British American Tobacco Group Research & Development. Method - Determination of ammonia in mainstream smoke

Similar documents
British American Tobacco Group Research & Development. Method - Determination of phenols in mainstream cigarette smoke

Method - Determination of aromatic amines in mainstream cigarette smoke

CORESTA Recommended Method No. 83

California Environmental Protection Agency Air Resources Board

Technical Report. Determination of Nitrite and Nitrate in Smokeless Tobacco Products by Ion Chromatography and Continuous Flow Analysis

Determination of Polymer Modifier in Asphalt

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Determination of urea in ultrapure water by IC-MS/MS

Determination of Trace Cations in Power Plant Waters Containing Morpholine

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF

USGS Troy WSC Laboratory Ion Chromatography SOP EPA 300.0, Rev Jordan Road SOP. No. 1 Rev. No. 1.7 Troy, NY Date 01/25/18 Page 1 of 7

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Sulfotepp impurities in Chlorpyrifos EC formulations

PA-DEP 3686, Rev. 1. Light Hydrocarbons in Aqueous Samples via Headspace and Gas Chromatography with Flame Ionization Detection (GC/FID)

The analysis of organic acid content of additives, premix, feed, and water.

Technical Procedure for Blood Cannabinoid Liquid-Liquid Extraction (BCLLE) for Analysis by LC-MS/MS

METHANOLYSIS OF ACETAL

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

LAP-013. Procedure Title: Date: 6/28/96. Author: Raymond Ruiz and Tina Ehrman ISSUE DATE: 8/26/96 SUPERSEDES: 11/01/94.

METHOD 7199 DETERMINATION OF HEXAVALENT CHROMIUM IN DRINKING WATER, GROUNDWATER AND INDUSTRIAL WASTEWATER EFFLUENTS BY ION CHROMATOGRAPHY

Determination of Inorganic Cations and Ammonium in Environmental Waters by Ion Chromatography Using the IonPac CS16 Column

EnAlgae SOP sheet: Silicate - SFA. 1. Purpose This procedure is to analyse seawater and freshwater for silicate, SiO2.

Standard Operating Procedure for the Analysis of Chloride, Bromide and Sulfate in Fresh Waters by Ion Chromatography CCAL 50B.2

ACETIC AND FORMIC ACIDS IN WORKPLACE ATMOSPHERES ppm for Acetic Acid, CH 3 COOH

IonPac Trace Cation Concentrator

Determination of Anions and Cations on Multi (2) - Ion Chromatography System

Technical Procedure for Solid Phase Extraction of THC and THC-COOH for GC-MS Analysis

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

Anethole. Gas chromatograhpy determination of trans-anethole in Spirit srinks of viti-vinicultural origin

Fast methods for the determination of ibuprofen in drug products

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

STANDARD OPERATING PROCEDURES

CORESTA Recommended Method No. 86

Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry

Determination of Sulfate and Chloride in Ethanol by Ion Chromatography

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

HPLC Praktikum Skript

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS

Determination of Organic Acids and Inorganic Anions in Lithium-Containing Boric Acid-Treated Nuclear Power Plant Waters

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

ONDERSTEPOORT VETERINARY INSTITUTE METHOD: RTETH 042 DETERMINATION OF TETRACYCLINES IN HONEY 1. INTRODUCTION 2. EQUIPMENT

Determination of Methylamine in Drug Products

-xt. -xt SYSTEM. Specifications for PAL-xt Systems. Valid for PAL-xt System models only. Prep and Load Platform

Scope: Materials: Labeled 1.5 ml or 2 ml Eppendorf tubes Appropriate pipette tips (see Table 1) Labeled LC vials

Chemistry Gas Chromatography: Separation of Volatile Organics

Cyanide and sulfide analysis using amperometric detection and Metrosep A Supp /4.0

ACETONE IN URINE BY UV CODE Z42010

METHADONE and EDDP in urine by GC-MS Code GC Method of Confirmation by GC-MS

BUTYL ALCOHOL in urine by GC-FID Code GC05510

Pelagia Research Library

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples

DIQUAT DIBROMIDE. The Determination of Ethylene Dibromide in Diquat Dibromide and Diquat Dibromide / Paraquat Dichloride SL Formulations

Appendix II- Bioanalytical Method Development and Validation

25-OH VITAMIN D 3 AND 25-OH VITAMIN D 2 IN PLASMA BY UV / VIS FAST CODE Z19710

2011_ST20_Taylor.pdf. SSPT Document not peer-reviewed by CORESTA

Determination of trace anions in concentrated hydrofluoric acid

Determination of Tartaric Acid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection

IDENTIFICATION OF STEROIDS IN COSMETIC PRODUCTS BY TLC AND HPLC 1 02/12/2005 ACM 007 A. THIN LAYER CHROMATOGRAPHY (TLC)

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

ANALYTICAL METHOD PROCEDURES

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

HYDROGEN CYANIDE 6017

Determination of Hexavalent Chromium in Drinking Water Using Ion Chromatography

Diquat 1,1 -ethylene-2,2 -bipyridium dibromide salt Paraquat 1,1 -dimethyl-4,4 -bipyridium dichloride salt Initial Preparation

Automated Sample Preparation in Quality Control of Eye-Drop Formulation

NORBUPRENORPHINE (Buprenorphine s Metabolite ) BUPRENORPHINE in urine by GC/MS Code GC Method of Confirmation by GC-MS

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

DISCLAIMER: This method:

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

RESOLUTION OENO 33/2004 DETERMINATION OF SHIKIMIC ACID IN WINE BY HPLC AND UV-DETECTION

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Determination of Silicate in High Purity Water Using Ion Chromatography and AutoPrep

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

CIPAC. CIPAC Free relevant impurities methods:

Expanded capabilities in ammonium and amine detection

PYRIPROXYFEN TECHNICAL

Determination of trace anions in high-nitrate matrices by ion chromatography

INTERNATIONAL CHEMISTRY TESTING. 258 Main Street- Suite 311- Milford, MA Tel: Fax:

Impact factor: 3.958/ICV: 4.10 ISSN:

Research Article METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF ELBASVIR AND GRAZOPREVIR BY RP-HPLC

Quantitative determination of ethephon in soluble concentration (SL) by Ion chromatography

Dionex IonPac AS28-Fast-4µm column

User Manual. IonPac NS2 Columns Revision 02 October For Research Use Only. Not for use in diagnostic procedures.

Determination of trace anions in high-purity waters by high volume/direct injection ion chromatography

Standard Operating Procedures. Determination of Anions and/or Cations Extracted from Nylon Filters by Ion Chromatography (IC)

METHOD: 1403, Issue 3 EVALUATION: FULL Issue 1: 15 August 1990 Issue 3: 15 March 2003

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Quality Assurance is what we do to get the right answer for our purpose FITNESS FOR PURPOSE

[ 18 F]FALLYPRIDE FOR INJECTION: MASTER BATCH RECORD

HIPPURIC ACID and o-m-p- METHYLHIPPURIC ACIDS IN URINE BY UV CODE Z06010

METHOD 7B - DETERMINATION OF NITROGEN OXIDE EMISSIONS FROM STATIONARY SOURCES (ULTRAVIOLET SPECTROPHOTOMETRIC METHOD)

Determination of Volatile Substances Proof of Food Adulteration

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Transcription:

British American Tobacco Group Research & Development Method - Determination of ammonia in mainstream smoke 1 SCOPE OF APPLICATION The method is applicable to quantitative determination of the yields of ammonia in whole mainstream cigarette smoke, using ion chromatography with conductometric detection. 2 NORMATIVE REFERENCES ISO 3308:2000 - Cigarettes Routine Analytical Cigarette smoking machine Definitions and standard conditions ISO 3402:1999 - ISO 4387:2000 ISO 8243:2006 - Tobacco and tobacco products Atmospheres for conditioning and testing fourth edition Cigarettes - Determination of total and nicotine-free dry particulate matter using a routine analytical smoking machine Cigarettes - Sampling 3 PRINCIPLE Five conditioned cigarettes are smoked using a modified linear 20 port smoking machine to accommodate liquid trapping systems. The mainstream smoke is collected into 2 liquid impingers containing sulphuric acid. After smoking the impinger solutions are combined and diluted using 0.05M sulphuric acid. An aliquot of the resulting solution is submitted for analysis by ion chromatography using conductometric detection. 4 HEALTH & SAFETY Read and understand the Material Safety Data Sheets for the chemicals used in this method. Read and understand the method risk assessment. Ensure that you understand the hazards and follow control measures relevant to the operation of this method. All preparation of standards and extraction of samples must be performed in a fume cupboard. 5 REAGENTS AND MATERIALS All reagents are Analytical Grade or equivalent unless otherwise stated. 2 x Ammonium ion Stock Standard solution 1000 µg NH + 4 /ml (must be different batches) Sulphuric Acid, 0.05M Convol De-ionised water at 18.2 MΏ Methanol (HPLC grade) Helium gas Methanesulfonic Acid EluGen Cartridge 6 APPARATUS Borgwaldt-KC LM20 linear 20 port smoke engine. adapted for use with liquid traps Smoke collection system for each port: A suitable trapping system has been constructed from Quickfit tubes and Dreschel heads. Soap bubble manometer to measure puff volume Analytical balance capable of measuring to at least four decimal places Page 1 of 7

1mL pipette (Class A) 2mL pipette (Class A) 4mL pipette (Class A) 5mL pipette (Class A) 1mL Pasteur pipettes 20mL borate glass sample tubes Standard 2mL HPLC vials and caps 1L Volumetric Flask (Class A) 25mL Volumetric Flasks (Class A) 20mL Volumetric Flasks (Class A) 50mL Volumetric Flasks (Class A) Dispenser suitable for weak acids Dionex Ion Chromatograph IonPac CS12A column (8.5µm x 250 x 4mm) IonPac CG12A guard column (8.5µm x 50 x 4mm) 7 PRELIMINARY SAMPLE PREPARATION Cigarettes should be conditioned according to normal procedures (ISO 3402:1999). Unless specifically requested, cigarettes are not subject to any selection criteria other than the rejection of any obviously defective or damaged cigarettes. Butt marking is as specified in ISO 4387:2000 unless otherwise requested. 8 ANALYTICAL PROCEDURE SOLUTION PREPARATION 8.1 Extracting Solution To a 1L volumetric flask (class A) containing approximately 50mL deionised water add one 0.05M Convol of sulphuric acid. Make up to volume with deionised water. 8.2 Needle wash solution Deionised water containing 5% by volume of methanol. 8.3 Pre-mobile Phase Deionised water, the mobile phase which passes through the column is produced in-situ by the eluent generator unit on the ion chromatograph instrument. 8.4 20µg/mL Stock standard solution Pipette 1mL of the purchased 1000µg/mL ammonium ion solution into a 50mL volumetric flask (class A) and make up to volume with 0.05M sulphuric acid. 8.5 Calibration Standards Dilute the 20µg/mL stock solution (see 8.4) as follows into 20 and 25mL volumetric flasks (class A). Make to volume using 0.05M Sulphuric Acid. Page 2 of 7

Calibration Standard Concentration of NH 4 + Standard Volume of 20µg/mL stock solution (ml) Final volume (ml) 6 5 µg/ml 5 20 5 3.2 µg/ml 4 25 4 2 µg/ml 2 20 3 1 µg/ml 1 20 2 0.5 µg/ml 2 from Std 6 20 1 0.1 µg/ml 2 from Std 3 20 8.6 QC Stock Solution Pipette 1mL of the 2 nd purchased 1000µg/mL ammonium ion solution into a 50mL volumetric flask (class A) and make up to volume with 0.05M sulphuric acid. This Stock is used to make up the working QC standard 8.7 QC Standard Solution (1.6µg/mL) Pipette 2mL of the QC Stock Solution (see 8.6) into a 25mL volumetric flask and make to volume with 0.05M Sulphuric Acid. 9 ANALYTICAL PROCEDURE SAMPLE PREPARATION 9.1 Sample Collection Preparation of liquid traps This method utilises two liquid impingers attached in series to the back of each smoking port. This is a deviation from the ISO Method 3308:2000. Prior to smoking allow the smoking machine to warm up for 30 minutes and measure airflow in ports 1, 10 and 20 with an airflow probe. Individual port readings should be 200mm/sec (±50mm/sec) and the average airflow across the measured ports should be 200mm/sec (± 30mm/sec). 9.1.1 Assembly of trapping system Assemble the ammonia trapping system behind the cigarette holder as shown below, with each trap containing 20mL 0.05M sulphuric acid delivered from a pre-set dispenser. Page 3 of 7

N.B. Take great care to ensure that the traps are connected correctly otherwise instrument damage can occur. Check the system for leaks by taking a puff and ensuring liquid does not siphon back up the impinger tube. Check the puff volumes with the traps in position and adjust if necessary. Puff volumes should be 35ml ± 0.3mL (for ISO smoking). 9.1.2 Smoking Smoke 5 conditioned cigarettes through each trapping system. One clearing puff is taken between each cigarette run, and a further five clearing puffs are taken at the end of the run to ensure any residual smoke has been collected in the trapping solution. Record the number of lit puffs. 9.2 Sample Extraction The two impingers are combined and an aliquot of approximately 1mL is added to an HPLC vial and capped. 10 ANALYTICAL PROCEDURE INSTRUMENTAL ANALYSIS 10.1 Instrument Set Up Parameters Analysis is performed on a Dionex Ion Chromatograph fitted with autosampler, eluant generator and conductometric detector. A 25µL injection loop is used and the injection volume of all samples is 25µL. The gradient profile is shown in the table below: Time (min) Conc. Of MSA (mm) Eluant Generator Curve Flow Rate (ml/min) Suppressor Current (ma) 0.0 18 5 1.00 88 7.0 18 5 1.00 88 7.1 40 5 1.00 88 13.0 40 5 1.00 88 13.1 18 5 1.00 88 18.00 18 5 1.00 88 Auto-sampler tray temperature 10 C Column temperature 30 C Syringe speed 5 Pressure range 200 psi (min) and 3000 (max) Flush volume 250µL Needle height 2mm 10.2 System Suitability Criteria R 2 of calibration curve should be greater than 0.98 The peak area of the lowest standard should be not less than 0.015µSiemens*minutes. The peak area of the blank should not exceed 25% of that of the lowest standard. Page 4 of 7

Check that the peak shapes, especially those of sodium and ammonium, are well-resolved. peak. If peak shapes are significantly non-ideal, e.g. tailing, consider replacing guard or column. The ammonium ion peak will elute in the range 5.00 5.60 mins (18mM methanesulphonic acid mobile phase) and will be the second prominent peak (after sodium ion elution at approximately 4.5 min). Reference cigarette results within defined limits Quality control solution results within defined limits 10.3 Run Order Start the run with 2 blank 0.05M sulphuric acid samples Calibration standards in desceding order QC standard Blank 0.05M Sulphuric Acid 10 samples (including a reference cigarette sample) QC standard Blank 0.05M Sulphuric Acid 10 samples (including a reference cigarette sample) QC standard etc 11 CALCULATIONS In order to obtain the value of the amount of ammonium ions released per cigarette, the concentration of the cigarette measurement is multiplied by 40 (volume in ml of trapping solution) and divided by 5 (number of cigarettes smoked). To convert µg/ml of ammonium ions into µg/ml of ammonia it is necessary to multiply by the factor 17/18. Calculate the concentration of ammonia (µg/cigarette) from the formula: - Ammonia (µg/cigarette) = C * V * 17 / N * 18 Where C = Concentration of ammonia (µg/ml) as determined by ion chromatograph software V = Total volume of sample (normally 40 ml) N = Number of cigarettes smoked 12 PRECISION AND REPORTING LIMITS Five replicate smokings and analyses are performed to determine the precision of the analysis. Longer term precision is monitored through the maintenance of control charts. The lower reporting limit is defined by the concentration of the lowest calibration standard, and equates to 0.8µg/cigarette. 13 QUALITY ASSURANCE AND CONTROL Control charts of the QC standard and the reference cigarette are maintained to allow inspection of the method performance. 14 SPECIAL CASES Under more intense regimes the number of cigarettes or the volume of acid in the liquid impingers may need to be adjusted in order to avoid saturating the liquid traps with smoke condensate. Page 5 of 7

Date of Issue: 31 March 2008 Page 6 of 7

APPENDIX A SAMPLE CHROMATOGRAMS Typical standard chromatogram Typical smoke sample chromatogram Page 7 of 7