High-Performance Chromatography Superior isocratic separation of

Similar documents
Thermo Scientific Dionex IonPac CS17 Cation-Exchange Column

columns IonPac SCS 1 Silica Cation Separator

columns IonPac AS17-C Anion Exchange Column

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

anion-exchange column

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Dionex IonPac AS28-Fast-4µm column

columns IonPac AS18 Anion-Exchange Columns

Determination of Trace Cations in Power Plant Waters Containing Morpholine

columns IonPac AS22 Anion-Exchange Column

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

Thermo Scientific. Anion-Exchange Column

Expanded capabilities in ammonium and amine detection

PRODUCT MANUAL. for the. IONPAC CG14 GUARD COLUMN (2 x 50 mm, P/N ) (4 x 50 mm, P/N )

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection

Product Manual for Dionex IonPac CS12A and CG12A Columns

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

columns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s

IonPac Trace Cation Concentrator

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

IonPac SCS 1 IonPac SCG 1

Concentrator and Trap Columns. Column: IonPac AG15, AS15, 2 mm. Eluent Source: EG40 Concentrator. Temperature: 30 C Column: IonPac AC15 (2 50 mm)

Determination of trace anions in concentrated hydrofluoric acid

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Thermo Scientific Dionex IonPac AS26 Anion-Exchange Column

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column

suppressors SRS -ULTRA Self-Regenerating Suppressor

Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water

Thermo Scientific Dionex IonPac AS24A Anion-Exchange Column

Cation Exchange HPLC Columns

Determination of Inorganic Cations and Ammonium in Environmental Waters by Ion Chromatography Using the IonPac CS16 Column

Determination of urea in ultrapure water by IC-MS/MS

Determination of Methylamine in Drug Products

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column

Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC

Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography

Determination of Tartaric Acid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection

Thermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column

Overcoming Challenging Matrices in Ion Chromatography

suppressors Eluent Suppressors for Ion Chromatography

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

groups I and II cations, amines, divalent transition metals

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Determination of Trace Anions in Organic Solvents

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Keywords Haloacetic acids, Water analysis, 2-D ion chromatography, ICS-3000

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples

ION CHROMATOGRAPHY SYSTEM S 150

PRODUCT MANUAL OMNIPAC PCX-500 GUARD COLUMN (PCX-500 GUARD, P/N ) OMNIPAC PCX-500 ANALYTICAL COLUMN (PCX-500 ANALYTICAL, P/N )

Determination of Sulfate and Chloride in Ethanol by Ion Chromatography

Direct Determination of Small Organic Acids in Sea Water by IC-MS

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Sample Preparation for Ion Chromatography

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

Determination of an anionic fluorochemical surfactant in a semiconductor etch bath

Determination of Inorganic Anions in Drinking Water by Ion Chromatography

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

Inline sample preparation for the determination of anions in sodium hydroxide

IC Columns Introduction

Determination of Silicate in High Purity Water Using Ion Chromatography and AutoPrep

Cation Exchange HPLC Columns

Shodex TM ODP2 HP series columns

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Simultaneous Determination of Pharmaceutical Peptides and Acetate Counterions by HPLC Using a Mixed-Mode Weak Anion-Exchange Column

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

Determination of trace anions in high-purity waters by high volume/direct injection ion chromatography

Determination of Inorganic Anions in Wastewater by Ion Chromatography

User Manual. IonPac NS2 Columns Revision 02 October For Research Use Only. Not for use in diagnostic procedures.

The Determination of Trace Anions in Concentrated Phosphoric Acid

[ Care and Use Manual ]

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

ProPac WCX-10 Columns

Utility of the Charge Detector in Ion Chromatography Applications

Determination of Cr(VI) in Water, Waste Water, and Solid Waste Extracts

Novel Electrodeionization Devices: Applications in Inorganic Analysis

Thermo Scientific Dionex eluent suppressors for ion chromatography

Easy Method Transfer from HPLC to RSLC with the Dionex Method Speed-Up Calculator

Determination of Trace Cations in Concentrated Acids Using AutoNeutralization Pretreatment and Ion Chromatography

A Total Solution for Explosives Analysis by Reversed-Phase HPLC with a Parallel HPLC System

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

for IonPac AG11-HC IonPac AS11-HC

4. Ion chromatography (IC) 4.1. Educational aims and objectives

ISO INTERNATIONAL STANDARD

Application of Eluent Generation for Trace Anion Analysis of Borated Waters

User Manual. IonPac NS1 Columns Revision 07 November For Research Use Only. Not for use in diagnostic procedures.

Determination of Hexavalent Chromium in Drinking Water Using Ion Chromatography

Fast Protein and Peptide Separations Using Monolithic Nanocolumns and Capillary Columns

Determination of Organic Acids and Inorganic Anions in Lithium-Containing Boric Acid-Treated Nuclear Power Plant Waters

HPLC Praktikum Skript

Determination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

Determination of trace anions in basic solutions by single pass AutoNeutralization and ion chromatography

The determination of trace anions in concentrated phosphoric acid

Transcription:

columns I o n P a c C S A C a t i o n - E x c h a n g e C o l u m n The IonPac CSA cation-exchange column provides fast analysis of mono- and divalent cations, ammonium, and aliphatic amines simultaneously using methanesulfonic or sulfuric acid eluents. The column resin is functionalized with a mixture of carboxylic acid and phosphonic acid groups, which permit excellent peak shape and efficiency for amines. Manganese is easily separated from calcium and magnesium with the use of a simple isocratic methanesulfonic acid eluent. The IonPac CSA µm ( x mm) column is a high-efficiency column for very fast separations of common inorganic cations. The IonPac CSA-MS ( x mm) column is specifically designed for IC-MS detection. High-Performance Chromatography Superior isocratic separation of mono- and divalent cations, ammonium, and aliphatic amines simultaneously using methanesulfonic acid (MSA) or sulfuric acid eluents. Ideal for analyzing inorganic cations and amines in drinking water, power plant waters, soil extracts, acid digests, chemical additives, chemical process solutions, scrubber solutions, plating baths, and solvents. Quick and efficient: Fast analysis time of min for similar cation concentrations using the high-efficiency CSA-µm ( x mm) column. For more demanding samples with disparate concentration ratios (up to :), use the CSA -mm and -mm columns ( min run time). Excellent fourfold increase in mass sensitivity with the -mm i.d. microbore format; fourfold decrease in eluent consumption compared to -mm columns. Simplified operation provided by the EG Eluent Generator, which requires only a deionized water source to produce MSA eluent.

Versatile Cation-Exchange Separations The IonPac CSA (-mm and -mm) cation-exchange columns provide fast, isocratic separation of lithium, sodium, ammonium, potassium, magnesium, and calcium in less than min using a dilute MSA or sulfuric acid eluent. Outstanding selectivity and efficiency allow manganese and many aliphatic amines to be resolved from the alkali and alkaline earth metals with simple acid eluents. Solvent is used as an eluent additive to reduce retention time and improve peak efficiency of hydrophobic amines; it enhances sample solubility IonPac CGA, CSA, mm Eluent: mn Methanesulfonic acid Eluent Source: EG Flow Rate:. ml/min Inj. Volume: µl Detection: Suppressed conductivity, CSRS -ULTRA mm, AutoSuppression recycle mode Peaks:. Lithium. mg/l (ppm). Sodium.. Ammonium.. Potassium.. Magnesium.. Calcium. Figure. The IonPac CSA column is used with the EG Eluent Generator for the separation of the common cations. Only a deionized water source is required. Eluent and regenerant preparation with corrosive chemicals are completely eliminated. IonPac CSA-µm, mm (no guard) Eluent: mn Methanesulfonic acid Flow rate:. ml/min Temperature: C Inj. Volume: µl Detection: Suppressed conductivity, CSRS-ULTRA mm, AutoSuppression recycle mode Peaks:. Lithium. mg/l (ppm). Sodium.. Ammonium.. Potassium.. Magnesium.. Calcium. 9 Figure. Fast isocratic separation of the common inorganic cations in four minutes using a mn methanesulfonic acid eluent. IonPac CSA, mm (no guard) Eluent: mn Methanesulfonic acid Flow Rate:. ml/min Inj. Volume: µl Detection: Suppressed conductivity, CSRS-ULTRA mm, AutoSuppression recycle mode Peaks:. Lithium. mg/l (ppm). Sodium. 7. Ammonium.. Potassium.. Diethylamine.. Magnesium. 7. Manganese.. Calcium. 9 9- and allows easy column clean-up after the analysis of complex matrices. The column can be operated at elevated temperatures to improve peak efficiencies and in some cases to modify column selectivity. Typical applications include the determination of inorganic cations and amines in drinking water, wastewater, power plant waters, soil extracts, acid digests, chemical additives, chemical process solutions, scrubber solutions, plating baths, and solvents. Isocratic Analysis of Alkali and Alkaline Earth Metals Common mono- and divalent cations can be separated isocratically by the IonPac CSA -mm column in less than minutes as illustrated in Figure. Operation is even easier when MSA is generated using the EG Eluent Generator. Fast Separation of Alkali and Alkaline Earth Metals The high-efficiency CSA-µm ( x mm) column is designed specifically for the fast analysis of mono- and divalent cations and ammonium present at similar concentrations. The CSA-µm mm column uses the same carboxylate and phosphonate functional groups as the mm and -mm CSA columns, but differs in column format and resin particle size. As a result, the CSA-µm -mm column provides the advantages of faster analysis time for inorganic cations and ammonium, reduced eluent consumption, and increased sensitivity. Figure illustrates the fast, isocratic separation of the common inorganic cations and ammonium in minutes using a mn methanesulfonic acid eluent. The CSA-µm -mm column is recommended for trace cation analysis using a large-loop injection. For ultratrace analysis, the TCC-LP or the CGA -mm column is recommended as the preconcentration column. Figure. Isocratic determination of manganese in the presence of lithium, sodium, ammonium, potassium, diethylamine, magnesium, and calcium.

Determination of Manganese for Power Plant Corrosion Monitoring Manganese can be quantified in cooling waters using the IonPac CSA with an MSA eluent to enhance the resolution of manganese from magnesium and calcium as shown in Figure. Economical Operation The IonPac CSA improves monovalent cation separations and reduces operating costs by eliminating the need for diaminopropionic acid monohydrochloride (DAP HCl) in the eluent to elute divalent cations. Dilute sulfuric acid can be used as an economical eluent. For added economy, this eluent can be used with the Auto-Suppression recycle mode of the CSRS Cation Self-Regenerating Suppressor or the CAES Cation Atlas Electrolytic Suppressor. MSA is recommended as the eluent for separations involving divalent cations such as barium, strontium, and manganese as shown in Figures and. Also, the CSA-µm ( x mm) and CSA ( x mm) are operated at lower flow rates, which provides the added benefit of reduced eluent consumption. Unique Carboxylate Cation Exchanger The IonPac CSA column is a unique hydrophilic, carboxylate/phosphonate-functionalized cation exchanger that provides excellent peak efficiency and peak shape for alkali and alkaline earth metals and amines. The IonPac CSA mm and mm packing is an -µm diameter macroporous particle and the CSA-µm -mm column substrate is a -µm diameter macroporous particle; both consist of ethylvinylbenzene crosslinked with % divinylbenzene. The substrate is functionalized with a mixed hydrophilic carboxylic acid/phosphonic acid layer that permits the elution of mono- and divalent cations using a dilute hydronium ion eluent, such as sulfuric acid or MSA. Prior to conductivity detection, the sulfuric acid or MSA eluent conductance is suppressed with a CAES or a CSRS using the AutoSuppression IonPac CGA, CSA-µm, mm Eluent: mn Methanesulfonic acid Flow Rate:. ml/min Inj. Volume: µl Temperature: C Detection: Suppressed conductivity, CSRS-ULTRA 9 mm, AutoSuppression recycle mode Peaks:. Lithium. mg/l (ppm). Sodium. 7. Ammonium.. Potassium.. Rubidium.. Cesium. 7. Magnesium.. Calcium. 9. Strontium.. Barium. Figure. Separation of the extended Group I and Group II inorganic cations. IonPac CSA (no guard), mm Eluent: Step change at min from mn to mn Methanesulfonic acid Flow Rate:. ml/min Inj. Volume: µl Detection: Suppressed conductivity, CSRS-ULTRA mm, AutoSuppression recycle mode Peaks:. Lithium. mg/l (ppm). Sodium.. Ammonium.. Potassium.. Magnesium.. Calcium. Figure. Trace-level quantification of ammonium in brine (: ratio) is fast and easy using the IonPac CSA coupled with cation AutoSuppression. electrolytic mode. Hydrochloric acid also can be used as an eluent with equivalent chromatography; however, the CSRS must be in the chemical suppression mode with tetrabutylammonium hydroxide as the chemical regenerant. High Loading Capacity The IonPac CSA column achieves baseline resolution of Group I and II cations, even for samples high in ionic strength. The column is compatible with acidic eluents and samples. Column performance does not deteriorate with the injection of acidic samples up to approximately mm in hydronium ion for the -mm and -mm columns. Thus acid-digested or acid-preserved samples can be injected 9 without ph adjustment. Peaks from a sample containing mg/l of sodium and. mg/l of ammonium are easily resolved as illustrated in Figure. The CSA-µm -mm column has approximately one-third the column cation-exchange capacity as the CSA -mm and therefore is not as tolerable with respect to sample ph. The CSA- µm -mm can withstand up to mm in hydronium ion with a µl sample volume. Smaller sample volumes can be used with the CSA-µm in this case. Another way is using the OnGuard II A pretreatment cartridge to pretreat the sample, enabling the CSA-µm -mm to analyze for samples with up to mm in hydronium ion.

Solvent-Compatible Packing Since the IonPac CSA column is % HPLC solvent-compatible, acetonitrile can be used to modify column selectivity to facilitate elution of hydrophobic amines, for efficient column clean-up, or to enhance sample solubility. This feature allows complex matrices to be analyzed with minimal sample preparation and extends the utility of the column to new applications requiring solvents as shown in Figures and 7. Solvent and Temperature Increase Flexibility for Methods Development The solvent compatibility of the IonPac CSA permits the use of acetonitrile in the eluent to modify ionexchange selectivity. Simultaneous sulfuric acid concentration gradients and organic solvent gradients can be used to achieve optimum resolution of closely eluting analyte pairs. The retention of hydrophobic analytes is decreased significantly by the addition of solvent. Operation at elevated temperatures is useful in improving peak efficiencies and asymmetry and for resolving closely eluting pairs. Figures and 7 illustrate the use of solvent in the eluent together with elevated temperature to optimize the separation of several closely eluting amines. IonPac CSA (no guard), mm Eluent: mn Sulfuric acid / % Acetonitrile to mn Sulfuric acid / % Acetonitrile in min, to mn Sulfuric acid / % Acetonitrile in min Flow Rate:. ml/min Inj. Volume: µl 9 Detection: Suppressed conductivity, CSRS-ULTRA mm, Chemical Suppression mode Temperature: C Peaks:. Lithium. mg/l (ppm). Sodium.. Ammonium.. Potassium. 7. Magnesium.. Calcium. 7.,-Propanediamine..,-Hexanediamine. 9.,7-Heptanediamine..,-Octanediamine..,9-Nonanediamine..,-Decanediamine..,-Dodecanediamine. 9 Figure. A sulfuric acid gradient coupled with an acetonitrile gradient and elevated temperature are used to optimize the separation of a wide range of amines and the alkali and alkaline earth metals. Eluent: IonPac CGA, CSA, mm Step gradient at min from. mn MSA /.% Acetonitrile to. mn MSA / % Acetonitrile; step gradient at min to. mn MSA / % Acetonitrile; gradient from to min to 9. mn MSA /.% Acetonitrile 7 Flow Rate:. ml/min Inj. Volume: µl Detection: Suppressed conductivity, CSRS-ULTRA mm, AutoSuppression external water mode Temperature: C Peaks:. Lithium. mg/l (ppm). Sodium.. Ammonium.. Potassium.. -Amino--pentanol.. Morpholine. 7. -Diethylaminoethanol.. Magnesium. 9. Calcium.. Cyclohexylamine.. -Dimethylaminopropylamine. 9 Figure 7. The IonPac CSA, with an MSA/acetonitrile gradient, separates Group I and II cations, ammonium, and amines in cooling waters.

Trace Analysis Is Easier with the EG Eluent Generator and Direct Large Loop Injection on a CSA-µm Combining the IonPac CSA- µm -mm column with the EG Eluent Generator makes trace cation analysis even easier. The EG Eluent Generator produces methanesulfonic acid eluents electrolytically, eliminating the need for eluent preparation. Only a source of deionized water is needed. The use of this ultrapure MSA as an eluent results in a low, stable baseline. Routine ppb-level analysis of inorganic cations and ammonium by direct injection is possible with the CSA-µm -mm column and a -µl injection loop, as illustrated in Figure. The large-loop direct-injection technique allows detection of cations to mid-ppt concentrations. Trace Cations Using Preconcentration The preconcentration technique is used when measuring ions in the low ng/l (ppt) levels. With this technique, the injection loop is replaced by either a guard or preconcentration column containing ion-exchange material similar to that used in the analytical column. This column concentrates ions from measured volumes of pure water, lowering detection limits by several orders of magnitude. Preconcentration is often used with online process IC instruments to obtain the lowest detection limits possible. In Figure 9, a -ml sample was concentrated on a -mm CGA guard column, followed by separation of the trace cations on a -mm IonPac CSA. Sample preconcentration can also be used to determine lithium as an additive tracer in industrial process waters. In Figure, 7. ml of a hydrazinetreated sample was concentrated on a CGA guard column, permitting the determination of lithium at sub-ppb concentrations. Calcium and Magnesium in Brine A MetPac CC- concentrator column, which selectively retains calcium and magnesium but has a low affinity for sodium, is used to. Figure. Trace cations determined by large-loop direct injection.. IonPac CSA-µm, mm (no guard) Eluent: mn Sulfuric acid Flow Rate:. ml/min Inj. Volume: µl Detection: Suppressed conductivity, CSRS-ULTRA -mm, AutoSuppression recycle mode Peaks:. Lithium. µg/l (ppb). Sodium.. Ammonium.. Potassium.. Magnesium.9. Calcium.99 Concentrator Eluent: Flow Rate: Detection: Inj. Volume: IonPac CGA, CSA, mm IonPac CGA mn Sulfuric acid. ml/min Suppressed conductivity, CSRS-ULTRA mm, AutoSuppression external water mode ml, preconcentrated Peaks:. Sodium < ng/l (ppt). Ammonium <. Trimethylamine ISO calibration data unavailable. Figure 9. Trace-level cations in ultrapure water using sample preconcentration. Figure. Trace lithium in a hydrazine sample matrix. concentrate calcium and magnesium from brines. The concentrated calcium and magnesium are then eluted from the concentrator column and separated on an IonPac CSA cation-exchange column. Amine Matrix Concentrator Eluent: Flow Rate: Inj. Volume: Detector: IonPac CGA, CSA, mm IonPac CGA mn Sulfuric acid step change to mn at min. ml/min 7. ml, preconcentrated Suppressed conductivity, CSRS-ULTRA mm, AutoSuppression external water mode Peaks:. Lithium. µg/l (ppb). Sodium. 9 9

CSA-MS ( x mm) Column for IC-MS The IonPac CSA-MS ( x mm) column is specifically designed to separate inorganic cations, polar hydrophilic amines, and other small organic molecules (such as theophylline, caffeine, and uracil) prior to detection with MS. The CSA-MS ( x mm) column format was specifically developed for MS operation. The CSA-MS ( x mm) column is ideally suited for fast elution and low flow rates required for interfacing with IC-MS detectors. Typically, the CSA-MS column will be operated in an ion chromatography system containing a post column cation eluent suppressor for removal of salt counter anions, followed by a conductivity detector and an ESI-MS detector in series as illustrated in Figure. A ground union is installed between the conductivity cell and the chassis to eliminate voltage buildup between the two detectors. Advantages of Using a Cation Suppressor with IC-MS The use of a suppressor in IC-MS provides several advantages. Methods developed for conductivity detection can be used without modification. The counteranions are removed reducing MS maintenance. The electrospray signal is improved when the ionic load entering the interface is lowered, even in comparison to volatile eluent systems. Detection limits are improved due to better signal stability and the elimination of ionization suppression. The availability of a high sensitivity conductivity trace provides information in addition to the MS detector. Extended Application Capabilities with the CSA-MS Column Figure shows an overlay of single ion traces of the M+H signals for small amines with a large sensitivity difference among the amines. The triethanolamine forms hydrogen bonds easily inhibiting the electrospray pro- Figure. IC-ES-MS System Schematic. Figure. Determination of alkylamines and alkanolamines using IC-MS detection. Suppressor: Gradient Conditions: Pump Injection valve +Electrospray -MS Conductivity,, Na+, Column external waste waste Suppressor Min IonPac CSA-MS, x mm CSRS-ULTRA -mm, external water mode, ma % ACN/7 mm MSA to % ACN/ mm MSA in mins, hold for min.. ml/min Conductivity/AQA MS Flow rate: Detection: MS Conditions: +ESI, Full Scan 7-7 amu, C, V Sample: mg Biaxin/ mls % ACN, sonicated and filtered Peaks:. Sodium, Na +.ACN. m/z. Potassium, K +.ACN. m/z +ESI-MS Cond Conductivity Detector Optional pump (addition of solvent/acid base) Grounded Union MSQ MS Figure. Separation of inorganic cations in a biaxin extract using MS detection. 9- IonPac CSA-MS, x mm Suppressor: CSRS-ULTRA -mm, external water mode, ma Gradient: -% ACN, - mm MSA in min Flow rate:. ml/min Injection loop: µl Detection: Conductivity/AQA MS MS Conditions: +ESI, V, C, SIM as indicated Peaks: m/z µg/l. Ethanolamine. Diethanolamine. Triethanolamine,. Trimethylamine,. Ethyldimethylamine 7. Triethylamine intensity intensity.. 7 7 amu. Peak 9.. Peak 7.. 7 7 amu 7-7-

cess, thus leading to poor sensitivity. In contrast, trimethylamine is very volatile. The other amines have good sensitivity. This work was done with minimal separation of the amines using the fast CSA-MS ( x mm) column. Inorganic cations can easily be determined in a Biaxin Extract as shown in Figure. A methanesulfonic acid/ acetonitrile gradient was used to elute inorganic as well as organic amines for screening purposes. Sodium and potassium are easily detected under these conditions as clusters with acetonitrile and/or water. For example, the highest masses are clusters with 9 water molecules while the lower masses contain acetonitrile. Figure demonstrates the analysis of a guanidine stock with quantification of a sodium impurity in guanidine. Using optimized conditions with low solvent, sodium and guanidine can quickly be determined with excellent sensitivity. Figures and demonstrate the use of a dual gradient to resolve cations in complex sample matrices. Figure illustrates a general cation screening method for a generic cold medication. The sample was dissolved in water and filtered prior to injection. The overlays of four chromatograms show the conductivity and the electrospray MS traces along with the blank runs. The MS was operated in full scan mode and the mass shown here were extracted. The mass for the M+H and the M+H+ACN are shown. Figure shows the use of a dual gradient applied to an antiseptic swab sample. Masses of the various alkyl chain lengths were extracted from the full scan run, four of which are shown here. The conductivity trace did not indicate multiple peaks.. -, Counts, Counts Conductivity SIM m/z SIM m/z........... Min Eluent: Flow Rate: Suppressor: Detection: IonPac CSA-MS, x mm.% ACN/ mm MSA. ml/min CSRS-ULTRA -mm, external water mode, 9 ma Conductivity/AQA MS MS Conditions: +ESI, C, V, SIM as indicated Sample: Guanidine µg/ml Loop: µl Peaks: m/z. Sodium cluster. Guanidine (NH ) C=NH Figure. Determination of a sodium impurity in a guanidine stock solution using IC-MS detection. TIC TIC Blank Cond. Cond. Blank Min IonPac CSA-MS, x mm Gradient:.-% ACN/- mm MSA in min, hold min Flow Rate:.7 ml/min Detection: Conductivity/AQA MS MS Conditions: +ESI, 7 C, V, full scan 7- amu Figure. Inorganic cation screening of a generic cold medication using IC-MS detection. m/z m/z m/z m/z m/z Conductivity 9 Min Intensity Intensity Intensity.. 7. 7. Peak Sodium Peak Pseudoephedrine Peak Dextromethorphan. 7 amu 7-77- IonPac CSA-MS, x mm Suppressor: CSRS-ULTRA -mm, external water mode, ma Gradient: -% ACN, - mm MSA in min, hold min. Flow rate:.7 ml/min Injection loop: µl Detection: Conductivity/AQA MS MS Conditions: +ESI, V, 7 C, full scan Sample: Antiseptic swab,.% Benzalkonium chloride Sample preparation: swab/ ml water Peaks: m/z. Sodium,. Benzalkonium branched. Benzalkonium (C). Benzalkonium (C). Benzalkonium (C) 7- Figure. Determination of benzalkonium chlorides in an antiseptic swab sample using IC-MS detection.

O r d e r i n g I n f o r m at i o n In the U.S., call ---9 or contact the Dionex regional office nearest you. Outside the U.S., order through your local Dionex office or distributor. Refer to the following part numbers. The IonPac CSA column can be used with either the CSRS Cation Self-Regenerating Suppressor or the Cation Atlas Electrolytic Suppressor. When performing concentrator work, the TCC-LP Cation Concentrator column or the IonPac CGA should be used as the concentrator column. When performing gradient cation exchange applications on the IonPac CSA, a Cation Trap Column (CTC) should be installed between the gradient pump and the injection valve to remove cationic contaminants from the eluent. Description Part Number IonPac CSA Columns IonPac CSA-µm Analytical Column ( x mm)...7 IonPac CGA-µm Guard Column ( x mm)...7 IonPac CSA-µm Analytical Column ( x mm)...7 IonPac CGA-µm Guard Column ( x mm)...7 IonPac CSA-µm Analytical Column ( x mm)...7 IonPac CGA-µm Guard Column ( x mm)...7 IonPac CSA-MS Analytical Column ( x mm)...99 SPECIFICATIONS Dimensions: Analytical x mm, x mm, x mm, and x mm Guard x mm, x mm, and x mm Maximum Operating Pressure: 7 MPa ( psi) Mobile Phase Compatibility: Acidic eluents, % acetonitrile. Alcohols should be avoided. Substrate Characteristics: Bead Diameter: µm ( mm and mm) µm ( mm) Crosslinking (%DVB): % Ion-Exchange Groups: Grafted carboxylic acid and phosphonic acid Functional Group Characteristics: Medium hydrophilic Capacity (µeq/column): µeq ( x mm) 7 µeq ( x mm) 9 µeq ( x mm) µeq ( x mm) Column Construction: PEEK with - threaded ferrule-style end fittings. All components are nonmetallic. Concentrator Column TCC-LP Cation Concentrator Column ( x mm). For both -mm and -mm concentrator work using carboxylated columns; very low pressure allows manual syringe loading or autosampler loading...7 Trap Columns CTC- Cation Trap Column (9 x mm) For gradient operation of -mm columns...9 CTC- Cation Trap Column ( x mm) For gradient operation of -mm columns... CSRS, Self-Regenerating Suppressor, OnGuard, Auto-Suppression, and IonPac are registered trademarks and CAES, MetPac, and Atlas are trademark of Dionex Corporation. Printed on recycled and recyclable paper. Passion. Power. Productivity. Dionex Corporation Titan Way P.O. Box Sunnyvale, CA 9- () 77-7 north America U.S. (7) 9-7 Canada (9) -9 South America Brazil () 7 Europe Austria () Belgium () 9 Denmark () 9 9 France () 9 Germany (9) 99 Italy (9) 7 The Netherlands () 97 Switzerland () 99 U.K. and Ireland () 7 97 Asia Pacific Australia () 9 China () India (9) 7 Japan () Korea () Singapore () 9 9 LPN -9 PDF / Dionex Corporation