Measurement of Acrylonitrile, Acetonitrile and Nitromethane in Ambient Air and Vehicle Exhaust by Gas Chromatography with Thermionic Specific Detector

Similar documents
NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

Identification of Hydrocarbons in Ambient Air

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

GAS CHROMATOGRAPHY (GC)

STANDARD OPERATING PROCEDURES

U.S. EPA Method 8270 for multicomponent analyte determination

Unlocking Retention Times in Gas Chromatography

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

Fast Determination of Impurities in Propane- Propylene Streams Using a Pulsed Flame Photometric Detector (PFPD) and a New Capillary.

TO-15 Checklist Determination of VOCs in Air by GC-MS

Evaluation of a New Analytical Trap for Gasoline Range Organics Analysis

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer

The Application of Method TO-15 to Naphthalene Measurements in Indoor Air

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

DET REPORT. 1.) CATALYTIC COMBUSTION IONIZATION DETECTION (CCID) - MORE CHARACTERISTICS OF THE SELECTIVITY FOR n PARAFFINS. NO.

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Application Note 116 Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column

Study of Residual Solvents in Various Matrices by Static Headspace

Chapter 3: Source Measurement Techniques

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Application Note 032

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Permanent Gas Analysis by Gas Chromatography Vacuum Ultraviolet Spectroscopy


ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

1.0 Reactive Gas Chromatography Design and Setup Procedure for Catalyst Pelletization & Inlet Packing Software and Method.

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System

Petrochemical. Transformer Oil Gas Analysis - TOGA

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Fast, Quantitative Analysis of Residual Solvents in Cannabis Concentrates

ANNE JUREK. Abstract: soils and are found. in can also with GC/MS. poster. in series. option for. There are problems. analytes. in methanol.

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

Monomer Analysis. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

CHAPTER 6 GAS CHROMATOGRAPHY

Evaluating Leaks in a Soil Gas Sample Train

Gas chromatography. Advantages of GC. Disadvantages of GC

Gas Chromatography (GC)

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

Real Time On-Site Odor and VOC Emission Measurements Using a znose

Application Note S/SL

Optimization of 1,4-Dioxane and Ethanol Detection Using USEPA Method 8260 Application Note

Skoog/Holler/Crouch Chapter 26 Principles of Instrumental Analysis, 6th ed. CHAPTER 26

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

Headspace Technology for GC and GC/MS: Features, benefits & applications

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS

Analysis of Sulfur-Containing Flavor Compounds By GC/MS With A PFPD

SELECTED ION FLOW TUBE MASS SPECTROMETRY. Interscience Expert Center: VIP Meeting 15 Sept. 2009

Using Hydrogen as An Alternative Carrier Gas for US EPA 8260

JWH-018 and JWH-022 as Combustion Products of AM2201

Unintended Consequences with Conversion to Hydrogen Carrier in Gas Chromatography

Volatile organic compounds (VOCs):

Chapter 31 Gas Chromatography. Carrier Gas System

High-Speed Gas and Headspace Analysis for the Process-Line and Laboratory: SIFT- MS IFPAC 2017

APPLICATION NOTE. A Capillary Approach to ASTM D3606: Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline

Fast Gas Chromatography using Heated Headspace Gas Auto Sampling Techniques: Ethylene Oxide and 1,4-Dioxane in Fatty Acids

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

costech instruments ECS 4010 Elemental Combustion System CHNS-O

Introduction to GC/MS

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

Optimization of Method Parameters for the Evaluation of USEPA Method Using a Purge and Trap with GC/MS

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Sub-ppt Atmospheric Measurements Using PTV-GC-FID and Real-Time Digital Signal Processing

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Chlorinated Compounds in Hydrocarbon Streams Using a Halogen Specific Detector (XSD)

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

Analytical Trap Comparison for USEPA Method 8260C

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

PA-DEP 3686, Rev. 1. Light Hydrocarbons in Aqueous Samples via Headspace and Gas Chromatography with Flame Ionization Detection (GC/FID)

LAMBTON SCIENTIFIC (A Division of Technical Chemical Services Inc.)

G a s C h r o m a t o g r a p h y Determination of Ethanol in Wine by Head-Space Gas Chromatography

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

Intertek Environmental VOC Emissions

Agilent G2350A Atomic Emission Detector (AED)

Application. Gas Chromatography February Introduction

Elemental Analysis: CHNS/O characterization of polymers and plastics

Muliple Gas#3 plus Sulfur GC Configuration

GC Instruments. GC Instruments - Sample Introduction

Volatile Organic Compounds in Every Day Food

Methanol Extraction of high level soil samples by USEPA Method 8260C

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

A Newly Approved ASTM Standard For Analysis of Thiophene in Benzene Using a Pulsed Flame Photometric Detector (PFPD)

Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector

Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70

AppNote 7/1994. Friedhelm Rogies, Andreas Hoffmann Gerstel GmbH & Co.KG, Aktienstrasse , D Mülheim an der Ruhr, Germany

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

TOUR OF SOIL CHEMISTRY LABS (09/22/07)

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

Transcription:

Measurement of Acrylonitrile, Acetonitrile and Nitromethane in Ambient Air and Vehicle Exhaust by Gas Chromatography with Thermionic Specific Detector Randall Bramston-Cook Lotus Consulting, 5781 Campo Walk, Long Beach, Ca 90803 310/569-0128 ebramstoncook@msn.com Presented at 2008 EPA/AWMA Symposium on Air Quality Measurement Methods and Technology, Chapel Hill, NC, November 5, 2008 Copyright 2008, Lotus Flower, Inc.

Measurement of Acrylonitrile, Acetonitrile and Nitromethane in Ambient Air and Vehicle Exhaust by Gas Chromatography with Thermionic Specific Detector Extended Abstract # 90 Randall Bramston-Cook Lotus Consulting, 5781 Campo Walk, Long Beach, Ca 90803 INTRODUCTION Nitrogen containing hydrocarbons are sometimes found as emissions from gasoline and diesel vehicle exhaust. 1 Generally, these compounds, if present, are very low in concentration, and require sophisticated analytical techniques to measure. The toxicity of organo-nitrogen compounds such as acetonitrile, acrylonitrile and nitromethane, is sufficient to cause concern, even at low concentrations. 2 With the evaluation of new vehicle technologies, such as diesel selective catalytic reduction (SCR) using urea, for example, the potential for emission of some nitrogen containing compounds may increase. This paper reports on the design of an instrument specifically dedicated to the measurement of very low levels of these nitrogen containing hydrocarbons. Trace levels of organic compounds in ambient air and vehicle exhaust conventionally are measured by gas chromatography with flame ionization 3,4 or mass spectrometric detectors. 5,6 Although both of these detectors are sensitive enough for most organics, this particular family of organo-nitrogen compounds is typically found at levels below usual detection limits of these techniques or are not specific enough to pick them out from the rest of the huge number of other organics. These three targets typically elute between n-pentane and n-hexane, along with a multitude of possible C5- and C6-olefins and the target analytes cannot be readily distinguished from them. The low molecular weight of these (MW 41, 53, 61) preclude their positive identification from other possible coelutors, especially hydrocarbons with common ions to these. The thermionic specific detector (TSD) is specifically designed to detect organo-nitrogen and organo-phosphorus compounds and exclude hydrocarbon response. 7 A rubidium-impregnated ceramic bead is mounted directly above a conventional flame tip and is heated to a red glow by applied current. The generated signal is then processed as other chromatographic detectors. The design of the Trace Nitrogen System is intended to provide for the analysis of gas phase samples collected in conjunction with particulate measurements and exhaust monitoring programs at various government testing laboratories. Initial criteria were the following: 1) capability to analyze for very low concentration samples, 2) provision for two different analysis channels that can treat the sample with independent sample loading, trapping and chromatography, 3) provision for two different detectors to give analytical confirmation and/or to establish peak identification, 4) provision for enhancements to the instrument design based on past experience with the analytical principles involved.

EXPERIMENTAL Acrylonitrile, acetonitrile and nitromethane are determined with a Varian 3800 Gas Chromatograph (Varian Inc., Walnut Creek, Ca) equipped with dual liquid-nitrogen concentrator traps, a thermionic specific detector with ceramic bead and a flame ionization detector. Instrument operating parameters are provided in Table I. All valves are Valco Series 1/16 WE type. These valves are equipped with micro-electric actuators controlled through timed events in the chromatograph. Two valve ovens, holding all valves, are maintained at 120 o C and 150 o C as appropriate for the valve location A sixteen position automated sampler (Valco Multiposition Valve CSD Type with heated sample lines) is included to allow unattended operations with multiple samples. All data is collected, processed and reported with the Varian Star Workstation, with full control of most operating parameters and the automated sampler, including all Varian 3800 operations. Valving system is designed and assembled by Lotus Consulting (Long Beach, Ca). Table 1. GC-TSD parameters for Trace Nitrogen System Column Oven Program Initial Temperature 10 o C for 6 min -100 o C/min to -20 o C, Ramp 1 hold for 8.7 min Ramp 2 5 o C/min to 80 o C 10 o C/min to 150 o C, Ramp 3 hold for 18 min Carrier gas Adsorbent Trap Program Initial Temperature Ramp Cryofocus Trap Program Initial Temperature Ramp 1 Ramp 2 Adsorbent Trap Purge Inter-Trap Transfer through Stripper Make-up gas to Detector Detectors Temperature Detectors Range Detectors Full Scale Bead Current Helium, 3 ml/min 43 o C for 9.1 min 200 o C/min to 202 o C, hold for 50.25 min 79 o C for 3 min -200 o C/min to -179 o C, hold for 6.95 min 200 o C/min to 202 o C, hold for 47.25 min Nitrogen, 47 ml/min Helium, 10 ml/min Nitrogen, 25 ml/min 250 o C 10-12 amps/mv 1000 volts 3.150 amps Typical Sample Loading 300 ml A companion trap/column setup for the flame ionization detector is a duplicate design, with only the detector inserted in the setup. The two channels can be run simultaneously or singly. Analytical column for each channel is Varian CP624, 60 m, 0.32 mm ID, 1.8 µ film. The stripper column for each channel is Varian CP CB, 0.53 mm ID, 25 m length, and both are housed in a third valve oven that has been hijacked as an isothermal column oven with separate control from the convention column oven. Column flows for both columns is controlled with separate electronic flow controllers (EFC Type 3). Varian EFC type 3 is a true flow controller where the flow rate is specified and the back pressure of the column seeks a setting to provide the requested flow. Flows are not computed from column dimensions with Poisselle s formula. Inter-trap transfer through stripper columns is controlled by a third electronic flow controller (EFC Type 3) for the thermionic specific detector and with a digital flow controller. Purge flows for the adsorbent traps are controlled with digital flow controllers. The sample loading process is performed with dual mass flow controllers to allow large volumes to be loaded for thermionic specific detector and flame ionization detector independently. Sensitivity of the thermionic specific detector is directly impacted by the current applied to the bead, but a high setting can shorten service life. A current is selected to give the same noise as inboard the flame ionization detector. The medium concentration acrylonitrile/acetonitrile standard (7.8 and 12.2 ppbv/v, respectively) is NIST Standard Reference Material (NIST, Gaithersburg, Md); other standards (1 ppbv/v and 1 ppm V/V) are provided by Scott-Marrin, Inc. (Riverside, Ca); these standards are used for all calibrations. Multiple level calibrations are accomplished by adjusting the mass flow controller flow rate or sample loading interval or both.

RESULTS AND DISCUSSION Typical Chromatograms Ambient Air - An example of lab air is shown in Figure 2. Measured concentrations for target compounds are acetonitrile 0.285 ppbv, acrylonitrile 0.006 ppbv, and non-detect for nitromethane. Figure 1. Chromatogram of Ambient Air 3 Acetonitrile Acrylonitrile mvolts Nitromethane 0 25 35 Minutes Vehicle Exhaust A illustration of typical vehicle exhaust is shown in Figure 2. Measured concentrations for target compounds are acetonitrile 3.408 ppbv, acrylonitrile 0.225 ppbv, and nitromethane 1.528 ppbv. Figure 2. Typical Chromatogram of Vehicle Exhaust 7 mvolts Acetonitrile Acrylonitrile Nitromethane 0 Detector Linearity 25 35 Minut Acrylonitrile - Multi-point calibration is performed with NIST Standard Reference Material oxygenate standard and with 1 ppbv acrylonitrile/acetonitrile mix calibrated against the NIST mixture and is shown in Figure 3. The average response factor is 37,231 area/ppbv, with an RSD of 0.6% and r 2 of 0.998. Figure 3. Plot of Acrylonitrile Response Factors versus log[concentration] over the range of 0.020 to 6.78 ppb V, with 14 levels and 56 data points. 49,000 +30% Response Factor (area /concentration) 39,000 29,00 0 0.01 0.1 1 log [Concentration], ppbv +10% Averag -10% -30% 10

Acetonitrile - Multi-point calibration is performed with NIST Standard Reference Material oxygenate standard and with 1 ppbv acrylonitrile/acetonitrile mix calibrated against the NIST mixture. The calibration range is 0.03 to 10.8 ppbv, with 14 levels and 56 data points. The average response factor is 43,707 area/ppbv, with an RSD of 3.4% and r 2 of 0.998. Nitromethane - Multi-point calibration is performed with 1 ppmv nitromethane standard. The calibration range is 3.33 to 200 ppb V, with 6 levels and 18 data points. The average response factor is 1,503 area/ppbv, with an RSD of 7.3% and r 2 of 0.9995. Detection Limits Acrylonitrile - Detection limit is determined from 12 consecutive runs of the lowest standard used in the multi-point calibration (0.020 ppbv) and is calculated following protocols given in California Air Resources Board Method 1002. 9 Table 2 lists the raw areas for the series and computations to yield a preliminary detection limit of 3.3 ppt V (0.0033 ppb V) for acrylonitrile. Area Counts Table 2. Detection Limit Calculation for Acrylonitrile Area Counts 748 730 773 792 732 876 753 766 751 714 774 770 t * s 3 * 41 LOD = = = 0. 0033 m 37,231 ppbv where m = average response factor t = t-factor for 99% confidence level; 3 for >7 replicates s = standard deviation of at least five replicates Acetonitrile - Detection limit is determined from 12 consecutive runs of the lowest standard used in the multi-point calibration (0.020 ppbv). This calculation yields a detection limit of 0.0038 ppbv Nitromethane - Detection limit is determined from 9 consecutive runs of the lowest standard used in the multi-point calibration (3.33 ppbv). This calculation yields a detection limit of 0.13 ppbv. Nitrogen-Carbon Selectivity Samples from both ambient air and vehicle exhaust can have significant amounts of hydrocarbons. Potentially these can respond with the thermionic specific detector. The design of the detector minimizes its response to such hydrocarbons. To validate the selectivity, a mixture of hydrocarbons is run on both detectors and compared with the equivalent response of acrylonitrile. Selectivity is calculated by: Peak Area of Nitrogen Compound [ Hydrocarbon] n N : C Selectivity = Peak Area of Hydrocarbon Nitrogen Compound 244,846 955 3 N : C Selectivity = = 13,741 8,134 6.78 [ ] where n is number of carbon atoms in the hydrocarbon, and concentrations are ppbv. For example, propane selectivity calculates as:

Results for representative hydrocarbons are given in Table 3. Table 3. Nitrogen/Carbon Selectivity for several hydrocarbons. Component Stability of Acrylonitrile in Tedlar Bag N:C Propane 13,741 2Methylpropene 17,969 n-butane 16,469 13Butadiene 25,796 Acrylonitrile is inherently very reactive and could either degrade chemically with Tedlar or permeate through the polymer. Both high (1 ppmv/v) and low levels (6.78 ppb V/V) of acrylonitrile were filled into clean Tedlar bags and then repeatedly run approximately every hour for over 14 hours. To test of photochemical changes in the bag from ambient light, one Tedlar bag is enclosed in three layers of black plastic bags. Typical results for this test with darken black bags are shown in Figures 4 and 5. Figure 4. Stability of low level Acrylonitrile (6.78 ppbv/v) in darken Tedlar Bag over 14 hours Figure 5. Stability of high level Acrylonitrile (1 ppm V/V) in darken Tedlar Bag over 19 hours Relative Amount Remaining 100% 90% 80% 70% 0 4 FID TSD 8 12 16 Hours in Tedlar Relative Amount Remaining 100% TSD 80% 60% 0 4 8 12 16 20 Hours in Tedlar SUMMARY The Trace Nitrogen System is very sensitive to the measurement of acrylonitrile, acetonitrile and nitromethane with the Varian thermionic specific detector (TSD) and the concentration steps involved in focusing large volumes into focused loadings in the separation column. Detection limits are demonstrated for levels down to low part per trillion volume. Hydrocarbon concentrations expected in ambient air and vehicle exhaust samples are adequately rejected with the selectivity available with the thermionic specific detector. Acetonitrile is difficult to properly quantitate due to its ubiquitous presence in the modern laboratory, due to common use of this chemical as a reagent or liquid chromatography mobile phase. Blank runs frequently have detectable levels of acetonitrile. The other two target analytes are typically absent or close to their detection limits in ambient air and blanks.

Acrylonitrile is a common reactant in many polymer reactions and is often detected in sampling systems involving plastics, commonly employed in sample collection apparatus, especially vehicle test stations. Its concentration assessment becomes suspect with many surfaces possibly releasing acrylonitrile not detected by normal analytical tools, such as flame ionization or mass spectrometry, with their higher detection limits than possible with the thermionic specific detector. More importantly, both acrylonitrile and acetonitrile degrade readily over a few hours in clear Tedlar bags, a common sample container in vehicle emission testing. To reduce congestion in the organic analysis laboratory, samples are likely to be required to be collected in Summa canisters to lengthen their holding times. References 1. Australian Department of the Environment, Water, Heritage and the Arts, Acrylonitrile (2- propenenitrile) Fact Sheet; www.npi.gov.au/database/substanceinfo/profiles/7.html#environmentaleffects. 2. Agency for Toxic Substances and Disease Registry, Tox FAQ, 2008, www.atsdr.cdc.gov/tfacts125.html. 3. California Non-Methane Organic Gas Test Procedures, 2002, www.arb.ca.gov/msprog/levprog/cleandoc/ clean_nmogtps_final.pdf. 4. California Air Resources Board SOP No. MLD 032, 2002, www.arb.ca.gov/aaqm/sop/sop032.pdf. 5. USEPA, Compendium Method TO-15, Determination of Volatile Organic Compounds (VOCs) in Air Collected in Specially Prepared Canisters and Analyzed by Gas Chromatography/ Mass Spectrometry (GCMS), 1999, www.epa.gov/ttn/amtic/files/ ambient/airtox/to-15r.pdf 6. California Air Resources Board SOP No. MLD 066, 2002, www.arb.ca.gov/aaqm/sop/sop066.pdf. 7. Burgett, C.A., Smith, D.H., Bente, F.B., J. Chrom. 1977, 134; pp 57-64. Lotus Consulting 310/569-0128 Fax 714/898-7461 email ebramstoncook@msn.com 5781 Campo Walk Long Beach, California 90803