Combination ph, ORP, T Electrode with Transmitter

Similar documents
Manual ph Probe & Oxidation Reduction Potential Probe Models 6528A and 6528B

ph Electrode basics ph Electrodes Model 19 B /1 =1 m 24 B /1 =1 m

INSTRUCTION MANUAL. Type: ORP500 C, ORP500 CD, ORP222 CD, ORP223 CD EN Introduction Helpful Operating Tips. 2

Analysis of cations and anions by Ion- Selective Electrodes (ISEs)

ORP Probe. Mini ORP. Reads. +/-2000mV. Range SMA. Connector. 95% in 1s. Response time 100 PSI. Max pressure. 60m (197 ft) Max depth 1 80 C

EXPERIMENT 1. Object: Measurement of ph of Water THEORY

ph Probes Lab vs. Process Care, Calibrations and Comparison Presented by: Michael Blackburn Technical Sales Specialist at Hach Company

The design and operational theory of ph electrodes is a very complex subject, explored only briefly here. What is important to understand is that thes

Measurements with Ion Selective Electrodes: Determination of Fluoride in Toothpaste

FOCUS: Water Pollkon Prevention and Control

PRACTICAL 3 ph AND BUFFERS

Understanding ph Troubleshooting and Diagnostic information

Chemistry: The Central Science. Chapter 20: Electrochemistry

Titration of a strong acid with a strong base with Cobra4

Chapter Objectives. Chapter 13 Electrochemistry. Corrosion. Chapter Objectives. Corrosion. Corrosion

ORP Probe ORP. Reads. +/-2000mV. Range. 95% in 1s. Response time 100 PSI. Max pressure. 60m (197 ft) Max depth 1 80 C. Temperature range C.

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

CHM 213 (INORGANIC CHEMISTRY): Applications of Standard Reduction Potentials. Compiled by. Dr. A.O. Oladebeye

ph Probe Spear Tip Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth

Review. Chapter 17 Electrochemistry. Outline. Voltaic Cells. Electrochemistry. Mnemonic

Sodium Sealed Electrode Sensor Bundle Product Number: ENSOD051

Chapter 18. Electrochemistry

EXPERIMENT 8 POTENTIOMETRY: DIRECT-MEASUREMENT OPTION

This sensor is now also available with a sturdier flat electrode which enables testing even smaller samples than the conventional electrode.

ph Probe Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth 1 99 C

Fluoride Sealed Electrode Sensor Bundle Product Number: ENFLU049

Ammonium Sealed Electrode Sensor Bundle Product Number: ENAMN020A

ph/redox Measurement CPM 280

Determination of fluorides in aqueous samples using membrane, ion selective electrode (ISE)

1) A ph/mv meter or an ion meter, either line operated or portable.

GENERAL INSTRUCTIONS GENERAL PREPARATION


Electro Analytical Methods

LCS Laboratory Inc. 700 Collip Circle, Unit 218, London ON, N6G 4X8, (519) ,

OPERATING INSTRUCTIONS

Chapter 20 Electrochemistry

Exercise 2-4. Titration of a Buffer Solution EXERCISE OBJECTIVES

Electrochemistry Pearson Education, Inc. Mr. Matthew Totaro Legacy High School AP Chemistry

Determination of fluorides in aqueous samples using membrane, ion selective electrode (ISE)

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

NO 500 DIN, NO 500 BNC NO 800 DIN, NO 800 BNC

#13 Electrochemical Cells

Ch 20 Electrochemistry: the study of the relationships between electricity and chemical reactions.

General Chemistry 1412 Spring 2008 Instructor: Dr. Shawn Amorde Website:

Exercise 2-2. Titration of a Strong Acid EXERCISE OBJECTIVES

Chemistry MultiMeasure Sensor PS-2170

S ENTEK Unit 6 & 7 Crittall Court, Crittall Drive, Springwood Industrial Estate, Braintree, Essex, CM7 2SE Tel: +44 (0) Fax: +44 (0)

Chapter 20. Electrochemistry

CALCULATIONS INVOLVING STRONG ACIDS & BASES. Write the ionization equation (strong acid) or dissociation equation (strong base)

READING A. INTRODUCTION CHE425L POTENTIOMETRY WITH K + ION-SELECTIVE ELECTRODE. Skoog, Holler and Crouch: Chapter 23 and Appendix 3.

Electrochemistry. The study of the interchange of chemical and electrical energy.

Chapter 20. Electrochemistry. Chapter 20 Problems. Electrochemistry 7/3/2012. Problems 15, 17, 19, 23, 27, 29, 33, 39, 59

Rapid RH Portable ph Meter. User's Manual

Total, active and effective alkali

GENERAL INSTRUCTIONS GENERAL PREPARATION

20 ACIDS AND BASES Standard Curriculum

To determine relative oxidizing and reducing strengths of a series of metals and ions.

POTENTIOMETRIC TITRATIONS & SOLUBILITY EQUILIBRIA

6 Acid Base Titration

EXPERIMENT 6. Properties of Buffers INTRODUCTION

Exercise 4-3. Titration of Weak Acids EXERCISE OBJECTIVE DISCUSSION OUTLINE. The 5% rule DISCUSSION

Ion Selective Electrodes for the Laboratory. Presented by Chris Cushman OTCO Water Laboratory Analyst Workshop Thursday, May 14, 2015

Practical 1P3 Electrode Potentials

Redox reactions.

Electrochemistry Pulling the Plug on the Power Grid

Operating Instructions for Ammonium ISE Specifications

The Cole-Parmer Ammonium Ion Electrode is used to quickly, simply, accurately, and economically measure ammonium ions in aqueous solutions.

Equivalent Yokogawa TM Sensors

Reference Electrode Storage and Master Reference Electrodes

Neutralization Titration Package (SCS-200) ph Neutralization Titration experiment

COLE-PARMER LABORATORY AMMONIUM ION ELECTRODE INSTRUCTION MANUAL

lect 26:Electrolytic Cells

8.2. The Equilibrium of Weak Acids and Bases. The Ion Product Constant for Water. 388 MHR Unit 4 Chemical Systems and Equilibrium

Chapter 18 Electrochemistry. Electrochemical Cells

Advanced Sensor Technologies, Inc. TEL: TOLL FREE: WOW-ASTI ( ) FAX:

possesses negative potential & undergoes oxidation preferably act as ANODE

All about ph! Is it as simple as it seems? The ph Workshop. Rick Noone Thermo Scientific Water Analysis Instruments, Orion products May 22, 2014

Unit 12 Redox and Electrochemistry

Chemistry 212 Lab, Spring Design of the Experiment: Standard and Non-Standard Reduction Potentials For Metal/Metal Ion Half-Cells

Appendices towards the Operation Manual of Ultrasonic milk analyzer Lactoscan

Cyclic Voltammetry. Fundamentals of cyclic voltammetry

High-Temperature High-Pressure ph and Reference Probes

WATER ANALYSIS The ph Value. The Redox Potential. ALMEMO ph and Redox Measurement. The Electrical Conductivity

10 samples per second

Electrochemical Cells

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT

Unit 11: Equilibrium / Acids & Bases Text Questions from Corwin

Classification. Barium nitrate dissolves in water to produce dissolved barium ions and dissolved nitrate ions.

POTENTIOMETRIC TITRATIONS & SOLUBILITY EQUILIBRIA. Background

Chapter 17 Electrochemistry

Frequently asked question about our new Platinum Water Ionizer

Introduction to electrochemistry

STANDARD OPERATING PROCEDURE

To measure ph s in a variety of solutions and mixtures and to account for the results obtained.

Lecture Presentation. Chapter 20. Electrochemistry. James F. Kirby Quinnipiac University Hamden, CT Pearson Education

Razi Vaccine & Serum Research Institute

Part A: Multiple Choice (23 marks total)

11. Introduction to Acids, Bases, ph, and Buffers

Introduction to Strong and Weak Acids

11.1. Galvanic Cells. The Galvanic Cell

Transcription:

Combination ph, ORP, T Electrode with Transmitter Technical Information and Manual 2014 Osorno Enterprises Inc. The content of this manual is protected by copyright. All rights reserved. OCS/1406

Combination ph, ORP, T Electrode with Transmitter. Technical Information and Manual. Table of Contents General Information...3 Application...3 Measuring Ranges...3 Measuring Principles...3 ph Measurement...3 Basic Theory...3 Measurement Electronics...4 Calibration...4 ORP Measurement...5 Basic Theory...5 Measurement Electronics...6 Calibration...6 Temperature...6 Basic Theory...6 Measurement Electronics...7 Dimensional Drawing...7 Material...7 Connecting Information...8 Ordering Information...8 Calibration Procedures...8 ph Calibration in Buffer Solutions...8 Calibration of ORP Electrode...9

General Information The combination electrode consists of the housing with electrodes and the transmitter that amplifies and converts the sensor analog signals into a digital format that it transmits via Ethernet. Each transmitter has its unique MAC address. The IP address can be assigned to the transmitter by a DHCP server, or can be assigned as a static address at set-up. The data can be accessed via Internet, provided the transmitter is connected to an Internet line, and an IP address has been assigned. The electrode is connected to the transmitter with a special cable. The transmitter itself requires a power outlet. The power cable has an integrated low-voltage power supply. Electrode, transmitter, connecting cable and power supply cable are included in the set. Application Municipal water and wastewater Industrial water and wastewater Aquaculture Measuring Ranges Values Units Range Accuracy ph 0-14 ph 1 0.1 ph ORP mv - 1,000 mv - + 1,000 mv 4 mv T C - 20 C - + 60 C 0.1 C Measuring Principles ph Measurement Basic Theory The ph value is used as a unit of measurement of the acidity or alkalinity of a liquid or partially liquid medium. The acidity or alkalinity of medium is determined by number of hydrogen (H + ) and hydroxyl (OH - ) ions. Acidic solutions have a higher concentration of H + ions, while alkaline (or basic) solution has higher number of OH - ions. The concentration of H + ions and OH - ions is equal at ph = 7 when the solution has a temperature of 25 C. ph is an inverse logarithmic measurement of the concentration of hydronium ions, as the H + ions are correctly called, per litre of solution: ph = -log 10 [H + ] The abbreviation ph originates from Latin potentia hydrogenii, meaning the power (exponent) of hydrogen. This concept was introduced by Søren Peter Lauritz Sørensen, a Danish chemist, in 1909. The ph value of the medium can be measured chemically by colour changes of certain indicators. Continuous measurement of ph is done with a glass electrode, in which hydronium ions in the solution exchange partially 1 The range given is the actual measuring range of the instrument. However, all ph electrodes have a non-linear deviation towards the end of their measurement range. Further, strongly alkaline solutions can rapidly and irreversibly degrade electrodes. It is advisable not to use these electrodes in strongly alkaline solutions for more than a few seconds, and to immediately wash them afterwards. Page 3 of 8

with alkali cations of a selective (glass) barrier and produce a measurable difference of potentials proportional to the solution s ph. It is important to understand that this active half-electrode works in conjunction with another half-electrode, the built-in reference electrode. The calibration process described below correlates the voltage differential between these two half-electrodes with the ph scale. In aqueous solutions, the ph depends strongly on the temperature. It is often overlooked that the neutral point of water itself depends on the temperature of the solution, owing to the temperature dependence of the selfdissociation constant of water, commonly denoted as K w ; the K w table of water is shown in Appendix A. Historically, ph values were determined by the ph-dependent change of the colour of some dyes ( indicators ). The use of glass electrodes has become the dominant measurement technology. However, glass electrodes require regular calibration 2, and degrade slowly with age 3. Electrode degradation is caused by the minute internal electrical current, and accelerates when external electronics increase the current through the electrode. Measurement Electronics Owing to the extreme resistance of glass, the electronics to which a glass electrode is attached offers a significant challenge. As a rule of thumb, transmitters for glass electrodes are expected to have an input resistance (impedance) of > 1 GΩ. Osorno's electronic transmitter has only about 5 fa 4 input bias current. Despite this current optimization, the response time of the transmitter electronics is less than a second. Calibration As pointed out above, ph electrodes require regular re-calibration. Usually, quarterly re-calibration will suffice. Standard calibration solutions are available from various vendors for ph values 4, 7, and 10. A two point calibration is required; it makes little differences which one of the three standard solutions is used. In the calibration process, the transmitter also re-calculates the slope, which is the slope coefficient of the linear dependance between electrode differential voltage and ph. This value is ideally -59.2 mv per ph unit 5, but as a theoretical value never reached even by new and unused electrodes. As a rule of thumb, electrodes with a slope of -53 mv, or 90% of the theoretical slope, are still usable. As an effect of ageing, the slope will decrease over time. Unused electrodes also age, although slowly. ORP Measurement Basic Theory ORP stands for oxidation-reduction potential (also called redox potential), typically measured in millivolt (mv), and indicates the ability of the substance to either release or accept electrons in a chemical reaction. When electrons are accepted, it is an oxidizing system. When electrons are released, it is a reducing system. The ORP is a very sensitive and dynamic parameter. It depends on the changes of the internal chemical equilibrium, or the introduction of new chemical substances to a solution. The ORP sensor is a two-electrode system consisting of a measuring and a reference electrode. The measuring electrode serves as an electron donor or electron acceptor, depending upon the test solution. For most substances capable of undergoing oxidation-reduction reactions, ORP is a ph dependant parameter 6 ; 2 Osorno recommends quarterly recalibration with appropriate calibration solutions. 3 The lifetime can be extended significantly when the electrodes are stored in the appropriate electrode storage solution, Never expose electrodes for an extended period of time to distilled water, or any other liquid of low ionic strength. 4 1 fa = 10-15 A current. 5 This follows from the Nernst equation, see below in the ORP section. 6 Only for substances where the underlying redox reaction does neither consume nor generate either H + or OH - ions, is Page 4 of 8

for an increase by one ph unit, 59.2 mv are to be subtracted from the measured ORP value when one chooses a single ph reference 7. This value of 59.2 mv can be calculated from the Nernst equation: E=E 0 R T /n F ln(c oxidized /c reduced ) with E - actual potential (mv); E 0 - standard potential (mv) ; R - universal gas constant (R = 8.314 J mol -1 K -1 ) T - absolute temperature (K), T = 273.15 + t, where t is temperature of the solution in C; F - Faraday constant (96,485 C mol -1 ); n - number of moles of electrons transferred in the redox reaction; c oxidized - oxidant concentration in mol l -1 c reduced - reductant concentration in mol l -1 If to compare ph and ORP measurement results, the ph value indicates a system s relative state for receiving or donating hydronium ions, while the ORP value characterizes a system s relative state for gaining or losing electrons. Unlike ph values with their direct relation of the concentration of hydronium ions, ORP values are significantly more difficult to interpret: they are likely the result of several independent redox reactions, often with unknown concentrations. Further, these redox reactions are not necessarily reversible, which is a required condition to apply Nernst's equation. Despite these restrictions, ORP has gained much ground in monitoring disinfection quality in water treatment and in the food processing industries, in environmental monitoring, and has become indispensable in monitoring biochemical processes. For the ORP electrode itself, commonly used material are either gold, or platinum, or graphite. Osorno uses platinum electrodes. As any other electrode, ORP electrodes require that the potential be measured as the difference against a reference electrode. In electrochemistry, all potentials are referenced against the standard hydrogen electrode (SHE); the SHE potential is by definition 0 V. Unfortunately, there is no practical solution to apply SHE outside of the settings of specialized laboratories, so that secondary references are always used in practical applications. Osorno's transmitter calculates the ORP that it reports on the basis of SHE, as required in electrochemistry. It must be pointed out that no all commercially available equipment follow this rule, so that the comparison of ORP values of different equipment may require to apply an offset to correct for the voltage of the reference electrode against SHE. Table 1: ORP offset for Reference Electrodes. SCE 8 Ag/AgCl - 1 M KCl Ag/AgCl - 4 M KCl Ag/AgCl sat. KCl Electrode potential 9 +241 mv +192 mv +228 mv +236 mv Osorno's transmitter applies Nernst's equation to adjust for the solution temperature, although equipment of others usually do not apply this temperature correction. It is important to keep this in mind when comparing ORP ORP ph independent. 7 This value is the factor RT/F in the Nernst equation, calculated for the electrochemical reference temperature of 25 C, and multiplied by the factor 2.303 for conversion of the natural logarithm into a decadic (common) logarithm. For temperatures other than 25 C, this value requires recalculation. It must be pointed out that this value is valid only for cases of n = 1, i.e. single electron transfer reactions, which covers most of the practical applications. 8 Standard calomel electrode. 9 Relative to SHE. Page 5 of 8

values of different equipment. Measurement Electronics Although the internal resistance of an ORP electrode is not nearly as high as that of a ph electrode, it is still well above 10 MΩ. The circuitry used internally in the transmitter is therefore modelled after that used for the ph electrode (see above). Calibration Unlike ph electrodes, ORP electrodes typically are not re-calibrated because there is no need to recalculate the measured voltage into any other value. ORP solutions available commercially are not true calibration solutions, owing to their limited stability, and their wide tolerances 10. This serves the purpose of checking the electrode, but is rather useless for calibration. Realistically, ORP measurement is the measurement of a voltage, and as such is intrinsically absolute and calibration-free. Temperature Basic Theory The built-in temperature sensor is a semiconductor 11 with low thermal resistance, and therefore short response time. The temperature can be read by external devices, and is also used internally for temperature corrected values according to the Nernst equation (above). Measurement Electronics The circuitry to which the temperature sensor is connected, is designed for fast response and low noise. 10 A tolerance of ±35 mv is a reasonable assumption. 11 Semiconductor of the TMP36 series, manufacturer Analog Devices. Page 6 of 8

Dimensional Drawings A. Dimensions B. Installation Material Components Electrode housing ph electrode ORP electrode Material PVC epoxy general purpose electrode with polypropylene junction platinum plates Ag/AgCl reference epoxy general purpose electrode with polypropylene junction platinum plates Ag/AgCl reference Connecting Information The 25.5 mm (1 1/2" NPT) tread is available on both ends of the electrode housing (see "Dimensional Drawings" - B. Installation). Page 7 of 8

Ordering Information The electrode can be ordered in following combinations: 1. ph, ORP, T - code OCS-pH-Eh-T 2. ph, T - code OCS-pH-T 3. ORP, T - code OCS-Eh-T Calibration Procedures ph Calibration in Buffer Solutions Requirements for ph calibration: Computer with network connection capability. Two ph calibration solution; frequently used solutions are ph 4, 7, or 10. Distilled water (if distilled water is not available, use tap water although this is a poor replacement). Paper towel or dry cloth. Calibration Steps: 1. Assure that the sensor unit is connected to the transmitter. 2. Assure that the transmitter is turned on and connected to a network that includes a DHCP server. 3. Obtain the IP address of the transmitter. The IP address can found either on the transmitter enclosure, if it is a static address, or is assigned by the DHCP server if a dynamic address assignment is used. 4. Connect your computer to the network where the transmitter is connected. 5. Once connected to the network, open a web browser (preferably Mozilla Firefox; Google Chrome is problematic). 6. Enter the IP address of the transmitter to load the website of the electrode transmitter. 7. Clean the electrodes/sensor with distilled water and wipe carefully with a paper or cloth do not use force. 8. Submerse the electrodes/sensor into the one of the calibration solution (solution must have a temperature of approximately 25 C) and allow 3-5 minutes for the value to stabilize. 9. When the value has stabilized, click on the calibration button for the buffer solution used (for example, if a calibration solution with ph 4 has been used, click the calibration button ph = 4, etc.). 10. When calibration with current solution is finished, repeat procedure from step 7 with a different calibration solution. 11. The transmitter accepts new calibration values with the click of the calibration button, and uses the last two entered values for the calculation of the slope. This concludes the calibration procedure. NOTE: Always complete a two point calibration. Otherwise, the internally calculated values may not be correct, and as a result, transmitted measurement values may be faulty. Calibration of ORP Electrode As laid out above, ORP electrodes do not require calibration. For testing the reliability of an ORP electrode, ZoBell's solution or Light's solution are frequently used 12. 12 Available from Osorno or other manufacturers. Page 8 of 8