Days Using a Solar Tracking System

Greenhouse Steady State Energy Balance Model

HFM 100 Series. Thermal Conductivity Meter for measurement of insulation and construction materials.

Transcription:

Development and Validation of Flat-Plate Collector Testing Procedures Report for February, 2007 Focus on Energy (FOE) supports solar thermal systems that displace conventional fuels by offering cash-back rebates that provide an incentive for residents to invest in this renewable energy technology. To be eligible for rebates, FOE requires solar collectors to be certified by the Solar Rating and Certification Corporation (SRCC). The certification program involves testing of the solar collectors in accordance with ASHRAE Standard 93-2003 1. Currently, these tests are only provided in Florida (outdoors) by the Florida Solar Energy Center (FSEC). Wisconsin s flat plate collector testing program will be done at Madison Area Technical College (MATC). The UW-Solar Energy Laboratory is assisting MATC personnel in establishing a suitable implementation of the ASHRAE test method. The UW further intends to identify alternative test methods that can be done indoors or under conditions that are more suitable to Wisconsin weather, but still provide the information required by the ASHRAE 93-2003 test. What follows is the fifth report of this activity. This report is not a final report. The content of this report is therefore continuously reviewed and corrected if necessary. Corrected versions of the actual and preceding reports can be found on the UW Solar Energy Lab webpage: http://sel.me.wisc.edu/research/coltest.html 1 ANSI/ASHRAE Standard 93-2003, Methods of Testing to Determine the Thermal Performance of Solar collectors. ISSN 1041-2336, ASHRAE, Inc., 2003, 1791 Tullie Circle, Ne, Atlanta, GA30329

Table of contents 1. Data analysis incidence angle modifier test... 3 2. Closed loop design... 5 2.1. Closed loop... 5 2.2. Heater... 5 2.2.1. Required inlet temperatures... 5 2.2.2. Heater power calculations... 5 2.2.3. Test system heat capacity... 6 2.2.4. Results... 7 2.3. Air source cooler... 7 3. Comparison of solar thermal collector test standards... 10 3.1. Unglazed collectors... 10 3.1.1. Purpose and scope of compared test standards... 10 3.1.2. Test conditions comparison... 11 3.1.3. Tables... 15 Solar Energy Laboratory Page 2 3/2/2007

1. Data analysis incidence angle modifier test An incidence angle modifier test was performed on December 9, 2006. The desired incidence angles are achieved by adjusting the azimuth angle of the collector. Table 1 summarizes the sequences of testing conditions and the corresponding measured efficiencies. The efficiency as a function of incidence angle is plotted in Figure 1. Figure 2 shows the incidence angle modifier with respect to the incidence angle and Figure 3 shows the incidence angle modifier as a linear function of the term [ -1 + 1 / cos(incidence angle) ]. The incidence angle modifier coefficient, b 0, is estimated to be 0.179 based on the measurements. The test results are not in accordance with ASHRAE 93-2003, as the test conditions were not maintained within the allowed range over the required time period of 20 minutes. The test should be repeated if possible. Test No. Incidence Angle [degree] Table 1 Test setup incidence angle modifier test Start Time [local time] End Time [local time] Collector azimuth [degree west] Efficiency 1 0 13:10:00 13:24:30 21.7 0.650 2 30 13:25:00 13:36:30 51.9 0.649 3 45 13:40:00 13:52:00 75.2 0.631 4 60 13:55:00 14:10:00 97.1 0.531 0.7 0.6 0.5 Efficiency 0.4 0.3 0.2 0.1 0 0 20 40 60 80 Incidence Angle [deg] Figure 1 Incidence angle modifier test: efficiency vs. incidence angle Solar Energy Laboratory Page 3 3/2/2007

1.20 1.00 Incident Angle Modifier 0.80 0.60 0.40 0.20 0.00 0 20 40 60 80 Incidence Angle [deg] Figure 2 Incidence angle modifier test: incidence angle modifier vs. incidence angle 1.20 1.00 Incident Angle Modifier 0.80 0.60 0.40 0.20 y = -0.1792x + 1 0.00 0 0.2 0.4 0.6 0.8 1 1.2-1 + 1 / cos(incidence Angle) Figure 3 Incidence angle modifier test: incidence angle modifier as linear function Solar Energy Laboratory Page 4 3/2/2007

2. Closed loop design 2.1. Closed loop A new test mount will be built at MATC. The major changes compared to the existing mount are that the heat transfer fluid will circulate in a closed loop, which allows use of heat transfer fluid alternatives that differ from water, e.g. ethylene glycol or propylene glycol. The test mount will be capable of tracking the sun, which allows maintaining normal incidence for tests throughout the day. Figure 4 shows a block diagram of the planned test loop, designed by Thomas Kaminski. 2.2. Heater Figure 4 MATC solar collector test stand (closed loop), design by Thomas Kaminski 2.2.1. Required inlet temperatures The collector tests must be conducted with four different inlet temperature levels. The inlet temperature levels are set to specified values above the ambient temperature at the test site. There is a concern with the time required to bring the fluid inventory in the test loop up to its operating temperature. Assuming that the heat losses of the test loop are lower than the rate of energy gain of the collector, the collector itself will be able to increase the temperature of the heat transfer fluid to the desired temperature levels. However, the heating power of the collector may be low compared to the heat capacity of the test loop resulting in delays at startup. Consequently electric heaters are integrated in the test loop, not only to control the collector inlet temperature precisely, but also to decrease the loop s transient time. 2.2.2. Heater power calculations The maximum required heater power is defined by the following equation: Solar Energy Laboratory Page 5 3/2/2007

P ( mc i i) ΔTmax i max = Δtmax where m i and c i are the mass and the specific heat of component i of the test system. ΔT max is the maximum required temperature increase during testing and Δt max is the maximum acceptable time period for the heat up process. P coll represents the heat power provided by the collector and P loss represents the heat losses of the test system to the ambient. P coll + P loss (1.1) The maximum heating power is dictated by the largest increase in temperature, which is ΔT max 80 C (144 F) above ambient temperature. In order to size the heater, a time period, Δt max, of 20 minutes is assumed and the heat losses are neglected (P loss = 0). In the worst case (test of solar collector with small area under low irradiance) the heat power contribution of the collector is negligible, so the P coll is set to zero. The heat capacities will be determined in the next section. 2.2.3. Test system heat capacity Δ T = C (1.2) max 80 Δ t max = 20 min (1.3) P = 0 (1.4) coll P = 0 (1.5) loss The heat capacity of the test system is determined by the solar collector and the components of the test loop on the one side and the heat transfer fluid on the other side. The heat capacity of the collector has been determined for the maximum collector area that can be tested with the planned test mount based on typical values listed by SRCC 2. At this time, the components of the test loop are not known, so their heat capacities can not be determined. They are included in the calculations by overestimating the heat capacity of the collector. The heat capacity of the heat transfer fluid is the product of the volume, the density and the specific heat of the heat transfer fluid. Density and specific heat are known for water and a glycol water solution. The heat capacity of water will be used for the calculations as it is higher compared to the heat capacity of the solution and therefore results in a higher heater power. The volume of the heat transfer fluid depends on the fluid capacity of the collector and the fluid capacity of the test loop (piping and other components). The fluid capacity of the collector has been determined based on typical values listed by SRCC. The fluid capacity of the test loop is not known at present, so the results will be presented as a function of the fluid capacity of the test loop. 2 Solar Rating and Certification Corporation (SRCC), Directory of SRCC Certified Solar Collector Ratings, http://www.solar-rating.org/summary/dirsum_20070201.pdf Solar Energy Laboratory Page 6 3/2/2007

2.2.4. Results Based on the parameters set before, the required heater power depending on the fluid capacity of the test loop has been calculated and is presented in Table 2 and Table 3. Table 2 Required heater power for 80 C temperature increase within 20 minutes (SI units) Fluid capacity of collector [liters] Fluid capacity of other test loop components [liters] Heater Power [kw] 6 5 3.3 6 10 4.9 6 20 8.0 6 30 11.1 6 40 14.2 6 50 17.3 6 100 32.8 Table 3 Required heater power for 80 C temperature increase within 20 minutes (English units) Fluid capacity of collector [gal] Fluid capacity of other test loop components [gal] Heater Power [Btu/hr] 6 1.4 11,200 6 2.7 16,500 6 5.3 27,100 6 8.0 37,700 6 10.6 48,300 6 13.3 58,900 6 26.5 111,900 2.3. Air source cooler An air (ambient) to liquid heat exchanger in will be used to cool the heat transfer fluid (air source cooler in Figure 4). In cases where the air source cooler cannot provide enough cooling power, it will be supported by a chiller (Figure 4). It is desirable to decrease the temperature of the heat transfer fluid from its temperature at the collector outlet to a temperature of 2.8 C below the required collector inlet temperature (Eq. (1.8)) in order to allow a precise adjustment of the collector inlet temperature to the required value by the heaters. To select the appropriate heat exchanger and fan, the capacitance Solar Energy Laboratory Page 7 3/2/2007

rate of the heat transfer fluid, the required temperature decrease of the heat transfer fluid and the temperature of the ambient air must be provided. Air to glycol/water HX T fluid, in ChillerChill T fluid, out Solar collector T collector, in Heaters Figure 5 MATC test loop Δ T = T T, collector fluid, in collector in (1.6) Δ T = T T (1.7) fluid fluid, out fluid, in Δ T =Δ T + 2.8 C fluid collector (1.8) The increase in temperature of the heat transfer fluid by the solar collector depends on the heating power of the collector and the capacitance rate of the heat transfer fluid. The air HX must provide the most cooling power when the collector produces the most heating power. This is the case at high irradiance and high collector efficiency (1,200 W/m 2 and 0.75 used for calculations). The new test mount is designed for panel dimensions up to 1.22 m (4 ft) width and 2.44 m (8 ft) length. So the maximum collector area that can be tested is 3.9 m 2 (32 ft 2 ). At these conditions the collector provides a heating power of 3.8 kw (13,000 Btu/hr). The maximum collector area determines the maximum mass flow rate through the collector during the tests, as ASHRAE Standard 93-2003 recommends 0.02 kg/(s-m 2 collector area). Two heat transfer fluids will be used for testing, pure water and a propylene glycol water mixture with a concentration of 50% by volume. The capacitance rates for these fluids have been calculated. Table 4 and Table 5 show the extreme conditions for the air heat exchanger. The first condition represents a test with the lowest expected ambient temperature and the lowest expected collector inlet temperature; these conditions provide the minimum air inlet temperature expected for the heat exchanger. The second condition represents a test with maximum expected ambient temperature and maximum collector inlet temperature which gives the maximum inlet temperature of the air HX. The temperature, T fluid,in, represents Solar Energy Laboratory Page 8 3/2/2007

the heat transfer fluid temperature at the air HX inlet, C fluid is the capacitance rate of the heat transfer fluid, and ΔT fluid is the required temperature decrease. For the minimum ambient temperature case, the ΔT fluid cannot be provided by the ambient air-to-liquid heat exchanger alone, as the inlet temperature of the collector is set equal to ambient temperature. This means that temperatures below the air inlet temperature are required. For both cases (maximum and minimum ambient temperature), the size or the cost of the heat exchanger might be the limitation for the cooling power of the air HX. The portion of the required temperature decrease that cannot be provided by the air HX will be provided by the air conditioner. T fluid,out Air to glycol/water heat exchanger T air,in T fluid,in C fluid Figure 6 Air to glycol/water heat exchanger Table 4 Conditions for air to glycol/water heat exchanger, SI units Condition Fluid T air,in [C] T fluid,in [C] Lowest ambient temperature Highest ambient temperature 50% Glycol/Water C fluid [kj/s-k] ΔT fluid [C] -23.4-8.272 0.251 17.93 Water 3 14.63 0.327 14.43 50% Glycol/Water 37.8 130.4 0.301 15.44 Water 37.8 129.3 0.332 14.26 Table 5 Conditions for air to glycol/water heat exchanger, English units Condition Fluid T air,in [F] T fluid,in [F] Lowest ambient temperature Highest ambient temperature 50% Glycol/Water C fluid [Btu/hr-F] ΔT fluid [F] -10.1 17.1 476.5 32.3 Water 37.4 58.3 619.8 26.0 50% Glycol/Water 100.0 266.8 570.1 27.8 Water 100.0 264.7 628.7 25.7 Solar Energy Laboratory Page 9 3/2/2007

3. Comparison of solar thermal collector test standards 3.1. Unglazed collectors 3.1.1. Purpose and scope of compared test standards The purpose of all compared test standards is to provide test methods for thermal solar collectors, including methods for the determination of the thermal efficiency. The following table summarizes the methods in current use for determining the thermal efficiency of a collector as well as the types of collectors and associated heat transfer fluids covered by the various standards. Test Standard ASHRAE 96 ISO 9806-3 EN 12975-2: Chapter 6.1 (steady state) EN 12975-2: Chapter 6.3 (dynamic) Scope Test methods: Steady state Outdoor and indoor Collectors: Flat plate Unglazed Heat transfer fluids: Liquid Test methods: Steady state Outdoor and indoor Collectors: Unglazed Heat transfer fluids: Liquid Exceptions: Collectors with integrated thermal storage unit Collectors with phase change of heat transfer fluid Test methods: Steady state Outdoor and indoor Collectors: Unglazed Heat transfer fluids: Liquid Exceptions: Collectors with integrated thermal storage unit Tracking concentrating Test methods: Dynamic Outdoor Collectors: Glazed and unglazed Nonconcentrating and concentrating 3 Heat transfer fluids: Liquid Exceptions: Collectors with integrated thermal storage unit 3 The test method must be adjusted for the test of concentrating collectors. Solar Energy Laboratory Page 10 3/2/2007

3.1.2. Test conditions comparison All standards prescribe test conditions for performing thermal efficiency tests. These test conditions determine how restrictive the test method is with respect to the test apparatus and the climatic conditions at the test site. The following table shows a comparison of the test conditions for the three test standards considered. All values are mandatory if not specifically noted otherwise. Test conditions ASHRAE 96 ISO 9806-3 Test procedure Number of data points 4 16 4 for each inlet temperature Symmetric pairs for fixed mount outdoor. 32 4 of each type (See Table 6.) Symmetric pairs for fixed mount outdoor. Length predata period 5 15 min outdoor 4*C/(mCp) 6 but minimum 15 min EN 12975-2: Chapter 6.1 (steady state) 18 2 of each type (See Table 7.) Symmetric pairs only if conditions allow. 4 collector time constants but minimum 15 min EN 12975-2: Chapter 6.3 (dynamic) Not applicable, as no single data points but continuous measurements throughout the day are taken. Not applicable. Comments Symmetric pairs mean that two measurements for the same collector inlet temperature are taken at times symmetric to solar noon. One efficiency value is measured before and one after solar noon. 4 A data point is the pair of two values: the temperature difference irradiance ratio and the determined efficiency value for a data period. Based on all determined data points the efficiency curve of the collector is derived. 5 The predata period is defined as the time period ahead to the data period. The measurements of the predata period are not used for the calculation of the efficiency, but to make sure that steady state conditions are achieved. The predata period is also called preconditioning period. 6 C is the heat capacity of the collector. mcp is the heat capacitance flow rate of the heat transfer fluid.

Test conditions ASHRAE 96 ISO 9806-3 Length of data period 7 5 min outdoor 15 min 4 time constants Minimum amount of required test days Fixed mount: 3 to 4 clear days Altazimuth mount: 2 clear days Fixed mount: 6 to 8 clear days Altazimuth mount: 4 clear days EN 12975-2: EN 12975-2: Chapter 6.1 (steady Chapter 6.3 state) (dynamic) but minimum 15 min Fixed mount: 4 clear days Altazimuth mount: 2 clear days Not applicable. 4 to 5 days recommended (no nights) (see Table 8) Comments Set points for controlled variables Inlet temperature distribution 4 inlet temperatures 1 with X within -0.02 to -0.15 C/(W/m2) 3 with X within 0.01 to 0.03 C/(W/m2) See Table 6. See Table 7. 3 inlet temperatures See Table 8 and Table 9. Hottest temperature depends on collector application. X = ( collector inlet temperature - ambient temperature) / Solar irradiance upon collector in C/(W/m 2 ) Mass flow rate 0.7 kg/s-m2 or manufacturer recommendation 0.4 kg/s-m2 or manufacturer recommendation 0.4 kg/s-m2 or manufacturer recommendation 0.02 kg/s-m2 or manufacturer recommendation 7 The data period is defined as the time period of which measurements are used to calculate the thermal efficiency. Solar Energy Laboratory Page 12 3/2/2007

Test conditions ASHRAE 96 ISO 9806-3 Allowed range of uncontrolled variables (absolute limits) Total solar irradiance on collector plane Incidence angle (angle between beam radiation and collector normal) Wind speed Ambient temperature Ambient temperature range between all data points EN 12975-2: EN 12975-2: Chapter 6.1 (steady Chapter 6.3 state) (dynamic) Minimum 630 W/m2 Minimum 650 W/m2 Minimum 650 W/m2 Minimum 300 W/m2 Maximum 30 deg Maximum 30 deg Maximum 30 deg No requirement No minimum defined. Maximum 1.3 m/s Min 15 C Max 38 C Maximum 10 K Minimum 1.5 m/s Maximum 4.0 m/s Only variation limits defined (see Table 6). No requirement defined. Minimum 0.0 m/s Maximum 3.5 m/s Minimum dew point temperature. No requirement defined. Minimum 0 m/s Maximum 3.5 m/s Minimum dew point temperature No requirement defined. Wind speed Average max 1.3 m/s See Table 6. See Table 7. Average between 1 and 4 m/s Comments This requirement ASHRAE 96 uses surrounding air speed independent of direction while EN 12975-2 uses air speed parallel to collector. ISO 9806-3 does not specify which speed to use. Solar Energy Laboratory Page 13 3/2/2007

Test conditions ASHRAE 96 ISO 9806-3 Allowed variation of controlled and uncontrolled variables (steady state conditions) EN 12975-2: Chapter 6.1 (steady state) Inlet temperature Not defined. ± 0.1 K ± 0.1 K ± 1 K EN 12975-2: Chapter 6.3 (dynamic) Inlet flow rate Not defined. ± 1 % ± 1 % ± 1 % at each day Total solar irradiance on collector plane Long wave irradiance on collector plane ± 10% between days Not defined. ± 50 W/m2 ± 50 W/m2 No requirement (dynamic variable) Not defined. ± 20 W/m2 ± 20 W/m2 No requirement (dynamic variable) Ambient temperature Not defined. ± 1 K ± 1 K ± 0.5 K Air speed Not defined. ± 10% ± 0.5 m/s ± 0.25 m/s Heat transfer fluid density Heat transfer fluid specific heat ± 0.5% during test ± 0.5% during test ± 1% during testing ± 1% during testing ± 1% during testing ±1% during testing ± 1 % during testing ± 1 % during testing Comments Solar Energy Laboratory Page 14 3/2/2007

3.1.3. Tables Table 6 Minimum range of thermal performance test conditions, ISO Standard 9806-3, Table 1 Table 7 Range of thermal performance test conditions, EN 12975-2, British version, Table 7 Table 8 Combination of inlet temperatures and weather conditions for test days, EN 12975-2, British version Mean plate temperature Clear sky Partly cloudy Ambient temperature ±3K Day 1 Day 2 (Ambient + hottest temperature) / 2 Day 3 Day 3 Hottest temperature (see Table 9) Day 4 Day 4 Table 9 Highest fluid temperature as a function of collector type, EN 12975-2, British version Collector type Hottest temperature (accuracy range not specified) Domestic hot water preparation Ambient temperature + 60 C District heating Ambient temperature + 70 C Swimming pools Ambient temperature + 15 C Process heating Ambient temperature + 90 C