THE ROLE OF SINGULAR VALUES OF MEASURED FREQUENCY RESPONSE FUNCTION MATRIX IN MODAL DAMPING ESTIMATION (PART II: INVESTIGATIONS)

Similar documents
ESTIMATION OF MODAL DAMPINGS FOR UNMEASURED MODES

ABSTRACT Modal parameters obtained from modal testing (such as modal vectors, natural frequencies, and damping ratios) have been used extensively in s

CONTRIBUTION TO THE IDENTIFICATION OF THE DYNAMIC BEHAVIOUR OF FLOATING HARBOUR SYSTEMS USING FREQUENCY DOMAIN DECOMPOSITION

TIME-DOMAIN OUTPUT ONLY MODAL PARAMETER EXTRACTION AND ITS APPLICATION

Input-Output Peak Picking Modal Identification & Output only Modal Identification and Damage Detection of Structures using

ME scope Application Note 28

Malaysia. Lumpur, Malaysia. Malaysia

Structural Dynamics Lecture 4. Outline of Lecture 4. Multi-Degree-of-Freedom Systems. Formulation of Equations of Motions. Undamped Eigenvibrations.

Virtual Measurements in Experimental Structural Analysis

Performance of various mode indicator functions

Assessment of the Frequency Domain Decomposition Method: Comparison of Operational and Classical Modal Analysis Results

Collocated versus non-collocated control [H04Q7]

A NEW ANALYSIS APPROACH FOR MOTORCYCLE BRAKE SQUEAL NOISE AND ITS ADAPTATION

Random Eigenvalue Problems in Structural Dynamics: An Experimental Investigation

The Complex Mode Indicator Function (CMIF) as a Parameter Estimation Method. Randall J. Allemang, PhD Professor

Review of modal testing

Structural System, Machines and Load Cases

LECTURE 12. STEADY-STATE RESPONSE DUE TO ROTATING IMBALANCE

ME 563 HOMEWORK # 7 SOLUTIONS Fall 2010

ME 563 HOMEWORK # 5 SOLUTIONS Fall 2010

IOMAC'15 6 th International Operational Modal Analysis Conference

A STUDY OF THE ACCURACY OF GROUND VIBRATION TEST DATA USING A REPLICA OF THE GARTEUR SM-AG19 TESTBED STRUCTURE

EXPERIMENTAL MODAL ANALYSIS (EMA) OF A SPINDLE BRACKET OF A MINIATURIZED MACHINE TOOL (MMT)

Curve Fitting Analytical Mode Shapes to Experimental Data

1330. Comparative study of model updating methods using frequency response function data

The use of transmissibility properties to estimate FRFs on modified structures

Experimental Modal Analysis (EMA) on a vibration cube fixture M. Sc. Emanuel Malek Eindhoven November 2017

Nonlinear system identification with the use of describing functions a case study

Experimental Modal Analysis of a Flat Plate Subjected To Vibration

Finite Element Modules for Demonstrating Critical Concepts in Engineering Vibration Course

NV-TECH-Design: Scalable Automatic Modal Hammer (SAM) for structural dynamics testing

742. Time-varying systems identification using continuous wavelet analysis of free decay response signals

Stochastic Dynamics of SDOF Systems (cont.).

Design of Structures for Earthquake Resistance

Analysis of the Temperature Influence on a Shift of Natural Frequencies of Washing Machine Pulley

EXPERIMENTAL DETERMINATION OF DYNAMIC CHARACTERISTICS OF STRUCTURES

Improving the Accuracy of Dynamic Vibration Fatigue Simulation

Chapter 2 Lab Exercises for a Course on Mechanical Vibrations

An example of correlation matrix based mode shape expansion in OMA

Structural Dynamics Lecture 2. Outline of Lecture 2. Single-Degree-of-Freedom Systems (cont.)

Precision Machine Design

COMPLEX MODULUS AND DAMPING MEASUREMENTS USING RESONANT AND NON-RESONANT METHODS

Structural Dynamic Behavior of a High-Speed Milling Machine

Structural Dynamics Modification and Modal Modeling

An Estimation of Error-Free Frequency Response Function from Impact Hammer Testing

THE subject of the analysis is system composed by

Kaunadis [5] analyzed the vibration analysis of cantilever beam in free and forced condition. The cantilever beam was loaded at different locations.

Experimental and Numerical Modal Analysis of a Compressor Mounting Bracket

IOMAC' May Guimarães - Portugal IMPACT-SYNCHRONOUS MODAL ANALYSIS (ISMA) AN ATTEMPT TO FIND AN ALTERNATIVE

DSC HW 4: Assigned 7/9/11, Due 7/18/12 Page 1

Advanced Vibrations. Elements of Analytical Dynamics. By: H. Ahmadian Lecture One

MASS, STIFFNESS AND DAMPING IDENTIFICATION OF A TWO-STORY BUILDING MODEL

1. Background: 2. Objective: 3. Equipments: 1 Experimental structural dynamics report (Firdaus)

Structural System Identification (KAIST, Summer 2017) Lecture Coverage:

Francisco Paulo Lépore Neto. Marcelo Braga dos Santos. Introduction 1. Nomenclature. Experimental Apparatus and Formulation

Identification Techniques for Operational Modal Analysis An Overview and Practical Experiences

Francisco Paulo Lépore Neto. Marcelo Braga dos Santos. Introduction 1. Nomenclature. Experimental Apparatus and Formulation

Applied Modal Analysis of Wind Turbine Blades

Identification of modal parameters from ambient vibration data using eigensystem realization algorithm with correlation technique

A priori verification of local FE model based force identification.

System Parameter Identification for Uncertain Two Degree of Freedom Vibration System

DETERMINATION OF STATIC STIFFNESS OF MECHANICAL STRUCTURES FROM OPERATIONAL MODAL ANALYSIS

DEVELOPMENT AND USE OF OPERATIONAL MODAL ANALYSIS

e jωt = cos(ωt) + jsin(ωt),

IDENTIFICATION OF THE MODAL MASSES OF AN UAV STRUCTURE IN OPERATIONAL ENVIRONMENT

COMPARISON OF MODE SHAPE VECTORS IN OPERATIONAL MODAL ANALYSIS DEALING WITH CLOSELY SPACED MODES.

Dynamic Response of Structures With Frequency Dependent Damping

Wind tunnel sectional tests for the identification of flutter derivatives and vortex shedding in long span bridges

Identification of Time-Variant Systems Using Wavelet Analysis of Force and Acceleration Response Signals

EXPERIMENTAL STUDY ON CONCRETE BOX GIRDER BRIDGE UNDER TRAFFIC INDUCED VIBRATION

FLUTTER PREDICTION OF A SWEPT BACK PLATE USING EXPERIMENTAL MODAL PARAMETERS

Integration of measured receptance into a time domain simulation of a Multi Body Model using SIMPACK

Identification of crack parameters in a cantilever beam using experimental and wavelet analysis

Diagnosing Vibration Problems with Embedded Sensitivity Functions

High accuracy numerical and signal processing approaches to extract flutter derivatives

MV Module 5 Solution. Module 5

Experimental Modal Analysis

Damage detection of truss bridge via vibration data using TPC technique

The Design of a Multiple Degree of Freedom Flexure Stage with Tunable Dynamics for Milling Experimentation

Dynamics of structures

2001. A study on the application of the operating modal analysis method in self-propelled gun development

Damping Modelling and Identification Using Generalized Proportional Damping

Damping of materials and members in structures

OPERATIONAL TRANSFER PATH ANALYSIS OF A WASHING MACHINE

Seismic Base Isolation Analysis for the Control of Structural Nonlinear Vibration

System Theory- Based Iden2fica2on of Dynamical Models and Applica2ons

Simple Identification of Nonlinear Modal Parameters Using Wavelet Transform

Modal parameter identification from output data only

Investigation of traffic-induced floor vibrations in a building

Session 2: MDOF systems

Damage detection using output-only measurement by indirect approach

Identification Methods for Structural Systems. Prof. Dr. Eleni Chatzi Lecture 9-23 April, 2013

Time-domain simulation and nonlinear analysis on ride performance of four-wheel vehicles

Comparison of Automotive Structures Using Transmissibility Functions and Principal Component Analysis. A thesis submitted to the

Structural changes detection with use of operational spatial filter

2330. A study on Gabor frame for estimating instantaneous dynamic characteristics of structures Wei-Chih Su 1, Chiung-Shiann Huang 2 1

Identification of Damping Using Proper Orthogonal Decomposition

Introduction to Continuous Systems. Continuous Systems. Strings, Torsional Rods and Beams.

Car Dynamics using Quarter Model and Passive Suspension; Part V: Frequency Response Considering Driver-seat

DESIGN OF A HIGH SPEED TRAIN USING A MULTIPHYSICAL APPROACH

Transcription:

Uloga singularnih vrijednosti izmjerene matrice funkcije frekventnog odziva u procjeni modalnog prigušenja (Dio II: Istraživanja) ISSN 33-365 (Print), ISSN 848-6339 (Online) DOI:.7559/TV-2492894527 THE ROLE OF SINGULAR VALUES OF MEASURED FREQUENCY RESPONSE FUNCTION MATRIX IN MODAL DAMPING ESTIMATION (PART II: INVESTIGATIONS) Ferenc Pápai, István Szűcs Original scientific paper The singular value decomposition of the measured frequency response function matrix, as a very effective tool of experimental modal analysis is used over the last twenty-five years. The complex mode indication function has become a common numerical tool in processing experimental data. There are many references on the development of complex mode indication function including the enhanced mode indication function and its use together with the enhanced frequency response function to form spatial domain modal parameter estimation methods. Another amendment of the enhanced mode indicator function method is the extension of the single degree-of-freedom aspects of the complex mode indication function method to include a limited number of modes. In the paper, methods for estimation of damped eigenfrequencies, modal damping and mode shapes are presented that are based on singular value decomposition of frequency response function matrix. It is shown how to obtain phase information for the complex mode indication function, in order to use the standard single degree-of-freedom modal parameter estimation methods. New aggregated frequency response function is introduced. A leastsquares approximation will be presented for eliminating the error caused by frequency discretization. Analytical models and examples taken from vehicle industry are also used to demonstrate applications of the aggregated frequency response function method and estimation of modal damping. Keywords: complex mode indication function; damping estimate; experimental modal analysis; frequency response function matrix; singular values decomposition Uloga singularnih vrijednosti izmjerene matrice funkcije frekventnog odziva u procjeni modalnog prigušenja (Dio II: Istraživanja) Izvorni znanstveni članak Dekompozicija singularnih vrijednosti izmjerene matrice funkcije frekventnog odziva se, kao vrlo učinkovit alat eksperimentalne modalne analize, koristi zadnjih dvadeset i pet godina. Funkcija indikacije kompleksnog moda postala je uobičajeni numerički alat u obradi eksperimentalnih podataka. Veliki je broj referenci o razvoju funkcije indikacije kompleksnog moda uključujući poboljšanu funkciju indikacije moda i njenu primjenu skupa s poboljšanom funkcijom frekventnog odziva u razvoju metoda procjene modalnog parametra prostornog područja. Još jednu nadopunu poboljšanoj metodi funkcije indikatora moda predstavlja proširenje aspekata jednog stupnja slobode metode indikacije funkcije kompleksnog moda na ograničeni broj modova. U radu su predstavljene metode za procjenu prigušenih eigen frekvencija, modalnog prigušenja i oblika modova, zasnovane na dekompoziciji singularne vrijednosti matrice funkcije frekventnog odziva. Pokazano je kako dobiti faznu informaciju za funkciju indikacije kompleksnog moda u svrhu primjene standardnih metoda procjene modalnim parametrom s jednim stupnjem slobode. Uvedena je novo dobivena funkcija frekventnog odziva. Pokazat će se aproksimacija najmanjih kvadrata za eliminiranje greške izazvane diskretizacijom frekvencije. Korišteni su također analitički modeli i primjeri iz industrije vozila u svrhu demonstracije primjene dobivene metode funkcije frekventnog odziva i procjene modalnog prigušenja. Ključne riječi: dekompozicija singularnih vrijednosti; eksperimentalna modalna analiza; funkcija indikacije kompleksnog moda; matrica funkcije frekventnog odziva; procjena prigušenja In the Part I of this paper a new complex valued aggregator frequency response function (afrf) is introduced. The definition of the afrf function is jφ ( ω) afrf jω) = e σ ( jω), () ( u where j is imaginary unit, ( jω) u ( jω) φ( ω) = arg, 2 σ (jω) the first singular value of FRF matrix vs. frequency ω, u ( jω) the first left singular vector of FRF matrix vs. frequency ω. T simulations were made with MathCAD, MatLAB and LabVIEW.. 2DOF analytical models The model used in 2DOF simulation is shown in Fig.. Analytical investigations The properties and the applicability of the wellknown efrf, the vector tracking method and the newly developed aggregated afrf have been investigated via computer simulations. A 2DOF and a 5DOF model were examined with proportional and non-proportional damping. The modal parameters (undamped eigenfrequency and modal damping) were estimated based on the efrf and afrf, then they were compared to the analytical solution of the original model. The mode shapes were not the subject of this investigation. The Figure MDOF=2 test model The vector tracking method succeeded to put the left and right singular vectors in the right order when it was applied to the 2DOF model. The results of the vector tracking are shown on the bottom side of Fig. 2. The vector tracking method was able to sort the singular vectors independently of the damping model. Parameters: m = m 2 =, kg; k = k 2 = 4 N/m. Tehnički vjesnik 22, 5(25), 269-276 269

The role of singular values of measured frequency response function matrix in modal damping estimation (Part II: Investigations) For non classical modes the damping coefficients c,2 = c 2 =, N s/m should be chosen. For classical normal mode computations let the 3 proportional damping matrix be: C =, +, K. s M s Σ Σ.. 2 3 4 5. Untracked Σ Σ2 Σ Σ2 The efrf diagrams of the 2DOF system are drawn in Fig. 3. The least-square-method regression approximates the eigenvalues very well. The newly developed aggregated afrf can be seen in Fig. 4. Note that this is the only global function which gives the damped eigenfrequencies at their peaks. afrf afrf. Mode # Est. Mode #2 Est.. 2 3 4 5 Imag-Part 2 5 5 efrf. 2 3 4 5 Tracked Figure 2 Singular values of classical damped 2DOF model 3 Imag-Part. efrf efrf2 Mode # Est. efrf Mode #2 Est. efrf2. 2 3 4 5 efrf efrf2 5 5 5 5 2 5 5 Real-Part Figure 3 The efrf of classical damped 2DOF system 5 5 Real-Part Figure 4 The afrf of classical damped 2DOF system Four points were taken from the vicinity of each peak, then the complex eigenfrequencies were calculated using the circle fitting formula detailed in Part. The results can be seen in Tab. and Tab. 2. Table Classical damp. afrf estimates Eigenvalues (rad/s) Mode Exact Estimated #,226+2,359j,226+2,356j #2,674+32,354j,67+32,347j Table 2 Non-classical damp. afrf estimates Eigenvalues (rad/s) Mode Exact Estimated #,45+2,359j,44+2,352j #2,85+32,328j,8+32,3j The estimation of the complex eigenvalues was eligible, the approximations are almost the same as the exact values determined from the solution of the eigenvalue problem. The effect of additional noise was not examined. This method - beyond expectations - also approximates well the modal parameters of the 2DOF system with non-classical damping. Probably the reason for this is that the method does not use the left singular vector but only its phase angle..2 5DOF Analytical Model In this section we introduce the usage and applicability of estimation methods based on the efrf 27 Technical Gazette 22, 5(25), 269-276

Uloga singularnih vrijednosti izmjerene matrice funkcije frekventnog odziva u procjeni modalnog prigušenja (Dio II: Istraživanja) and afrf and the use of vector tracking on a 5DOF model. The structure of the 5DOF model is shown in Fig. 5. Simulations were made for two typical cases: Classical normal modes with light damping let, 6 the damping matrix: C = + E s K s M Non-classically damped structure using parameters given in Fig. 5. Mass in (kg): m m = 3, m 2 m = 26, m 2 m = 295 5, 6, 5, Stiffness in (N/m): k =, k 2 = 85, k 3 = 95, k 3 = 75 k, 6 = k, k 6, = k2, k, = k3 k 6, 7 =, 7 k, k 7, 2 =, 85k2, k, 2 =, k3, k, = k4 k 7, 8 =, 8k k 8, 3 =, 2k2 k 2, 3 =, 7k3 k 2, 2 =, 7 k4 k 8, 9 =, 2k k 9, 4 =, 5k2 k 3, 4 =, 9 k3 k 3, 3 =, 3 k4 k 9, =, 9k k, 5 =, k2 k 4, 5 =, 2k3 k 4, 4 =, 9 k4 k, =, k k, 5 =, k3 k 5, 5 =, k4 Figure 55DOF model.2. Lightly-damped system with classical normal mode The left and right singular vectors have special structure, when SVD is performed on the FRF of a system with classical normal modes. Measurement with rough frequency resolution does not provide enough points on the modal semicircle for the approximation of the modal parameters with circle fitting or the half-bandwidth method. In this example a measured FRF is simulated with a particular frequency resolution, when only one measured point falls on a modal semicircle, all other measured points are outside of the half-power bandwidth. The accuracy of the approximation was examined for this case. The model of the lightly-damped structure was built using the mass and stiffness data from Fig. 5 the damping 6 matrix was constructed as C =, M s + E s K, since we assumed proportional damping. The function of the singular values of the FRF matrix of this model can be seen in Fig. 6. Figure 6 Singular values of lightly-damped system with classical normal modes Tehnički vjesnik 22, 5(25), 269-276 27

The role of singular values of measured frequency response function matrix in modal damping estimation (Part II: Investigations) Singular values - Frequency. Σ. 3 4 5 2 4 6 8 Frequency [rad/s] Figure 7 Tracked singular values diagram of the light damped 5DOF system Note that the curve of the first singular value (red curve) detects all eigenfrequencies of the 5 modes. Mode #4 and mode #5 are close eigenfrequencies. The vector tracking method described in Part I gives the ordered singular value curves, as it is shown in Fig. 7. The vector tracking method put the singular values in the right order. It has to be noted that all the modes in this model were separated. Therefore, investigation has to be made for structures having overlapped modes. The approximations based on efrf and afrf were made for the damped eigenfrequencies of mode #, mode #4 and mode #5 (see Fig. 8). The exact eigenfrequencies and those extracted from the efrf and afrf are compared in Tab. 3. The parameters determined with different methods show close resemblance. Figure 8 The afrf of the light damped 5DOF system (Left: Amplitude-frequency diagram, Right: Nyquist-Plot) Table 3 efrf and afrf estimates of light damped 5DOF system Eigenvalues (rad/s) Mode Exact Estimation by efrf Estimation by afrf # 9,993E 3+99,928j 9,94E 3+99,929j 9,94E 3+99,929j #4,57+323,689j,57+323,69j,57+323,69j #5,6+334,85j,6+334,86j,6+334,86j.2.2 MDOF System with General Viscous Damping The behavior of the afrf method has also been investigated for the case when the structure has damping matrix C that does not satisfy the CM K = KM C condition, i.e. the system is generally damped. The damping coefficients (Ns/m) are: 2 c, 6 = c6, 7 = c7, 8 = c8, 9 = c9, = c, =, c 6, = c7, 2 = c8, 3 = c9, 4 = c, 5 =, 2 c, = c,2 = c2,3 = c3,4 = c4,5 = c5, = c, = c2,2 = c3,3 = c4,4 = c5,5 =,2,5 The singular values of the FRF matrix versus frequency are plotted in Fig. 9. 272 Technical Gazette 22, 5(25), 269-276

Uloga singularnih vrijednosti izmjerene matrice funkcije frekventnog odziva u procjeni modalnog prigušenja (Dio II: Istraživanja) Singular Values - Frequency.. Σ 3 4 5 2 4 6 8 3 Figure 9 Non-tracked singular values of generally damped 5DOF model As it can be seen in Fig. 9, the peak which belongs to mode #5 is not detectable on the curve of the st singular value (red curve). This lost mode becomes visible on the plot of the 2 nd singular value (see Fig. ). The first singular value was used to estimate the eigenfrequency of mode # and mode #4, the second singular value was used for mode #5. The results of the approximations are in Table 4. The extracted eigenfrequencies show close resemblance with the exact values. Figure The afrf of the generally damped 5DOF system (Left: Amplitude-frequency diagrams of afrf and afrf 2 Right: Nyquist-Plot) Table 4 efrfand afrf estimates of generally damped 5DOF system Eigenvalues (rad/s) Mode Exact Estimation by efrf Estimation by afrf #,2963E 3+99,923j,285E 3+99,92j,288E 3+99,96j #4 6,623+323,67j 6,626+323,492j 6,588+323,53j #5 8,72+334,6j Not detected 8,83+334,4j.3 Conclusion of Analytical Experiments Analyzing the result of the computer simulations leads to the following statements: the vector tracking method has only been verified for structures having separated modes, further investigation is necessary for overlapped modes; both the efrf and afrf can be used for parameter estimation; the least squares approximations only use a few points on the first singular value function in the vicinity of each peak instead of using all the measured data; a diagram plotting all singular values has proven to be useful to detect all peaks; when two modes overlap, the second singular value can be used to estimate the modal parameters. 2 Experimental Investigations The frequency response of a train s brake arm was measured to demonstrate the use of the afrf. The brake arm and its place in the brake system can be seen in the pictures below (see Fig. ). Tehnički vjesnik 22, 5(25), 269-276 273

The role of singular values of measured frequency response function matrix in modal damping estimation (Part II: Investigations) Figure Location of investigated part in the brake system (Left: Bogie equipment, Middle: Compact wheel brake caliper, Right: Brake arm www.knorr-bremse.hu 2. Experimental Setup A total of 2 key points are selected in order to obtain full information about the dynamics of brake-arm, and their distribution is shown in Fig. 2b. Single-input single-output approach is employed during the modal test. Each time response vibration acceleration location Y and 2Z, while impacted by a hammer with force transducer is roved from point 2 in directions Y and Z. Ni = 2, N = 4. Figure 2 The brake-arm (Left: Test specimen view, Right: Distribution of measurement points, wireframe model, Np = 2) PCB accelerometer PCB impulse hammer crio 922 crio 94 NI9234 Test specimen ETHERNET y x LabVIEW WinModal Figure 3 Schematic representation of the experimental setup of the brake-arm (EMA, SISO, FRF measurements) - The whole experimental setup includes: impact hammer: PCB small force hammer (86C3) Sensitivity: 2,25 mv/g accelerometers: PCB piezo transducers signal acquisition: NI Compact RIO, FPGA module, NI9234 four-channel dynamic signal acquisition module analysis apparatus: ModalVIEW (LabVIEW application). Measurements of the EMA (Experimental Modal Analysis) brake-arm, SISO (Single Input Single Output), and FRF (Frequency Response Function) were performed (Fig. 3) and (Fig. 4). A schematic diagram of the experimental setup is shown in the illustration. 274 Figure 4 Experimental setup view Technical Gazette 22, 5(25), 269-276

Uloga singularnih vrijednosti izmjerene matrice funkcije frekventnog odziva u procjeni modalnog prigušenja (Dio II: Istraživanja) on the afrf in the investigated frequency range (Fig. 6). Modal damping and the damped eigenfrequency were estimated by applying the Eq. () formula to the afrf. Then the parameter estimations were performed by circle fitting detailed in the Part I in order to approximate the regression curve (Fig. 6). The excitation and response measurements were performed horizontally (Y) and vertically (Z). The total number of the measured locations was 62. Frequency range: 55 Hz, frequency resolution df =,4 Hz. 2.2 Parameter Identification The measured point-to-point FRF are plotted on a waterfall diagram in Fig. 5. Nm = 7 modes were detected Waterfall,,,, 2 3 4 5 6 7 8 Frequency [Hz] 9 2 3 4 5 6 Figure 5 Waterfall diagram of 62 FRFs Singular values,78e+4 st 2nd afrf Nyquist 8 Fitted E+3 7 6 E+2 5 E+ 4 3 E+ 2 E- 3,8E-2 2 4 6 8 Frequency [Hz] 2 4-4 6-2 2 Real part 4 6 Figure 6 The afrf (yellow), afrf2 (blue) values and fitted afrf (green) versus frequency By performing SVD on the measured FRF the damped eigenfrequencies can easily be determined. Not every mode can be detected on every local FRF. For example mode#3 cannot be detected on the FRF of 2ZY location (see Fig. 7). Using the estimated global parameters of the system the residues can be approximated with linear regression. In Fig. 7 the result of the approximation is plotted for location 2ZY. The eligibility of using the afrf for parameter estimation is verified by this experiment. Measured 2Z Y.frf Fitted 2Z Y.frf Meas. 4 Curor 2 Fitted 8 6 4 2, -2, -4-6, 2 3 4 5 6 8 9 7 Frequency [Hz] 2 3 4 5 6-5 5 Real part 5 Figure 7 Selected (Location: 2ZY) measured (black) and fitted (red) FRF diagrams The regression of δ i modal damping factors was performed with Pápai-Adhikari-Wang method []. In Fig. 8 the Lehr damping ratios can be seen for each measured mode, the estimation was based on the afrf. There are two groups of modes, in both groups the modal damping factors are linear functions of the damped eigenfrequency. The fitted curves are plotted in Fig. 9. Tehnički vjesnik 22, 5(25), 269-276 The modal damping factors determined with regression for these two mode groups:,935 + 2,67 E 4 ω s 3,437 δ 2 (ω ) = + 3,45 E 4 ω s δ (ω ) = (2) 275

The role of singular values of measured frequency response function matrix in modal damping estimation (Part II: Investigations) 4 References [] Pápai, F.; Adhikai, S.; Wang B. T. Estimation of modal Dampings for Unmeasured Modes. // Slovak Journal of Civil Engineering. 2, 4(22), pp. 7-27. DOI:.2478/v89-2-8-3 Authors addresses Figure 8 Estimated damping factors vs. damped eigenfrequencies Ferenc Pápai, Assoc. Prof. PhD, Dr. Budapest University of Technology and Economics, Faculty of Transportation Engineering and Vehicle Engineering, Department of Vehicle Elements and Vehicle-Structure Analysis H- Budapest, Stoczek u. Hungary E-mail: papai@modal.hu István Szűcs, Assoc. Prof. PhD, Dr. University of Pécs, Pollack Mihály Faculty of Engineering and Information Technology, Department of Infrastructure and Technical Geoinformatics H-7624 Pécs, Boszorkány u. 2. Hungary E-mail: dr.szucsistvan@t-online.hu Figure 9 Regression of modal damping factors by mode groups Note that the coefficients of these functions depend on the support of the structure. For reasons of brevity, this article does not deal with the effect of separating the structure from the support. 3 Conclusions In this article the use of the singular value decomposition of the FRF in order to estimate modal parameters was investigated. We found that the peaks of the singular value function estimate the damped natural frequency well. A new aggregated frequency response afrf was derived from the efrf known from the literature. The properties of the afrf function are: it is one complex function of frequency for the whole MDOF system, each peak on the absolute value function indicates a mode, and the corresponding frequency of a peak approximates the damped natural frequency, this function contains phase information, thus every mode is represented as a modal circle on the Nyquist plot, it smoothes noise, the modal damping can be estimated with linear regression, not necessarily all points have to fall in the half-power bandwidth, also successful when only data with rough frequency resolution is provided. Acknowledgment The authors acknowledge the support of the "New Széchenyi Plan Új Széchenyi Terv TÁMOP-4.2./B- 9//KMR-2-2". 276 Technical Gazette 22, 5(25), 269-276