Couplings / Gas Analysis

Similar documents
TGA Thermal Gravimetric Analysis

THERMO- GRAVIMETRIC ANALYZER TGA 1000

High Pressure DSC Differential Scanning Calorimeter

DSC PT 10. Applications

HYPHENATED TECHNOLOGY GUIDE

Evolved gas analysis by simultaneous thermogravimetric differential thermal analysis-fourier transformation infrared spectroscopy (TG-DTA-FTIR)

Technical know-how in thermal analysis measurement

HYPHENATED TECHNOLOGY GUIDE

SIMULTANEOUS THERMAL ANALYSIS STA PT 1000 STA PT 1600 STA HP

It is the purpose of this paper to demonstrate that the detection limit is directly related to the sample size, for both TG and TG/FTIR.

The Claviature of Gas Analysis

Thermal Methods of Analysis Theory, General Techniques and Applications. Prof. Tarek A. Fayed

Thermogravimetric Analysis Advanced Techniques for Better Materials Characterisation

APPLICATION NOTE. Investigation of Alkali Salts with the STA 449 F5 Jupiter. Dr. Alexander Schindler and Dr. Michael Schöneich.

Nutshells of Thermal Analysis. Heat it up! Burn it! Thermal Analysis

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Thermal Analysis Mass Spectrometer Coupling. Evolved Gas Analysis Method, Techniques and Applications

LASER FLASH ANALYSIS LFA 1000

Fragrances Sampling and Analysis

LIGHT FLASH ANALYSIS LFA 500

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

TANDEM MASS SPECTROSCOPY

Chemistry Instrumental Analysis Lecture 34. Chem 4631

Hiden Isochema. Gravimetric Gas & Vapor Sorption Analyzers. Hiden Isochema IGA Series. Advancing Sorption Analysis

CHEM*3440. Thermal Methods. Thermogravimetry. Instrumental Components. Chemical Instrumentation. Thermal Analysis. Topic 14

ADVANCED ANALYTICAL LABORATORY

Research Equipment in the UCA Chemistry Department

Gas Chromatography. Chromatography Laboratory Course. Dr. Christian Jungnickel Chromatography Course GC September 2005

Thermal methods. P A Sathe Ramnarain Ruia College, Mumbai

High Pressure/Performance Liquid Chromatography (HPLC)

Thermal Methods of Analysis

Analyzing & Testing. Thermogravimetric Analysis TGA. Technique, Instrument, Applications TG 209 F1. Leading Thermal Analysis

Tips & Tricks GPC/SEC: Quantify and Get More Than Molar Mass Averages

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Total analysis with DSC, TMA and TGA-EGA

Gas Chromatography (GC)

Uncover the insight with Hyphenation. Gerlinde Wita October 2015

Benchtop NMR Combined with GC/MS Confirms Identity of Forensic Case Sample

Secondary Ion Mass Spectrometry (SIMS)

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

2401 Gas (liquid) Chromatography

Introduction to Pharmaceutical Chemical Analysis

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Luminescence transitions. Fluorescence spectroscopy

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

Chapter 27: Gas Chromatography

Questions on Instrumental Methods of Analysis

Techniques useful in biodegradation tracking and biodegradable polymers characterization

MS/MS .LQGVRI0606([SHULPHQWV

Propose a structure for an alcohol, C4H10O, that has the following

High-pressure qnmr spectroscopy in condensed- and gas-phase towards determination of impurities and compositions of gas mixtures

3) In CE separation is based on what two properties of the solutes? (3 pts)

Introduction to GC/MS

Analyzing & Testing. Photocalorimetry Photo-DSC. Method, Technique, Applications. Photo-DSC 204 F1. Leading Thermal Analysis

CHAPTER A2 LASER DESORPTION IONIZATION AND MALDI

CHEM 3590 Final examination 2017 Instructor : Dr. Hélène Perreault Monday December 11, 1:30-4:30 pm, Frank Kennedy Gold Gym seats

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Far UV Absorbance Detector

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

Introduction to Fourier Transform Infrared Spectroscopy

FTIR Spectrometer. Basic Theory of Infrared Spectrometer. FTIR Spectrometer. FTIR Accessories

Atomic Emission Spectroscopy

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

Hiden CATLAB Systems Microreactor for Catalysis Studies & Thermal Analysis

Ch 313 FINAL EXAM OUTLINE Spring 2010

Chromatography & instrumentation in Organic Chemistry

Welcome to Organic Chemistry II

Period of validity: to date of issue:

Catalysis CAPABILITIES

Hyphenated micro-ta techniques

Ionization Techniques Part IV

Science Drivers. Spectroscopic Sensors. In Situ Sensors. Development of autonomous and remote platforms

Prima PRO Process Mass Spectrometer

Advanced Spectroscopy Laboratory

Permanent Gas Analysis by Gas Chromatography Vacuum Ultraviolet Spectroscopy

高等食品分析 (Advanced Food Analysis) I. SPECTROSCOPIC METHODS *Instrumental methods: 1. Spectroscopic methods (spectroscopy): a) Electromagnetic radiation


Glove Box / BRAUN MB 150B-G

Gaseous CEMS technology

LC-MS Based Metabolomics

CHAPTER 6 GAS CHROMATOGRAPHY

novaa 800 D Atomic Absorption Spectrometer

Secondary Ion Mass Spectroscopy (SIMS)

4. How can fragmentation be useful in identifying compounds? Permits identification of branching not observed in soft ionization.

Emission spectrum of H

Introduction to Fourier Transform Infrared Spectroscopy

Characterization of petroleum samples via thermal analysis coupled to APCI FTMS

Lecture 8: Mass Spectrometry

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Complete Materials Deformulation Using TGA-IR

ATOMIC ABSORPTION SPECTROSCOPY (AAS) is an analytical technique that measures the concentrations of elements. It makes use of the absorption of light

Analytical techniques: Environmental samples. Lecture 2 Universidade do Algarve

Lecture 8: Mass Spectrometry

Mass Spectrometry in MCAL

Analysis of Polar Metabolites using Mass Spectrometry

Collected Applications Thermal Analysis EVOLVED GAS ANALYSIS

Chromatography. Gas Chromatography

Final Report. Characterisation of Sample Report. Job No 2016/11/12-34 AS No. 1234A. Client Example Contact Sample. Signed Date 2017.

Atomization. In Flame Emission

Transcription:

Couplings / Gas Analysis

General With the coupling of a thermal balance and a gas analyzer like a FTIR spectrometer (Fourier Transform Infrared) or a Quadrupole-Mass-Spectrometer a very powerful analytical instrumentation is used which gives information from the thermal balance (TGA) or simultaneous thermal analyzer (STA) as well as from the spectrometer simultaneously. The optional Pulse-Analysis injects an exactly predetermined amount of gas into the Thermobalance (TGA) or Simultaneous Thermal Analyzer (STA). This enhances the measurement possibilities significantly. Analytical techniques used for coupling with thermal analyzers Couplings can be done with different gas analyzing methods: FT-IR spectroscopy Quadrupol mass spectrometry (QMS) ELIF spectroscopy (Excimer Laser Induced Fragmentation Fluorescence) Gas chromatography Typical coulings for simultaneous measurements are: TG-DSC-MS (Thermogravimetry, Differential Scanning Calorimetry, mass spectrometer) TG-MS (Thermal balance coupled with mass spectrometer) TG-DSC-GC/MS (Thermogravimety, Differential Scanning Calorimetry, Gas Chromatography / Mass Spectrometry) TG-FTIR (Thermal balance coupled with FTIR spectrometer) Infrared spectroscopy : Infrared light can excite molecular vibrations in molecules. In order to be active in respect to IR-spectroscopy, the molecule has to change its dipolar momentum during excitation. Gases like CO 2, CO, hydrocarbons, water vapour etc. have IR-active vibration modes while N 2, O 2 etc. cannot be detected. The obtained IR-spectra allow identification of the components by cha- 2

racteristic vibrations which are either typical for a certain functional group (CO, COOR etc.) or for a particular compound (so called fingerprint-region of the spectra from 15 5cm -1 ). Spectra libraries are helpful during spectra interpretation. Coupling to TGA and STA is a valuable tool especially in analysis of organic compounds (polymers etc.). Mass spectroscopy: Mass spectroscopy sorts molecules by their molecular weight divided by their electrical charge (m/e). In quadrupol mass spectroscopy (QMS) molecules enter a magnetic quadrupolfield after having been accelerated in a static electric field. Molecules and their fragments are sorted by their masses and can be identified. Mass spectroscopy is very useful in order to find the molecular weight of the outgassing as well as to analyse gases which are not active in IR-spectroscopy (N 2,O 2, CO etc.). Using mass spectroscopy, nearly all molecules can be detected. Also the resulting fragments of bigger molecules are often characteristic for several compounds or functional groups. This method is a common used analytical method that can be found in polymer or organic analysis as well as in forensic, medicinal, biological or inorganic areas like material science. Mass spectrometry can be also combined with a GC method that is used to get information about the purity of the substances that are investigated by the mass spectrometer. So the resulting method called GC-MS gives both, purity and molecular weight of the substrate. ELIF spectroscopy: ELIF (Excimer Laser Induced Fragmentation Fluorescence) is a technique used for analysis of alkali metal compounds. Its measuring principle is based on a simultaneous cleavage of molecules, and excitation of the respective alkali atom by a VUV-laser. After the return of the agitated atom to its original state, a photon of a characteristic wavelength is emitted. The intensity of this fluorescent signal is a measure of the concentration of the compound in question. This technique is a valuable tool for characterization of alkali metal compounds (NaCl, KCl, NaOH, etc.). ELIF spectroscopy can be used only by optical in-situ coupling (see below). Gas chromatography The evolved gases can be a complex mixture of compounds. Column Chromatography separates these compounds before analysing them by different techniques. The chromatographic separation column has to be chosen according to the type of molecules to be separated (polar or unpolar). The most frequently used detection techniques are flame ionization detectors (FID) and thermal conductivity detectors (TCD). Type of couplings The coupling of the thermal analyser with the spectrometer/chromatograph can be done by different means: Heated transfer capillary (FTIR, GCMS, GC, MS) Sniffer coupling (GCMS, GC, MS) Optical in-situ observation (ELIF) Heated transfer capillary The simplest way to do a coupling is by heated capillary. In this case, a heated capillary feeds the evolved gazes from the thermobalance to the spectrometer or chromatograph. The internal diameter of a capillary is <,1 mm in case of a MS coupling. The capillary is heated to 2-3 C which results in the risk of condensation of outgassing during transfer and clogging of the capillary. Sniffer coupling This technique is used for mass spectrometer coupling. Gases pass through a very small orifice close to the sample inside the furnace and are transferred in the vacuum line to the mass spectrometer. In this way, gases are sampled at high concentration very close to the sample at high temperature and pass directly to ultra-high vacuum. This technique avoids any risk of condensationduring transfer between the thermobalance and the mass spectrometer. Optical in-situ observation In this case, optical windows are integrated in the thermobalance s During heating samples often undergo phase transitions and/or weight change due to evaporation of solvents and/or chemical reactions. These changes can be detected by thermal analysis: calorimetric techniques (DTA and DSC) give information about the heat involved in these processes and thermogravimetry (TG) shows the weight change. Weight change can be either weight increase due to oxidation reactions or weight loss due to decomposition by liberation of volatile compounds. Analysis of these evolved gases can give valuable information about the sample composition and reaction pathways for decomposition. As thermal analysis gives no information about the nature of the evolved gases, coupling with spectrometers or chromatographs is a valuable tool for evolved gas analysis (EGA). 3

QMS Mass spectrometry (MS) is an analytical technique to measure the mass of atoms or molecules of a gas e.g. evaporated from a sample material which has been heated up. The spectra are used to determine the elemental or isotopic signature of a sample, the masses of particles and of molecules, and to elucidate the chemical structures of molecules, such as peptides and other chemical compounds. Mass spectrometry works by ionizing chemical compounds to generate charged molecules or molecule fragments and measuring their mass-to-charge ratios. The QMS - quadrupole mass spectrometer coupling device is a state of the art mass spectrometer with a heated inlet system. The QMS is used for the analysis of volatile decompositions. All LINSEIS instruments are especially designed to guarantee a user friendly operation of both the thermal analyzer and the mass spectrometer. An integrated Software solution is certainly available. Example System: Coupling of thermo balance TG/STA + Quadrupol Mass-spectrometer(QMS): Both manufacturers LINSEIS and Pfeiffer are some of the leading companies in their specialized fields. This cooperation guarantees outstanding performance for the combined system. Transfer line is temperature controlled up to a maximum of 25 C. Fast response time through short transfer line MS detector with very high sensitivity and with different mass numbers available. The following applications can be measured: Outgasing components of burned material (paints etc.) Determination of blenders and additives Absorption and Desorption processes Analysis of rubbers and plastics Features LINSEIS Research balance (different models) with TG or simultaneous TG/DSC or TG/DTA measurement Simultaneous balance with (.1/.5/1µg) resolution and 25g max. sample weight Specific heat measurements (Cp) possible Pfeiffer/Balzers mass spectrometer model Thermostar ( - 1 amu, - 2 amu, - 3 amu) Highest precision Quadrupol-MS from world leader in MS Technology MS with very compact dimensions Very easily exchangeable quartz capillary Three separate heating zones, at capillary, at TG protection tube and at MS vacuum inlet Carrier gas with wide range of flow rates Especially developed Al 2 O 3 sniffer-nose, to extract the outgasings Combined results of TG and MS available in one evaluation sheet Complete vacuum tight system 4

Cement raw material TG [%] 1 9 8 7 6 5-1.97% -.84% -3.32% -1.4% -1.22% 129.5 C -458.57 J/g 438.9 C 485.2 C 1419.56 J/g 53.75 J/g 333.4 C amu 18 (H 2O) amu 57 (C 4H 9) amu 44 (CO 2) amu 58 (C 4H 1) amu 64 (SO 2) amu 67 (C 5H 7) amu 78 (C 5H 6) 819.7 C -33.69% 1227.8 C 39.17 J/g exo 1351.1 C -4.22% 5-5 -1 DSC [mw/mg] [3] 1.4 1.2 1..8.6.4.2 The combination of thermal analysis with mass spectroscopy is a very powerful method to identify and quantify the components of the raw material and it is also a tool for the simulation of the manufacturing process of building materials. The components of cement raw material are: mixture of ceramic components (gypsum, calcium carbonate, etc.) and also organic components. 4 3 2 4 6 8 1 12 14 Temperature [ C] -15 Analysis using STA and QMS The picture shows the simultaneous thermogravimetry (TG) combined with differential scanning calorimetry (DSC) and mass spectroscopy (MS). The mass spectrometry allows the identification of the evolved gases from the material. Mass spectrometry shows peaks from H 2 O at low temperatures most probably from gypsum. The DSC peaks and the signal from mass spectrometer between ~3 C 4 C indicates the decomposition of organic components. The peak of CO 2 at ~8 C indicates the decomposition of CaCO 3. At ~13 C CaSO 4 decompose (SO 2 Peak). Decomposition of CaC 2 O 4 Time [min ] 5 1 15 2 25 3 35 4 45 5 55 6 65 7 75 8 85 9 95 The evolved gases from the decomposition of calcium oxalate have been fed into the mass spectrometer with a heated capillary. The ion currents for mass numbers 18 (water), 28 (carbon monoxide) and 44 (carbon dioxide) have been imported into the graph. dm-rel [%] -5-1 -15-2 -25-3 -35-4 -45-5 -55-6 DTA Signal [µv] 35 3 25 2 15 1 5-5 -1-15 -2-25 -3 dm-rel[ca-ox-1] DTA Signal[Ca-Ox-1] Ion Current_18[Ca-Ox] Ion Current_28[Ca-Ox] Ion Current_44[Ca-Ox] Mass change -12.13% Mass change -18.69% Mass change -3.5% 979.8 C -61.% 28 26 24 22 2 18 16 14 12 1 8 6 4 2 Ion Current_18 [E-12 A] 1 2 3 4 5 6 7 8 9 1 Temperature (smoothed) [ C] Mass spectromy of roof tile clay 2-2 3. 2. 1. Mass change -14.8% DTA Signal smoothed [CUSO-1]. -4. 1. -6-1. -8-2. 2. -1-12 -3. -4. Mass change -14.3% 3. dm-rel [%] -14-16 -18-2 -22-24 -26-28 -3-32 -34-36 -38-4 DTA Signal (smoothed) [µv] -5. -6. -7. -8. -9. -1. -1. -12. -13. -14. -15. -16. -17. dm-rel[cuso-1] Mass change -7.25% 4. 5. 6. 7. 8. 9. 1. dm-rel(derived) [%/min] 4 6 8 1 12 14 16 18 2 22 24 26 28 3 Temperature (smoothed) [ C] 5

FTIR The Fourier transform infrared spectroscopy (FTIR) is a technique which is used to obtain an infrared spectrum of absorption, emission, photoconductivity or Raman scattering of a solid, liquid or gas. An FTIR spectrometer simultaneously collects spectral data in a wide spectral range. This confers a significant advantage over a dispersive spectrometer which measures intensity over a narrow range of wavelengths at a time. FTIR has made dispersive infrared spectrometers all but obsolete, opening up new applications of infrared spectroscopy. The combination of a Linseis Thermal Analyzer with a FTIR is especially interesting in fields such as polymers, chemical and pharmaceutical industry. The coupling is more than the sum of the separate parts. Benefits come from the LINSEIS coupling knowledge and integrated hard- and software concept. For interpretation different libraries are available. Possible Couplings: Thermobalance + FTIR Spectrometer in the temperature range from -17 C up to 175 C L81/I-FTIR Thermo balance + FTIR Spectrometer L81/II-FTIR Thermo balance + FTIR Spectrometer STA PT 16-FTIR Thermo balance + FTIR Spectrometer STA PT 1-FTIR Thermo balance + FTIR Spectrometer Features Research balance (different models) with TG or simultaneous TG/DSC or TG/DTA measurement. High precision Nicolet FTIR spectrometer (different model available). Temperature range -17 C up to + 175 C Three separate heating zones, at capillary, at TG protection tube and at FTIR measuring cell. Carrier gas with wide range of flow rates. Especially developed JLF-detector with long optical pass length. Description Both manufacturers Linseis and ThermoFisher Nicolet are some of the leading companies in their specialized fields. This cooperation guarantees outstanding performance for the combined system. Transfer line is temperature controlled up to a maximum of 25 C. Fast response time through short transfer line. FTIR detector with very high sensitivity and with different wave numbers available. The following applications can be measured: outgassing components of burned material (paints etc.), determination of blenders and additives, absorption and desorption processes, analysis of rubbers and plastics. Thermobalance with coupling to Nicrolet FTIR spectrometer. The coupling is made with a heated capillary. 6

Cement 1 99 Cement 134.7 C -.8% -.5% -.1% 733.4 C 2 1.75 1.5 98 15 1.25-1.6% TG [%] 97 1 CO 2 1..75 H 2 O 96 266.4 C.5 95 H 2 O 69.8 C 5.25 94 CO 2 132.7 C 1 2 3 4 5 6 7 Temperature [ C] Introduction and application Cement is an inorganic, non-metallic material. Together with water it hardens and afterwards it stays also hard under water. Portland cement consists of limestone, clay and/or sand. The additives gypsum, anhydrite etc. influence the setting time of the cement. Impurities in the raw cement cause negative influence on the quality of the cement. Analysis using thermogravimetry and FTIR The additives can be identified and quantified with thermal analysis. The first step shows the evolved water from the CaSO 4 di-hydrate to CaSO 4 half-hydrate. The second step is the conversion of the CaSO 4 half-hydrate to the CaSO 4 anhydrite. The evolved water can also be verified by FTIR analysis. Between 6 C and 75 C the carbonates decomposed so CO 2 evolves. The shoulder in the CO 2 trace of the FTIR signal is the decomposition of MgCO 3. CaSO 4 2H 2 O CaSO 4 ½H 2 O CaSO 4 7

MS-Sniffer Due to the limitation of the input pressure of the MS, the sample gas must be taken after the pressure controller (at ambient pressure). So, only substances which can pass through the cold trap can be analyzed. The outgassings of the sample are passed to the QMS-analyzer directly, using a very small aperture. This small aperture (or orifice) reduces the pressure inside the pressure vessel to the input pressure allowed for the QMS. Since this aperture is inside the hot zone of the furnace, condensation of the out gassings can t take place. Since between the aperture and the ion-source of the QMS a vacuum of app. 1e-5mbar exists, condensation there is impossible also. The sniffer is placed directly above the sample. This is possible because of the the sniffer material, which can resist the temperatures in the hot furnace area. Sniffer Protection tube Aperture Sample Heater Gas 1 Gas 2 Gas 3 Purge H 2 O 2 MFC MFC MFC MFC HPLC Pump pump.7bar bar 7.5Bar bar P P G Manometer M Pressure- controller Vacuum Vacuum- gauge Condensor Evaporator Vacuum- pump Tank Outlet Analyser Coupling to a high pressure system 8

GCMS During heating samples often undergo phase transitions and/or weight change due to evaporation of solvents and/or chemical reactions. These changes can be detected by thermal analysis: calorimetric techniques (DTA and DSC) give information about the heat involved in these processes and thermogravimetry (TG) shows the weight change. Weight change can be either weight increase due to oxidation reactions or weight loss due to decomposition by liberation of volatile compounds. Analysis of these evolved gases can give valuable information about the sample composition and reaction pathways for decomposition. As thermal analysis gives no information about the nature of the evolved gases, coupling with spectrometers or chromatographs is a valuable tool for evolved gas analysis (EGA). 9

Thermal decomposition of latex 1 9 8 TG DSC 5 At 37 synthetic rubber decomposes into some monomer parts. The main parts limonene and isoprene can be identified using STA combined with GC-MS. The STA signal shows mass loss and enthalpie TG [%] 7 6 5 4 87.5% -5-1 DSC [mw] change at 372. At the same time the GC shows two peaks, a smaller and a bigger one, where the samller one can be identified by mass spectrometrie as isoprene and the bigger one as limonene. 3-15 2 1 372 C -2 1 15 2 25 3 35 4 45 5 Temperature [ C] -25 5 2 45 4 35 mau 3 25 1 2 15 1 2 21 22 23 24 25 26 27 28 Time [min] 1 1 1 2 Limonene 9 Isoprene 9 8 8 7 7 Relative Intensity 6 5 4 Relative Intensity 6 5 4 3 3 2 2 1 1 2 3 4 5 6 7 8 9 1 12 13 m/z 2 3 4 5 6 7 8 9 1 12 13 14 15 16 m/z 1

InSitu Possible Techniques: FTIR: Fourier Transform Infrared Spectroscopy: Measurement of basic and trace gas components until ppm range (for example H 2 O, CO 2, CO, H 2 S...). Polar Molecules are necessary. Raman-Spectroscopy: Measurement of basic gas components. Also not polar molecules like H 2 or N 2 are measurable. ELIF: Excimer Laser induced Fragmentation Fluorescence: UV-Laserbased Method of Measuring of gaseous alkaline compounds (for example NaCI, NaOH, KCI, KOH). Also at 193 nm an entry through UV_Saphire is possible. Advantages of the optical In-Situ window: No cooling / modification of the measuring gas (for example no out-condensation, no transition reaction, no equilibrium shift) Many materials with high condensation temperature for example alkali metals (Na, K and their combinations) are now able to be measured, heated capillary only suitable for some 2-25 C, the optical port allows measurement until 16 C No intervention into the measuring system (for example when pulling gas by vacuum) No contamination of the measuring gas in the capillary to M/S or FTIR Real-time online-measurement (no dead time until measuring volume enters the measuring instrument 11

LINSEIS GmbH Vielitzerstr. 43 951 Selb Germany Tel.: (+49) 9287 88 - Fax: (+49) 9287 7488 E-mail: info@linseis.de LINSEIS Inc. 19 North Gold Drive Robbinsville, NJ 8691 USA Tel.: +1 (69) 223 27 Fax: +1 (69) 223 274 E-mail: info@linseis.com Products: DIL, TG, STA, DSC, HDSC, DTA, TMA, MS/FTIR, In-Situ EGA, Laser Flash, Seebeck Effect Services: Service Lab, Calibration Service www.linseis.com