Test Report No: (1) R1 Date: 29-Oct-10 Page 1 of 5

Similar documents
Test Report No: (1) R1 Date: 29-Apr-13 Page 1 of 5

Test Report No: (2) Date: 24-Jun-2014 Page 1 of 5

Test Report No. : KA/2010/C2116 Date : 2011/01/05 Page : 2 of 6 Test results by chemical method (Unit: mg/kg) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexa

No. KE/2016/52417 Date 2016/05/26 Page 2 of 6 Test Result(s) PART NAME No.1 Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI

The following sample(s) was/were submitted and identified by/on behalf of the client as : (2) (3) (4) (5) Please refer to next page(s).

No. CE/2012/C1503 Date 2012/12/18 Page 2 of 6 Test Result(s) PART NAME No.1 Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI

No. : CE/2012/A3090 Date : 2012/10/23 GAP PAD 1000SF RICK STEWART REPORT PER REQUEST FOR QUOTE, DATED 10/5/11

Test Report No. KD/2013/50027A-01 Date 2013/07/01 Page 2 of 6 Test Result(s) PART NAME No.1 PART NAME No.2 PART NAME No.3 Cadmium (Cd) Lead (Pb) Mercu

Test Report No. SH /CHEM Date: Oct. 22, 2009 Page 1 of 5

No. CE/2014/51910 Date 2014/05/20 Page 2 of 5 Test Result(s) PART NAME No.1 Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI

TEST REPORT Report No. : GR:HL: DATE : 27/10/2014

Test Report No. KE/2017/C1499 Date 2018/01/02 Page 2 of 7 Test Result(s) PART NAME No.1 WHITE POLYOXYMETHYLENE Test Item(s) Cadmium (Cd) Lead (Pb) Mer

Test Report No. : CE/2015/15894 Date : 2015/02/04 NIHON ALMIT CO., LTD. ALMIT BLDG., , YAYOICHO, NAKANO-KU, TOKYO, JAPAN Page : 1 of 7 *CE/2015/

TEST REPORT Report No. : GR:HL: DATE : 20/11/2014

Test Report No. : CE/2009/45866B Date : 2009/05/20 Page : 1 of 7

Test Report No. : KA/2012/40043 Date : 2012/04/10 Page : 2 of 8 Test Result(s) PART NAME NO.1 : BLACK EPOXY MOLDING COMPOUNDS Test Item (s): MDL Resul

Test Report No. CE/2016/43515 Date 2016/04/22 Page 2 of 7 Test Result(s) PART NAME No.1 AMBER FILM Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) He

Page 2 of 8 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of PBBs

CHI NHANH CONG TY TNHH SAN XUAT THUONG MAI HA PHONG -XUONG SAN XUAT

Test Report No. CE/2015/C2965A Date 2016/02/16 Page 2 of 7 Test Result(s) PART NAME No.1 MIXED ALL PARTS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item

Management number No. KA/2015/80033 Date 2015/08/10 Page 1 of 6 The following sample(s) was/were submitted and identified by/on behalf

Chemical Laboratory - Kao., SGS Taiwan Ltd. Test Report No. : KE/2017/40842 Date : 2017/04/17 ROGERS CORPORATION 245 WOODSTOCK ROAD, WOODSTOCK, CT. 06

Test Report No. CE/2017/62572 Date 2017/06/19 Page 2 of 7 Test Result(s) PART NAME No.1 PINK SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) He

Page 2 of 9 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of PBBs

Test Report No. : CE/2008/38467 Date : 2008/04/07 Page : 2 of 11 Test Result(s) PART NAME NO.1 : BLACK PLASTIC TUBE Cadmium (Cd) Lead (Pb) Mercury (Hg

Chemical Laboratory - Kao., Test Report No. : KE/2018/11379 Date : 2018/01/25 Page : 2 of 8 Test Result(s) PART NAME NO.1 : CLEAR FAL FILM WITH ADHESI

Test Report No. : KE/2016/B2076 Date : 2016/11/24 Page : 2 of 8 Test Result(s) PART NAME NO.1 : GRAY Test Item (s): Unit Method Cadmium (Cd) mg/kg Wit

Test Report No. : KA/2012/61391 Date : 2012/06/28 Page : 2 of 9 Test Result(s) PART NAME NO.1 : BLACK EPOXY MOLDING COMPOUND Test Item (s): Unit Metho

Page 2 of 9 Test Result(s) PART NAME No.1 DARK BROWN PASTE Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (2013) and pe

Test Report No. : KA/2012/41514 Date : 2012/05/07 Page : 2 of 9 Test Result(s) PART NAME NO.1 : SILVER NIPPON COPPER WIRE Cadmium (Cd) mg/kg With refe

Test Report. Report No. RLSHD Page 1 of 6

Page 2 of 11 Test Result(s) PART NAME No.1 TRANSPARENT-YELLOW PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of

Thin Film on Silicon Resistor Networks Models 2NBS, 2QSP Mold Material Change

Test Report. Report No. RLSHE Page 2 of 5 Test Result: Content 1 2

Page 2 of 10 Test Result(s) PART NAME No.1 LT.GRAY SHEET Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (2013) and perf

No. CE/2012/44922 Date 2012/05/03 Page 2 of 9 Test Result(s) PART NAME No.1 DARK BROWN LUMP Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalen

Page 2 of 12 Test Result(s) PART NAME No.1 IC TRANSCEIVER Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performed by

Test Report No. F690101/LF-CTSAYAA

Test Report No. : CE/2014/B4428 Date : 2014/12/03 Page : 1 of 12 PELNOX CO., LTD. 8-7 BODAI, HADANO CITY, KANAGAWA , JAPAN *CE/2014/B4428* The

Page 2 of 11 Test Result(s) PART NAME No.1 YELLOW/WHITE PAD (EXCLUDING THE RELEASE FILM) Cadmium (Cd) Lead (Pb) Test Item(s) Unit Method With referenc

Test Report No. CE/2014/43454A Date 2014/04/23 Page 2 of 11 Test Result(s) PART NAME No.1 MIXED ALL PARTS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Ite

Page 2 of 12 Test Result(s) PART NAME No.1 YELLOW LUMP Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs Monobro

Test Report No. CRSSA/ /17 Date : 22/02/2017 Page: 1 of 9 CRS Ref. CRSSA/17/0450/EQX

Test Report No. : CE/2009/34977 Date : 2009/03/25 Page : 1 of 10

Page 2 of 10 Test Result(s) PART NAME No.1 TRANSPARENT-YELLOW PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of

Test Report NANTONG HUADA MICROELECTRONICS GROUP CO., LTD NO.99 ZILANG ROAD,NANTONG CITY,JIANGSU PROVINCE

Page 2 of 11 Test Result(s) PART NAME No.1 COPPER/SILVER COLORED METAL SHEET (INCLUDING THE PLATING LAYER) Cadmium (Cd) Test Item(s) Unit Method With

Test Report No. CRSSA/03608/18 Date : 28/03/2018 Page: 1 of 7 CRS Ref. CRSSA/18/0736/Toray

Page 2 of 10 Test Result(s) PART NAME No.1 MIXED BLACK AND WHITE PASTE Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (

Test Report No. CTSSA/ /12 Date : 10/01/2012 Page: 1 of 5 CTS Ref. CTSSA/12/0018/Straits

Test Report No. : KA/2012/21431 Date : 2012/02/24 Page : 2 of 12 Test Result(s) PART NAME NO.1 : SILVER GRAY DIE ATTACH PASTE Test Item (s): Unit Meth

Test Report No. CRSSA/ /17 Date : 04/01/2018 Page: 1 of 5 CRS Ref. CRSSA/17/3272/Toray

Test Report No. CRSSA/25672/16 Date : 08/12/2016 Page: 1 of 9 CRS Ref. CRSSA/16/2799/Ametek

Page 2 of 12 Test Result(s) PART NAME No.1 DK. BROWN LUMP Cadmium (Cd) Lead (Pb) Mercury (Hg) Antimony (Sb) Beryllium (Be) Test Item(s) Hexavalent Chr

Test Report No. CRSSA/08508/17 Date : 12/07/2017 Page: 1 of 9 CRS Ref. CRSSA/17/1742/CSC

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs

Test Report No. CTSSA/27121/12 Date : 04/01/2013 Page: 1 of 5 CTS Ref. CTSSA/12/4387/Luvata

Technical Report No A Dated

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) ( ) Sum of

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Cadmium (Cd) Lead (Pb) Test Item(s) Unit Method With reference to IEC (2013) an

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe

Test Report No. CTSPN/ /15 Date : 26/05/2015 Page: 1 of 5 CTS Ref. CTSPN/15/0221/Toray

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe

Chemical Laboratory - Kao., Page 2 of 13 Test Result(s) PART NAME No.1 BLACK EPOXY MOLDING COMPOUND Cadmium (Cd) Test Item(s) Unit Method mg/kg With r

Test Report No. CTSSA/27080(AD)/13 Date : 03/01/2014 Page: 1 of 6 CTS Ref. CTSSA/13/3987/Toray

Test Report No Date : 27/NOV/2017 Page 1 of 5

Test Report No _rev01 Date: 06/DEC/2017 Page 1 of 5

Test Report No. CANEC Date: 01 Sep 2011 Page 1 of 8

Test Report No. : CE/2014/50660 Date : 2014/05/22 Page : 2 of 14 Test Result(s) PART NAME No.1 Cadmium (Cd) Lead (Pb) Mercury (Hg) Antimony (Sb) Test

Test Report No. CTSSA/ (AD)/13 Date: 27/11/2013 Page: 1 of 5 CTS Ref. CTSSA/13/3631/Redring

Chemical Laboratory - Kao., SGS Taiwan Ltd. Test Report No. : KA/2017/50850 Date : 2017/05/25 HERAEUS MATERIALS SINGAPORE PTE LTD BLOCK 5002, ANG MO K

Test Report No Date : 14-Feb-2018 Page 1 of 10

Test Report No. : CE/2014/32788 Date : 2014/03/27 Page : 2 of 14 Test Result(s) PART NAME No.1 : YELLOW SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Test

TEST REPORT. * Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory.

Test Report. Report No. RLSHE Page 2 of 7

ICP Test Report Certification Packet

Test Report No. : CE/2013/51536 Date : 2013/05/29 Page : 2 of 14 Test Result(s) PART NAME No.1 : YELLOW SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexa

Test Report. Report No. SCL03H Page 1 of 7

TEST REPORT Reference No. : TRHZ Date : Sep. 18, 2013 Page No. : 1 of 5

Test Report No. : KA/2014/61579 Date : 2014/07/07 Page : 2 of 14 Test Result(s) PART NAME NO.1 : GOLD BONDING WIRE Test Item (s): Unit Method Cadmium

Page : 2 of 12 Test Result(s) PART NAME No.1 : MIXED ALL PARTS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Test Item(s) Unit Method mg/kg With reference

Test Report No. CRSSA/14109/17 Date : 24/11/2017 Page: 1 of 7 CRS Ref. CRSSA/17/2961/Ametek

1. Fraction Composition Table 1 The results of XRF screening and chemical test (Unit mg/kg) HOUSING Element Data (VI) Pb/Cd/Hg / P

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 BLACK EPOXY MOLDING COMPOUND Cadmium (Cd) Test Item(s) Unit Method mg/kg With r

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 BLACK EPOXY MOLDING COMPOUND Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) H

TEST REPORT. Page : 1 of 9 Report No. RT14R-U E Date: Oct. 13, : The following submitted sample(s) said to be:-

TEST REPORT. ADDRESS : 77, Seokam-ro 13-gil, Iksan, Jeonllabuk-do, Korea PAGE: 1 of 8 REPORT NO. RT17R-U2181-E DATE: Dec. 29, 2017

Test Report KUO SEN ENTERPRISE CO.,LTD NO.87-2 NINGPAO WEST ST. TAIPEI, TAIWAN, R.O.C

TEST REPORT. : The following submitted sample(s) said to be:-

TEST REPORT : SR A-DC, SR A-DA, SR A-DT, SR A-DN, SR C-DC, SR C-DA, SR C-DT, SR C-DN

TEST REPORT. * Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory.

MSOP/QSOP/SOIC/TSSOP ICP Analysis Note

Test Report MITSUI HIGH-TEC (SHANGHAI) CO.,LTD NO.2001 XINJIN QIAO ROAD EXPORT PROCESSING ZONE PUDONG SHANGHAI CHINA

Test Report. Report No. ECL01H Page 1 of 7

TEST REPORT. : The following submitted sample(s) said to be:- SAMPLE RECEIVED : Jan. 07, 2019 TESTING DATE : Jan. 07, 2019 ~ Jan.

Test Report. Report No. ECL01I Page 1 of 7

Transcription:

Test Report No: 10213566(1) R1 Date: 29-Oct-10 Page 1 of 5 Dou Yee Enterprises (S) Pte Ltd 2304 Bedok Reservoir Road Bedok Industrial Park C (479223) THIS REPORT IS TO SUPERSEDE TEST REPORT NO.10213566(1) DATED 27-OCT-10 The following sample(s) was/were submitted and identified by/on behalf of the client as: Sample Description : CDF-30-LBL, DRY-AG-CDF051060, DRY-AG-DYE 234-S, DRY-AG-HC-MS- 20003, DRY-AG-HI051060-BC, DRY-AG-HI051060-BC-STM, DRY-AG-HI051060- xxx, DRY-AG-HI-1040, DRY-AG-HI-1060, DRY-AG-HI-123-S, DRY-AG-HI-234-S, DRY-AG-HI-345/MBB, DRY-AG-HI-51015-S, DRY-AG-HM-04, DRY-AG- MS051015, DRY-AG-MS051060(/MBB), DRY-AG-MS-123/JAR, DRY-AG-MS- 234, DRY-AG-MS234-S, DYE-051015, DYE-051015-JDE, DYE051060, DYE- 1060, DYE-10-S, DYE-CCF051060-xxx, DYE-CDF051015-LH, DYE-CDF051060-7LH(-D125), DYE-CDF051060-LH(-D125), DY-HIC-DYE-304050, DRY-AG-HC- AEC 826004 NE Sample Receiving Date : 20-Oct-10 Testing Period : 20-Oct-10 to 27-Oct-10 Test Requested : In accordance with the RoHS Directive 2002/95/EC, and its amendment directives. Test Result(s) : Please refer to next page(s). Conclusion : Based on the performed tests on submitted sample(s), the results comply with the RoHS Directive 2002/95/EC and its subsequent amendments. Signed for and on behalf of Y.C. Tham Laboratory Manager This document is issued by the Company under its General Conditions of Service accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company s findings at the time of its intervention only and within the limits of Client s instructions, if any. The Company s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and

Test Report No: 10213566(1) R1 Date: 29-Oct-10 Page 2 of 5 Test Result(s): Test Item(s): Unit Method Results MDL RoHS Limit Cadmium(Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium (CrVI) Sum of PBBs Monobromobiphenyl Dibromobiphenyl Tribromobiphenyl Tetrabromobiphenyl Hexabromobiphenyl Pentabromobiphenyl Heptabromobiphenyl Octabromobiphenyl Nonabromobiphenyl Decabromobiphenyl Sum of PBDEs Monobromodiphenyl ether Dibromodiphenyl ether Tribromodiphenyl ether Tetrabromodiphenyl ether Pentabromodiphenyl ether Hexabromodiphenyl ether Heptabromodiphenyl ether Octabromodiphenyl ether Nonabromodiphenyl ether Decabromodiphenyl ether ## mg/kg With reference to IEC62321, n.d. 2 100 performed by UV/Vis Spectrometry mg/kg n.d. - 1000 With reference to IEC62321, mg/kg n.d. - 1000 performed by GC/MS

Test Report No: 10213566(1) R1 Date: 29-Oct-10 Page 3 of 5 Note: (1) mg/kg = ppm ; 0.1wt% = 1000ppm (2) n.d.= Not Detected (3) MDL = Method Detection Limit (4) ## = The exemption of DecaBDE in polymeric application according 2005/717/EC was overruled by the European Court of Justice by its decision of 01.04.2008. Subsequently DecaBDE will be included in the sum of PBDE after 01.07.2008. (5) - = Not regulated (6) * : Exceeds limit Remarks: Sample received was totally dissolved by preconditioning method. Lab Analyst(s): Jay, Jojo and Eileen Sample photo: Sample Description : CDF-30-LBL, DRY-AG-CDF051060, DRY-AG-DYE 234-S, DRY-AG-HC-MS- 20003, DRY-AG-HI051060-BC, DRY-AG-HI051060-BC-STM, DRY-AG- HI051060-xxx, DRY-AG-HI-1040, DRY-AG-HI-1060, DRY-AG-HI-123-S, DRY-AG-HI-234-S, DRY-AG-HI-345/MBB, DRY-AG-HI-51015-S, DRY-AG- HM-04, DRY-AG-MS051015, DRY-AG-MS051060(/MBB), DRY-AG-MS- 123/JAR, DRY-AG-MS-234, DRY-AG-MS234-S, DYE-051015, DYE-051015- JDE, DYE051060, DYE-1060, DYE-10-S, DYE-CCF051060-xxx, DYE- CDF051015-LH, DYE-CDF051060-7LH(-D125), DYE-CDF051060-LH(- D125), DY-HIC-DYE-304050, DRY-AG-HC-AEC 826004 NE SGS authenticate the photo on original report only

Test Report No: 10213566(1) R1 Date: 29-Oct-10 Page 4 of 5 Process Flow of IEC 62321 (Pb, Cd, Hg & Cr 6+ ) Cutting / Preparation Sample Measurement Pb,Cd Acid digestion by suitable acid depended on different sample material Filtration Hg Microwave digestion with HNO3/HCl/HF Cr (Vl) Add appropriate amount of digestion reagent Heat to appropriate temperature to extract Solution Residue Cool, filter digestate through filter ICP-AES 1)Alkali Fusion 2)HCl to dissolve Add diphenyl-carbazide for color development Measure the absorbance at 540 nm by UV-VIS Remarks: Sample received was totally dissolved by preconditioning method. (CrVl method excluded)

Test Report No: 10213566(1) R1 Date: 29-Oct-10 Page 5 of 5 Process Flow of PBBs and PBDEs by GC/MS (IEC 62321) First Testing Process Optional screen process Confirmation process... Cutting/Preparation Sample Pre-treatment Screening Analysis Solvent Extraction Concentrate/Dilute extracted solution Filter High Mass Range GC/MS Data ***End of Report***