Application Note. Abstract. Introduction. Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution

Similar documents
Determination of Pesticide Residues in Oats by Automated. QuEChERS and LC/QQQ. Application Note. Abstract. Introduction

Tyler Trent, Applications Sales Specialist, Teledyne Tekmar P a g e 1

Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms

AppNote 6/2010. part a. Alternative Procedure for Extraction and Analysis of PAHs in Seafood by QuEChERS-SBSE-GC-MS KEYWORDS ABSTRACT

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Katherine K. Stenerson, Michael Ye, Michael Halpenny, Olga Shimelis, and Leonard M. Sidisky. Supelco, Div. of Sigma-Aldrich Bellefonte, PA USA

Analysis of Polycyclic Aromatic Hydrocarbons in Soil with Agilent Bond Elut HPLC-FLD

Application Note GCMS-09 Evaluation of Rapid Extraction and Analysis Techniques for Polycyclic Aromatic Hydrocarbons (PAHs) in Seafood by GC/MS/MS

Application Note # CA

METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS

Rely on Rxi -PAH Columns

Determination of Polycyclic Aromatic Hydrocarbons (PAHs) in Seafood Using GC/MS

PAH Analyses with High Efficiency GC Columns: Column Selection and Best Practices

Sample Pre-Treatment : Introduction to Commonly Used Techniques for Gas

Determination of 24 PAHs in Drinking Water

CALIBRATION OF GC/MS METHOD AND VALIDATION OF THE MODIFIED SAMPLE PREPARATION FOR DETERMINATION OF POLYCYCLIC AROMATIC HYDROCARBONS

Facility: Mansfield Revision 3. Title: PAHs by SPME Page 1 of 11

Application Note. Agilent Application Solution Analysis of PAHs in soil according to EPA 8310 method with UV and fluorescence detection.

ENVIRONMENTAL analysis

Anaylsis of Pesticide Residues in Rice Using Agilent Bond Elut QuEChERS AOAC Kit by LC-MS/MS Detection

Sensitive and rapid determination of polycyclic aromatic hydrocarbons in tap water

This project has been funded with support from the European Commission. This publication reflects the views only of the authors, and the Commission

Polycyclic Aromatic Hydrocarbons in Water by GC/MS PBM

The Use of Tandem Quadrupole GC/MS/MS for the Determination of Polycyclic Aromatics Hydrocarbons (PAHs) in Food Products

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System

METHOD 3600B CLEANUP

Selection of a Capillary

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Volatile Organic Compounds in Every Day Food

Fully automated QuEChERS clean-up and LC/MS-QQQ analysis of pesticides in fruits and vegetables.

Selection of a Capillary GC Column

Appendix 1: Polycyclic Aromatic Compounds: Nomenclature and Analysis

QuEChERS 101: The Basics and Beyond

Highly Sensitive and Rugged GC/MS/MS Tool

A Direct 5 ms Column Performance Comparison for Active Semi-Volatile Analytes

Analysis. Priority LC GC. Zebron PAH Accurately quantitate EU and EPA PAHs in less than 28 minutes

Journal of Chromatography A, 1114 (2006)

METHOD 3600C CLEANUP

Semivolatile Organics Analysis Using an Agilent J&W HP-5ms Ultra Inert Capillary GC Column

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples

AppNote 6/2010. part b. High Throughput Method for the Determination of PAHs in Seafood by QuEChERS-SBSE-GC-MS SCOPE PRINCIPLE

Validation Report 18

Method 8270C PAH. FD- Field Duplicate Samples

STANDARD OPERATING PROCEDURES

Validation Report Determination of isoprothiolane residues in rice by GC-MS/MS (QuEChERS method)

anthracene Figure 1: Structures of Selected Polyaromatic Hydrocarbons (PAHs)

Rapid Analysis of PAHs in Fly Ash Using Thermal Desorption and Fast GC TOF-MS

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs)

Developing Large Volume Injection (LVI) in Split / Splitless Inlets. Philip J. Koerner Phenomenex Inc. NEMC 2014

A Method for Simultaneous Analysis of 174 Pesticides in Grape Using GC-MS/MS

U.S. EPA Method 8270 for multicomponent analyte determination

USEPA Methods 8270 and 8260 on a Single GCMS Without Changing Columns

So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist

METHOD July J.W. Hodgeson. W.J. Bashe (Technology Applications Inc.) T.V. Baker (Technology Applications Inc.)

APPENDIX A TO PART 136 METHODS FOR ORGANIC CHEMICAL ANALYSIS OF MUNICIPAL AND INDUSTRIAL WASTEWATER METHOD 610 POLYNUCLEAR AROMATIC HYDROCARBONS

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

Application Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

A Single-Method Approach for the Analysis of Volatile and Semivolatile Organic Compounds in Air Using Thermal Desorption Coupled with GC MS

Application Note. Abstract. Authors. Environmental

Analysis of Semivolatile Organic Compounds Using the Agilent Intuvo 9000 Gas Chromatograph

Using the Agilent 7000B Triple Quadrupole GC/MS for Parts per Trillion Detection of PAH Metabolites in Human Urine

Advantages of Reversed Sandwich Injection for Pesticide Residue Analysis

Andrei Medvedovici, Florina Micăle, Florentin Tache

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Application Note. Abstract. Authors. Introduction. Food Safety

Amy Nutter, Applications Chemist; Teledyne Tekmar P a g e 1

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS

Choosing the Correct GC Column Dimensions and Stationary Phase

Jo Marie Cook Bureau of Chemical Residue Laboratories

Faster Semivolatiles Analysis with a Scaled- Down Method and GC Accelerator Kit

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

APPENDIX G. Data Management Rules. Dioxin Data Report Appendix G. Lower Duwamish Waterway Superfund Site: T-117 Early Action Area

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Validation Report 3 Determination of pesticide residues in cereals by GC-MS/MS (QuEChERS method)

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

Polyaromatic Hydrocarbon Emissions in Fly Ashes from an Atmospheric Fluidized Bed Combustor Using Thermal Extraction Coupled with GC/TOF-MS

Optimization of 1,4-Dioxane and Ethanol Detection Using USEPA Method 8260 Application Note

GC/MS: A Valid Tool for Soil Gas Hydrocarbons Speciation

ELECTRONICALLY REPRINTED FROM. Volume 34 Number 3 MARCH

Determination of Polycyclic Aromatic Hydrocarbons (PAH) Adsorbed on Soot Formed in Pyrolysis of Acetylene at Different Temperatures

Food analysis. Solutions for Your Analytical Business Markets and Applications Programs

Application Note. Authors. Abstract. Xin Sun Shandong Agriculture University, Taian, , China

Analysis of Pesticides and Contaminants using HS-SPME-GC/MS and DRS Detection. Blair Surridge, Tyler Dyer, Rene Bilideau, Paloma Bertolin Presoti

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry

Study of Residual Solvents in Various Matrices by Static Headspace

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

Facility: Mansfield Revision 5. Title: Alk-PAH by GC/MS-SIM Page 1 of 24

Analysis of Pesticides in Citrus Oil Using a Shimadzu GCMS-TQ8030. No. GCMS No. SSI-GCMS-1404

Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70

ANNE JUREK. Abstract: soils and are found. in can also with GC/MS. poster. in series. option for. There are problems. analytes. in methanol.

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

Get Selective. By Jaap de Zeeuw

Supporting Information

Validation Report 5 Determination of pesticide residues in cereals by GC-MS/MS (QuEChERS method)

Transcription:

Application Note Abstract Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution Page 1 Polycyclic Aromatic Hydrocarbons (PAHs) are a large group of organic compounds found naturally in the environment. PAHs are monitored by the US Environmental Protection Agency due to their carcinogenic characteristics. In recent global events, PAHs have come to the attention for contamination in sea food samples due to the oil spills. In the oceanic environment, PAHs are bio-available via the food chain and contaminated sediments which could have the potential to bioaccumulate in the marine organism we eat. QuEChERS is a Quick-Easy-Cheap-Effective-Rugged-Safe extraction method that has been developed for the determination of pesticide residues in agricultural commodities. Since its installment in 2003, QuEChERS has been adapted for use with many additional matrices and compound classes such as sea food and PAHs. The aim of this project is to validate the extraction performance of the AutoMate-Q40 by monitoring Polycyclic Aromatic Hydrocarbons (PAH) extracted from seafood. The target compounds were determined by gas chromatography mass spectrometry (GC-MS). Introduction Polycyclic Aromatic Hydrocarbons (PAHs) are chemical compounds that consist of fused aromatic rings. PAHs are a large group of organic compounds found naturally in the environment but can be also man-made. Since these compounds are pollutants, the United States Environmental Protection Agency (US EPA), United States Food and Drug Administration (US FDA) and National Oceanic and Atmospheric Administration (NOAA) monitor these compounds due to their mutagenic and carcinogenetic properties. 1,2 Due to recent oil spills around the globe PAHs have found their way into our nation s seafood. These compounds can enter marine organisms through contaminated soil/sediments or through the natural food chain. The QuEChERS extraction method is applicable for PAHs, since it offers good selectivity, and sensitivity when extracting these compounds in sea food. 3,4 The aim of this project is to evaluate the performance and versatility of the AutoMate-Q40 for the extraction of PAHS in shrimp and scallops. Gas Chromatograph coupled to a Mass Spectrometer (GC-MS) was employed for the detection of PAHs in seafood. Quantification was based on matrix-matched calibration curves. Sales/Support: 800-874-2004 Main: 513-229-7000

Experimental Instrument Conditions Page 2 Chemicals Structures See Figure 1 for the PAHs used in this study Figure 1 Polycyclic Aromatic Hydrocarbons (PAHs) Structures

Page 3 Sample Preparation Shrimp and scallops were purchased locally in Ohio. The samples were prepared following the procedure described in the AOAC Official Method 2007.01 Pesticide Residues in Foods by Acetonitrile Extraction and Partitioning with Magnesium Sulfate. 3 The samples were then stored frozen until the time of the extraction. For this analysis, the AutoMate-Q40 used 7.5 g of AOAC QuEChERS extraction salts (MgSO 4 and NaOAc). The AutoMate-Q40 also used the AOAC version of MgSO 4 (1200.0 mg), PSA (400.0 mg) and C18 (400.0 mg) for the dspe cleanup step. Figure 2 shows the sample preparation and extraction steps that are needed to extract the PAHs from seafood. Figure 2 AutoMate-Q40 : Automated Extraction Parameters for Seafood Sample Analysis Sample analysis was conducted using an Agilent GC/MS system. For separation of the compounds of interest, a Restek 5Sil MS column was used. Table I demonstrates the optimized GC/MS analysis parameters for both the chromatographic separation and analyte transitions. Figure 3 shows the GC chromatogram spiked PAHs at 45.0 ng/g. Table I GC/MS Parameters GC Parameters Column Oven Program Inlet Rxi-5Sil MS Column 30 m x 0.25 mm x 0.25 μm 60 C for 1 min, 15 C/min to 295 C for 5 min, Run Time 21.667 min 275 C, 1.2 ml/min helium, Splitless, 40 ml/min Purge Flow Transfer Line 240 C MS Parameters Mass Range Selective Ion Monitoring (SIM) Ion Source EI, 230 C

Figure 3 SIM Chromatogram of 16 PAH at 45 ng/g Page 4 1 Naphthalene 4 Acenapthylene 7 Phenanthrene 10 Pyrene 13 Benzo(b)fluoranthene 2 2-methyl-Naphthalene 5 Acenaphthene 8 Anthracene 11 Benz(a)anthracene 14 Benzo(k)fluoranthene 3 1-methyl-Naphthalene 6 Flurorene 9 Fluoranthene 12 Chrysene 15 Benzo(a)pyrene Results Calibration Results Calibration standards were prepared 10-400 µl/l using matrix match blanks for both shrimp and scallops. The correlation coefficients (r2) are shown in Table II. Table II Correlation Coefficients for Matrix Match Calibration Standards (Quadratic Regression) Compounds Shrimp Scallops Calibration r 2 Calibration r 2 Naphthalene 0.996 1.000 2-methyl-Naphthalene 0.996 0.999 1-methyl-Naphthalene 0.996 0.999 Acenapthylene 0.998 1.000 Acenaphthene 0.999 1.000 Flurorene 1.000 1.000 Phenanthrene 0.997 1.000 Anthracene 0.995 1.000 Fluoranthene 0.997 1.000 Pyrene 0.999 1.000 Benz(a)anthracene 0.996 1.000 Chrysene 0.997 0.999 Benzo(b)fluoranthene 0.998 1.000 Benzo(k)fluoranthene 0.990 1.000 Benzo(a)pyrene 0.991 1.000

Reproduciblilty and Accuarcy Results Page 5 Automating the QuEChERS extraction enables an easy, reliable and more reproducible extraction. The AutoMate-Q40 offers significant labor savings, while improving the reproducibility and consistency between samples. A precision and accuracy study was performed using the AutoMate-Q40. A 1.0 µg/ml stock PAH solution was used to fortify the seafood samples. Check standards were fortified at 10.0 and 15.0 µg/l using the AutoMate-Q40's ability to make standard additions. This translates to 30.0 and 45.0 ng/g in the final sample for seafood. These QC samples were quantified against their corresponding matrix matched calibration. The results for both shrimp and scallops can be seen in Tables III and IV. Table III Spike Recovery in Shrimp Compound 30 ng/g Spike PAH 45n g/g Spike PAH %Recovery %RSD %Recovery %RSD Naphthalene 87.53 13.92 95.29 9.11 2-methyl-Naphthalene 97.30 19.79 91.33 3.51 1-methyl-Naphthalene 97.70 15.66 91.69 7.48 Acenapthylene 110.08 4.77 102.20 4.51 Acenaphthene 102.32 10.45 102.47 3.86 Flurorene 113.07 8.87 102.97 4.99 Phenanthrene 102.27 11.38 96.13 9.51 Anthracene 103.22 9.93 103.00 3.30 Fluoranthene 106.70 7.62 107.11 9.19 Benz(a)anthracene 115.57 22.02 100.58 18.43 Chrysene 104.12 21.11 96.73 5.01 Benzo(b)fluoranthene 99.27 10.49 98.60 5.12 Benzo(k)fluoranthene 93.95 13.35 91.89 6.19 Benzo(a)pyrene 105.28 9.75 99.76 12.49 Table IV Spike Recovery in Scallops Compound 30ng/g Spike PAH 45ng/g Spike PAH %Recovery %RSD %Recovery %RSD Naphthalene 98.06 7.57 97.04 4.08 2-methyl-Naphthalene 98.87 12.99 97.82 6.24 1-methyl-Naphthalene 94.39 3.33 98.87 3.86 Acenapthylene 113.83 6.78 109.44 6.03 Acenaphthene 102.91 8.42 103.24 4.42 Flurorene 92.14 14.18 101.67 2.27 Phenanthrene 91.27 14.78 103.09 2.24 Anthracene 105.41 9.55 100.51 6.24 Fluoranthene 97.44 9.97 104.11 2.92 Pyrene 88.51 12.39 103.69 2.34

Page 6 Benz(a)anthracene 97.16 8.08 107.11 4.04 Chrysene 96.26 6.53 94.89 4.43 Benzo(b)fluoranthene 100.04 5.65 106.53 2.24 Benzo(k)fluoranthene 94.96 5.25 93.04 2.26 Benzo(a)pyrene 106.74 5.30 105.62 2.49 Conclusion This study demonstrates the Automate-Q40's ability to successfully process seafood samples for PAHs by the QuEChERS extraction method. By automating the liquid handling, addition of salt/buffers, sample mixing, pipetting, and liquid level sensing using the patent pending VialVision, the AutoMate-Q40 frees the scientist from a labor-intensive extraction method and exposure to unhealthy chemicals. The automated extraction process enables an easy, reliable and more reproducible extraction. This enables time and labor savings, while improving consistency and reproducibility of the extraction. The combined PAH spikes recoveries of 100.4%, with an average RSD of 8.14% exceed the requirement outlined for this application. These numbers indicate superb precision and accuracy thus validating the performance of the AutoMate-Q40 to adequately perform the QuEChERS extraction method for seafood. References 1. United States Environmental Protection Agency, Polycyclic Aromatic Hydrocarbons (PAHs), Office of solid waste Washington, DC 20460, January 2008 2. U.S. EPA Method 8270D, Revision 4, February2007, Semivolatile Organic Compounds by GasChromatography/Mass Spectrometry (GC/MS) 3. AOCA Official Method 2007.07 Pesticide Residues in Food by Acetonitrile Extraction and Partitioning with Magnesium Sulfate. Gas Chromatography/Mass Spectrometry and Liquid Chromatography/Tandem Mass Spectrometry, First Action 2007 4. M. Anastassiades: QuEChERS a mini-multiresidue method for the analysis of pesticide residues in low-fat products