Key Features of Targeted Metabolite Screening. Using the TripleTOF System, an Accurate Mass Metabolite Spectral Library and MasterView Software

Similar documents
Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

Analyst Software. Peptide and Protein Quantitation Tutorial

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

NEW TOOLS FOR FINDING AND IDENTIFYING METABOLITES IN A METABOLOMICS WORKFLOW

MassHunter TOF/QTOF Users Meeting

Powerful Scan Modes of QTRAP System Technology

MassHunter Software Overview

Quantitative Analysis and Identification of Migrants in Food Packaging Using LC-MS/MS

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Food & Environmental. Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou SCIEX, Concord, Ontario, Canada

Information Dependent Acquisition (IDA) 1

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Metabolomics Batch Data Analysis Workflow to Characterize Differential Metabolites in Bacteria

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

Overview. Introduction

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Accelerated Impurity Profiling Workflow for Bulk Drugs and Formulations using an Accurate Mass Workhorse

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

The Quantitation and Identification of Coccidiostats in Food by LC-MS/MS using the AB SCIEX 4000 Q TRAP System

Analyst Software. Automatic Optimization Tutorial

Nontarget Analysis via LC-QTOF-MS to Assess the Release of Organic Substances from Polyurethane Coating

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou AB SCIEX, Concord, Ontario, Canada

Compounding insights Thermo Scientific Compound Discoverer Software

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Making Sense of Differences in LCMS Data: Integrated Tools

Chemical Labeling Strategy for Generation of Internal Standards for Targeted Quantitative Proteomics

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Agilent MassHunter Quantitative Data Analysis

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

High-sensitivity, high-throughput quantitation of catecholamine metabolites in urine by LC/MS/MS for clinical research

Agilent All Ions MS/MS

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Untargeted Screening on the X500R QTOF

Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS

WADA Technical Document TD2003IDCR

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Agilent MassHunter Quantitative Data Analysis

Chemical Components Identification of Cistanche Deserticola Using the X500R QTOF System

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Application Note. Edgar Naegele. Abstract

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

A Q-TOF Generated, Metabolomics- Specifi c LC/MS/MS Library Facilitates Identifi cation of Metabolites in Malaria Infected Erythrocytes

Analysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method

Improved Automated Sample Preparation for the Analysis of 25-OH-Vitamin D3 by LC/MS/MS

A Sensitive and Reproducible Signature Peptide MRM Based Quantitation Method for Pegylated Interferon α-2b in Serum

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Metabolomics in an Identity Crisis? Am I a Feature or a Compound? The world leader in serving science

Analysis and Quantification of Mycotoxins in Cereals Using MRM HR on the SCIEX X500R QTOF System with SCIEX OS

Multi-residue analysis of pesticides by GC-HRMS

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Computer-assisted analysis of complex natural product extracts

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

Quantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

Extend Your Metabolomics Insight!

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

Routine MS Detection for USP Chromatographic Methods

Application Note. Authors. Abstract. Introduction. Environmental

A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Automated and accurate component detection using reference mass spectra

Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

Application Note. David A. Weil Zoltan Timar Michael Zumwalt Edgar Naegele. Abstract

UNIFI - Targeted and Untargeted Screening MS Software

Tecan AC Extraction Plate

MetWorks Metabolite Identification Software

Stephen McDonald and Mark D. Wrona Waters Corporation, Milford, MA, USA INT RO DU C T ION. Batch-from-Structure Analysis WAT E R S SO LU T IONS

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate Yu 3

LC MS analysis of metabolites. Basis of Chromatography

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Transcription:

RUO-MKT-02-2201-A Automated Targeted Screening of Hundreds of Metabolites Using the TripleTOF System, an Accurate Mass Metabolite Spectral Library and MasterView Software Baljit K. Ubhi 1, Eva Duchoslav 2, Lyle Burton 2, Tobias Bruderer 3, Emmanuel Varesio 3 and Gerard Hopfgartner 3 1 SCIEX, USA, 2 SCIEX, Canada and 3 University of Geneva, Switzerland There are two main approaches used in the field of discovery metabolomics today: the untargeted, discovery route to cover a broad range of metabolites and the targeted route whereby one interrogates for a set of known metabolites to quickly generate quantitative results. LC/MS is essential for metabolomics workflows because of its versatility, soft ionization and coverage of metabolites 1 as well as being amenable to automation and high throughput. As the field of metabolomics has rapidly evolved so has the technology, and these advancements have allowed for more powerful data acquisition strategies. The powerful data dependent workflow of the TripleTOF system means that the user can collect high resolution, accurate mass MS and MS/MS data in a single injection. Once the data has been collected in an unbiased way (untargeted analyses), one can now search the data either using a targeted approach for known metabolites, or metabolites pertaining to a specific pathway or classes known as targeted metabolite screening. Or one can search the data more broadly looking for unknowns in an untargeted fashion known as untargeted metabolite screening. As LC/MS data from any discovery metabolomics study can be information rich and quite complex, powerful software tools are needed to extract the relevant information for identification with high confidence. Here, we present a streamlined targeted workflow using the single injection workflow on SCIEX TripleTOF 5600+ and Systems followed by data processing using MasterView software with a high resolution, accurate mass metabolite spectral library (Figure 1). This metabolite library contains over 500 metabolites across a variety of pathways such as TCA cycle, BCAA degradation/synthesis, glycolysis, urea cycle, and across many compounds classes such as amino acids, bile acids, sugars, nucleotides, organic acids including many natural and non-natural products (including common drugs). Key Features of Targeted Metabolite Screening Fast acquisition of high resolution, accurate mass MS and MS/MS data on the TripleTOF System enables a single injection data acquisition strategy Easy to use, targeted data processing using MasterView Software enables data to answers in 5 clicks Accurate mass metabolite spectral library contains over 500 compounds from most studied biochemical pathways and compound classes across many species/organisms Compound identification with high confidence based on automatic evaluation of: Figure 1. Targeted Metabolite Workflow using the TripleTOF System. Collect data using an untargeted approach and process the data using the accurate mass metabolite spectral library. Any metabolite identification is done upfront and confirmed using MS1, RT, isotope pattern and MS2 criteria. Then data can be transitioned for statistical analyses, quantitation and/or reporting. Retention time, mass accuracy, isotope pattern and MS/MS Reduce data review time, get to biological answers faster Easy transition to quantitation & reporting p 1

Materials and Methods The accurate mass metabolite spectral library 2 contains a library of high resolution, accurate mass MS and MS/MS spectra. The library contains retention time information and all details required to collect the sample data are outlined in Experimental Conditions document. This document contains the LC and MS parameters needed to collect the data as well as solvent and column conditions. The workflow for collecting the data and processing for metabolite identification is shown in Figure 2. The data can then be easily transitioned to MarkerView for statistical analysis or MultiQuant for quantitative analysis such as generating calibration curves and reviewing data integration. Chemicals: The following standards were used for testing in positive mode analysis: Creatinine, Dimethylglycine, Hippuric acid,,, Acetylputrescine, Glucose-1-Phosphate, Xanthosine, Taurine and 1- Methylhistidine. For negative mode analysis the following standards were used: Estradiol, Levofloxacin, Lathosterol, Quercetin, Suberic acid,,, Nicotinic acid, Phenylephrine and Omeprazole. Individual stock solutions of each standard were made up at 1 mg/ml. Sample Preparation: Stock mixtures were diluted and calibrations curves were generated from 0 ng/ml to 1 ng/ml mixtures. Urine in Eppendorf tubes was centrifuged for 15 minutes at 20,000 rcf (relative centrifugal force) to remove the major particulates to the bottom of the tube. An aliquot of urine was diluted with 3 parts water. Each urine sample was spiked with the appropriate standard mixture to create a final concentration in the urine to be 0,, 10 and 1 ng/ml. A sample of urine was diluted in 3 parts water to use as a blank. All samples were stored at 20 C until ready for injection. Liquid Chromatography: A Shimadzu Prominence LC system was operated at a flow rate of 300 µl/min using acidic or basic conditions for the chromatography (Table 1). Mobile Phase A: 5mM ammonium formate in 1% methanol, adjusted to ph = 3 with formic acid. Mobile Phase B: Methanol. Mobile Phase C: 5mM ammonium formate in 1% methanol, adjusted to ph = 8 with ammonium hydroxide. An Acquity XSelect HSS T3 column (2.1 x 150 mm, 2.5 µm ID, Waters) was used which retains both polar and non-polar compounds. Sample and standard mixture injections were made at 1 µl in triplicate to obtain reproducibility data across compounds investigated. Table 1. Shimadzu LC Method for Both the Acidic and Basic Separation Conditions. Step Total Time (min) Module Event Parameter (%) 1 1.00 Pumps Pump B Conc. 0 2 21.00 Pumps Pump B Conc. 3 25.00 Pumps Pump B Conc. 4 25.01 Pumps Pump B Conc. 0 5 28.00 Controller Stop 0 Note: For acidic LC conditions use mobile phase A, for basic conditions use mobile phase C. Mobile phase B always stays the same. Mass Spectrometry: Data was collected in IDA mode on the TripleTOF 5600+ and Systems using a DuoSpray Source. The mass range used for data acquisition was 50-800 m/z for MS and 40-800 m/z for MS/MS. Mass Spectrometry settings are shown in Table 2 below: Table 2. TripleTOF System Acquisition Parameters. Positive polarity: Source/Gas Parameters CUR: 25 psi IS: 5500 V TEM: 500 C GS1: 50 psi GS2: 60 psi CAD: High Compound Parameters: DP: 80 V CE: 35 V CES: 20V IDA criteria: Negative polarity: Select 1 to 8 most intense peaks Which exceeds: 300 cps Exclude former target ions: Always After number of Occurrences: 3 For: 3 seconds Dynamic Background Subtraction: ON Source/Gas Parameters CUR: 25 psi IS: -4500 V TEM: 500 C GS1: 50 psi GS2: 60 psi CAD: High Compound Parameters DP: -80 V CE: -45 V CES: -25V p 2

Value of the Metabolite Library The high resolution accurate mass metabolite spectral library contains 536 metabolites which are found across various biochemical pathways, compound classes and across many species. The library contains compounds from the following classes: Amino acids Bile acids Nucleotides Nucleosides Carboxylic acids Sugars Catecholamines Organic acids Polyamines Simple lipids Steroids Vitamins Common drugs Common plant metabolites Workflow for Targeted Metabolite Screening using MasterView Software Extracted Ion Chromatograms (XICs) are generated for all metabolites in the library, based on thresholds set by the user such as formula and expected retention time of all target analytes. The MS and MS/MS information is automatically evaluated if the detected XIC signal exceeds the user defined intensity threshold or signal-to-noise (S/N) (Figure 3). Data processing results are ranked based on 4 selectivity criteria, to provide a high degree of confidence in assigning compound identifications to detected compounds: Retention time matching Mass accuracy Isotope pattern fit MS/MS library searching In addition, the intensity can be compared to a standard sample of known concentration to obtain quantitative information. The library was collected in collaboration with Professor Gerard Hopfgartner at the University of Geneva and his team. The spectra were transferred to SCIEX and the library was built in the LibraryView Software framework. In order to run the library, the MasterView Software add-on to PeakView Software is required. The workflow for targeted metabolite screening using the TripleTOF is highlighted in Figure 2. From the total ion chromatogram for a data dependent experiment, the subsequent extracted ion chromatograms can be mined. Both accurate mass of the parent and from the MS/MS are used to identify and then confirm a metabolite. Acquired Dataset Statistical analysis in XCMS plus Software ID/Quant in MasterView Software ID in XCMS plus Statistical analysis in MarkerView Software Untargeted Metabolite Screening Targeted Metabolite Screening Figure 2. Targeted Metabolite Screening Workflow using the TripleTOF System. Using the approach on the right hand side: 1) Process the data using MasterView Software and the accurate mass metabolite to identify any metabolites in your data. 2) Transition the data to MarkerView Software for statistical analysis of the identified metabolites. Figure 3. Data Dependent Acquisition of High Resolution MS and MS/MS Data for Identification and Quantification of Metabolites. The top trace shows the sum TIC of the full scan (in blue) and the MS/MS triggered during the IDA experiment (in pink). A compound is identified based on 4 criteria. The first two criteria are retention time and mass accuracy - the middle trace shows an extracted ion chromatogram (XIC) and the match to the retention time to the library compound. Second is mass accuracy and isotope pattern match, the plots on the bottom left highlights the match based on MS1 isotope pattern to the spectral library. The plot to the right highlights the match based on MS2 fragmentation pattern. p 3

Figure 4. Confidence Settings in MasterView TM Software. Criteria used to pass, review or fail a parameter for metabolite identification and confirmation. A score is then calculated for the metabolite from your sample. A combined score can also be generated based on weighting to all parameters. The confidence settings (Figure 4) can be set to define to the criteria which allows for matching the acquired data with either theoretical / library spectra. The criteria can be set for mass accuracy, retention, isotope pattern and MSMS library matching. Once the data are processed, one can review the results using the traffic lights display as well as the MS and MS/MS spectra with library matches (Figure 5). The results can then be directly reported from the templates available in MasterView software. Or the data can be transitioned for further processing in MultiQuant Software for more in depth quantitative analysis (Figure 6). Save your results with highest confidence as a MQ file by selecting the MQ icon from the toolbar. Import this file in MultiQuant Software as a quantitation method from text for generating any calibration curves and to review peak integration parameters. Figure 6. Transition for Quantitation and Report to MultiQuant TM Software. Generate automatically calibration curves for quantitation without having to build long quantitation methods manually. The most powerful workflow is to be able to take the identifications found and transition this data for statistical analysis to MarkerView Software (Figure 7). The table can be saved as an MV file by selecting the MV icon from the tool bar. Open this file in MV as a generic text file and continue any statistical data analysis. Any principal component analyses can be generated as wells as t-tests and p values. The power here is that every peak in the loading plot has a name as it has been confidently identified from the accurate mass metabolite spectral library in MasterView Software. This drives the biological hypothesis faster than having to now complete an identification step. Figure 5. Review Data in MasterView TM Software. The data can now be reviewed and any matches against the database can be evaluated. The traffic light system allows easy review and a user can filter compounds identified with highest confidence by selecting all the green rows meaning these compounds passed the confidence settings set in Figure 4. Figure 7. Transition for Statistical Analysis to MarkerView TM Software. Generate any principal component analysis and drive your biological interpretation faster as results in the loadings plot (center right) are already identified. Combine with t-test analysis and rank your significantly differential metabolites by p-value. p 4

Employ the comparative screening tool in MasterView Software to compare all your samples versus a control. After loading your samples into MasterView software, specify the control as well as the sample. Metabolites meeting the acceptance criteria as well as threshold (set by the user for comparative results) are indicated as green rows. The threshold can be a factor, i.e. 2 times or 10 times or can be set in terms of intensity and cps (counts per second). This is a quick way to take a snapshot of what is changing on a per sample basis. Although it is not true metabolomics where all samples are compared together, a user can use to screen and quickly capture any major changes compared to a control/baseline sample. Validation of Library Compounds in a Biological Matrix A subset of compounds from the total library of compounds was used to analyze metabolites present in a complex biological matrix. Compounds were spiked in at varying concentrations into a diluted urine sample and measured on both the TripleTOF 5600+ and Systems. Data was collected in both positive and negative ionization modes as well as at acidic and basic conditions. The IDA results are listed in Table 3. Conclusions A new high resolution accurate mass metabolite spectral library was used to verify spiked compounds in a urine matrix and confirm their scoring against MSMS spectra in MasterView TM software. Data collected using the single injection approach with IDA means that high resolution MS and MSMS data are collected simultaneously. For complete metabolite coverage samples should be acquired in both positive and negative ionization modes and at both acidic and basic conditions. The acquired data can then be reviewed using the traffic light system in MasterView Software and then be easily transitioned for reporting, quantitation and statistical data analysis can be acquired simultaneously. The library was validated on both the TripleTOF 5600+ and Systems. References 1. Zhou B, Xiao JF, Tuli L, Ressom HW. LC-MS-based Metabolomics. Molecular Biosystems, 2012 Feb8(2):470-81 2. Available via the purchase of a DVD and license; PN 5036817 or through web download and purchase of a license; PN 5037185. 3. Technical application note from EFAB team: http://sciex.com/documents/brochures/masterview_targete d_screening_7830413.pdf 4. MasterView targeted screening video: http://sciex.com/masterview-software-screen-for-targetedcompounds-in-your-unknown-samples 5. MasterView Processing and Review Video: http://sciex.com/masterview-software-easy-set-up-of-dataprocessing-and-data-review-parameters Figure 8. Comparative Screening in MasterView TM Software. A sample is compared to a set control/baseline sample. This can be a healthy/wild-type or blank sample. Setting a threshold means any metabolite highlighted as a green row has passed the acceptance criteria. This quickly gives the user a snapshot of any major changes in metabolite concentrations between their samples. Note this is on a per sample basis. p 5

Compound Instrument ph Polarity MSMS Purity (%) ID Comment Xanthosine Suberic acid Nicotinic acid Omeprazole Suberic acid Omeprazole 94.8 95.9 99.3 97.3 99.7 60.3 / 94.3 97.2 88.3 81.0 94.8 95.8 99.5 80.2 80.3 98.3 96.3 99.8 99.4 94.5 97.4 67.1 94.6 99.7 81.0 NA 77.5 94.7 81.7 NA 97.4 Xanthosine Xanthosine Suberic acid Suberic acid Nicotinic acid Nicotinic acid Omeprazole Omeprazole - Suberic acid - Omeprazole Isotope interference No acquired MSMS No MSMS acquired 2015 AB Sciex. For Research Use Only. Not for use in diagnostic procedures. The trademarks mentioned herein are the property of AB Sciex Pte. Ltd. or their respective owners. AB SCIEX is being used under license. Document number: RUO-MKT-02-2201-A p 6