ORTEC. SLP Series Silicon Lithium-Drifted Planar Low-Energy X Ray Detector Product Configuration Guide

Similar documents
ORTEC. GLP Series Planar HPGe Low-Energy Detector Product Configuration Guide. Configuration Guidelines

GLP Series Planar HPGe Low-Energy Detector Product Configuration Guide

ORTEC. GEM Series Coaxial HPGe Detector Product Configuration Guide. Configuration Guidelines

High-Performance Germanium Coaxial Detectors for Safeguards and Non-Destructive Assay Product Configuration Guide

ORTEC. PROFILE Coaxial HPGe Photon Detector Product Configuration Guide

ORTEC. GEM Series Coaxial HPGe Detector Product Configuration Guide. Configuration Guidelines

ORTEC GMX Series Coaxial HPGe Detector Product Configuration Guide

PROFILE S and C Series P-type Semi-planar and Coaxial HPGe Detectors

ORTEC. October 23, 2017 Product Guide

Chem 481 Lecture Material 3/20/09

Flanged Cryostats.

Advanced and Special Detector Programs from ORTEC Historical and Next Step Perspective

AGATA preamplifier performance on large signals from a 241 Am+Be source. F. Zocca, A. Pullia, D. Bazzacco, G. Pascovici

ORTEC was founded in 1960 by researchers from Oak Ridge National Labs to commercialize charged particle detectors

Gamma and X-Ray Detection

PROFILE S and C Series

Microscopy Cryostat System

Silicon Drift Detectors: Understanding the Advantages for EDS Microanalysis. Patrick Camus, PhD Applications Scientist March 18, 2010

ORTEC. Overview of Semiconductor Photon Detectors. GEM (P-type) and GAMMA-X (N-type) Coaxial Detectors. Efficiency as a Function of Energy

He-3 Neutron Detectors

HPGe detector fabrication at CANBERRA. V. Marian, M.O. Lampert, B. Pirard, P. Quirin, J. Flamanc CANBERRA Specialty Detectors (Lingolsheim)

Measurement of the n_tof beam profile in the second experimental area (EAR2) using a silicon detector

Pulse Height Analysis System (PHA) designed for W7-X Presented by Monika KUBKOWSKA

ORTEC. Introduction to Charged-Particle Detectors. Silicon Charged-Particle Detector Manufacturing

Optimization of Electrically Cooled Complex HPGe Detector

1 of :32

RANGE OF ALPHAS. Advanced Laboratory, Physics 407 University of Wisconsin Madison, Wisconsin 53706

ORTEC. Review of the Physics of Semiconductor Detectors. Interaction of Ionizing Radiation with Semiconductor Detectors. Heavy Charged Particles

Compton suppression spectrometry

Information on the test material EDS-TM002 and the BAM software package EDX Spectrometer Test for determination of the spectrometer performance

Chapter 8 Hyper-Pure Germanium Detector

System design of 60K Stirling-type co-axial pulse tube coolers for HTS RF filters

On the development of compound semi-conductor thallium bromide detectors for astrophysics

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

ONYX -MCE MULTI-CHANNEL OPTICAL FIBER PYROMETERS WITH ACTIVE EMISSIVITY COMPENSATION PRECISION TEMPERATURE MEASUREMENT FOR DEMANDING INDUSTRIAL

Outline. Introduction, motivation Readout electronics, Peltier cooling Input J-FETsJ

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

Semiconductor X-Ray Detectors. Tobias Eggert Ketek GmbH

Chapter 8 Hyper-Pure Germanium Detector

Special SLS Symposium on Detectors

Detectors for High Resolution Gamma-ray Imaging Based on a Single CsI(Tl) Scintillator Coupled to an Array of Silicon Drift Detectors

SEM. Chemical Analysis in the. Elastic and Inelastic scattering. Chemical analysis in the SEM. Chemical analysis in the SEM

X-RAY SCATTERING AND MOSELEY S LAW. OBJECTIVE: To investigate Moseley s law using X-ray absorption and to observe X- ray scattering.

Grounding and Shielding

Acceptance test of the AGATA Ge detectors

The GERDA Phase II detector assembly

Efficiency and Attenuation in CdTe Detectors

Application Note GA-301E. MBMS for Preformed Ions. Extrel CMS, 575 Epsilon Drive, Pittsburgh, PA I. SAMPLING A CHEMICAL SOUP

arxiv: v1 [nucl-ex] 20 Dec 2008

University of Trieste INFN section of Trieste. ALP signatures in low background photon measurements

Compton Camera. Compton Camera

Chapter Seven (Nuclear Detectors)

A dual scintillator - dual silicon photodiode detector module for intraoperative gamma\beta probe and portable anti-compton spectrometer

Automated Determination of Crystal Reflectivity in the X-ray Laboratory

Summary of readout test of DSG prototype with IPA4 cold preamp. C. Cattadori, M. Bernabe-Heider, O. Chkvorets, K. Gusev, M.

Operating Instructions for Digital Manometer. Model: MAN-SD

Wolter Imaging On Z. Chris Bourdon, Manager Z Imaging and Spectroscopy Julia Vogel, LLNL; Ming Wu, SNL ICF Diagnostics Workshop, October 5 th 2015

Establishing an ISO-CART Measurement Station to Meet Government Burial Regulations for Radioactive Material

Study of PC-HPGe detector for dark matter search

arxiv:astro-ph/ v1 4 Sep 2001

ORTEC Experiment 24. Measurements in Health Physics. Equipment Required

S8 TIGER Series 2 for ASTM D 6443

X-ray spectrometry with Peltier-cooled large area avalanche photodiodes

Siletz APD Products. Model VFP1-xCAA, VFP1-xKAB Packaged APDs

Charge readout and double phase

Which Optistat is right for you?

NUCL 3000/5030 Laboratory 2 Fall 2013

EDS Mapping. Ian Harvey Fall Practical Electron Microscopy

Technical Note 103. Response Enhancement for the Loral CCDs. using Ultra-Violet Flooding. A. P. Oates (RGO)

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

M90 20W. High Power LED PRODUCT DATASHEET. RoHS Compliant

The energy calibration system of the CUORE double beta decay bolometric experiment

EFFICIENCY AND RESOLUTION OF GERMANIUM DETECTORS AS A FUNCTION OF ENERGY AND INCIDENT GEOMETRY

BWXT Y-12 Y-12. A BWXT/Bechtel Enterprise SMALL, PORTABLE, LIGHTWEIGHT DT NEUTRON GENERATOR FOR USE WITH NMIS

A PRELIMINARY ALIGNMENT PLAN FOR RIA AT MSU

CVD Diamond History Introduction to DDL Properties of Diamond DDL Proprietary Contact Technology Detector Applications BDD Sensors

INTRODUCTION Strained Silicon Monochromator Magnesium Housing Windows for Monochromator Shutter and Collimator Fission Detector HOPG Monochromator

PANDA-?? A New Detector for Dark Matter Search

Vacuum Chambers. Type DK /DK /DK

EYP-DFB TOC03-000x

Extrel is widely respected for the quality of mass spectrometer systems that are

NSD GRADEL FUSION NEUTRON GENERATORS

Diffraction: spreading of waves around obstacles (EM waves, matter, or sound) Interference: the interaction of waves

ORTEC Experiment 5. Energy Loss with Heavy Charged Particles (Alphas) Equipment Required. Purpose. Relevant Information

Technical description of photoelectron spectrometer Escalab 250Xi

RS 1700/1900/2300/2900 High Density Reticle Stockers

Key words: avalanche photodiode, soft X-ray detector, scintillation γ-ray detector, imaging device PACS: 07.85;95.55.A;85.60.D

HI-POWER / LED MICRO-08

Survey Meter OD-01 Address: Phone: Fax: URL:

Energetic particles and their detection in situ (particle detectors) Part II. George Gloeckler

ORTEC Experiment 7. High-Resolution Gamma-Ray Spectroscopy. Equipment Required. Purpose. Introduction

AN34 Experiments in Nuclear Science Laboratory Manual Fourth Edition

EQUIPMENT Beta spectrometer, vacuum pump, Cs-137 source, Geiger-Muller (G-M) tube, scalar

VORTEX A NEW HIGH PERFORMANCE SILICON DRIFT DETECTOR FOR XRD AND XRF APPLICATIONS

XRF books: Analytical Chemistry, Kellner/Mermet/Otto/etc. 3 rd year XRF Spectroscopy Dr. Alan Ryder (R222, Physical Chemistry) 2 lectures:

IRMS. perspective. Isotope Ratio Mass Spectrometry.

ɣ-radiochromatography

Search for a monochromatic component of solar axions using Fe-57. Toshio Namba ICEPP, University of Tokyo

High-Sensitivity Gamma-Ray Imaging With Double Sided Strip Detectors

Transcription:

ORTEC SLP Series Silicon Lithium-Drifted Planar Low-Energy Ray Detector For x-ray spectroscopy with a nuclear accelerator, radioactive source, or x-ray tube. Premium performance spectroscopy from 1 kev to 30 kev Superior resolution performance at low and high count rates Multi-detector arrays available for use at fusion facilities Thin Be window High peak-to-background ratio PopTop flexibility ORTEC SLP Series Lithium-Drifted Silicon -Ray Detectors provide the spectroscopist with a highly sensitive, premium performance research tool for detecting x rays from a nuclear accelerator, radioactive source, or x-ray tube. The energy range of detection (Fig. 1) is from 30 kev down to 1 kev, depending on the thickness of the beryllium window. The x-ray detector consists of a lithium-drifted silicon crystal and a cryogenically-cooled-fet, a high-gain, low-noise hybridized preamplifier in a PopTop capsule with a thin Be entrance window. The ORTEC Si(Li) detector crystal is manufactured under an exclusive process. Special techniques for lithium drifting result in a negligible detector element dead layer whose characteristics will not change even if the detector is stored at room temperature. The SLP Series Si(Li) detector provides exceptional resolution performance. A pulsed optical feedback preamplifier having and energy rate in excess of 4000 MeV/s* is supplied with the SLP Series detectors. An ultra-thin Be window (either 0.3 mil and 0. mil) is an option. SLP detectors have an exclusive high-rate indicator and highvoltage shutdown protection feature. If the LN 2 supply is exhausted and the detector begins to warm while high voltage is applied, the high voltage will automatically shut off, thus protecting the FET from damage. As a single element or in multiple detector arrays (Figs. 2 and 3), the SLP Series has become an important tool in soft x-ray spectroscopy in fusion research. Please contact the factory or your local sales representative for specific information on these applications. An SLP PopTop detector consists of: (a) A Si(Li) detector element (Fig. 4) mounted, in most systems, inside the vacuum enclosure of its PopTop capsule. (b) A charge-sensitive preamplifier and a HV filter, with accompanying cable pack. The first stage of the preamplifier is also mounted inside the vacuum enclosure to ensure proper cooling for optimum noise and reliability. The second stage of the preamplifier and HV filter are part of the PopTop assembly but reside outside the vacuum enclosure to which they are connected by vacuum feedthroughs. (c) A dipstick cryostat with a 30-liter LN 2 dewar or a combination cryostat-dewar assembly. Fig. 1. Detection Efficiency vs. Be Window Thickness on Low-Energy Curve and vs. Crystal Thickness on High-Energy Curve. Fig. 2. Array, Comprising Seven Tightly-Packed 6--diam Si(Li) Detectors, Used at Synchrotron Light Source. Fig. 3. Examples of Multiple Detector Arrays for Soft -Ray Spectroscopy. Note the three Be windows in each endcap. Three Si(Li) detectors share a coon cryostat in each of the systems shown. *The POF does not "lock up" or saturate at high count rates, unlike resistorfeedback designs. At ultra-high count rates with the POF, throughput is limited by reset pulse rates. 4000 MeV/s is an estimate of maximum "useable" energy rate.

Low-Energy Ray Detector The Following Specifications are Provided for Each Model SLP Detector Active crystal diameter and depth. Energy resolution at.9 kev photons from Fe at optimum shaping time unless the window material prohibits this energy. Configuration Guidelines PopTop or Streamline (non-poptop) Configuration The essence of a PopTop detector system is that the detector element, preamplifier, and high voltage filter are housed in a detector capsule which is then attached to an appropriate cryostat (Figure 4.) In so called Streamline systems, the detector capsule is NOT demountable. Detector capsule and cryostat share the same vacuum. In configuration terms, this requires a cryostat or cryostat/dewar selection with the cryostat having a matching diameter to the capsule endcap. A cryostat must always be ordered with a Streamline capsule, because they are integral. The actual PopTop capsule has its own vacuum. It can be mounted on any of the available cryostats, cryostat/dewar combinations, or the -COOLER III mechanical cooling system. Steps to Configure Your ORTEC Detector 1) Configure the Detector Model Capsule type (PopTop or Streamline) Crystal dimensions and specifications Endcap and window Mount Preamplifier High Voltage Filter Cable Package 2) Configure the Cryostat/Dewar Model Vertical Dipstick style (separate Dewar) Horizontal Dipstick style (separate Dewar) Portable with all-position or multi-position Fig. 4. Diagram of PopTop Detector. cryostat/dewar models Downlooking designed to be oriented with the detector pointing down Sidelooking designed to be oriented with the detector horizontal at the bottom of the dewar J configuration designed with the detector attached near the bottom of the dewar and a right angle bend in the cryostat orienting the detector to look up. A cryostat and dewar or other cooling device are required for operation. If a PopTop detector has been selected, you can choose a PopTop style cryostat, cryostat/dewar combination or the -COOLER III mechanical cooler. If a Streamline detector has been selected, you must choose a cryostat or cryostat/dewar model for the detector to be mounted on and vacuum sealed. The cryostat or cryostat/dewar combination diameter must match the endcap diameter of the selected detector. Defining the Detector Model Base Model (example) SLP-0616 PopTop or Streamline P (PopTop) (Streamline) 2

Low-Energy Ray Detector Streamline Detector Capsule Electronic Shroud Preamplifier default is Reset Type Collimator default is Al Preamplifier Outside Vacuum Preamplifier Front End Window default is Be High Voltage Filter Si(Li) Crystal Mount default is Cu Endcap default is Al PopTop Detector Capsule Electronic Shroud Preamplifier default is Reset Type Collimator default is Al Preamplifier Outside Vacuum Preamplifier Front End Window default is Be PopTop Cold Finger Coupling High Voltage Filter Si(Li) Crystal Mount default is Cu Endcap default is Al 3

Low-Energy Ray Detector Streamline Cryostat and Cryostat/Dewar Assemblies Streamline systems (detector capsule and cryostat) share the same vacuum, requiring a cryostat or cryostat/dewar selection with the cryostat having a matching diameter to the capsule endcap. Thermal Element Diameter must match Endcap Diameter - Diameter must match Endcap Diameter - Thermal Element Standard Dewars are DWR-7.D, 13D, or 30D Standard Cryostat uses Molecular Sieve Pumping Agent. Standard Cryostat uses Molecular Sieve Pumping Agent. Standard Dewars are DWR-1.2G, 3.0G,.0G, MOD-3L, MOD-7L or 0.7-SHP-1 Standard Cryostat uses Molecular Sieve Pumping Agent. Optional Dewars are DWR-30 and DWR-30-OP Thermal Element CFG-LP-GG CFG-LP-SV Diameter must match Endcap Diameter - CFG-LP-SD Thermal Element Diameter must match Endcap Diameter - Standard Dewars are DWR-7.B, 13B, or 30B Diameter must match Endcap Diameter - Thermal Element Standard Dewars are DWR-7.B, 13B, or 30B Standard Cryostat uses Molecular Sieve Pumping Agent. Standard Cryostat uses Molecular Sieve Pumping Agent. CFG-LP-SJ CFG-LP-SL Thermal Element Standard Cryostat uses Molecular Sieve Pumping Agent. Optional Dewars are DWR-30 and DWR-30-OP Diameter must match Endcap Diameter - CFG-LP-SH 4

Low-Energy Ray Detector PopTop and Streamline Dimensional Data Streamline systems (detector capsule and cryostat) share the same vacuum, requiring a cryostat or cryostat/dewar selection with the cryostat having a matching diameter to the capsule endcap. A cryostat must be ordered with a Streamline capsule. The PopTop capsule contains a vacuum unto itself. It can be mounted on any of the available cryostats, cryostat/dewar combinations, or the -COOLER III mechanical cooling system. The cryostat and dewar drawings that follow are to be used in conjunction with the accompanying tables of dimensions. Note: Cryostat/Dewar drawings are NOT to scale, see tables that follow for complete dimensions. CFG-LP-SJ, DWR-30B (or -13B or -7.B) CFG-PS4-30 (or -13 or -7.) or CFG-LP-SL, DWR-30B (or -13B or -7.B) CFG-LP-SV, DWR-30 CFG-PV4, DWR-30

Low-Energy Ray Detector Note: Cryostat/Dewar drawings are NOT to scale, see tables that follow for complete dimensions. CFG-LP-SH, DWR-30 CFG-LP-SH, DWR-30-OP CFG-PH4, DWR-30-OP CFG-PH4, DWR-30 6

Low-Energy Ray Detector Note: Cryostat/Dewar drawings are NOT to scale, see tables that follow for complete dimensions. CFG-PG4-1.2 (or -3 or -) or CFG-LP-GG, DWR-1.2G (or -3.0G, -.0G) CFG-PMOD4-3 (or -7) or CFG-LP-GG, DWR-MOD3L (or -MOD7L) CFG-PSHP4 or CFG-LP-GG, DWR-0.7-SHP-1 DWR-S/F CFG-PD4-30 (or -13 or -7.) or CFG-LP-SD, DWR-30D (or -13D or -7.D) 7

Low-Energy Ray Detector SLP Detector Dimensions Dimensions are for reference only and subject to change. If dimensional constraints are critical, contact the factory. Dim. Unit Tol. PopTop Streamline A B C D E F J L M N 0.3 (0.01) 0.3 (0.01) (0.2) 8 (0.3) 8 (0.3) 18 (0.7) 10 (0.4) 18 (0.7) 10 (0.4) 8 (0.3) (2.7) 7 (2.9) 13 (.3) 20 (9.8) 947 (37.3) 396 (1.6) 338 (13.3) 790 (31.1) 278 (10.9) (2.7) 7 (2.9) 71 (2.8) 182 (7.2) 84 (33.6) 30 (12.0) 318 (12.) 274 (10.8) 21 (8.) CFG--COOL-III Gaa Gage and Side-Looking Dewar Dimensions Dimensions are for reference only and subject to change. If dimensional constraints are critical, contact the factory. CFG-PG4 and DWR-x.xG Cryostat/Dewar or Dewar Type CFG-PMOD4 and DWR-MOD-xL CFG-PS4, CFG-PD4, DWR-xxB and DWR-xxD VOLUME VOLUME VOLUME Dim. UNIT TOL. ± 1.2L 3L L 3L 7L 7.L 13L 30L Q S T Y Z 13 (0.) 7.6 (0.3) (0.2) (0.2) (0.2) 229 (9.0) 17 (6.2) 229 (9.0) 302 (11.9) 229 (9.0) 267 (10.) 302 (11.9) 229 (9.0) 419 (16.) 229 (9.0) 17 (6.2) 292 (11.) 302 (11.9) 229 (9.0) 320 (12.6) 77 (3.0) 10 (0.4) 224 (8.8) 42 (17.8) 77 (3.0) 10 (0.4) 307 (12.1) 429 (16.9) 60 (2.3) 13 (0.) 442 (17.4) 610 (24.0) 8

Low-Energy Ray Detector Example Model Numbers Streamline Configuration SLP-16220 16- diameter, - deep SLP planar detector with - diameter endcap. CFG-LP-GG- Portable Gaa Gage cryostat with matching - diameter flange. DWR-1.2G 1.2 liter all-position dewar for Gaa Gage cryostat. SLP-0616 6- diameter, - deep SLP detector with - diameter endcap. CFG-LP-SD- Downlooking cryostat with matching - diameter flange. DWR-7.D 7. Liter downlooking dewar for downlooking cryostat. PopTop Configuration SLP-16220P CFG-PG-3 SLP-0616P CFG-PD4-7. 16- diameter, - deep SLP detector with - diameter endcap. Portable Gaa Gage cryostat with 3 liter all-position dewar. 6- diameter, - deep SLP detector with - diameter endcap. Downlooking cryostat with 7. liter dewar. Ordering Information For Streamline, remove the P from the model number. If dimensional considerations are critical, contact factory. OPT-0.3 = 8 µm (0.0003-in) thick Be (ultra-thin) unsupported window. OPT-0. = 13 µm (0.00-in) thick Be window. Cryostat and dewar or other cooling device are not included with detector. Cryostat and dewar or other cooling device are required for operation. A cryostat must be ordered with a Streamline detector. Model No. SLP-04160P SLP-04160P-OPT-0.3 SLP-04160P-OPT-0. SLP-0616P SLP-0616P-OPT-0. SLP-10180P SLP-16220P Active Diameter () 4 4 4 6 6 10 16 Thickness () Area ( 2 ) 12. 12. 12. 28 28 80 200 Energy Resolution FWHM (ev) @.9 kev 160 160 160 16 16 180 220 Endcap Diameter () Be Window Thickness (µm) 2 7.6 13 2 13 2 0 9

Low-Energy Ray Detector SLP PopTop Cryostats and Dewars Dewar included except where marked *. Model No. Description CFG-PD4-7. Down-looking Cryostat with 7.-liter Dewar CFG-PD4-13 Down-looking Cryostat with 13-liter Dewar CFG-PD4-30 Down-looking Cryostat with 30-liter Dewar CFG-PG4-1.2 Gaa Gage Cryostat with 1.2-liter Dewar CFG-PG4-3 Gaa Gage Cryostat with 3-liter Dewar CFG-PG4- Gaa Gage Cryostat with -liter Dewar CFG-PH4 Horizontal Cryostat (Dipstick type). Includes LNTC1.WH. Dewar not included.* Choose DWR-30 or DWR-30-OP. CFG-PMOD4-3 Gaa Gage Cryostat with 3-liter Multi-Orientation Dewar CFG-PMOD4-7 Gaa Gage Cryostat with 7-liter Multi-Orientation Dewar CFG-PS4-7. Side-Looking Cryostat with 7.-liter Dewar CFG-PS4-13 Side-Looking Cryostat with 13-liter Dewar CFG-PS4-30 Side-Looking Cryostat with 30-liter Dewar CFG-PSHP4 Down-Looking Shallow-Hole Probe with 0.7-liter Dewar CFG-PV4 Vertical Cryostat (Dipstick type). Includes LNTC1.WH. Dewar not included.* Choose DWR-30 or DWR-30-OP. DWR-30 30-liter Dewar DWR-30-OP 30-liter Offset-Port Dewar DWR-S/F Storage Fill Dewar for CFG-PG4- CFG--COOL-III-11 -COOLER III with PopTop connector using 110-120 V ac, 60 Hz Input Power CFG--COOL-III-230 -COOLER III with PopTop connector using 220-240 V ac, 0 Hz Input Power 10

Low-Energy Ray Detector SLP Streamline Cryostats Select dewar from SLP Streamline Dewars. Dewar included except where marked*. Model No. Description CFG-LP-GG- Gaa Gage Cryostat Dewar CFG-LP-SD- Down-Looking Cryostat with Dewar CFG-LP-SH- Horizontal Cryostat (Dipstick type). Includes LNTC1.2WH. Dewar not included.* CFG-LP-SJ- J-type Cryostat with Dewar CFG-LP-SL- Side-Looking Cryostat with Dewar CFG-LP-SV- Vertical Cryostat with (Dipstick type). Includes LNTC1.2WH. Dewar not included.* SLP Streamline Dewars For Cryostat Choose Description CFG-LP-GG DWR-1.2G 1.2-liter All-Orientation Dewar Included with Cryostat DWR-3.0G 3.0-liter All-Orientation Dewar Included with Cryostat DWR-.0G.0-liter All-Orientation Dewar Included with Cryostat DWR-MOD-3L 3-liter Multi-Orientation Dewar Included with Cryostat DWR-MOD-7L 7-liter Multi-Orientation Dewar Included with Cryostat DWR-0.7-SHP-1 0.7-liter Shallow-Hole Probe Dewar Included with Cryostat DWR-S/F Storage/Fill Dewar for DWR-G CFG-LP-SJ, SL DWR-7.B 7.-liter Side-Looking Dewar Included with Cryostat DWR-13B 13-liter Side-Looking Dewar Included with Cryostat DWR-30B 30-liter Side-Looking Dewar Included with Cryostat CFG-LP-SD DWR-7.D 7.-liter Down-Looking Dewar Included with Cryostat DWR-13D 13-liter Down-Looking Dewar Included with Cryostat DWR-30D 30-liter Down-Looking Dewar Included with Cryostat CFG-LP-SV, SH DWR-30-OP 30-liter Offset-Port Dewar DWR-30 30-liter Dewar 11

Low-Energy Ray Detector ORTEC www.ortec-online.com Tel. (86) 482-4411 Fax (86) 483-0396 ortec.info@ametek.com 801 South Illinois Ave., Oak Ridge, TN 37831-089 U.S.A. For International Office Locations, Visit Our Website Specifications subject to change 040413