CHEM Experiment Five Gas Chromatographic Analysis Of A Phenolic Extract. Objectives:

Similar documents
GAS CHROMATOGRAPHY (GC)

Chemistry Gas Chromatography: Separation of Volatile Organics

Chapter 27: Gas Chromatography

Figure 1. Structures for Vitamin B2 and Vitamin B1.

DETERMINATION OF THE DECOMPOSITION PRODUCTS OF CALCIUM OXALATE USING THERMAL GRAVIMETRY AND INFRARED SPECTROMETRY

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Gas Chromatography. 1. Experiment Category: 2. Experiment Name: 3. Date and Issue number: 4. Instructor Name: 5. Institution: Ain Shams University

2401 Gas (liquid) Chromatography

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

Volatile organic compounds (VOCs):

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

Chapter 31 Gas Chromatography. Carrier Gas System

Experiment UPHPLC: Separation and Quantification of Components in Diet Soft Drinks

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

CHAPTER 6 GAS CHROMATOGRAPHY

Chromatography. Gas Chromatography

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Gas Chromatography. Chromatography Laboratory Course. Dr. Christian Jungnickel Chromatography Course GC September 2005

High Pressure/Performance Liquid Chromatography (HPLC)

HPLC Praktikum Skript

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography. M. Subramanian

Dr. Jonathan Gutow Fall Looking for PCBs in Water or Can PCBs Wash out of Landfills and Contaminate Ground Water?

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

METHOD 3600B CLEANUP

METHOD 3600C CLEANUP

HPLC Background Chem 250 F 2008 Page 1 of 24

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

Quantitative Analysis of Caffeine in Energy Drinks by High Performance Liquid Chromatography

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

Introduction to Capillary GC

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

INVESTIGATING GAS CHROMATOGRAPHY rev 8/12

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

Fall 2012 Due In Class Friday, Oct. 19. Complete the following on separate paper. Show your work and clearly identify your answers.

METHANOLYSIS OF ACETAL

Physical Separations and Chromatography

INTERNATIONAL STANDARD

Gas Chromatography notes

Gas Chromatography (GC)

Gas Chromatography. Introduction

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Lab 3 Guide: Gas Chromatography (GC) (Sept 8-14)

High Performance Liquid Chromatography (HPLC) of Three Analgesics

PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY. Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC

G a s C h r o m a t o g r a p h y Determination of Ethanol in Wine by Head-Space Gas Chromatography

USGS Troy WSC Laboratory Ion Chromatography SOP EPA 300.0, Rev Jordan Road SOP. No. 1 Rev. No. 1.7 Troy, NY Date 01/25/18 Page 1 of 7

STANDARD OPERATING PROCEDURES

LEARNING OBJECTIVES CHEM 212: SEPARATION SCIENCE CHROMATOGRAPHY UNIT. Thomas Wenzel, Bates College. In-class Problem Set Extraction.

Chromatographic Separation

Introduction to Chromatographic Separations

Determination of Volatile Substances Proof of Food Adulteration

Remember - Ions are more soluble in water than in organic solvents. - Neutrals are more soluble in organic solvents than in water.

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

Gas Chromatography. A schematic diagram of a gas chromatograph

Understanding Gas Chromatography

DATES: LAB: Liquid Chromatography Separation of Grape Kool-Aid

Chapter 27: Gas Chromatography. Principles Instrumentation Detectors Columns and Stationary Phases Applications

Chromatography Lab # 4

METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS

Name Period Date. Lab 10: Paper Chromatography

Volumetric Analysis. Quantitative analysis answers the second question

Luminescence transitions. Fluorescence spectroscopy

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note.

Exercise in gas chromatography

Gas chromatography. Advantages of GC. Disadvantages of GC

Analytical Chemistry

Instrumental Chemical Analysis

Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis

Determination of Benzene, Toluene, Ethylbenzene and Xylene in River Water by Solid-Phase Extraction and Gas Chromatography

Thin Layer Chromatography

2] The plate height in chromatography is best described as 2

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Introduction to Capillary GC

The Theory of HPLC. Quantitative and Qualitative HPLC

CHAPTER 1. Introduction, Chromatography Theory, and Instrument Calibration

Introduction to Gas Chromatography

Using a mini-gas Chromatograph (GC): Identifying Unknown Compounds

Expectations for GC-MS Lab

7 INSTRUMENTAL CHROMATOGRAPHY

Water Injections in GC - Does Water Cause Bleed?

Chemistry 325 Instrumental Methods of Analysis March 13, Final Exam. Name

1. Preliminary qualitative analysis of unknown substances (liquid or solid).

Experiment 3: Analysis of Unknown Hydrocarbons by GC, NMR, and Chemical Tests for Unsaturation and Aromaticity

Methods of Analysis of Polychlorinated Biphenyl Congeners Using an Application-Specific Capillary GC Column

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS

Chromatography and Functional Group Analysis

Title of experiment and short description of the purpose of the experiment.

U.S. EPA Method 8270 for multicomponent analyte determination

Institute for Chemical Education, Fun With Chemistry; Vol. 1, Sarquis, Mickey and Sarquis, Gerry, Ed.; University of Wisconsin Madison, 1991,

Principles of Gas- Chromatography (GC)

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography

Sulfotepp impurities in Chlorpyrifos EC formulations

Transcription:

CHEM 3281 Experiment Five Gas Chromatographic Analysis Of A Phenolic Extract Objectives: The objectives of this experiment are: 1. to evaluate the fundamental parameters of gas chromatography; 2. to identify the components of a phenolic mixture and their order of elution by comparison of the retention times of standards to those of mixture components; 3. to determine detector selectivity and sensitivity 4. to measure the limit of detection for a specific component Text Reference: Introduction: Handbook of Instrumental Techniques for Analytical Chemistry, Frank Settle, editor. Prentice Hall, Upper Saddle River, NJ 1997, Ch 8. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 17 & 18. Skoog, Holler and Nieman, Principles of Instrumental Analysis, 5th edition, Saunders College Publishing, Fort Worth, TX 1998, Ch 26 & 27. The separation of mixtures by gas chromatography is accomplished by moving a gas over a liquid phase. The components of the mixture are separated according to their differential solubility in the two phases. In this experiment, the stationary phase has been coated onto the walls of a widebore fused silica capillary. The capillary provides a very compact column with a high number of theoretical plates. Thus, very efficient separations are possible in relatively short periods of time. At the end of the column, the effluent is divided into two streams which flow in parallel into a flame ionization and an electron capture detector. The data acquisition system will display the responses from both detectors in real time. This display mode will permit the rapid assessment of detector selectivity for each of the components in the mixture. The samples to be analyzed are mixtures of substituted phenols dissolved in methanol. This sample simulates samples one encounters following the extraction of industrial plant effluents (wastewater) which contains phenolic residues. Substituted phenols are on the Environmental Protection Agency's Priority Pollutants list. The procedure which follows is a modification of a

standard method for the determination of these priority pollutants in water. NOTE: Phenols are toxic substances. Use extreme caution in handling these mixtures. Eye protection and disposable gloves are to be worn at all times. Handle the syringes with care. Notify the TA immediately if you come in contact with the phenolic solutions. Experimental: 1. Obtain from the TA samples of six of the standards listed below, an unknown sample and five serum bottles containing methanol. Identify which six of the following substituted phenols you have received: Compound Molecular weight Boiling Point 2-chlorophenol 128.56 175 o C phenol 94.11 182 2-bromophenol 173.01 195 2,6-dimethylphenol 122.17 203 2-bromo-4-methylphenol 187.04 214 4-ethylphenol 122.17 218 4-chlorophenol 128.56 220 4-chloro-3-methylphenol 142.59 235 3-bromophenol 173.01 236 4-bromophenol 173.01 236 In addition, obtain a 100 l syringe and a 10 l gas chromatographic syringe for use in this experiment. Ask the TA to show you the proper use of both syringes. 2. The chromatographic system to be used with this experiment consists of a Varian Model 3300 Gas Chromatograph which has been interfaced to a computer system. The data acquisition and analysis package is the STAR program written by Varian. The gas chromatograph is controlled by a microcomputer which is built-in to the Model 3300. One can set the desired instrument parameters using the soft keyboard located on the front panel of the chromatograph. To set or change the column parameters, press the BUILD/MODIFY key located in the OPERATIONS segment of the panel. The prompt on the display should read Select Section or Table. Select COLUMN in the SECTIONS panel. A series of prompts will be displayed. Respond to each prompt by depressing the appropriate key(s) in the ENTRY panel followed by ENTER. In this manner, set the chromatographic parameters to the following values: - Initial Column Temperature: 115 o C - Initial Column Hold Time: 10.0 min - Temperature Program Column: NO (isothermal elution)

- Injector Temperature: 200 o C - Detector Temp: 250 o C - Detector A or B? A - FID Initial Attenuation: 8 - FID Initial Range: 10 - FID Autozero ON? Y - Time Program FID A? NO - ECD B Initial Attenuation: 8 - ECD B Initial Range: 10 - ECD B Autozero ON? Y - Time Program ECD B? NO - Method Complete-End Time: 10.00 Return to the OPERATIONS panel and press STATUS. Your detector parameters "program" will be stored in the onboard memory. NOTE: Find out what type of column you are using, length. bore size, what stationary phase, it s temperature limits before starting!! 3. ISOTHERMAL GC RUN: You have now setup the gc for isothermal operation. When the READY diode is illuminated in the GC CONTROL panel, rinse the 10 L GC syringe with the unknown sample a few times to minimize sample contamination by residue left in the syringe. Draw 1.0 L of the unknown sample into the syringe and inject this sample onto the column. The RUN diode should be illuminated once you have activated the sensing mechanism on the injector. The color monitor should also indicate that the run is in progress. In the lower two windows, the response from the Flame Ionization Detector (detector A) and the Electron Capture Detector (detector B) should be displayed. Note: your unknown should contain between 3 and 5 components plus a solvent peak. If you find a greater number of peaks, it may either be due to improper injection technique or a contaminated sample. Consult your TA if any problems arise at this point. When the program time has been exceeded, the run will automatically be halted. The printer will begin to output a hardcopy of the chromatograms from detectors A (FID) and B (ECD) as well as a table of peaks and their integrated areas. 4. TEMPERATURE PROGRAMMING RUN: Modify the chromatographic parameters to the following settings: - Initial Column Temperature: 85 o C - Initial Column Hold Time: 0.5 min - Temperature Program Column? YES - Program 1 Final Column Temp: 180 o C (temperature gradient elution) - Program 1 Col Temp Rate: 10.00 o C/min - Program 1 Col Hold Time: 0 min

Return to the OPERATION panel and press STATUS. When the READY diode is illuminated in the GC CONTROL panel, inject 1.0 L of the unknown sample onto the column. Again, when the program time has been exceeded, the run will automatically be halted and the chromatograms and table of peaks for the detectors will be generated. 5. STANDARDS RUN. Look at your isothermal and temperature program runs for your unknown. You decide what temperature (program or not) to run your standards and unknown at. You are looking for good separation in a miminum amount of time. Check your parameter decisions with the TA and then input on the front of the GC. Inject 1.0 L aliquots of each standard provided. Appropriately label each chromatogram and results table. Use the information obtained in this part to identify and determine the FID's sensitivity to each component in your mixture. Note: to save time, terminate each run after the elution of the standard by clicking the mouse on the RESET circle and depressing the RESET key in the GC CONTROL panel of the Model 3300 chromatograph. Run your unknown at the same exact conditions if you have not already done this. 6. Select one of the components of your mixture and determine its limit of detection in the following manner [this component must give an ECD response and have a retention time greater than 4 minutes]. Draw a 100.0 L aliquot from the standard solution provided by the TA and inject this volume into one of the serum bottles containing 900 l of methanol. The resultant mixture is a 1:10 dilution of the original standard. Prepare a serial dilution of the standard by withdrawing 100.0 l of the diluted standard and injecting that volume into another serum bottle containing methanol. Continue this procedure until you have five serial dilutions of the original standard Obtain chromatograms on each of the diluted samples, printing out the hardcopy of the chromatogram and results for the FID and ECD responses for each diluted sample. With this data, you will determine the limit of detection of your selected component for each detector and standard deviation of retention times. Calculations 1. For your standards make a table with the following column headings: compound, ng injected, retention time, area counts (FID & ECD), and relative response factor (FID & ECD). Remember mass sensitive detectors do not give equal area counts per unit concentration. Relative response factor is calculated by mass solute injected/area.

Use ng/area count. 2. For your unknowns, calculate the concentration of the unknown in ppm (i.e. mg/l or µg/ml or ng/µl). Multiply response factor by area to obtain mass and then divide by volume injected. Make a table for the unknown mixture including retention times, area counts, Response factor x area, concentration (ppm) 3. Make a data table for your serial dilution study including concentration, area and retention time. Calculate standard deviation for the retention times. Plot the FID and ECD response (area counts) versus the concentration of your selected standard (ppm) using the data obtained in the serial dilution study in part 6. Reporting the Results: The report should consist of a brief description of gas chromatography, labeled diagram of your instrument, instrumental parameters used, raw data-labeled, calculated data (in tables, please), sample calculations for anything calculated, all plots and a short discussion of the results. In addition, the discussion section should contain answers to the following questions: 1. Compare and contrast the chromatograms obtained in part 3 and part 4. What effect did the programmed temperature gradient have on the speed of the analysis? Was the resolution better when the chromatogram was obtained under isothermal or temperature gradient elution? 2. Use the uncertainty in retention time calculated from the serial dilution study as a good estimate of average retention time variation. Look at the two WORST resolved peaks in your unknown mixture. Calculate the alpha value for this pair and then answer this question: Can all components be reliably assigned based on retention time comparisons alone? Why or why not? 3. Compare and contrast the response factors from the FID and ECD. Is there a relationship between FID response and component structure? How do the response factors obtained for the FID compare to those obtained for the ECD? 4. What is the linear dynamic range based on your results for each detector? What is the limit of detection of your selected component for each detector. Estimate these parameters from your calibration curves for ECD and FID (part 6.) Estimate the detection limit as 3b/m; where b is y-intercept and m is the slope of the line. Why not use the correct definition of detection limit?