ChromTech HPLC System

Similar documents
ION CHROMATOGRAPHY SYSTEM S 150

Transferring HPLC methods from the HP 1090 Series to the Agilent 1100 Series HPLC system

Varian Galaxie Chromatography Data System for Preparative HPLC

FLASH CHROMATOGRAPHY

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

Figure 1. Structures for Vitamin B2 and Vitamin B1.

UV3000. Accurate, precise, and portable ambient gas point analyzer

Routine MS Detection for USP Chromatographic Methods

SPECTROPHOTOMETERS. Visible and UV-Visible

LC-2000Plus Series. High Performance Liquid Chromatograph

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

Setting the Standard for Advanced GPC/SEC Systems

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

novaa 800 D Atomic Absorption Spectrometer

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative.

Comprehensive Polymer Analysis Strategies

ION CHROMATOGRAPHY IC-3000 SERIES EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES. Analytical Technologies Limited

Thermo Finnigan LTQ. Specifications

Agilent 385-ELSD Evaporative Light Scattering Detector

Nano Spectrophotometer LNS-A10

THE MEASUREMENT OF SOLAR ULTRAVIOLET SPECTRAL IRRADIANCE PROBLEMS & SOLUTIONS

883 Basic IC plus. The smallest Metrohm ion chromatograph

costech instruments ECS 4010 Elemental Combustion System CHNS-O

Agilent 385-ELSD Evaporative Light Scattering Detector

Chemistry Instrumental Analysis Lecture 31. Chem 4631

Application Note Pharmaceutical QA/QC. Agilent Application Solution. Authors. Abstract. Syed Salman Lateef Agilent Technologies, Inc.

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

HPLC Praktikum Skript

UV-Vis optical fiber assisted spectroscopy in thin films and solutions

Application Note. Author. Abstract. Pharmaceutical QA/QC. Vinayak A.K Agilent Technologies Bangalore, India

2501 High Performance Liquid Chromatography

VUV ANALYTICS VGA-100 GC DETECTOR Gas Chromatograph Agilent 6890 equipped with a 7683 model autosampler Restek 30m x 0.25mm x 0.

Finnigan LCQ Advantage MAX

Smart Sensing Embedded Spectroscopy Platform Botlek studiegroep 06-april-2017

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

Application Note. Author. Abstract. Xinlei Yang Agilent Technologies Co. Ltd Shanghai, China

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

OES - Optical Emission Spectrometer 2000

Ultrafast and sensitive analysis of sweeteners, preservatives and flavorants in nonalcoholic beverages using the Agilent 1290 Infinity LC system

JAPAN QUALITY. Automated Clinical Analyzer

Final Report. Characterisation of Sample Report. Job No 2016/11/12-34 AS No. 1234A. Client Example Contact Sample. Signed Date 2017.

Imagent for fnirs and EROS measurements

Biochemistry. Biochemical Techniques HPLC

TL6 Ultra Micro-volume Spectrophotometer

Hiden CATLAB Systems Microreactor for Catalysis Studies & Thermal Analysis

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

881 Compact IC pro 882 Compact IC plus. Compact ion chromatography for intelligent, reliable and precise analysis

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector

Peptide Isolation Using the Prep 150 LC System

861 Advanced Compact IC

Determination of Polymer Modifier in Asphalt

Automatic titrators, TitroMatic

COMPREHENSIVE LC X LC ANALYSIS OF FLAVORING INGREDIENTS IN DISTILLED SPIRITS

Atomic Absorption Spectrometer ZEEnit P series

Varian 385-LC. ELSD for Low Molecular Weight Compounds

UV / VIS Spectrophotometer EMCLAB Instruments GmbH

Using the Agilent 1290 Infinity II Multicolumn Thermostat with Extreme Temperatures and Flow Rates

Application Note. Edgar Naegele. Abstract

Chapter 13 An Introduction to Ultraviolet/Visible Molecular Absorption Spectrometry

Protein Sequencer PPSQ-31A / 33A C297-E055B

Expediting Achiral SFC Method Development Using a Multi-Channel SFC System with MS Detection

Fast methods for the determination of ibuprofen in drug products

Speeding up 2D chromatography (HPLCxSEC) at it s limits. ..fast, faster ups broken...

Agilent 1260 Infinity Evaporative Light Scattering Detector (ELSD)

Sensitive and rapid determination of polycyclic aromatic hydrocarbons in tap water

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

Open Column Chromatography, GC, TLC, and HPLC

for Acclaim Mixed-Mode HILIC-1 Column

MODERN HPLC FOR PRACTICING SCIENTISTS

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

A Total Solution for Explosives Analysis by Reversed-Phase HPLC with a Parallel HPLC System

JAPAN QUALITY. Automated Clinical Analyzer

Introduction of Hitachi Chromaster 5610 MS Detector for High Performance Liquid Chromatograph

The Plus for your lab!

Method Transfer between HPLC and UHPLC Instruments Equipment-related challenges and solutions

Waters GPC User Guide and Tutorial for Using the GPC in the Reynolds Research Group 2 nd Edition: April 2012

Qualification Specifications for Agilent 1100/1200 HPLC Systems

Luminescence transitions. Fluorescence spectroscopy

Calibration and Temperature Retrieval of Improved Ground-based Atmospheric Microwave Sounder

YOUNG LIN ACME 9000 HPLC

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Cantilever enhanced tunable diode laser photoacoustic spectroscopy in gas purity measurement case study: acetylene in ethylene

High Performance Liquid Chromatography

881 Compact IC pro / 882 Compact IC plus for ion chromatography. Intelligent. Reliable. Precise.

FEATURE ARTICLE. The CS-100 Series High-precision Chemical Solution Monitor in the Semiconductor Cleaning Process. Takaaki Yada.

ActiPix SDI300 Surface Dissolution Imaging System

Multi-Channel SFC System for Fast Chiral Method Development and Optimization

Automated method development using Agilent 1100 Series HPLC systems, Agilent ChemStation and ChromSword software. Application

Dissolution Automation: Basic Questionnaire.


Transcription:

ChromTech HPLC System High-prssure Gradient System (A) High-pressure pump: 2 pcs UV/VIS detector: 1 piece Gradient control module: 1 unit High-pressure gradient mixer: 1 piece Single channel chromatography data system: 1 unit (B) High-pressure pump: 2 pcs Diode array detector: 1 piece Gradient control module: 1 unit High-pressure gradient mixer: 1 piece DAD Data-Processing Software: 1 unit Low-pressure Gradient System (A) High-pressure pump: 1 piece Low pressure gradient mixer Model: 1 piece On-line degasser: 1 piece UV/VIS detector: 1 piece Single channel chromatography data system: 1 unit (B) High-pressure pump: 1 piece Low pressure gradient mixer Model: 1 piece On-line degasser: 1 piece Diode array detector: 1 piece DAD Data-Processing Software: 1 unit Isocratic System (A) High-pressure pump: 1 piece UV/VIS detector: 1 piece Single channel chromatography data system: 1 unit (B) High-pressure pump: 1 piece Diode array detector: 1 piece DAD Data-Processing Software: 1 unit

ChromTech HPLC Pump P230 High Pressure Pump (Analytical) Character: The P230 Pump is a dual plunger solvent delivery system. The mechanical design includes short plunger stroke technology with two check valves. This results in very low pulsation. The microprocessor controlled speed regulation leads to a very stable speed of the step motor, driving the plungers. Integrated calculation software continuously corrects flow rates according to the system pressure. Provide flow rate adjustment function when the actual flow rate is different from the preset. The RS232 remote port is designed to control by data system. Flow range: 0.001-9.999mL/min, with 0.001mL/min increment Flow accuracy: ± 0.3% (1.000mL/min, 8.5MPa, water, ambient temperature); Flow stability: RSD 0.1% (1.000mL/min, 8.5MPa, water, ambient temperature); Max pressure: 40MPa (0.001-4.999mL/min); 20MPa (5.000-9.999mL/min); Pressure precision: the displayed pressure error is less than ± 0.3%; Pressure pulsation: l 1.0%; Line voltage: 220V ± 22V, 50Hz ± 0.5Hz Power consumption: 180W Dimension: 420mm x 280mm x 175mm Weight: 20kg P230P High Pressure Pump (Semi-preparative) Flow range: 0.01-40.00mL/min, with 0.001mL/min increment Flow accuracy: ± 1.0% (10.00mL/min, 8.5MPa, water, ambient temperature) Flow stability: RSD 0.2% (10.00mL/min, 8.5MPa, water, ambient temperature ) Max pressure: 30Mpa (0.01-40.00mL/min); 20Mpa (20.00-40.00mL/min) Dimension: 420mm x 280mm x 175mm

LU230 Low Pressure Gradient Mixer Model LU230 low-pressure gradient mixer is specially designed for upgrading an isocratic pump LC system into multi-pumps low-pressure system. With the mixer you can proceed to mixing and degassing 2-4 kinds of solvents, and then go gradient LC analysis. Flow range: Analytical scale: 0. 001mL/min 9.999mL/min Semi-prep scale: 0. 01mL/min 50.00mL/min Gradient setting range: 0.1% - 100.0%, Gradient precision: 0.2% Gradient accuracy: 2.0% Gradient curve: linearity, step, concavo and convex curve. Vacuum degassing: binary-quaternary (selectable) Power requirement: 110V/220V; 50Hz/60Hz Dimension: 420mm x 280mm x 180mm DG230 On-Line Degasser Flow-through vacuum degassing chamber with a single amorphous perfluorinated copolymer (Teflon AF) degassing membrane Continuously vented vacuum system ZHCR vacuum pump a two-stage, series, stepper motor driven, vacuum pump with a unitary PTFE diaphragm (designed specifically for the rigors of HPLC degassing) Microcontroller self-test vacuum sensor validation on power-up Continuous vacuum system monitoring to ensure optimum operational conditions are maintained Vacuum system fault detection and shutdown function indicators High-efficiency degassing Ready to run a shorter equilibration time Zero baseline fluctuation Low running noise function indicators Channels:1-5 Max flow of single channel: 10mL/min Wetted materials: Teflon AF Degassing channel limited pressure: 4.8 x 105 Pa Channel volume: 480µL Channel internal diameter: 1.2mm Pressure drop: 3.9mmHg/mL/min Power requirement: DC 15V-24V Dimension: 190mm x 140mm x 56mm

ChromTech HPLC Detector UV230+ UV/Vis Detector Character: Diode Array Technology for wavelength change without any mechanical moving parts. Dual lamp (deuterium / tungsten) for a spectral range of 190-720 nm. Programmable change of wavelength (up to 5 steps). Serial interface (RS232C) for external control. Wavelength range: 190-720nm Light source: Deuterium lamp and Tungsten lamp Optical bandwidth: 6nm Wavelength accuracy: ± 0.5nm; Wavelength repeatability: ± 0.1nm; Wavelength programmable time setting range: 0.1-999.9min; Rise Time: 0.0-9.9s; Linear range: 1.5AU (5%) Baseline noise: ±3 x 10-5 AU (empty cell, 254nm, 1.0s); Baseline drift: 5 x 10-4AU / h (empty cell, 254nm, time: 60min) Analytical flow cell :optical path length 10mm; volume 10 µl Semi-preparative flow cell: optical path length 3mm; volume 5µL Micro flow cell: optical path length 3mm; volume 1.2µL Power requirements: 220V, 50Hz Power consumption: 110W Dimension: 420mm x 280mm x 175mm Weight: 8kg

DAD230 Diode Array Detector Character: A full-closed optical system and quartz light fiber based transmission technique was used. High spectral resolution and detect sensitivity were obtained. Combined with the powerful data system (DAD Data System Workstation), the instrument can provide a lot of information including chromatogram, spectra of components, three dimension information and peak purity results. Wavelength Range: 199-618nm (512 Diodes) 190-1015nm (1024 Diodes) Light source: Deuterium lamp and Tungsten lamp Number of Diodes: 512 /1024 Array Resolution: 0.8nm Spectral Resolution: 1.2 nm Wavelength Accuracy: ± 0.5nm Wavelength Repeatability: ± 0.1nm Rise Time: 0.1-9.9s Baseline Noise: <± 1.5x 10-5 (AU); N2 in empty cell, 254nm, 1.0s Baseline Drift: <5 x 10-4 (AU / h) N2 in empty cell, 254nm, time: 60min Flow Cell: Analytical flow cell :optical path length 10mm; volume 10 µl Semi-preparative flow cell: optical path length 3mm; volume 5µL Micro flow cell: optical path length 3mm; volume 1.2µL Operating Temperature: 4 to 40 C Operating Humidity: <80%, non-condensing Power requirements: 110 / 220V, 50 / 60Hz Power Consumption: 110W Dimension: 420mm x 280mm x 180mm Weight: 8kg

DAD Data System Workstation To guarantee DAD system a stable operation under Windows 9x, we adopt virtual driver. With a friendly interface and strong function DAD data-processing platform, users can conveniently observe and process contour map, spectrogram, chromatogram and three-dimensional spectrogram-chromatogram. With sufficient functions of chromatographic data processing and quantitative calculating, arbitrary revolving and parts magnifying, users can obtain more vivid visual effect and results analysis. DAD workstation can provide all kinds of chromatograms, including single wavelength, arbitrary two-wavelength absorptance, wavelength time procedure, max absorption wavelength and total absorption, and among them, the most sensitive detection method is max absorption wavelength chromatogram, while the best method to quantitate reproducibility is total absorption chromatogram. DAD system provides many discrimination methods on peaks purity, including contour map, three-dimensional spectrogram-chromatogram, overlap spectrogram, wavelength comparison diagram and peaks purity calculating method. Users can conveniently built their ultraviolet spectrogram gallery with the multifunctional spectrogram gallery managing and searching procedure, and the programme can auto-pick spectrogram to each peak from spectrogram, chromatogram and three dimensional data; auto-search spectrogram gallery; users can also add the auto-picked spectrogram into appointed gallery.