Alden Test Results On AMITY Insert Venturi

Similar documents
Flow Measurement in Pipes and Ducts COURSE CONTENT

04/01/1998 Developments in DP Flowmeters By Jesse Yoder

The Expansibility Factor Equations in ISO and ISO : Do They Deliver What They Promise?

NORTH SEA FLOW MEASUREMENT WORKSHOP 2004 In. St Andrews, Scotland

Lecture 13 Flow Measurement in Pipes. I. Introduction

POWER UNDERSTANDING MEASUREMENT UNCERTAINTY IN DP FLOW DEVICES

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH

Measurements using Bernoulli s equation

Lecture23. Flowmeter Design.

Computation of pressure loss for differential producing flowmeters

FINAL DRAFT: October 25, 2010 API TECHNICAL REPORT FUEL GAS MEASUREMENT. FINAL DRAFT: October 25, 2010 Page 0

ABSTRACT I. INTRODUCTION

Experiment (4): Flow measurement

Discharge coefficient behaviour in presence of four perforated plates flow conditioners - Numerical investigation Part 1-

Orifice and Venturi Pipe Flow Meters

Flow Measurement in Pipes and Ducts COURSE CONTENT

Applied Fluid Mechanics

Applied Fluid Mechanics

Smart DP Flow Metering A summary of Established Technology and Latest Innovation. Gary Fish

MCE380: Measurements and Instrumentation Lab

Flow Measurement in Pipes and Ducts

Process Gas Flow Measurement and Performance Evaluation API TECHNICAL REPORT 2571 SECOND EDITION DRAFT, FEBRUARY 2018

CALCULATION OF COEFFICIENT OF DISCHARGE OF ORIFICE PLATE AND FLOW NOZZLE

SAMPLE SHEET. Supply of PF Process Calculation Spreadsheet (Excel Forma)

Experiment No.4: Flow through Venturi meter. Background and Theory

Diagnostic System for Venturi Meters

Lecture 24. Design of flow meters

Flowmeter Discharge Coefficient Estimation

ISO 9906 INTERNATIONAL STANDARD. Rotodynamic pumps Hydraulic performance acceptance tests Grades 1 and 2

Mechanical Measurements and Metrology Prof. S. P. Venkateshan Department of Mechanical Engineering Indian Institute of Technology, Madras

Discharge Coefficient Behaviour in Presence of Four Perforated Plates Flow Conditioners

ME 4600:483 Lab Notes Revised 11/16/2015. Flow Measurement

Flow rate and mass flow rate

Orifice and Venturi Pipe Flow Meters

Measurement of fluid flow in closed conduits

FLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560

MEDIDAS EN FLUIDOS. INEL 5205 Instrumentación. Monday, November 19, 12

CHOKING PRESSURE RATIO GUIDELINES FOR SMALL CRITICAL FLOW VENTURIS AND THE EFFECTS OF DIFFUSER GEOMETRY

Differential Pressure Producing Flow Elements

Head loss coefficient through sharp-edged orifices

) where the inlet pressure ( P 1

ME332 FLUID MECHANICS LABORATORY (PART I)

SELECCIÓN DE CAUDALIMETROS. Tablas de Fabricantes

5 ENERGY EQUATION OF FLUID MOTION

Mass of fluid leaving per unit time

Experimental and CFD analysis of flow through venturimeter to determine the coefficient of discharge

CHAPTER 3 BASIC EQUATIONS IN FLUID MECHANICS NOOR ALIZA AHMAD

FLOW MEASUREMENT IN PIPES EXPERIMENT

VENTURIMETER EXPERIMENT

CHAPTER THREE FLUID MECHANICS

New Website: Mr. Peterson s Address:

S.E. (Mech.) (First Sem.) EXAMINATION, (Common to Mech/Sandwich) FLUID MECHANICS (2008 PATTERN) Time : Three Hours Maximum Marks : 100

Energy Losses in Cross Junctions

[Prasanna m a*et al., 5(6): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

Prediction of Performance Characteristics of Orifice Plate Assembly for Non-Standard Conditions Using CFD

DESIGN AND PERFORMANCE OF THE CONVERGING-DIVERGING VORTEX FLOWMETER

N. Zhang, W.-J. Yang and Y. Xu Department of Mechanical Engineering and Applied Mechanics, The University of Michigan, Ann Arbor, MI 48109, USA

Lecture 3 The energy equation

CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT. Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG

Fundamentals of Flow Metering

ASME V & V Symposium, May, 2012

STRUCTURAL ANALYSIS OF A WESTFALL 2800 MIXER, BETA = 0.8 GFS R1. By Kimbal A. Hall, PE. Submitted to: WESTFALL MANUFACTURING COMPANY

Roll No. :... Invigilator s Signature :.. CS/B.Tech (EIE)/SEM-5/EI-501/ INDUSTRIAL INSTRUMENTATION II

Bounding the Uncertainties of the Meter Factors for LEFM CheckPlus Flow Elements in Feedwater Flow Measurements

Comparison of Selected Differential Producing, Ultrasonic, and Magnetic Flow Meters

CHAPTER (13) FLOW MEASUREMENTS

DETERMINATION OF DISCHARGE AND HEAD LOSS USING A FLOW-MEASURING APPARATUS

COMPUTATIONAL INVESTIGATION OF PERFORMANCE CHARACTERISTICS IN A C-SHAPE DIFFUSING DUCT

THE GEOTHERMAL TWO-PHASE ORIFICE PLATE

Flow Measurement: Physical principle employed in various types of flow meters. PART 4 PREPARED BY: ESO OLUWATOBILOBA

BRCM COLLEGE OF ENGINEERING & TECHNOLOGY Practical Experiment Instructions Sheet

Calibration of Orifice Flow Meter and Venturi Flow Meter

Annubar Primary Element Flow Calculations

INTERNATIONAL OIML D 25 DOCUMENT. Vortex meters used in measuring systems for fluids ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Predictionof discharge coefficient of Venturimeter at low Reynolds numbers by analytical and CFD Method

Standard Test Method for Measuring Acoustical and Airflow Performance of Duct Liner Materials and Prefabricated Silencers 1

Qsl < > ARNOLD ENGINEERING DEVELOPMENT CENTER

Experimental Study on Port to Channel Flow Distribution of Plate Heat Exchangers

ERRATA CRANE FLOW OF FLUIDS THROUGH VALVES, FITTINGS AND PIPE TECHNICAL PAPER NO. 410 METRIC VERSION

Volume and Mass Flow Rate Measurement Author: John M. Cimbala, Penn State University Latest revision: 07 December 2007

ALASTAIR MCLACHLAN Applications Cameron

CALCULATION OF DISCHARGE COEFFICIENT IN COMPLEX OPENING (LAMINAR FLOW)

DISCHARGE COEFFICIENT OF SMALL SONIC NOZZLES

I. To find the coefficient of discharge for vcnturi meter. 2. To find the coefficient of discharge for ori rice meter.

Experimental Investigation of the Fluid Dynamics of a Finned Heat Sink under Operating Conditions

SAMPLE FORMAL REPORT A

Large Rocket Engine Environments

Investigation of Flow Profile in Open Channels using CFD

Compressible Gas Flow

57:020 Mechanics of Fluids and Transfer Processes CONSERVATION OF MASS, LINEAR MOMENTUM, AND ENERGY IN A SLUICE GATE FLOW. dt dt. d ( momentum.

ABSTRACT I. INTRODUCTION

DESIGN & COMPUTATIONAL FLUID DYNAMICS ANALYSES OF AN AXISYMMETRIC NOZZLE AT TRANSONIC FREE STREAM CONDITIONS

Effect of multiple jet impingement plate configurations on Reynolds Number in a pipe

Theory and Design for Mechanical Measurements

V-Cone Flowmeter DATASHEET

General Principles of LEFM Time-of-Flight Ultrasonic Flow Measurements

EXPERIMENTAL INVESTIGATION OF THE INSTALLATION EFFECTS ON THE VENTURI FLOWMETER PERFORMANCE

Transcription:

Alden Test Results On AMITY Insert Venturi Richard W. Miller PhD, PE A laboratory test was performed on an AMITY designed insert Venturi at the Alden on October 27, 2009 to obtain the coefficient of discharge (C). An Air Products representative witnessed the Test along with personnel from AMITY flow. The meter being crated is shown in Figure 1. Figure 1 Air Products AMITY 36 Venturi 1

The ALDEN laboratory flow circuit is shown in Figure 2 During installation it was noted Figure 2 ALDEN Flow Circuit 1. The meter s centerline was eccentric with respect to the pipe centerline; a result of the laboratories flange bolt circle not bein the same as the meter. 2. The upstream tap to throat tap distance was not as specified by AMITY or per Air Products specifications. (Approximately 1 pipe diameter). Customarily ALDEN runs high, mid range and low flow-rate data points to establish any calibration or meter problems before a full test. It was noted that the low flow rate point was lower than expected by approximately 0.35%. A subsequent repeat indicates an increase in coefficient (at the same Reynolds number) of 0.31 %. 2

These results are most probably caused by 1. The bore of the meter and meter orientation within the pipe had not reached full thermal equilibrium. (Laboratory water temperature= 103 0 F) 2. Increased white noise at the upstream pressure tap resulting from meter eccentricity. 3. The leads to the differential pressure transmitters acts like a zero offset due to different temperature within the leads. Sufficient upstream piping provided a fully developed flow at the Venturi entrance. Preliminary ALDEN results are presented in Figure 3. The initial three data may have a dimensional, orientation, or lead line temperature bias; however, test results are in excellent agreement with boundary layer theory, suggesting a minimal effect (estimated <0.05 %) Figure 3 ALDEN data 3

Discharge Coefficient, Cd Discharge Coefficent vs. Throat Reynolds Number 1.0000 0.9950 0.9900 0.9850 0.9800 0.9750 C 0.99471 0.2 R d 0.9700 1.0E+05 1.0E+06 1.0E+07 Throat Reynolds Number, Rd Figure 4 Plot of ALDEN data Data Analysis: The AMITY meters are designed such that the throat area is in accordance with the exacting requirement for the ASME PTC-6 nozzle. This throat is the controlling area that defines meter performance. The literature clearly indicates that a throat area and properly manufactured pressure tap will replicate and be predicable to the boundary layer theory presented in numerous papers. This design objective has been verified by test results at ALDEN for all of the AMITY meters. The AMITY sizing Program incorporated this theory (see References) in the design of the meter for Reynolds number pressure and temperature effects. 1. Tap geometry and fabrication 2. Throat entrance streamline 3. Throat surface finish 4. Required circularity Excluding data point 3 following extrapolation equation is derived from the ALDEN data using the recommended PTC-6 method. Cd 0.99471 0.2 R d The constant 0.99471 is the discharge coefficient at infinite Reynolds number and its values depends on the inlet geometry design. A Computational Fluid Dynamic (CFD) study of the fabricated meter is shown in Figure 5. 4

Figure 5 CFD Study For the normal operating Bore Reynolds number the extrapolated Coefficient is Cd 0.99471 6472868.51919 Cd 0.98766278.2 The extrapolated discharge coefficient is expected to be within 2 0.1% References ANSI/ASME PTC 19.1 Part 1 Measurement Uncertainty ASME, NY ANSI/ASME PTC-6 Steam Turbines (performance test code), ASME. 1976 ASME, Fluid Meters Their Theory and Application, ASME 1971 ASME-MFC 2M Measurement Uncertainty for Fluid Flow in Closed Conduits, ASME, NY ASME-MFC 3M Measurement of Fluid Flow in Pipes Using Orifice, Nozzle, and Venturi, ASME, NY ASME-MFC 8M Fluid Flow in Closed Conduits: Connections for Pressure Signal Transmissions Beitler, S.R. Flow Nozzle Coefficient Tolerances, ASME Paper 72-WA-FM-7 Brunkalla, R.L., "Effects of Fabrication Technique on the Discharge Coefficient of a Throat Tap Nozzle" ASME Paper 85-JPGC-PTC-3, 1985 Cotton, K.C. and Westcott, J.C., Throat Tap Nozzles Used for Accurate Flow Measurements, Jrl for Pwr, October 1960 Cotton, K.C., et al Experience With Throat-Tap Nozzles for Accurate Measurement ASME Paper 71-WA/PTC-1, 1971 Hall, G.W. Application of Boundary Layer Theory to Explain some Nozzle and Venturi Peculiarities Trans. IME, London Vol. 173 No.36 1959 Hall, G.W. Applications of Boundary Layer Theory to Explain Some Nozzle and Venturi Peculiarities Ins. of Mech. Engr, London 10.59 1969 ISO 5167 Part 3: Nozzle and Venturi nozzles, ISO Keyser, D.R., et al Theoretical Basis for Extrapolation of Calibration Data of PTC-6 Throat Tap Nozzles, Jrl Pwr, JPGC-PTC28-4, 1990 Miller, R.W. Flow Measurement Engineering Handbook McGraw Hill Book Company, NY Rainbird, W.J. Errors in Measurement of Mean Static Pressure of a Moving Stream Due to Pressure Holes DME/NAE, 1967 Rayle, R.E. Influence of Orifice Geometry on Static Pressure Measurements ASME Paper No. 59-A 234 Rivas, R.A. and Shapiro, A.H On The Theory of Discharge Coefficients for Rounded-Entrance Flowmeters and Venturis, ASME Paper 54-A-98 5