Prominence for Ion Analysis

Similar documents
C190-E105 Printed in Japan ATD

ION CHROMATOGRAPHY SYSTEM S 150

Anion Analysis of Ophthalmic Irrigation Solutions with the Shimadzu Prominence IC System Craig Young, PhD, Sr. Tech Support Specialist

Dionex IonPac AS28-Fast-4µm column

HPLC Praktikum Skript

Preparative Separation of Active Components from Natural Products using Low-pressure Gradient Preparative HPLC

Determination of Polymer Modifier in Asphalt

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Suppression in anion chromatography. More sensitive analysis of anions and organic acids

Cation Exchange HPLC Columns

Figure 1. Structures for Vitamin B2 and Vitamin B1.

columns IonPac SCS 1 Silica Cation Separator

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

RESOLUTION OENO 33/2004 DETERMINATION OF SHIKIMIC ACID IN WINE BY HPLC AND UV-DETECTION

Expanded capabilities in ammonium and amine detection

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC

A novel approach to the analysis of multivitamin by online supercritical fluid extraction/supercritical fluid chromatography

Cation Exchange HPLC Columns

Accurate and Reproducible Determination of Organic Halogens Using Combustion Ion Chromatography

Air Monitoring. Semi-continuous determination of ambient air quality

Determination of Adsorbable Organic Halogen in Wastewater

Inline sample preparation for the determination of anions in sodium hydroxide

Figure 1. Structures for Vitamin B2 and Vitamin B1.

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE

Transferring HPLC methods from the HP 1090 Series to the Agilent 1100 Series HPLC system

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Liquid Chromatography

columns IonPac AS17-C Anion Exchange Column

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Determination of trace anions in concentrated hydrofluoric acid

Varian Galaxie Chromatography Data System for Preparative HPLC

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

861 Advanced Compact IC

High Performance Liquid Chromatography

883 Basic IC plus. The smallest Metrohm ion chromatograph

for Acclaim Mixed-Mode HILIC-1 Column

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Data Pack. Ion Chromatography Methods. June 2009

Determination of Trace Cations in Power Plant Waters Containing Morpholine

columns IonPac AS18 Anion-Exchange Columns

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

anion-exchange column

High Performance Liquid Chromatography

HPLC Columns. HILICpak VT-50 2D MANUAL. Shodex HPLC Columns Europe, Middle East, Africa, Russia

4. Ion chromatography (IC) 4.1. Educational aims and objectives

ISO INTERNATIONAL STANDARD

Protein Sequencer PPSQ-31A / 33A C297-E055B

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Theory of Ion Chromatography

High Pressure/Performance Liquid Chromatography (HPLC)

Analysis - HPLC A.136. Primesep 5 µm columns B.136

881 Compact IC pro 882 Compact IC plus. Compact ion chromatography for intelligent, reliable and precise analysis

groups I and II cations, amines, divalent transition metals

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Chemistry Instrumental Analysis Lecture 31. Chem 4631

IonPac Trace Cation Concentrator

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

Thermo Scientific. Anion-Exchange Column

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

Properties of Compounds

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Open Column Chromatography, GC, TLC, and HPLC

Mechanisms of retention in HPLC

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

Overcoming Challenging Matrices in Ion Chromatography

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

Thermo Scientific Dionex eluent suppressors for ion chromatography

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Introduction to Pharmaceutical Chemical Analysis

Luminescence transitions. Fluorescence spectroscopy

Determination of Chloride, Fluoride, Bromide, Nitrate, Sulphate and Phosphate in Water Sample...

Nexera UC Unified Chromatography

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

Determination of Sulfate and Chloride in Ethanol by Ion Chromatography

Basic principles of HPLC

School of Chemistry UNIVERSITY OF KWAZULU-NATAL, WESTVILLE CAMPUS JUNE 2009 EXAMINATION CHEM340: INSTRUMENTAL ANALYSIS.

HYPHENATED TECHNOLOGY GUIDE

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

2501 High Performance Liquid Chromatography

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

User Manual. IonPac NS2 Columns Revision 02 October For Research Use Only. Not for use in diagnostic procedures.

Chemistry 3200 High Performance Liquid Chromatography: Quantitative Determination of Headache Tablets

Acclaim Mixed-Mode WCX-1

Combustion Ion Chromatography. Fast and reliable determination of halogens and sulfur

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection

Transcription:

C9-E0 Prominence for Shimadzu High-Performance Liquid for

HPLC Quality In 98*, Shimadzu developed its first ion chromatograph. Since that time, interest in ion chromatography has risen in accordance with increasing environmental regulations. Concurrently, Shimadzu has been accumulating vast amounts of ion analysis research and data, and has grown to become a world-leading ion chromatograph manufacturer, developing both suppressor* and non-suppressor* systems. From the standpoint of detection theory, the decision to recommend the suppressor type as a standard instrument for anion analysis and the non-suppressor type as a standard instrument for cation analysis could only be made by Shimadzu, with our exhaustive knowledge of the features of both types. Organic Acid s Non-

Na + Mg + K + Total Support for When using ion chromatographs for the measurement of regulated compounds, instrument performance and analysis conditions must be suited to the respective objectives. In recent years, a wide assortment of detection methods has been adopted. In addition to electrical conductivity detection methods, there are combinations of UV absorption detection and post-column derivatization. Accordingly, a degree of perfection is now required of systems, including the basic performance of the detector units, as well as optimization of the reaction parts. In addition, methods for detecting ions* are certainly not limited to ion chromatography. It is also important to look carefully at analysis methods suited to a range of samples. As a leading manufacturer of a diverse range of analytical instruments, Shimadzu has introduced not only ion chromatographs, the basis of which is the well-received Prominence series high-performance liquid chromatograph, but also general-purpose instrumental analysis methods* for inorganic ions. These include atomic absorption (AA), inductively coupled plasma (ICP) emission analysis, and mass spectrometry. Ca + + NH Environmentalntal Field Tap water Drain water River water Factory drainage Soil water Pharmaceutical and Food Fields General Research Development Quality control F - Cl - NO - SO - Non-suppressor-type ion chromatograph exchange columns are used for separation, replacing high-performance liquid chromatography detectors with conductivity detectors suited to ion detection. instrument performance is demanded. This includes using high-performance solvent delivery pumps that reduce pressure fluctuations to a minimum during mobile phase solvent delivery. Commercialized in 98 Definitions in JIS K0 Shimadzu's ion chromatography analysis systems were first introduced in LC Talk, Vol. (Japanese, published in 98). Inorganic anions and cations in aqueous solution, and some organic acids and amines, are proscribed in JIS K0 General rules for ion chromatographic analysis. -type ion chromatograph analysis method alternatives This refers to an ion chromatograph that changes the mobile phase during detection to a low-conductivity composition, in order to detect trace ions in mobile phases consisting of highly concentrated electrolytes. This is particularly effective in anion analysis for amplifying the detected peaks by several times. When analyzing transition metal ions that are difficult to analyze directly with a conductivity detector, a post-column reaction system combined with a derivatization reagent may be selected. However, from the standpoint of sensitivity and selectivity, atomic absorption (AA) and inductively coupled plasma (ICP) analysis systems are often said to be effective. (See page : What Is the Optimal Elemental Method?)

Prominence for 0. What Is a /Non-Sup : Selecting a suppressor/non-suppressor system Anion for sensitivity Non-suppressor for diversity Non- Detection Sensitivity Degree of Freedom in Separation Conditions Mobile Phase Composition (acidic to alkaline) (alkaline) Additives Temperature Control Calibration Curve Running Costs Maintenance With non-suppressor and suppressor systems, the ph of the mobile phase is completely different (acidic versus alkaline). Naturally, the ion elution sequence is also affected. In anion analysis, the mobile phase composition and separation vary depending on whether or not a suppressor is used. In addition to the sensitivity required and the sample concentration, running costs are another issue when selecting a system. Bits of y Detection sensitivity Mobile phase composition Additives Generally calculated from the S/N ratio and standard deviation, this term is used in the concentration region in which noise affects the quantitative results. systems are effective for improving the quantitative accuracy in this concentration region, as they provide peak signal amplification. However, this amplification is only valid for anion analysis. Anion analysis The mobile phase in a suppressor system must be a basic solution, but with non-suppressor systems, a wide variety of solutions can be used, ranging from acidic to basic. With organic acids, the ion valence changes with the ph of the mobile phase, and this can dramatically affect the elution position. Reagents can be added to the mobile phase, with the objective of improving specific ion separation. With a non-suppressor system, the possibilities are endless, including crown compounds to improve the separation of Na and NH, and a variety of reagent additives to render the mobile phase composition similar to the sample matrix. Cation analysis Degree of freedom With non-suppressor systems, the acidic mobile phase alternatives are extensive, and in separation investigations As with HPLC, ion separation and detection take advantage of the target substance's characteristics. In non-suppressor systems, analytical conditions can be changed to suit the sample characteristics, as there are none of the limits on mobile phase when utilizing a suppressor. multiple acids can even be mixed to improve the separation. Furthermore, the separation arrangement is also extensive as a variety of additives can be used, including organic solvents. Temperature control With ion chromatographs from other companies, column and detector temperature control has largely been overlooked. Yet varying the temperature is an effective means of controlling elution time for substances with differing ion valences and hydrophobic regions. Since conductivity has a 0. %/ C temperature coefficient, heating performance can be said to be an important aspect of ion chromatography.

pressor? Cation Non-suppressor for collective strength Non- Detection Sensitivity Degree of Freedom in Separation Conditions Mobile Phase Composition (Multiple components can be mixed) Additives Temperature Control Calibration Curve Running Costs Maintenance Cation analysis suppressors are ineffective for peak amplification, and can only decrease the noise level. This decrease in noise can be compensated for by the hardware specifications. With cation analysis, ions can be separated with an acidic mobile phase in both suppressor and non-suppressor systems. However, non-suppressor systems are advantageous for separation investigations as they allow the mobile phase composition to be arranged in a variety of ways. What Is the Optimal Elemental Method? Calibration curve In ion chromatography, separation of components, including organic acids and amines (such as ammonium), is conditional on stable ionization. With non-suppressor systems, the calibration curve is linear, since detection occurs under the same mobile phase conditions as separation. In contrast, with suppressor systems, since the mobile phase is changed to a weak acid or water, and the ph changes in accordance with changes to the ion concentration in the sample, with organic acids and amines, the extent of ionization varies, producing a nonlinear calibration curve. (Refer to LC Talk, Vol., page.) Maintenance and running costs Maintenance is indispensable in order to maintain the performance of precision analytical instruments. In addition to parts to maintain hardware performance, consumables must also be considered. With non-suppressor systems, attention to suppressor parts is completely unnecessary, an advantage in terms of both maintenance and running costs. Some reagents utilized for the analysis of rare earth metals and transition metals via post-column reaction are toxic, and must be strictly controlled. by AA or ICP, which features a greater range of alternatives, is recommended for elements such as those in the following table. Al Si P S Fe Ni Cu Zn Ba Sr Ag Au Pd Cd Co Mn Hg 0ppt 0 00ppt 00 ppb 0ppb 0 00ppb 00 ICP mass spectrometry ICP emission spectrometry Furnace AA Flame AA * These are reference values to serve as a guide in comparing relative sensitivity. Quantification limits in actual analysis will differ with the sample matrix.

Prominence for 0. What Are the Component Fea Prominence: Their reliability and high performance systems, aiming for further sensitivity Non-suppressor systems, aiming to be simpler, with high sensitivity Point Point Point Point * compatible Point Point Point *Non-suppressor and suppressor compatible Bits of y Double temperature control and pulse-free solvent delivery Elemental technology required with non-suppressor systems The mobile phase conductivity is affected by temperature changes and solvent delivery pump pressure variations, which can lead to baseline noise and drift. With suppressors, noise is reduced by reducing mobile phase conductivity, the source of these problems. With non-suppressor systems, however, this problem must be dealt with by improving basic hardware performance. Shimadzu accomplishes this using its proprietary high basic performance. This includes pulse-free solvent delivery, which suppresses pressure variations during solvent delivery to a bare minimum, and double temperature control, featuring detector cells equipped with thermal control functionality arranged within the column oven. Forced air-circulation system This temperature control system controls the temperature using a fan installed at the back of the column to provide forced air circulation within the oven. This is ideal for high-accuracy thermal control of columns and detector cells arranged within the oven, as well as for post-column reaction parts. Cartridge type suppressor The Shimadzu suppressor is a proprietary cartridge type with electrodes at both ends. The suppressor regeneration system uses hydrogen ions generated through electrolysis of the eluate from the detector by the electrodes at both ends. Continuous analysis is possible by alternately replacing the cartridges.

tures? Point On-line degasser DGU-0A By adopting a high-performance online degassing system with an internal capacity of 00 µl, offline degassing of the mobile phase using ultrasonic waves or decompression is not required. Piping is straightforward, thanks to the special reservoir tray. Point Point controller CBM-0A This high-function interface features built-in server functionality that communicates with LabSolutions, which has Prominence system control and data buffering functionality. Point Point Solvent delivery pump LC-0AD SP With the pulse-free solvent delivery pump, which is capable of solvent delivery at 00 nl/min to 0 ml/min, conductivity detection, which does not require suppressors, can be performed. Point Autosampler SIL-0Ai SIL-0A The SIL-0Ai is a standard ion chromatograph autosampler, compatible with both variable injection volume systems based on syringe measurements, and with loop measurement systems. The lineup also includes the SIL-0A, a total-volume injection system based on plunger pump measurement, which is capable of high-speed injection and high accuracy from 0. µl. (See photo at right.) Point Conductivity detector CDD-0A SP/VP SIL-0A Two-channel simultaneous detection is possible with the addition of the optional dual kit NS. It can accommodate a dual flow-line analysis system, equipped with anion suppressor/cation non-suppressor systems. Using the VP functionality, in addition to pass/fail determinations based on conductivity measurements, the system is capable of automatic calibrations, including zero conductivity correction and span adjustments. Point * compatible Absorbance detector SPD-0A Thermal control functionality is provided as standard in the removable detector cell assembly, reducing the impact of ambient temperature changes. Point Column oven CTO-0AC SP *Non-suppressor, and suppressor (including the HIC-0A Super** suppressor package) compatible The column oven features forced air-circulation, which has an established reputation for HPLC column temperature control. Furthermore, thanks to the electronic cooling function, column temperature can be controlled from an ambient temperature of C. In addition to columns, this large-capacity oven can simultaneously accommodate a suppressor/non-suppressor conductivity detector cell assembly. non-suppressor The non-suppressor detector cell assembly (in the red frame) has independent temperature control functionality, as well as a double temperature control design based on installation inside the CTO-0A/ 0AC, thereby achieving even stricter temperature control. * Dual kit NS: Set of CDD-0A internal expansion board and detector cell assembly Non-suppressor detector assembly detector assembly suppressor The suppressor detector assembly (in the blue frame) consists of a detector cell assembly with temperature control functionality (top) and a suppressor (bottom). Equipped with Shimadzu's proprietary electrochemical regeneration system, this cartridge type suppressor system does not require a regenerant. * HIC-0A Super suppressor package: The basic configuration consists of the CTO-0AC and CDD-0A. The valves and boards required for the suppressor system are incorporated into the unit.

Prominence for 0. What Are the Variatio /SP: Combinations to suit your application Single Flow-Line Switchable In this single flow-line analysis system, either the suppressor system or non-suppressor system detector is selected and switched over for use. Non- Organic Acid Features The CDD-0ASP/VP is compatible with channel detectors. system anion analysis and non-suppressor system cation analysis can be used as appropriate with simple piping connection switching. In addition, in wastewater analysis where contamination of the suppressor is a concern, anion analysis can be performed using the non-suppressor system. Solvent delivery pump Autosampler column Conductivity detector cell column The connections for this part can be switched over. CDD unit Dual kit NS detector (option) The suppressor or non-suppressor detector is attached. Mobile phase Flow-Line Diagram for the Single Flow-Line Switchable The photo shows a suppressor/non-suppressor system combination. The suppressor system detector has been installed in the suppressor package's column oven. With the non-suppressor system, detectors with the same shape as shown in the photo at left (red frame) are arranged to the left and right. Bits of y CDD-0A conductivity detector with a -channel detector configuration With the base CDD-0A unit, select from the suppressor (SP) or non-suppressor (NS) system. (Base system) Adding the optional dual kit NS (non-suppressor system) in the main unit adds non-suppressor Base Combination Combination Non-suppressor (NS) system detector functionality. The result is a -channel detector equipped with detector cell units. Additional Option (dual kit NS) Non-suppressor Non-suppressor 8

ns? Dual Flow-Line This is a simultaneous analysis system in which each of the analysis flow lines is equipped with a conductivity detector. Features With automatic switching of the sample injection valves, a sample loop with flow lines is consolidated into one. Simultaneous analysis is performed by adding sample to the sample loops with a single sample injection. This system is ideal for routine analysis of anions and cations as in tap water quality analysis. A UV detector can also be used when the anion suppressor system is used. Organic Acid Non- Solvent delivery pump Autosampler column column UV detector Conductivity detector cell Mobile phase CDD unit Mobile phase Flow-Line Diagram for the Dual Flow-Line Combustion y This system is used to confirm the absence of halogen in electrical equipment and electronic components, and to measure sulfur compounds in chemical materials. Plastics, electronic materials and other solid samples are incinerated. The gases generated by incineration are captured by an absorbing liquid, which is then analyzed by an ion chromatograph for fluoride, chloride, and other halogens, and for sulfur and other ions. Incineration (Purchase incineration equipment separately.) F, Cl, Br, S and other chemicals are gasified Online connection Heated to approx.,000 C Captured by an absorbing liquid Shimadzu Prominence /NS 9

Prominence for 0. The Fami Post-Column Reaction : development based on a thorough This post-column reaction system utilizes the pyridinecarboxylic acid - pyrazolone method for analysis by shape of cyanogen chloride and cyanide ions, standards for water quality testing. In this system, attention is paid to thermal recycling generated by reactions at 00 C for st stage reactions. by reusing the heat Organic Acid Flow-Line Diagram for the Solvent delivery pump Injector Column oven with cooling functionality column Reaction coil Thermal recycling Cooling coil Absorbance detector CN CNCI 00 µl injection volume Mobile phase Reaction solution Solvent delivery pump Solvent delivery pump Reaction solution Reaction coil Chemical reaction chamber Data processor Waste liquid Non- This post-column reaction system utilizes the bromate ion method for the analysis of bromic acid, a standard for water quality testing. Special piping is adopted for its mixing effectiveness to ensure that the highly concentrated and viscous reaction solutions are mixed. Flow-Line Diagram for the Organic Acid Solvent delivery pump Autosampler Column oven column Reaction coil Absorbance detector Br 0.00mg/L 00 µl injection volume Mobile phase Reaction solution Solvent delivery pump Reaction solution Solvent delivery pump Data processor Waste liquid Non- Bits of y The column oven for cyanic analysis is equipped with cooling functionality In cyanic analysis, while the liquid temperature reaches 00 C during part of the reaction, this high-temperature reaction solution is generally introduced directly into the detector cell. To reuse this heat, the Shimadzu design returns a portion to the column over, which is equipped with cooling functionality, where it is reused for st stage reaction heating control (thermal recycling). In this way, it is possible to lessen the heat burden on the detector cell, enabling more stable analysis. Post-column system heating control In the post-column, the reaction solution mixes with eluate from the column and undergoes a chemical reaction. It is therefore very important to accurately control the temperature and time required for this reaction. After the reaction solution is mixed, if the liquid temperature does not quickly rise to the reaction temperature, the reaction will be insufficient. With post-column reactions, this is an important aspect of reaction system design. 0

ly knowledge of chemical reactions Switchable and Two types of analysis are possible by switching the flow-line connections. Organic Acid Non- Special cyanic analysis piping Special bromate analysis piping Detection wavelength 8 nm Specialty of the Shimadzu Post-Column Reaction solution Mobile phase Reaction solution UV Spectrum ( ) for Each Solution A high-efficiency reaction is a key feature of post-column systems. For this reason, reaction solution mixing and temperature control are extremely important. In producing the Shimadzu cyanic/bromate analysis system, each of the special piping parts was designed separately to optimize the reaction system (Japanese Patent #0809). To ensure high-accuracy thermal reaction control, Shimadzu adopted a chemical reaction chamber (CRB-A) and column oven (CTO-0A/9AC) featuring a forced air-circulation system that enjoys an established reputation in HPLC. Organic Acid With the UV detector, it is possible to selectively analyze organic acids, which are easily affected by impurities, with a high degree of sensitivity, using Shimadzu's proprietary post-column ph buffering method. This is a unique method in which organic acid ionization is suppressed under acidic mobile phase conditions. After separation in an ion exclusion column, ionization of each organic acid is promoted online, resulting in high-sensitivity conductivity detection. Organic Acid us/cm Solvent delivery pump Autosampler Column oven Post-column reaction part column Conductivity detector Peaks. -Ketoglutaric acid. Citric acid. Pyruvic acid. Malic acid. Succinic acid. Lactic acid Mobile phase Reaction solution Solvent delivery pump Data processor Waste liquid Flow-Line Diagram for the Organic Acid 8. Formic acid 8. Acetic acid 9 9. Levulinic acid 0 0. Pyroglutamic acid Non-

Prominence for 0. Making s High-Performance Workstation: LabSolutions for ion analysis LabSolutions y Workstation Control with a High Functionality Launcher This software efficiently manages the operation of the Prominence HIC system, which can accommodate various analyses through changes to the instrument configuration. The launcher can be customized by combining an image of the laboratory, created with graphics software, with instrument icons arranged in your preferred layout. The icons can be freely arranged, and the background can be changed. Create Customized Calibration Curves with Multi-Functional Compound Tables With ion chromatographs, there is considerable variation in the concentration range for the calibration curves required for each compound, from low concentration to high concentration. Are you frustrated that calibration curves are so difficult to make? With compound tables, it is possible to specify with pinpoint accuracy the concentration to use in making calibration curves. In addition, approximate expressions, whether or not to pass through the origin, and other settings can be freely configured for each component, optimizing the creation of calibration curves. Detailed calibration curve settings for each component Pinpoint specification of concentration data The data used can be individually selected

Easier to Use Powerful Peak Integration That Only the LC Workstation Can Provide If the peaks of adjoining components are not separated, or if there are overlapping peaks from impurities, conventional peak integration is sometimes not enough. In such cases, peaks can be detected as you please with a mouse click, using the HPLC design manipulation function. Furthermore, this function can be adapted to separate chromatograms on an individual basis. Using the Grouping Function, Total Hardness and Total Concentration Can Be Calculated The grouping process includes a function for obtaining a simple summation of the quantitative results for multiple peaks. Using this function, it is possible to obtain a total cyanic concentration, which is necessary for water quality analysis. Furthermore, in combination with the compound table's standard concentration correction coefficient function, it is possible to calculate the total hardness from the Mg and Ca concentrations. PDF Output Is Included as Standard To accommodate paperless offices, PDF output functionality is included as standard. By enabling the PDF report output settings, reports can be created automatically when analysis is completed. An image of the results can even be checked via LAN on PCs not equipped with LabSolutions.

Prominence for 0. What Is the Configur Configuration Example: These are examples of basic configurations. Basic / Single flow-line analysis system No. P/N 8-0- 8-09- Description controller Solvent delivery unit Model CBM-0A LC-0ADSP Quantity 8-08- On-line degasser DGU-0A 8-0-9 8-0-9 8-0-9 8--9 Reservoir tray Autosampler Sample rack L ml PP vial SIL-0Ai Non- 8 8-090-9 package HIC-0A Super 9 0 8-00- 8-0- 8-00- 8-090-9 Column oven Conductivity detector UV-VIS detector cartridge for anions CTO-0AC CDD-0AVP SPD-0A 8--9 Preheating coil kit LC workstation PC set LabSolutions LC Single Flow-Line / Variations Single flow-line switchable analysis system/dual flow-line analysis system No. P/N 8-0- 8-09- 8-08- Description controller Solvent delivery unit On-line degasser Model CBM-0A LC-0ADSP DGU-0A Quantity Switchable Flowrate Dual Flow-Line 8-0-9 Reservoir tray 8 8-0-9 8-0-9 8--9 8-090-9 Autosampler Sample rack L ml PP vial package SIL-0Ai HIC-0A Super Non- 9 8-00- UV-VIS detector SPD-0A 0 8-0-9 8-0-9 8-0-9 8-090-9 High-pressure flow-line selection valve Connection-parts kit for dual flow line Dual kit NS cartridge for anions FCV-AH 8--9 Preheating coil kit LC workstation PC set LabSolutions LC Dual Flow-Line / (for Water Quality ) No. P/N Description Model Quantity Bromic Acid Cyanogen Switching 8-0- 8-000- 8-089-9 controller Solvent delivery unit Solvent delivery unit CBM-0A LC-0AD LC-0Ai 8--9 0AD automatic rinsing kit 8-09- On-line degasser DGU-0A 8 8-0-9 8-0-9 8--8 Reservoir tray Autosampler Sample loop 00 µl PEEK SIL-0Ai 9 8-0-9 Sample cooler L 0 8-00- 8-00- 8-00- 8-8-9 8-0-9 8--9 8-0-9 Column oven UV-VIS detector UV-VIS detector Inert cell analysis piping kit analysis piping kit Chemical reaction chamber LC workstation PC set CTO-0AC SPD-0A SPD-0AV For SPD-0A/0AV CRB-A LabSolutions LC Non- Switchable and Injectors other than the SIL-0Ai can also be used. Contact your Shimadzu representative. With the dual flow-line analysis system, ml vials are required, as single injection volumes are large. In analysis with a minimum column temperature of 0 C, using the CTO-0A (8-009-XX) is not a problem. If the SIL-0AC (8-00-XX) is used, sample cooler L and sample loop 00 µl PEEK are not required. For system details, see. What Are the Variations? The degree of hydrophobicity will affect the amine elution position.

ation? (The system can be designed to meet your application.) Primary Column Lineup Analyte P/N Model Column Size Features 8--9 Shim-pack IC-A 00 mm L. x. mm I.D. This is an anion analysis column in which an alkaline mobile phase can be used. Anion 8-0-9 8-898-9 Shim-pack IC-A Shim-pack IC-SA 0 mm L. x. mm I.D. 0 mm L. x.0 mm I.D. This all-purpose anion analysis column achieves high separation with an acidic mobile phase. This all-purpose column is used in suppressor system anion analysis. 8-00-9 Shim-pack IC-SA 0 mm L. x.0 mm I.D. This is a high separation column used to analyze chloric acid. Columns Cation 8--9 8-9-9 8--9 Shim-pack IC-C Shim-pack IC-C Shim-pack IC-C 0 mm L. x.0 mm I.D. 00 mm L. x. mm I.D. 0 mm L. x. mm I.D. This is used for analysis of monovalent and bivalent ions under different mobile phase conditions. This is a cation analysis column. The hydrophobic value is moderate. This is an all-purpose column for cation analysis (low hydrophobic value). 8-0-9 Shim-pack IC-SC 0 mm L. x. mm I.D. This is a cation analysis column. The hydrophobic value is high. Bromic acid 8-88-9 Shim-pack IC- 0 mm L. x.0 mm I.D. This is a bromate analysis column. Cyanogen 8-88-9 Shim-pack Amino-Na 00 mm L. x.0 mm I.D. This is a cyanic analysis column. 8--9 Shim-pack IC-GA 0 mm L. x. mm I.D. This is the Shim-pack IC-A guard column. Anion 8-0-9 8-898-9 Shim-pack IC-GA Shim-pack IC-SA (G) 0 mm L. x. mm I.D. 0 mm L. x. mm I.D. This is the Shim-pack IC-A guard column. This is the Shim-pack IC-SA guard column. 8-00-9 Shim-pack IC-SA (G) 0 mm L. x. mm I.D. This is the Shim-pack IC-SA guard column. Guard Columns Cation 8-8-9 8--9 8-9900-9 Shim-pack IC-GC Shim-pack IC-GC (III) Shim-pack IC-GC 0 mm L. x.0 mm I.D. 8 mm L. x.0 mm I.D. 8 mm L. x.0 mm I.D. This is the Shim-pack IC-C guard column. This is the Shim-pack IC-C guard column. This is for the Shim-pack IC-C. (There is also a replacement cartridge.) 8-0-9 Shim-pack IC-SC (G) 0 mm L. x. mm I.D. This is the Shim-pack IC-SC guard column. Bromic acid 8-88-9 Shim-pack IC- (G) 0 mm L. x. mm I.D. This is the Shim-pack IC- guard column. Cyanogen 8-88-9 Shim-pack CN (G) 0 mm L. x.0 mm I.D. This is the Shim-pack IC-Amino-Na guard column for cyanic analysis. Pre-Columns Cation 8--9 Shim-pack IC-PC 0 mm L. x 8.0 mm I.D. This pre-column is used for monovalent cation analysis with the Shim-pack IC-C. Anion Cartridges P/N 8-0-9 Description cartridge for anions Standard Solution Chromatograms Peaks. PO. F. Cl. NO. Br. NO. SO Peaks. Li. Na. NH. K. Mg. Ca Anion with the Shim-pack IC-A Cation with the Shim-pack IC-C C Peaks. F. Cl. NO. Br. NO. PO. SO Peaks. F. ClO. BrO. Cl. NO. Br. ClO 8. NO 9. PO 0. SO 8 9 0 Anion with the Shim-pack IC-SA Anion with the Shim-pack IC-SA

Sample Filters for Measurements Disposable Filters for y Product Name Specifications Pore Size (µm) Diameter (mm) Quantity P/N Filter AI 0. 00 0-0- Filter AI 0. 00 0-0- Filter AI 0. 00 0-0- Acrodisc 0. 00 8T* Acrodisc 0. 0 8T* *Product handled by Shimadzu GLC Ltd. Sample Pretreatment Cartridges for y Maxi-Clean SPE Solid Phase Extraction Cartridge for y Resin Type Features P/N* 0. ml capacity: 0 included (Capacity: 0. ml,. ml). ml capacity: included IC-RP Removes hydrophobic surfactants and organic substances. 00 0 IC-OH Removes high-concentration anionic components with OH radicals. It is sometimes used to increase the ph of acidic samples. 0 0 IC-H Removes high-concentration cationic components with H radicals. It is sometimes used to decrease the ph of basic samples. 0 IC-Ag This removes high-concentration halogenated ions using the tendency for halogenated ions to bind with silver ions and then precipitate. 0 08 IC-Ba This removes high-concentration sulfuric acid ions using the tendency for sulfate ions to bind with barium ions and then precipitate. 08 0 IC-Chelate This removes bivalent cations and transition metals using the tendency for complexation with a Na-type imino acetate (chelate) stationary phase. 00 0 *Product handled by Shimadzu GLC Ltd. Other than these, there are special manifold types and a variety of adaptors. Printed in Japan 9-009-0A-NS