Spectrophotometer for Life Science. BioSpec-nano C101-E112D

Similar documents
C101-E112. BioSpec-nano. Shimadzu Spectrophotometer for Life Science

Operation Manual. SPECTRO-NANO4 Nucleic Acid Analyzer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Protein Sequencer PPSQ-31A / 33A C297-E055B

INSTRUCTION MANUAL. VWR myspec spectrophotometer

TL6 Ultra Micro-volume Spectrophotometer

BioDrop DUO dsdna Application Note

Single Nano Particle Size Analyzer

ND-1000 Spectrophotometer. V3.5 User s Manual

Micro-Spectrohpotometer USERS MANUAL


ND-1000 Spectrophotometer. V3.3 User s Manual

Nano Spectrophotometer LNS-A10

The Plus for your lab!

C146-E209. Headspace Samplers. HS-20 Series

Colorimetric Protein Assays Thermo Scientific NanoDrop Spectrophotometers

Nucleic Acid Thermo Scientific NanoDrop Spectrophotometers

C101-E145 TALK LETTER. Vol. 17

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

A new chapter. medicacorp.com

Optical density measurements automatically corrected to a 1-cm pathlength with PathCheck Technology

Nucleic Acid Quantitation in Microplates

Instruction Manual. Qubit Fluorometer. probes.invitrogen.com/qubit

Spectrophotometric quantification of nucleic acids using the nanovette microliter cell accessory with a DU 730 spectrophotometer

Jasco V-670 absorption spectrometer

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

SPECTROPHOTOMETERS. Visible and UV-Visible

EXPERIMENT 14. ACID DISSOCIATION CONSTANT OF METHYL RED 1

Orbit Support Pack for Excel. user manual

Chiral Separation Using SFC and HPLC

1. Intended use. 2. Introduction. 3. Assay description. 4. Limitations. Instruction For Use Gyrolab Generic PK Kit

Biochrom Libra. UV-Visible Spectrophotometers. High performance instruments with added application value for academia, research and industry

Microplate Spectrophotometer

An ultra-sensitive, versatile, and affordable single tube luminometer for Life Science Research.

SOFTWARE USER MANUAL. Weather Capture Advance WS1640 WM9280

Spectrometer User s Guide

Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry

CHEMISTRY WORKSTATION. The power of proven quality GIVING YOU PEACE OF MIND

Kinetics of Crystal Violet Bleaching

Qubit RNA XR Assay Kits

In Association With. Introduces. TPT Contractor

ISSP User Guide CY3207ISSP. Revision C

High-throughput Quantification of DNA for NGS Library Prep with the Zephyr G3 Workstation and the VICTOR Nivo Plate Reader

A novel approach to the analysis of multivitamin by online supercritical fluid extraction/supercritical fluid chromatography

Ion Sphere Assay on the Qubit 3.0 Fluorometer

UV / VIS Spectrophotometer EMCLAB Instruments GmbH

Subject: Cycle Modification on the ABI 3900 DNA Synthesizer using software v1.2

Reference Manual. Program Help for Electrophoretic Buffer Studies. Version 1.3. Copyright 2001 ANALIS sa/nv

Zetasizer Nano-ZS User Instructions

Experiment 1 Chemical Kinetics 1

PowerWaveX Select and KC4 : A Multifunctional System for Today s Laboratory Environment

User's Manual. Chemical software Acid-base equilibria for Windows. ABEW Version Windows XP - Windows Vista - Windows 7 - Windows 8 - Windows 10

NanoPhotometer NP80/N60/N50/C40 User Manual. Version 1.0.5

Protocol for Use of BCMP Jasco J-815 Circular Dichroism Spectropolarimeter

Qubit RNA IQ Assay Kits

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

CLINICAL CHEMISTRY ANALYSER. The economical solution for all your needs GIVING YOU PEACE OF MIND

1/5 Specifications Hidex 300 SLL automatic TDCR liquid scintillation counter

How to Make Photometric & Colorimetric Measurements of Light Sources using an Ocean Optics Spectrometer and SpectraSuite Software

Size Determination of Gold Nanoparticles using Mie Theory and Extinction Spectra

JAPAN QUALITY. Automated Clinical Analyzer

Determination of VOCs by USEPA Method 8260 with Extended Dynamic Range using Fast, Sensitive Capillary GC/MS

Experiment 13. Dilutions and Data Handling in a Spreadsheet rev 1/2013

Qubit dsdna BR Assay Kits

High-sensitivity, high-throughput quantitation of catecholamine metabolites in urine by LC/MS/MS for clinical research

FLUORESCENCE APPLICATIONS

Quick Start Guide New Mountain Visit our Website to Register Your Copy (weatherview32.com)

Qubit RNA BR Assay Kits

Auto-Immunity & Ease of Use through Automation. The DIAsource Neptune Instrument & Reagents

FoodScreen Radiological Food Screening System

This page intentionally left blank

Eppendorf UVette. Instructions for use

novaa 800 D Atomic Absorption Spectrometer

JAPAN QUALITY. Automated Clinical Analyzer

GE Healthcare Life Sciences. Spectrophotometry. Handbook

COMBI has been developed to be easily integrated in all types of laboratories and hospitals for routine, emergency as well as specific analysis.

LightCycler 480 Instrument Quick Guide Relative Quantification

Manual. Low Shear Viscometer LS 300. prorheo GmbH Bahnhofstr Althengstett Tel

Determining the Concentration of a Solution: Beer s Law

Protein Deconvolution Version 2.0

α m ! m or v T v T v T α m mass

Micro Volume QuEChERS kit

Manual Laser Doppler Anemometry Manual remote experiment Project e-xperimenteren+

L-malic acid measurement in wines using the SpectraMax Plus 384 Microplate Reader

Nanoparticle Analyzer

genesig Easy q16 Validation kit

Protein Quantification Kit (Bradford Assay)

Qubit 4 Fluorometer. Catalog Number Q Publication Number MAN Revision B.0. For Research Use Only. Not for use in diagnostic procedures.

Minimum (-31) every 10 s -35 (-31)

Photoluminescence Spectrometer (FLS980)

Gyrolab Protein A Kit Quantification of residual Protein A ligands in the presence of excess amounts of IgG

Colorimetric Assay for Nitric Oxide Product No For Research Use Only

Qubit 3 Fluorometer. Catalog Number Q Publication Number MAN Revision B.0. For Research Use Only. Not for use in diagnostic procedures.

ab MDA Assay Kit (competitive ELISA)

Understanding Your Spectra Module. Agilent OpenLAB CDS ChemStation Edition

WeatherHub2 Quick Start Guide

cobas e 411 analyzer Confidence in every result.

ON SITE SYSTEMS Chemical Safety Assistant

Circular Motion and Centripetal Force

SolidSpec-3700 SolidSpec-3700DUV

Measurement of L-Malic Acid in Wines Using the SpectraMax Plus 384 Microplate Reader

Transcription:

Spectrophotometer for Life Science BioSpec-nano C11-E112D

BioSpec-nano Spectrophotometer for Life Science Drop-and-Start Analysis Automatic Optical Pathlength Setting & Automatic Wiping Low Carryover Achieved with Automatic Wiping Feature Quick & Simple Operation Outstanding Measurement Accuracy & Reproducibility P. 4 P. 5 P. 5 P. 6 P. 7 Stress-free Nucleic Acid & Labeled Nucleic Acid Quantitation Outstanding Analysis Range & Measurement Reproducibility Photometric Measurement BioSpec-nano Specifications P. 8 P. 9 P. 1 P. 11

With a focus on ease of use, high-accuracy quantitation of nucleic acids and proteins has become quicker and faster. In addition, photometric measurement is now possible. 1 µl or 2 µl Nucleic Acid Quantitation Note1) Analysis can be performed with 1 µl (pathlength:.2 mm) or 2 µl (pathlength:.7 mm) samples. Easy Drop-and-Start Measurement Automatic sample mounting eliminates the need for arm raising and lowering, and the automatic wiping feature makes wiping of the measurement sample unnecessary, enabling measurement of one sample after another. Excellent Reproducibility and Measurement Accuracy High reproducibility is obtained even when measuring low concentration samples. High correlation is achieved with the measurement values provided with the double beam spectrophotometer. Quick & Simple Operation Blank measurement, sample measurement, output of reports as PDF or CSV files, and other basic operations are performed quickly and simply with a click of a button. Stress-Free Analysis with Data Judgment Feature Automatic data judgment based on the OD8 measurement value eliminates the need for concern about inadequate measurement caused by a drop in volume or the inclusion of bubbles. Note 1) When measuring substances like proteins that do not easily form droplets, deposit more than 1 2 µl of sample.

Drop-and-Start Analysis [1 µl / 2 µl samples can be measured.] Note2) Just drop the sample onto the target and click the button. That's all there is to analysis. The instrument will perform everything else for you sample mounting, measurement and wiping. Liquid-contact parts no longer need to be wiped with a cloth. 1. Drop the sample Sample volume required for measurements are : 1 µl for pathlength.2 mm 2 µl for pathlength.7 mm 2. Outstanding analysis range & measurement reproducibility The optimum pathlength for the sample concentration can be selected using the instrument lever. 3. Start measurement Click the [start] button to start sample measurement. You will find using the [start] button on the instrument handy when performing analyses with gloves on. Button in software window Instrument [start] button Automatic sample wiping allows the analyst to deposit the next measurement sample while the current sample is being measured without having to put down the pipette. Measurement is easy even when there are many samples. 4. Check the analysis results Analysis results are automatically displayed after measurement ends. A series of samples can be analyzed while confirming spectra in the Detailed View Mode. [Simple Nucleic Acid Quant. - Detailed View Mode] [Measurement Sample: Purified dsdna in Tris-EDTA (TE) buffer] Note 2) When measuring substances like proteins that do not easily form droplets, deposit more than 1 2 µl of sample. The results can be checked using the analysis data judgment feature. (See P. 7) 4

Automatic Optical Pathlength Setting & Automatic Wiping From setting the optical pathlength to measurement to wiping away the sample, it s all automatic. Tedious operations, like raising and lowering the arm to set the pathlength and wiping off the sample with a piece of cloth, are no longer required. There is no need to worry about whether the sample has been thoroughly wiped away, or whether the measurement site might become scratched. Depositing sample Upper window Target Lowering window and measurement Sample wiping and raising window Low Carryover Achieved with Automatic Wiping Feature The automatic wiping function of the BioSpec-nano greatly minimizes sample carryover from one measurement to the next. Below are the results of alternate measurement of a double stranded DNA sample and a blank (TE buffer), each measured 6 times with automatic one-time wiping Note 3) between measurements. In order to determine the level of carryover from the measured DNA sample, measurement of the next blank was conducted without replacing the wiper during the analyses. The results indicated that carryover Note 4) was extremely low, averaging a mere.13%. Note 3) Automatic wiping following measurement can be set to a maximum of 5 times. Normally, wiping just once is sufficient to obtain good results, however, wiping 3 times is recommended for samples having high viscosity, such as protein samples. Note 4) Carryover (%) = (calculated DNA concentration when measuring TE buffer / concentration of DNA measured immediately before) x 1. Measurement Values from 6 Alternate Measurements Each of Double Stranded DNA Sample and Blank (TE Buffer) 15 OD Value 1 5 2 4 6 8 1 12 Number of Measurements BioSpec-nano Spectrophotometer for Life Science 5

Quick & Simple Operation Basic operations can be conveniently performed by clicking icons in the software or function keys on the instrument itself. Organizing data is also easy even when there many samples. Start Blank Display of Measurement Results Detail / List Toggles between the Detail and List view modes. Detail List Displays the analysis results and spectrum of the sample currently selected. Displays the analysis results of all samples in a table format. Converts analysis results to PDF files, and displays them using Adobe Reader. Saves Analysis Results Saves analysis results to CSV or PDF files. CSV files can be edited in Microsoft Excel or other spreadsheet software. Display PDF Save CSV/PDF 6

Outstanding Measurement Accuracy & Reproducibility [Secure Analysis / High Measurement Accuracy] As little as 1 2 µl of undiluted sample can be measured as is. High reproducibility is obtained even when measuring low concentration samples. High correlation is achieved with the measurement values provided with the double beam spectrophotometer. Example of 1 Successive Measurements of the Same Sample (Double Stranded DNA) Pathlength:.2 mm (Example of analysis at 1 µl) Pathlength:.7 mm (Example of analysis at 2 µl) 4 CV.84 % with OD Value 4 (Concentration: 2, ng/µl) Measured OD26 2 Measured OD26 5 CV 1.4 % with OD Value 1.5 (Concentration: 75 ng/µl) 2 4 Correct OD26 Correct OD26 5 Sample : Diluted purified double stranded DNA Buffer : TE Instrument : Shimadzu double beam spectrophotometer Measurement using 1 mm cell and.1 mm cell. Example of 1 Successive Measurements of the Same Sample (BSA = Bovine Serum Albumin) Pathlength:.2 mm (Example of analysis at 3 µl) Pathlength:.7 mm (Example of analysis at 4 µl) Measured OD28 4 2 CV 1.5 % with OD Value 43 (Concentration: 65, µg/ml) Measured OD28 8 6 4 2 CV.98 % with OD Value 4 (Concentration: 6,6 µg/ml) 2 Correct OD28 4 2 4 6 8 Correct OD28 Sample Buffer : BSA : Distilled water Instrument : Shimadzu double beam spectrophotometer Measurement using 1 mm cell and.1 mm cell. Analysis Data judgment If a droplet is not properly formed for some reason, such as because of, the depositing of insufficient volume, or if the sample contains bubbles, a larger OD8 value is generated. If the measured value is outside the range of the set OD8 value, is displayed, allowing confirmation of the measurement validity. (Note: This applies to sample solutions that do not exhibit absorption at 8 nm.) BioSpec-nano Spectrophotometer for Life Science 7

Stress-free Nucleic Acid & Labeled Nucleic Acid Quantitation Simple Nucleic Acid Quantitation Mode For the quantitation of RNA, dsdna, ssdna, and OligoDNA. The nucleic acid concentration and OD ratio (OD26/28 and OD26/23) are calculated. [Simple Nucleic Acid Quant. - Detailed View Mode] [Measurement sample: Purified dsdna in TE buffer] [Analysis Setting Windows - Simple Nucleic Acid Quant.] Labeled Nucleic Acid Quantitation Mode For the quantitation of nucleic acids (RNA, dsdna, ssdna, OligoDNA) labeled by Cy3, Cy5, Alexa Fluor 546, and Alexa Fluor 647 Note5). The nucleic acid concentration, label concentration, nucleotide concentration, and labeling ratio are all calculated. [Labeled Nucleic Acid Quant. - Detailed View Mode] [Measurement Sample: OligoDNA labeled by Cy3 in TE buffer] [Analysis Setting Windows - Labeled Nucleic Acid Quantitation] Note 5) Four dyes are pre-registered. An additional 8 new labels can be registered. 8

Outstanding Analysis Range & Measurement Reproducibility Protein Quantitation Mode The protein concentration is calculated from the molar absorption coefficient. [Protein Quantitation (OD28 Method) - Detailed View Mode] (Measurement Sample: BSA) [Analysis Selection Window - Protein Quantitation (OD28 Method)] Labeled Protein Quantitation Mode Cy3, Cy5, Alexa Fluor 546, and Alexa Fluor 647 Note 5) are used for quantitation of labeled proteins. The protein concentration, label concentration, and labeling rate are calculated. [Labeled Protein Quantitation - Detailed View Mode] (Measurement Sample: Alexa Fluor 546-IgG) [Analysis Selection Window - Labeled Protein Quantitation] BioSpec-nano Spectrophotometer for Life Science 9

Photometric Measurement Photometric Measurement Mode OD values can be displayed for up to 8 freely selected wavelengths. [Photometric Measurement - Detailed View Mode] (Measurement Sample: BSA) [Analysis Selection Window - Photometric Measurement] Option Cell (Pathlength: 5 mm) The 5 mm pathlength cell and 5 mm cell adapter are required separately. The optional 5 mm pathlength cell and its adapter are placed over the target for use as shown below. Measured OD26 Correct OD26 Example of analysis at 2 ml* 5 mm pathlength cell (sample volume: 2 ml) (P/N: 28-92258) 5 mm cell adapter (P/N: 26-26513) * All of the analysis example data are provided for reference only. 1 OD corresponds to 5 ng/µl dsdna. Sample: Purified dsdna Buffer: TE Ten measurements were performed at each point. 1

BioSpec-nano Specifications Hardware Specifications Item Measuring wavelength range Spectrum bandwidth Wavelength accuracy Pathlength Photometric range Photometric value unit Option cell Sample volume Light source Monochrometer Specification 22 to 8 nm 3 nm ±1 nm.2 mm,.7 mm (manual selection) to 1.5 Abs OD (Optical Density), absorbance converted with 1 mm pathlength Available (pathlength: 5 mm, sample volume: 2 ml) Pathlength lever switched to Option (5 mm) position 1 µl min. (pathlength:.2 mm) 2 µl min. (pathlength:.7 mm) Xenon flash lamp Holographic grating Item Specification Detector Photo diode array Auto wiping function Provided Sample mount function Auto Spectrum measuring time 3 sec Quantitation range* Pathlength.2 mm, 1 to 75 OD 5 to 3,7 ng / µl (OD, dsdna concentration) Pathlength.7 mm,.3 to 21 OD 15 to 1, ng / µl Optional 5 mm pathlength cell,.4 to 3 OD Power requirements 2 to 15 ng / µl AC 1 V / 12 V / 22 V / 23 V / 24 V, 5 / 6 Hz, 4 VA Ambient temperature, humidity 18 to 28 C, 4 to 8% (without dew condensation) Dimensions & Weight Width 21 mm x Depth 214 mm x Height 417 mm 7 kg *Quantitation range is a range which can secure the accuracy (±1% as a guide) specified by us. Software Specifications Item Analysis mode Simple nucleic acid quantitation Labeled nucleic acid quantitation Protein quantitation Photometric measurement Label management Specification Simple nucleic acid quantitation, labeled nucleic acid quantitation, protein quantitation, labeled protein quantitation, photometric measurement Nucleic acid concentration (RNA, dsdna, ssdna, OligoDNA) calculation, OD ratio (OD26 / 28, OD26 / 23) calculation Nucleic acid concentration (RNA, dsdna, ssdna, OligoDNA), nucleotide concentration calculation, Label concentration, labeling ratio calculation, OD ratio (OD26 / 28) calculation Protein concentration (M, µg/ml), label concentration, labeling ratio OD display for 8 wavelengths maximum Label registration (up to 8 new labels), edit, deletion Default labels (Cy 3, Cy 5, Alexa Fluor 546, Alexa Fluor 647) Item Analysis results display Analysis data judgment PDF output CSV output User management (Multiple user mode) Specification Detailed view (displays the focused sample analysis results and spectrum) List view (displays analysis results of all samples) OD ratio (OD26 / 28, OD26 / 23), OD 8 judgment Analysis results (detailed view, list view) saved in PDF file Analysis results (detailed view, list view), spectra data saved in tab delimited text Multiple user or single user mode selected at the time of installation User management: User registration, edit, deletion Login: User name, password entry Data saved in respective folders PC Requirements for BioSpec-nano * A separate PC is required. Item OS CPU System memory Hard disk capacity Display resolution USB 2. port Printer Disk drive Specification Windows 7 Professional 32/64bit edition Windows 1 Pro 64bit edition 1.6 GHz or higher processor 512 MB or larger (1 GB or larger when using Windows Vista) 4 GB or larger 124 768 pixels or above 1 port or more (for connecting the instrument), 2 ports or more when using a USB printer Printer compatible with the system used DVD-ROM or CD-ROM drive H: 417 mm Consumables P/N 26-2591 Part Name Wiping paper (highly absorbent wiper, 1 sheets/set) W: 21 mm D: 214 mm BioSpec-nano Spectrophotometer for Life Science 11

BioSpec-nano www.shimadzu.com/an/ For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country. Company names, products/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation, its subsidiaries or its affiliates, whether or not they are used with trademark symbol TM or. Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not they are used with trademark symbol TM or. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. The contents of this publication are provided to you as is without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. Shimadzu Corporation, 217 First Edition: December 28, Printed in Japan 3655-8711-1AIT