Thermo Scientific Dionex IonPac AS24A Anion-Exchange Column

Similar documents
Thermo Scientific Dionex IonPac AS26 Anion-Exchange Column

Thermo Scientific. Anion-Exchange Column

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection

Dionex IonPac AS28-Fast-4µm column

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

columns IonPac AS22 Anion-Exchange Column

Keywords Haloacetic acids, Water analysis, 2-D ion chromatography, ICS-3000

columns IonPac AS18 Anion-Exchange Columns

columns IonPac AS17-C Anion Exchange Column

anion-exchange column

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water

Development of the Thermo Scientific Dionex IonPac AS26 Column for Haloacetic Acid Analysis

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Thermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System

The use of 2-D IC for the determination of Haloacetic Acids in Drinking Water

Ion Chromatography: Green Chemistry for a Green Environment. Ken Kirkbride Somerset, New Jersey October 12, 2011

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Concentrator and Trap Columns. Column: IonPac AG15, AS15, 2 mm. Eluent Source: EG40 Concentrator. Temperature: 30 C Column: IonPac AC15 (2 50 mm)

columns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection

Thermo Scientific Dionex IonPac CS17 Cation-Exchange Column

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

columns IonPac SCS 1 Silica Cation Separator

Determination of trace anions in concentrated hydrofluoric acid

Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC

Utility of the Charge Detector in Ion Chromatography Applications

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Determination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Determination of Inorganic Anions in Drinking Water by Ion Chromatography

Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

Inline sample preparation for the determination of anions in sodium hydroxide

for IonPac AG11-HC IonPac AS11-HC

Application Note 187. Brian DeBorba and Jeff Rohrer Thermo Scientific, Sunnyvale, CA, USA

Determination of Tartaric Acid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection

Direct Determination of Small Organic Acids in Sea Water by IC-MS

Thermo Scientific Dionex eluent suppressors for ion chromatography

Application of Eluent Generation for Trace Anion Analysis of Borated Waters

suppressors Eluent Suppressors for Ion Chromatography

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples

Determination of Trace Anions in Concentrated Bases Using AutoNeutralization Pretreatment and Ion Chromatography

Determination of Organic Acids in Beer Samples Using a High-Pressure Ion Chromatography System

The power to increase productivity. Thermo Scientific Dionex Reagent-Free Ion Chromatography (RFIC) System Capabilities

Expanded capabilities in ammonium and amine detection

Overcoming Challenging Matrices in Ion Chromatography

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

Accurate and Reproducible Determination of Organic Halogens Using Combustion Ion Chromatography

Determination of Sulfate and Chloride in Ethanol by Ion Chromatography

suppressors SRS -ULTRA Self-Regenerating Suppressor

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Determination of Methylamine in Drug Products

Determination of trace anions in high-purity waters by high volume/direct injection ion chromatography

The determination of trace anions in concentrated phosphoric acid

Determination of trace concentrations of oxyhalides and bromide in municipal and bottled waters

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Determination of trace anions in high-nitrate matrices by ion chromatography

IonPac Trace Cation Concentrator

Determination of Monochloroacetic Acid in Carbocisteine

High-Performance Chromatography Superior isocratic separation of

Determination of Inorganic Anions in Wastewater by Ion Chromatography

Determinations of Heat Stable Amine Salts and Amines in Amine Scrubbing Solutions Using Suppressed Conductivity and Charge Detection

The Determination of Trace Anions in Concentrated Phosphoric Acid

Determination of Trace Anions in Organic Solvents

Sample Preparation for Ion Chromatography

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

Determination of Common Inorganic Anions in Environmental Waters Using a Hydroxide Selective Column

Determination of urea in ultrapure water by IC-MS/MS

Monitoring Protein PEGylation with Ion Exchange Chromatography

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

ION CHROMATOGRAPHY SYSTEM S 150

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Determination of Adsorbable Organic Halogen in Wastewater

Determination of trace anions in basic solutions by single pass AutoNeutralization and ion chromatography

IC Columns Introduction

groups I and II cations, amines, divalent transition metals

A Platform Method for Pharmaceutical Counterion Analysis by HPLC

Analysis of Bulk Sodium Hypochlorite Feedstock for the Presence of HAAs and Other DBPs [Project #4412]

Determination of Silicate in High Purity Water Using Ion Chromatography and AutoPrep

PRODUCT MANUAL. OMNIPAC PAX-100 GUARD COLUMN (4 x 50 mm, P/N ) OMNIPAC PAX-500 GUARD COLUMN (4 x 50 mm, P/N )

Determination of Organic Acids and Inorganic Anions in Lithium-Containing Boric Acid-Treated Nuclear Power Plant Waters

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

Determination of trace anions in organic solvents using matrix elimination and preconcentration

HILIC Method Development in a Few Simple Steps

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

Determination of trace anions in concentrated glycolic acid

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches

4. Ion chromatography (IC) 4.1. Educational aims and objectives

Ion Analysis of Hydraulic Fluids in Fracking Process

Cation Exchange HPLC Columns

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Determination of silicate in high-purity water using ion chromatography and online sample preparation

Transcription:

CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS4A Anion-Exchange Column Product Specifications Thermo Scientific Dionex IonPac AS4A anion-exchange column is designed for the separation of haloacetic acid (HAA) anions in drinking water. When used with the D-IC method and suppressed conductivity detection, low µg/l (ppb) detection levels can be obtained.. Analysis of HAAs in Reagent and High-Ionic-Strength Water Using Two Dimensional Ion Chromatography (D-IC) First Dimension (Dionex IonPac AS4A Column) Pink Trace: Blue Trace: ppm ammonium chloride High-Ionic Water ( ppm chloride, ppm sulfate, ppm bicarbonate, ppm nitrate and ppm ammonium chloride). 4 4 Second Dimension (Dionex IonPac AS Capillary Column). 4 Peaks:. MCAA µg/l. MBAA. DCAA 4. BCAA. DBAA. TCAA. BDCAA. CDBAA. TBAA 4 The Dionex IonPac AS4A column is a high-capacity, hydroxide selective anionexchange column recommended for the separation of haloacetic acid anions in drinking water samples. Minimal baseline shifts and enhanced analyte sensitivity are obtained using the Thermo Scientific Dionex AERS Anion Electrolytically Regenerated Suppressor. Reagent-Free IC (RFIC ) systems provide simple, reproducible operation with eluent generation, requiring only a deionized water source to produce consistent, accurate potassium hydroxide (KOH) eluent. The D-IC method for the analysis of HAAs uses the Dionex IonPac AS4A standard bore column in the first dimension, while the Dionex IonPac AS Capillary column is used in the second dimension. The D-IC method allows for the analysis of high-ionic-strength samples without sample pretreatment. The Dionex IonPac AS4A column is available in standard bore (4 mm i.d.), microbore ( mm i.d.) and capilllary (.4 i.d.) formats allowing flow rates from. to. ml/min.

Highlights Separation of haloacetic acid anions in drinking water samples Low μg/l (ppb) levels of HAAs can be determined using the D-IC method Determine HAAs in high-ionic-strength samples without sample pretreatment High-Efficiency Particle Structure The Dionex IonPac AS4A column has been developed using a unique polymer synthesis technology. The stationary phase consists of a novel, hyper-branched anion-exchange condensation polymer, electrostatically attached to the surface of a sulfonated widepore polymeric substrate (Figure ). The resin capacity is controlled through the number of alternating coating cycles and Aggregate Monolith Technology, which uses resin agglomerates produced by combining two oppositely charged resins, then packing these resin agglomerates into a column before adding the final two layers of the monomer and amine. This achieves higher-capacity while still maintaining high chromatographic efficiency and reasonable column pressure. The Dionex IonPac AS4A 4 mm column uses a high-capacity resin ( µeq per column) with optimized selectivity for the haloacetic acids and other anions in drinking water. Determination of Haloacetic Acids in Drinking Water Using Conductivity Detection Haloacetic acids containing chlorine and bromine are formed during the chlorination disinfection of drinking water. The presence of haloacetic acids in drinking water has been linked to several adverse effects including bladder, kidney, and colorectal cancer. The Dionex IonPac AS4A column can separate the following HAAs: Monochloroacetic acid (MCAA) Dichloroacetic acid (DCAA) Trichloroacetic acid (TCAA) Monobromoacetic acid (MBAA) Dibromoacetic acid (DBAA) Tribromoacetic acid (TBAA) Bromochloroacetic acid (BCAA) Dibromochloroacetic acid (DBCAA) Dichlorobromoacetic acid (DCBAA) TEM of Bead Cross section SEM of SMP Bead First Dimension Conditions Column: Dionex IonPac AS4A/AG4A 4 mm Eluent: KOH: mm from to min, to mm from to 4 min, step to mm at 4 min Eluent Source: Thermo Scientific Dionex EGC III KOH Cartridge Flow Rate:. ml/min Inj. Volume: µl Temperature: C Dionex ASRS Suppressor, Thermo Scientific Dionex AutoSuppression device, external water mode.. First Dimension Second Dimension Cartoon of Surface Modification Figure. Structure of a Dionex IonPac AS4A column packing particle. 4 4. 4 4 Peaks:. MCAA µg/l. MBAA. DCAA 4. BCAA. DBAA. TCAA. BDCAA. CDBAA. TBAA 4 Second Dimension Conditions Column: Dionex IonPac AS/AG Capillary Eluent: KOH: mm from to min, step to mm at min, mm from to min, step to mm at min Eluent Source: Dionex EGC-KOH (Capillary) Cartridge Flow Rate: µl/min Concentrator: Thermo Scientific Dionex IonSwift MAC- Temperature: C Dionex ACES Suppressor, Dionex AutoSuppression device, external water mode Pink Trace: ppm ammonium chloride Blue Trace: High Ionic Water ( ppm chloride, ppm sulfate, ppm bicarbonate, ppm nitrate and ppm ammonium chloride) Figure. Determination of haloacetic acids using the Dionex IonPac AS4A and Dionex IonPac AS columns and D-IC.

Five HAAs including MCAA, DCAA, TCAA, Five HAAs including MCAA, DCAA, TCAA, MBAA, and DBAA are cited in the US EPA haloacetic acid regulation. This regulation requires that the total of these five HAAs does not exceed a maximum concentration limit (MCL) of μg/l. All drinking water plants in the United States must have a method to determine HAA levels in drinking water. The Dionex IonPac AS4A 4 mm column is designed for analysis of HAAs by D-IC in high-ionic-strength matrices. In the first dimension, the Dionex IonPac AS4A column provides the initial separation between the HAA anions and the major matrix ions, such as chloride, sulfate and carbonate. The matrix ions are diverted to waste while the HAA anions are concentrated on the Dionex IonSwift MAC- Monolith Anion Concentrator column. In the second dimension, the Dionex IonPac AS Capillary column provides the final separation of the HAAs prior to suppressed conductivity detection. Figure shows determination of HAAs in a drinking water sample using a potassium hydroxide gradient delivered by the Eluent Generator (EG). Low μg/l (ppb) levels of haloacetic acids can easily be determined using D-IC. MBAA, CDBAA, and TBAA degrade readily at a high ph. The reaction is temperature dependent. To minimize sample degradation, the separation is performed at sub-ambient temperature, specifically at C. For optimal performance set both the DC lower compartment temperature and the Dionex IC Cube temperature to C. The DC upper compartment temperature must be reduced in order for the Thermo Scientific Dionex IC Cube to maintain C. A cooled autosampler capable of maintaining samples at a temperature less than or equal to C is also recommended. For further detail on the instrument setup for D-IC analysis of HAAs, see the Product Manual for Thermo Scientific Dionex IonPac AS4A Column, Document No. 44. Determination of Haloacetic Acids Using Suppressed Conductivity Detection The Dionex IonPac AS4A (4 mm) column is optimized for separation of haloacetic acids in drinking water matrices with suppressed conductivity detection. Figure shows the determination of haloacetic acids using the Dionex IonPac AS4A 4 mm column. Column: Dionex IonPac AG4A/AS4A, 4 mm Peaks:. MCAA µg/l (ppb) Eluent: KOH Gradient. MBAA mm KOH from to min. DCAA mm to mm KOH from to min 4. BCAA mm KOH from to min. DBAA Eluent Source: Dionex EGC III KOH Cartridge. TCAA Flow Rate:. ml/min. BDCAA Injection Volume: µl. CDBAA Temperature: C. TBAA Dionex ASRS Suppressor, 4 mm, Dionex AutoSuppression device, recycle mode 4 4 Figure. Determination of HAAs using the Dionex IonPac AS4A 4 mm column and suppressed conductivity detection. Column: Dionex IonPac AG4A/AS4A, 4 mm Eluent: KOH Gradient mm to mm KOH from to min mm to mm KOH from to min mm to mm KOH from to min Eluent Source: Dionex EGC III KOH Cartridge Flow Rate:. ml/min Injection Volume: µl Temperature: C Dionex ASRS Suppressor, 4 mm, Dionex AutoSuppression device, recycle mode 4 Peaks:. Fluoride mg/l (ppm). Acetate. Formate 4. Chlorite. Bromate. Chloride. Trifluoroacetate. Nitrite. Sulfate. Chlorate. Bromide. Oxalate. Nitrate 4. Phosphate 4. Arsenate 4. Thiosulfate 4. Chromate 4. Citrate 4 4 4 Figure 4. Separation of various anions including inorganic anions, organic acids, oxyanions, and oxyhalides using a Dionex IonPac AS4A 4 mm column and potassium hydroxide eluent delivered by an EG cartridge.

4 Extended Application Capabilities The unique selectivity and high-capacity of the Dionex IonPac AS4A column makes it ideal for the development of specialized applications, providing excellent separation of environmental anions including inorganic anions, oxyhalides, oxyanions, and organic acids using potassium hydroxide eluent. Using gradient elution, these analytes are easily separated in < min as shown in Figure 4. The separation of inorganic anions and oxyhalides using the Dionex IonPac AS4A Capillary column is shown in Figure. System Requirements The Dionex IonPac AS4A column is designed for use with the Thermo Scientific Dionex ICS- + RFIC system equipped with an eluent generator. The Dionex IonPac AS4A column can also be used with older Dionex IC systems equipped with an EG or Thermo Scientific Dionex RFC- Reagent-Free Controller. The EG is used to automatically produce potassium hydroxide gradients from deionized water. The haloacetic acids MBAA, CDBAA and TBAA degrade under basic conditions at higher temperatures. The use of a column oven capable of maintaining C and an autosampler capable of maintaining C is required for optimal performance. Suppressor Recommendations For optimum ease-of-use and economy, the Dionex IonPac AS4A column should be used with the Thermo Scientific Dionex AERS Anion Electrolytically Regenerated Suppressor or the Thermo Scientific Dionex ACES Anion Capillary Electrolytic Suppressor. Anion Trap Columns When using the EG for eluent delivery, a Thermo Scientific Dionex CR-ATC Continuously Regenerated Anion Trap Column should be installed between the EG cartridge and the EG degas module. As an alternative for 4 mm and mm systems, a Dionex IonPac ATC-HC Anion Trap Column with Hydroxide Eluent Column can be installed between the pump outlet and inlet of the EG cartridge in the eluent generator module. Alternately, when performing sodium hydroxide gradient anion-exchange applications with the Dionex IonPac AS4A column using hand-prepared eluents, the Thermo Scientific Dionex IonPac ATC- Anion Trap column should be installed between the gradient pump and the injection valve to remove anionic contaminants from the eluent. Column: Dionex IonPac AG4A, AS4A (.4 mm) Eluent: KOH Gradient mm KOH from to min mm to 4 mm KOH from to min 4 mm KOH from to min Eluent Source: Dionex EGC-KOH (Capillary) Cartridge with Dionex CR-ATC Continuously Regenerated Anion Trap Column Flow Rate: µl/min Inj. volume:.4 µl Temperature: C Dionex ACES Suppressor, Dionex AutoSuppression device, recycle mode 4 Concentrator Columns For concentrator work with a 4 mm Dionex IonPac AS4A column, use the Dionex IonPac AG4A guard column, the Dionex IonPac UTAC-LP, UTAC-ULP, UTAC XLP, UTAC-LP, UTAC-ULP, or UTAC-XLP Ultra Trace Anion Concentrator columns; the Dionex IonPac TAC-ULP Trace Anion Concentrator column; or the Dionex IonPac TAC- Trace Anion Concentrator column, when a single piston pump such as the Thermo Scientific Dionex AXP Auxiliary Pump (pulse damper required) is used for sample delivery. Use the Dionex IonPac UTAC-LP, UTAC-LP or TAC-LP Trace Anion Concentrator column when the sample is delivered with a syringe or with a low 4 Peaks: mg/l (ppm). Fluoride.. Formate. Chlorite. 4. Bromate.. Chloride.. Nitrite.. Sulfate.. Chlorate.. Bromide.. Phosphate.. Nitrate. Figure. Separation of inorganic anions and oxyhalides using the Dionex IonPac AS4A Capillary column. pressure autosampler, such as the Thermo Scientific Dionex AS-DV Autosampler. For concentrator work with a.4 mm capillary column, use the Dionex IonPac AG4A Capillary Guard column or the Dionex IonSwift MAC- Concentrator column. For D-IC methods with a capillary column in the second dimension, use the Dionex IonSwift MAC- Concentrator column. For D-IC methods with the -mm column in the second dimension, use one of the Dionex IonPac Ultra Trace Anion Concentrator columns listed above. References. Stage Disinfectants and Disinfection Byproducts Rule: A Quick Reference Guide, p., US EPA, -F--

Dimensions Maximum Operating Pressure Mobile Phase Compatibility Substrate Characteristics Ion-Exchange Group Functional Group Characteristics Capacity Column Construction Specifications Dionex IonPac AS4A Analytical Column: 4 mm Dionex IonPac AG4A Guard Column: 4 mm Dionex IonPac AS4A Analytical Column: mm Dionex IonPac AG4A Guard Column: mm Dionex IonPac AS4A Capillary Column:.4 mm Dionex IonPac AG4A Capillary Guard Column:.4 mm psi ph 4; % HPLC solvents Analytical Column: Supermacroporous resin Bead diameter:. µm Pore size: Å Crosslinking: (%DVB): % Guard Column: Microporous resin Bead diameter: µm Pore size: < Å Crosslinking (%DVB): % Functional group: alkanol quaternary ammonium ion Hydrophobicity: Ultralow µeq/column (4 mm) µeq/column (4 mm) 4 µeq/column ( mm). µeq/column ( mm). µeq/column (.4 mm). µeq/column (.4 mm) PEEK with - threaded ferrule-style end fittings. All components are nonmetallic.

Ordering Information In the U.S., call () 4- or contact the Thermo Fisher Scientific Regional Office nearest you. Outside the U.S., order through your local Thermo Fisher Scientific office or distributor. Refer to the following part numbers. Analytical, Capillary and Guard Columns Dionex IonPac AS4A Analytical Column (4 mm) Dionex IonPac AG4A Guard Column (4 mm) Dionex IonPac AS4A Analytical Column ( mm Dionex IonPac Guard Column ( mm) Dionex IonPac Capillary Column (.4 mm) Dionex IonPac Capillary Guard Column (.4 mm) Anion Trap Columns Dionex CR-ATC Continuously Regenerated Anion Trap Column (For use with systems equipped with an eluent generator or RFC- Reagent-Free Controller) 4 Dionex CR-ATC Continuously Regenerated Anion Trap Column (for use with capillary anion columns) Dionex ATC- Anion Trap Column ( 4 mm) for use with 4 mm columns Dionex ATC- Anion Trap Column (4 mm) for use with the mm columns Dionex ATC-HC Anion Cation Trap Column ( mm) for use with the EG 4 Trace Anion Concentrator Columns Dionex IonSwift MAC- Monolith Anion Concentrator (. mm) 4 Dionex IonSwift MAC- Monolith Anion Column (. mm) 4 Dionex IonPac TAC-LP Trace Anion Concentrator (4 mm) 4 Dionex IonPac TAC- Trace Anion Concentrator Column ( mm) 4 Dionex IonPac TAC-ULP Trace Anion Concentrator ( mm) 4 Dionex IonPac UTAC-LP Ultra Trace Anion Concentrator Column Low Pressure (4 mm) Dionex IonPac UTAC-ULP Ultra Trace Anion Concentrator Column Ultra Low Pressure ( mm) 4 Dionex IonPac UTAC-XLP Ultra Trace Anion Concentrator Column Extremely Low Pressure ( mm) 4 Dionex IonPac UTAC-LP Ultra Trace Anion Concentrator Column Low Pressure (4 mm) Dionex IonPac UTAC-ULP Ultra Trace Anion Concentrator Column Ultra Low Pressure ( mm) Dionex IonPac UTAC-XLP Ultra Trace Anion Concentrator Column Extremely Low Pressure ( mm) Haloacetic Acid Internal Standards Thermo Scientific Dionex Monochloroacetic Acid MCAA--C, mg/l 4 Thermo Scientific Dionex Monobromoacetic Acid MBAA--C, mg/l 4 Thermo Scientific Dionex Dichloroacetic Acid DCAA--C, mg/l 4 Thermo Scientific Dionex Trichloroacetic Acid TCAA--C, mg/l 4 Product Specifications www.thermoscientific.com/dionex Thermo Fisher Scientific Inc. All rights reserved. ISO is a trademark of the International Standards Organization. PEEK is a trademark of Victrex PLC. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Thermo Fisher Scientific, Sunnyvale, CA USA is ISO : Certified. Australia + 4 Austria +4 Belgium + 4 4 Brazil + 4 Canada + 44 China + +4 Denmark +4 Finland + France + 4 Germany +4 4 4 India + 4 44 Italy + Japan + Korea + 4 Latin America + Netherlands + New Zealand +4 Norway +4 4 Singapore + Sweden +4 4 Switzerland +4 Taiwan + UK/Ireland +44 44 USA + 4 PS_E /S