Ultra- centrifugation (Gradient centrifugation), Viscometry, UV-VIS absorption spectroscopy, Mass spectrophotometery.

Similar documents
Instrumental technique. Manju C K

UNIT OPERASI BIOPROSES (UOB)

Spectroscopy. Page 1 of 8 L.Pillay (2012)

Because light behaves like a wave, we can describe it in one of two ways by its wavelength or by its frequency.

Compact Knowledge: Absorbance Spectrophotometry. Flexible. Reliable. Personal.

Electronic Excitation by UV/Vis Spectroscopy :

Centrifugation. There are several process functions using centrifuges in biotech separation. These are listed below.

Spectrophotometry. Introduction

9/28/10. Visible and Ultraviolet Molecular Spectroscopy - (S-H-C Chapters 13-14) Valence Electronic Structure. n σ* transitions

Chapter 13 An Introduction to Ultraviolet/Visible Molecular Absorption Spectrometry

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

TANDEM MASS SPECTROSCOPY

Lecture 0. NC State University

Spectrophotometry. Dr. Shareef SHAIK ASST. PROFESSOR Pharmacology

ADVANCED ANALYTICAL LABORATORY

Questions on Instrumental Methods of Analysis

two slits and 5 slits

SPECTROPHOTOMETRY AND SPECTROMETRY - CONCEPT AND APPLICATIONS

Course: M.Sc (Chemistry) Analytical Chemistry Unit: III

Basics of UV-Visible Spectroscopy *

A very brief history of the study of light

Reference literature. (See: CHEM 2470 notes, Module 8 Textbook 6th ed., Chapters )

levels. The signal is either absorbance vibrational and rotational energy levels or percent transmittance of the analyte

Ultraviolet-Visible and Infrared Spectrophotometry

3 - Atomic Absorption Spectroscopy

Infrared Spectroscopy: Identification of Unknown Substances

MOLEBIO LAB #4: Using a Spectrophotometer

4.3A: Electronic transitions

Paper: 12, Organic Spectroscopy Module: 5, Applications of UV spectroscopy

Absorption photometry

Ultraviolet-Visible and Infrared Spectrophotometry

Introduction to Mass Spectrometry (MS)

High Pressure/Performance Liquid Chromatography (HPLC)

World Journal of Pharmaceutical Research SJIF Impact Factor 8.074

Outline of Recombinant DNA technology. Application of UV spectroscopy in recombinant DNA technology

Spectroscopy: Introduction. Required reading Chapter 18 (pages ) Chapter 20 (pages )

Spectroscopy and Chromatography

Theory module: 11(MCQ) CENTRIFUGATION

Chapter 4 Ultraviolet and visible spectroscopy Molecular Spectrophotometry

1901 Application of Spectrophotometry

ZAHID IQBAL WARRAICH

Welcome to Organic Chemistry II

Microplate Spectrophotometer


Electrophiles are attracted to the π bond Addition sees a π bond replaced with a σ bond There are many different types of addition reactions:

ANALYSIS OF LOW DENSITY PARTICLES USING DIFFERENTIAL CENTRIFUGAL SEDIMENTATION

CHEM 241 UNIT 5: PART A DETERMINATION OF ORGANIC STRUCTURES BY SPECTROSCOPIC METHODS [MASS SPECTROMETRY]

Introduction to Pharmaceutical Chemical Analysis

Clinical Chemistry (CHE221) Professor Hicks Week 1. Statistics Made Slightly Less Boring and Introduction to Spectrophotometry. Accuracy vs Precision

Propose a structure for an alcohol, C4H10O, that has the following

sample was a solution that was evaporated in the spectrometer (such as with ESI-MS) ions such as H +, Na +, K +, or NH 4

Design and Development of a Smartphone Based Visible Spectrophotometer for Analytical Applications

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

Code Course name CFU Year G6403B Info not available 3 1

12. Structure Determination: Mass Spectrometry and Infrared Spectroscopy

Techniques useful in biodegradation tracking and biodegradable polymers characterization

MOLECULAR AND ATOMIC SPECTROSCOPY

CHEM Atomic and Molecular Spectroscopy

PAPER No. 12: ORGANIC SPECTROSCOPY MODULE No. 7: Instrumentation for IR spectroscopy

IR Spectrography - Absorption. Raman Spectrography - Scattering. n 0 n M - Raman n 0 - Rayleigh

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

Measuring S using an analytical ultracentrifuge. Moving boundary

GENERAL PHARMACOPOEIA MONOGRAPH

Chemistry Instrumental Analysis Lecture 15. Chem 4631

Chapter 17: Fundamentals of Spectrophotometry

Chapter 12 Mass Spectrometry and Infrared Spectroscopy

CHROMATOGRAPHY. The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments.

COURSE MATERIAL: Unit 3 (Part 1) Polymer Science LT8501 (Click the link Detail to download)

Absorption spectrometry summary

Colorimetry Extinction coefficient ( ) Lambda max ( max) Qualitative vs. quantitative analysis

09/05/40 MOLECULAR ABSORPTION METHODS

Instrumental Chemical Analysis

Course Details. Analytical Techniques Based on Optical Spectroscopy. Course Details. Textbook. SCCH 211: Analytical Chemistry I

Principles of Physical Biochemistry

3) In CE separation is based on what two properties of the solutes? (3 pts)

Chem 310 rd. 3 Homework Set Answers

UV-Vis optical fiber assisted spectroscopy in thin films and solutions

2001 Spectrometers. Instrument Machinery. Movies from this presentation can be access at

Chapter 4. Spectroscopy. Dr. Tariq Al-Abdullah

Molecular Luminescence Spectroscopy

Cork Institute of Technology. Summer 2005 Instrumental Analysis (Time: 3 Hours) Section A

Lecture- 08 Emission and absorption spectra

2501 High Performance Liquid Chromatography

Particle Characterization Laboratories, Inc.

Chromatography & instrumentation in Organic Chemistry

C101-E107B UV Shimadzu UV-VIS-NIR Spectrophotometer

高等食品分析 (Advanced Food Analysis) I. SPECTROSCOPIC METHODS *Instrumental methods: 1. Spectroscopic methods (spectroscopy): a) Electromagnetic radiation

UV-Vis Spectroscopy. Chem 744 Spring Gregory R. Cook, NDSU Thursday, February 14, 13

Chapter 17: Fundamentals of Spectrophotometry

Quality control analytical methods- Switch from HPLC to UPLC

CHEMISTRY (CHEM) CHEM 5800 Principles Of Materials Chemistry. Tutorial in selected topics in materials chemistry. S/U grading only.

FACULTY OF PHARMACY. M. Pharmacy I Semester (Suppl.) Examination, November 2015 (Common To All) Subject: Pharmaceutical Analytical Techniques

SECOND YEAR ORGANIC CHEMISTRY - REVISION COURSE Lecture 2 MOLECULAR STRUCTURE 2: SPECTROSCOPIC ANALYSIS

By: Ashley and Christine Phy 200 Professor Newman 4/13/12

Spectroscopy. a laboratory method of analyzing matter using electromagnetic radiation.

Spectroscopy. a laboratory method of analyzing matter using electromagnetic radiation

HOMEWORK - Chapter 4 Spectroscopy

Protein separation and characterization

1. The most important aspects of the quantum theory.

Sem /2007. Fisika Polimer Ariadne L. Juwono

Transcription:

Ultra- centrifugation (Gradient centrifugation), Viscometry, UV-VIS absorption spectroscopy, Mass spectrophotometery Mitesh Shrestha

Sedimentation Sedimentation describes the motion of molecules in solutions or particles in suspensions in response to an external force such as gravity, centrifugal force or electric force.

Sedimentation Theory solvent F C : The Centrifugal Force =M 0 * 2 * r solvent F B : the Buoyant Force (Archimedes) =M w * 2 * r F f : the Frictional Force = f * v Centrifugal force = buoyant force + frictional force

1. The Centrifugal Force Fc = M * w 2 * r 0 M o is the particle weight, or molecular weight (omega)= angular velocity (radians/sec) r is the radius of rotation This equation says that the larger the molecule, or the faster the centrifugation, or the longer the axis of rotation, the greater the centrifugal force and the rate of sedimentation.

The Centrifugal Force A more common expression is the relative centrifugal force (RCF): RCF 11.18* r * rpm 1000 2 r = Radial distance of particle from axis of rotation rpm = Revolutions per minute RCF reports centrifugal force relative to earth s gravitational force; commonly refer to as number times g. A sample rotating at 20, 000 rpm with r = 7 cm will experience RCF= 33,000 x g.

2.The Buoyant Force FB = Mw * w 2 * r The buoyant force opposes the centrifugal force. where Mw is the mass of the solvent displaced by the particle. The net force= (Fc-FB) will determine whether a particle floats or sediments Particles with higher density will experience smaller buoyant force, and thus, sediment faster.

The Frictional force Ff = f V Frictional force (resistance of a molecule to movement) v = velocity relative to the centrifuge tube, f = frictional coefficient.

The frictional coefficient depends upon: 1. the size 2.shape of the molecule, 3.the viscosity of the gradient material. The frictional coefficient f of a compact particle is smaller than that of an extended particle of the same mass.

Centrifuge Centrifuge is a piece of equipment, generally driven by a motor, that puts an object in rotation around a fixed axis, applying a force perpendicular to the axis. The centrifuge works using the sedimentation principle Theory: The amount of acceleration to be applied to the sample, rather than specifying a rotational speed such as revolutions per minute.

Centrifuge rotors axis of rotation Swinging-bucket At rest Spinning g g Fixed-angle

Geometry of rotors r max r av r min axis of rotation a r min r av r max r min r av r max b c Sedimentation path length

k -factor of rotors The k -factor is a measure of the time taken for a particle to sediment through a sucrose gradient The most efficient rotors which operate at a high RCF and have a low sedimentation path length therefore have the lowest k -factors The centrifugation times (t) and k -factors for two different rotors (1 and 2) are related by: t 1 k 1 k t 2 2

Calculation of RCF and Q RCF Q 11.18 x r 1000 2 Q 299 RCF r RCF = Relative Centrifugal Force (g-force) Q = rpm; r = radius in cm

Velocity of sedimentation of a particle v d 2 ( p l ) g 18 v = velocity of sedimentation p = density of particle g = centrifugal force d = diameter of particle l = density of liquid = viscosity of liquid

Differential centrifugation Density of liquid is uniform Density of liquid << Density of particles Viscosity of the liquid is low Consequence: Rate of particle sedimentation depends mainly on its size and the applied g-force.

Differential centrifugation of a tissue homogenate (I) Decant supernatant 1000g/10 min etc. 3000g/10 min

Differential centrifugation of a tissue homogenate (II) 1. Homogenate 1000g for 10 min 2. Supernatant from 1 3000g for 10 min 3. Supernatant from 2 15,000g for 15 min 4. Supernatant from 3 100,000g for 45 min Pellet 1 nuclear Pellet 2 heavy mitochondrial Pellet 3 light mitochondrial Pellet 4 microsomal

Differential centrifugation (IV) Poor resolution and recovery because of: Particle size heterogeneity Particles starting out at r min have furthest to travel but initially experience lowest RCF Smaller particles close to r max have only a short distance to travel and experience the highest RCF

Differential centrifugation (VI) Rate of sedimentation can be modulated by particle density Nuclei have an unusually rapid sedimentation rate because of their size AND high density Golgi tubules do not sediment at 3000g, in spite of their size: they have an unusually low sedimentation rate because of their very low density: ( p - l ) becomes rate limiting.

Density gradient centrifugation Density Barrier Discontinuous Continuous

How does a gradient separate different particles? Least dense Most dense

Applied Centrifugation Parameters you need to know: 1. Type of rotor: fixed angle, swinging bucket, vertical 2. Type of centrifuge: Low speed, high Speed, ultracentrifuge 3. Type of centrifugation Differential, preparative, or analytical Also, the Speed and duration of centrifugation

swinging bucket rotors: * Longer distance of travel may allow better separation * Excellent for gradient centrifugation *. Easier to withdraw supernatant without disturbing pellet 1. Types of Rotors fixed-angle rotors: * Sedimenting particles have only short distance to travel before pelleting. * Excellent for fractionation purposes * The most widely used rotor type. Other types include vertical rotors and continuous-flow rotors

2. Type of Centrifuge 2-1.Low-speed centrifuges Also called: microfuge, Clinical, Table top or bench top centrifuges Max speed ~ 20,000 rpm Operate at room temperature Fixed angle or swinging bucket can be used Commonly used for rapid separation of coarse particles E.g. RBC from blood, DNA from proteins, etc. The sample is centrifuged until the particles are tightly packed into pellet at the bottom of the tube. Liquid portion, supernatant, is decanted.

2-2. High-speed Centrifuges Preparative centrifuges. Max speed ~ 80,000 rpm Often refrigerated, and requires vacuum to operate Fixed angle or swinging bucket can be used Generally used to separate macromolecules (proteins or nucleic acids) during purification or preparative work. Can be used to estimate sedimentation coefficient and MW, No optical read-out

2-3. Ultracentrifuge The most advanced form of centrifuges: (specialized and expensive) Used to precisely determine sedimentation coefficient and MW of molecules, Molecular shape, Protein-protein interactions Uses very high speed and/or RCF Uses small sample size Uses relatively pure sample Built in optical system to analyze movements of molecules during centrifugation Analytical Ultracentrifuge

Ultracentrifuge The ultracentrifuge is a centrifuge optimized for spinning a rotor at very high speeds, capable of generating acceleration as high as 1,000,000 g (9,800 km/s²). There are two kinds of ultracentrifuges, the preparative and the analytical ultracentrifuge. Both classes of instruments are used in molecular biology, biochemistry and polymer science.

3. Types of Centrifugation There are basically three modes of centrifugation 3-1.Differential or pelleting Cellular fractionation and/or separating coarse suspension removal of precipitates crude purification step

3-2. Preparative or Density gradient centrifugation: Separation of complex mixtures Finer fractionation of cellular components Purification of proteins, nucleic acids, plasmids Characterization of molecular interactions

3-3. Analytical determining hydrodynamic or thermodynamic properties of biomolecules in the absence of solid supports (vs. electrophoresis, chromatography) Relative MW Molecular shape Aggregation behavior Protein-protein interactions

Analytical Ultracentrifugation Applications determine sample purity characterize assembly and disassembly mechanisms of biomolecular complexes determine subunit stoichiometries detect and characterize macromolecular conformational changes measure equilibrium constants and thermodynamic parameters for self- and hetero-associating systems characterize the solution-state behavior of macromolecules under various conditions

Viscosity Viscosity is a property that represents the internal resistance of a fluid to motion. The force a flowing fluid exerts on a body in the flow direction is called the drag force, and the magnitude of this force depends, in part, on viscosity.

Viscosity Measurement A viscometer (also called viscosimeter) is an instrument used to measure the viscosity of a fluid. For liquids with viscosities which vary with flow conditions, an instrument called a rheometer is used. Viscometers only measure under one flow condition.

U-tube viscometers Glass capillary viscometers or Ostwald viscometers.

Falling sphere viscometers

Bubble viscometer

Ultraviolet visible spectroscopy Ultraviolet visible spectroscopy or ultravioletvisible spectrophotometry (UV-Vis or UV/Vis) refers to absorption spectroscopy or reflectance spectroscopy in the ultraviolet-visible spectral region. Uses light in the visible and adjacent (near-uv and near-infrared [NIR]) ranges.

Ultraviolet visible spectroscopy Molecules containing π-electrons or non-bonding electrons (n-electrons) can absorb the energy in the form of ultraviolet or visible light to excite these electrons to higher anti-bonding molecular orbitals. The more easily excited the electrons, the longer the wavelength of light it can absorb. Based on the fact of four type of transition- π-π*,nπ*,σ-σ*,n-σ*. The energy required for various transitions obey the following order σ-σ*>n-σ*>π-π*>n-π*.

Ultraviolet visible spectroscopy The Beer-Lambert law states that the absorbance of a solution is directly proportional to the concentration of the absorbing species in the solution and the path length. Thus, for a fixed path length, UV/Vis spectroscopy can be used to determine the concentration of the absorber in a solution. It is necessary to know how quickly the absorbance changes with concentration. This can be taken from references (tables of molar extinction coefficients), or more accurately, determined from a calibration curve.

Assumptions

UV Spectroscopy sample reference detector II. Instrumentation and Spectra A. Instrumentation 1. The construction of a traditional UV-VIS spectrometer is very similar to an IR, as similar functions sample handling, irradiation, detection and output are required 2. Here is a simple schematic that covers most modern UV spectrometers: UV-VIS sources I 0 I log(i 0 /I) = A 200 700 l, nm monochromator/ beam splitter optics I 0 I 0 42

UV Spectroscopy II. Instrumentation and Spectra A. Instrumentation 3. Two sources are required to scan the entire UV-VIS band: Deuterium lamp covers the UV 200-330 Tungsten lamp covers 330-700 4. As with the dispersive IR, the lamps illuminate the entire band of UV or visible light; the monochromator (grating or prism) gradually changes the small bands of radiation sent to the beam splitter 5. The beam splitter sends a separate band to a cell containing the sample solution and a reference solution 6. The detector measures the difference between the transmitted light through the sample (I) vs. the incident light (I 0 ) and sends this information to the recorder 43

UV Spectroscopy sample II. Instrumentation and Spectra A. Instrumentation 7. As with dispersive IR, time is required to cover the entire UV-VIS band due to the mechanism of changing wavelengths 8. A recent improvement is the diode-array spectrophotometer - here a prism (dispersion device) breaks apart the full spectrum transmitted through the sample 9. Each individual band of UV is detected by a individual diodes on a silicon wafer simultaneously the obvious limitation is the size of the diode, so some loss of resolution over traditional instruments is observed UV-VIS sources Diode array Polychromator entrance slit and dispersion device 44

Components of instrumentation: Sources: Agron, Xenon, Deuteriun, or Tungsten lamps Sample Containers: Quartz, Borosilicate, Plastic Monochromators: Quarts prisms and all gratings Detectors: Pohotomultipliers

Biological chromophores 1. The peptide bonds and amino acids in proteins The p electrons of the peptide group are delocalized over the carbon, nitrogen, and oxygen atoms. The n-p* transition is typically observed at 210-220 nm, while the main p-p* transition occurs at ~190 nm. Aromatic side chains contribute to absorption at l> 230 nm 2. Purine and pyrimidine bases in nucleic acids and their derivatives 3. Highly conjugated double bond systems

Effects of solvents Blue shift (n- p*) (Hypsocromic shift) Increasing polarity of solvent better solvation of electron pairs (n level has lower E) peak shifts to the blue (more energetic) 30 nm (hydrogen bond energy) Red shift (n- p* and p p*) (Bathochromic shift) Increasing polarity of solvent, then increase the attractive polarization forces between solvent and absorber, thus decreases the energy of the unexcited and excited states with the later greater peaks shift to the red 5 nm

Spectral nomenclature of shifts

APPLICATION OF ULTRAVIOLET/VISIBLE ABSORPTION SPECTROMETRY Absorption measurements based upon ultraviolet and visible radiation find widespread application for the identification and determination of myriad inorganic and organic species. Molecular ultraviolet/visible absorption methods are perhaps the most widely used of all quantitative analysis techniques in chemical and clinical laboratories throughout the world.

UV Spectroscopy II. Instrumentation and Spectra D. Practical application of UV spectroscopy 1. UV was the first organic spectral method, however, it is rarely used as a primary method for structure determination 2. It is most useful in combination with NMR and IR data to elucidate unique electronic features that may be ambiguous in those methods 3. It can be used to assay (via l max and molar absorptivity) the proper irradiation wavelengths for photochemical experiments, or the design of UV resistant paints and coatings 4. The most ubiquitous use of UV is as a detection device for HPLC; since UV is utilized for solution phase samples vs. a reference solvent this is easily incorporated into LC design 51

Mass spectrometry (MS) Mass spectrometry (MS) is an analytical technique that ionizes chemical species and sorts the ions based on their mass to charge ratio. In simpler terms, a mass spectrum measures the masses within a sample. Mass spectrometry is used in many different fields and is applied to pure samples as well as complex mixtures. A mass spectrum is a plot of the ion signal as a function of the mass-to-charge ratio. These spectra are used to determine the elemental or isotopic signature of a sample, the masses of particles and of molecules, and to elucidate the chemical structures of molecules, such as peptides and other chemical compounds.

Mass spectrometry (MS) In a typical MS procedure, a sample, which may be solid, liquid, or gas, is ionized, for example by bombarding it with electrons. This may cause some of the sample's molecules to break into charged fragments. These ions are then separated according to their mass-to-charge ratio, typically by accelerating them and subjecting them to an electric or magnetic field: ions of the same mass-to-charge ratio will undergo the same amount of deflection. The ions are detected by a mechanism capable of detecting charged particles, such as an electron multiplier. Results are displayed as spectra of the relative abundance of detected ions as a function of the mass-to-charge ratio. The atoms or molecules in the sample can be identified by correlating known masses to the identified masses or through a characteristic fragmentation pattern.

How does a mass spectrometer work? Sample Ion source: makes ions Mass analyzer: separates ions Mass spectrum: presents information

What does a mass spectrometer do? 1. It measures mass better than any other technique. 2. It can give information about chemical structures. What are mass measurements good for? To identify, verify, and quantitate: metabolites, recombinant proteins, proteins isolated from natural sources, oligonucleotides, drug candidates, peptides, synthetic organic chemicals, polymers

Applications of Mass Spectrometry Pharmaceutical analysis Bioavailability studies Drug metabolism studies, pharmacokinetics Characterization of potential drugs Drug degradation product analysis Screening of drug candidates Identifying drug targets Biomolecule characterization Proteins and peptides Oligonucleotides Environmental analysis Pesticides on foods Soil and groundwater contamination Forensic analysis/clinical