Petroleum Thermodynamic Research Group

Similar documents
Using Microfluidic Device to Study Rheological Properties of Heavy Oil

SCAL, Inc. Services & Capabilities

X-CELL Analytical. Petroleum Fluids Analysis. St. Francis Xavier University Analytical Services Lab. Equipment Specification Brochure

Hydrocarbon Reservoirs and Production: Thermodynamics and Rheology

P1: IML/FFX P2: IML/FFX QC: IML/FFX T1: IML AT029-FM AT029-Manual AT029-Manual-v8.cls December 11, :59. Contents

Available online at ScienceDirect. Energy Procedia 63 (2014 ) GHGT-12

EXPERIMENTALLY DETERMINING THE VISCOELASTIC BEHAVIOR OF A CURING THERMOSET EPOXY R. Thorpe 1, A. Poursartip 1*

CO 2 Rock Physics: A Laboratory Study

APPLICATION OF DIFFERENTIAL SCANNING CALORIMETRY TO CORE ANALYSIS

Laboratory experiments and numerical simulation on Bitumen Saturated Carbonates: A Rock Physics Study for 4D Seismology

Thermochemistry/Calorimetry. Determination of the enthalpy of vaporization of liquids LEC 02. What you need: What you can learn about

Protocol Particle size distribution by centrifugal sedimentation (CPS)

THERMOPHYSICAL PROPERTIES. Final Report. 1 January March Richard F. Kayser

C80. Calvet Calorimeter From ambient to 300 C. A trademark of KEP Technologies group

The Hangingstone steam-assisted gravity drainage

Matter: Properties & Change

Determination of Volatile Substances Proof of Food Adulteration

Unit 1 Lab Equipment. Chemistry Midterm Review

Seismic behaviour of CO 2 saturated Fontainebleau sandstone under in situ conditions

P- and S-Wave Velocity Measurements and Pressure Sensitivity Analysis of AVA Response

Utilizing Adaptive Focused Acoustics (AFA) Technology to Control Nucleation and Crystal Distribution During API Crystallization

RheolabQC. Rotational Rheometer for Quality Control. ::: Intelligence in Rheometry

Assessing Technical Feasibility of Supercritical Extraction Processes Utilizing Laboratory Equipment

Estimating Permeability from Acoustic Velocity and Formation Resistivity Factor

AUTOMATED FORMULATION SYSTEMS

Physico-chemical characterization and comparison of fluorinated commercial Ski-Waxes.

Non-Newtonian fluids is the fluids in which shear stress is not directly proportional to deformation rate, such as toothpaste,

R13 SET - 1 '' ''' '' ' '''' Code No RT21033

IARJSET. International Advanced Research Journal in Science, Engineering and Technology ISO 3297:2007 Certified Vol. 5, Issue 1, January 2018

Thermodynamics I. Properties of Pure Substances

Engineering Thermodynamics. Chapter 1. Introductory Concepts and Definition

CHAPTER 4 THERMAL CONDUCTIVITY AND VISCOSITY MEASUREMENTS

Modulyzer. Multiparameter Measuring Systems. ::: Unique Density & Concentration Meters

High-Pressure Volumetric Analyzer

Hiden Isochema. Gravimetric Gas & Vapor Sorption Analyzers. Hiden Isochema IGA Series. Advancing Sorption Analysis

PREFACE. Julian C. Smith Peter Harriott. xvii

Correlation of High Pressure Density Behaviors for Fluid Mixtures made of Carbon Dioxide with Solvent at K

Membrane processes selective hydromechanical diffusion-based porous nonporous

6298 Stress induced azimuthally anisotropic reservoir - AVO modeling

Salt-induced Hydrogelation of Functionalised-Dipeptides at high ph

APPLICATION OF DENSITOMETERS TO LIQUID MEASUREMENT Class #

LFA for Thermal Diffusivity and Conductivity of Metals, Ceramics and Polymers

Comprehensive Handbook of Calorimetry and Thermal Analysis

Recap: Introduction 12/1/2015. EVE 402 Air Pollution Generation and Control. Adsorption

YOUR PARTNER IN PARTICLE CHARACTERIZATION

Determination of Polymer Modifier in Asphalt

Performance Investigation on Electrochemical Compressor with Ammonia

Differential Acoustic Resonance Spectroscopy Analysis of Fluids in Porous Media

Caution! Pay close attention to the special operation and safety instructions in the manual of the ultrasonic echoscope.

PVT Course for Oil and Gas Professionals

Dissolution Automation: Basic Questionnaire.

Predicting oil sands viscosity from well logs, NMR logs, and calculated seismic properties

MODELING ASPHALTENE DEPOSITION RELATED DAMAGES THROUGH CORE FLOODING TESTS

The Paradox of Asphaltene Precipitation with Normal Paraffins

RHEOLOGICAL CHARACTERIZATION OF THERMOSETTING RES- IN SYSTEM WITH THERMOPLASTIC FUNCTIONAL LAYER

Crude Oil Compatibility and Diluent Evaluation for Pipelining Parviz Rahimi and Teclemariam Alem, National Centre for Upgrading Technology (NCUT)

CONCEPTS AND DEFINITIONS. Prepared by Engr. John Paul Timola

EVAPORATION YUSRON SUGIARTO

Supercritical Fluid Technology: Extraction and Aerogels

Steven W. Van Sciver. Helium Cryogenics. Second Edition. 4) Springer

Alcolyzer Plus. Beer Analyzing System. ::: Unique Density & Concentration Meters

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

AE 3051, Lab #16. Investigation of the Ideal Gas State Equation. By: George P. Burdell. Group E3

Supporting Information for: Inkjet Printing of High Conductivity, Flexible Graphene Patterns

Sensitivity of Asphaltene Properties to Separation Techniques

Supporting Information

Low Molecular Weight Gelator Dextran Composites

Investigations of Seismic Signatures of CO 2 Saturation as Part of a Geological Storage Project

Gravimetric Analysers for the Characterisation of the Sorption Properties of Materials.

Table of Contents [ttc]

Velocity Measurements of Pore Fluids at Pressure and Temperature: Application to bitumen

VSMOW Triple Point of Water Cells: Borosilicate versus Fused- Quartz

Measurement and Prediction of Speed of Sound in Petroleum Fluids

CHARACTERIZATION OF FLUID-ROCK INTERACTION BY ADSORPTION CALORIMETRY

Bohlin. Rheological instruments backed with rheological experience. Rheological properties

MCR. Applicationspecific. Accessories for Additional Parameter Setting

DSA 5000 M. Density and Sound Velocity Meter. ::: Unique Density & Concentration Meters

Compression and Expansion of Fluids

Biochemistry. Biochemical Techniques HPLC

Physical Chemistry of Polymers (4)

Shear waves in solid-state materials

LIQUID-LIQUID EQUILIBRIUM IN BINARY MIXTURES OF 1-ETHYL-3-METHYLIMIDAZOLIUM ETHYLSULFATE AND HYDROCARBONS

Supplementary Information. Synthesis of soft colloids with well controlled softness

SUPPLEMENTARY INFORMATION

Chromatography: Thin-Layer Chromatography (TLC) & Column Chromatography

High Pressure High Temperature Density of Nontraditional Super Lightweight Completion Fluid for Underbalance Perforation

Today s menu. Last lecture. Measurement of volume flow rate. Measurement of volume flow rate (cont d...) Differential pressure flow meters

Measurement of the organic saturation and organic porosity in. shale

4023 Synthesis of cyclopentanone-2-carboxylic acid ethyl ester from adipic acid diethyl ester

Thermodynamics and the Solubility of Sodium Tetraborate Decahydrate

Malvern Macromolecular Solutions. Innovative Solutions in Material Characterization

Calorimetric Principles and TAM III

Liquid Waste Analysis

Multi-element process analyzer

Design, Testing and Pharmaceutical Applications of a Gas Pressure Controller Device for Solid - Gas Microcalorimetric Titration

Modelling the Chemistry of In-Situ Combustion

CHEMICAL ENGINEERING DEPARTMENT Equipments and List of Experiments in each Laboratory

Review Topic 8: Phases of Matter and Mixtures

Lecture 10. Membrane Separation Materials and Modules

Optical & Spectroscopic Insight into Rheology. SR Kim

Transcription:

Petroleum Thermodynamic Research Group Labs 6-128 & 6-133 Chemical and Materials Engineering (CME) Bldg. The Petroleum Thermodynamic Research Group investigates the properties of hydrocarbon resources including reservoir fluids, heavy oils and bitumen. Our overall goal is to integrate quantitative materials property knowledge and theory from the molecular scale to the nanometer scale to the macro scale so that thermophysical properties, transport properties, and phase behaviors identified across these length scales are better understood. Principal Investigator Dr. John Shaw January 2017

Equipment Highlights include: Differential Scanning Calorimeter The TG-DSC 111 from Setaram can be operated from -100 C to 600 C. The unit can be used alone horizontally or vertically (DSC) for measuring heat capacity, phase transitions and enthalpy of mixing. The DSC coupled to the microbalance (TG-DSC) is used for measuring mass change with temperature

Gemini HR Nano Rheometer A rheometer from Malvern with a broad range of operating conditions for temperature and shear rate. The unit has the following configurations: ü Parallel Plate: Temperature: (ETC ~liq. N2) -100 C~ 500 C For moderate to high viscosity samples ü Double Gap: Temperature: (Peltier ) -20 C ~ 170 C For low to moderate viscosity samples ü Parallel Plate: Temperature: (Peltier ) -24 C ~ 180 C For moderate to high viscosity samples

Nanofiltration Unit ü The nanofiltration unit has been setup to filter heavy oils (e.g., Maya oil, Athabasca Bitumen), vacuum residue and mixtures of asphaltenes in solvents. ü The average pore diameters of the membranes used (gamma alumina or zirconia) range from 5 nm to 500 nm ü The operation temperature range from room temperature to 200 C. ü Partially deasphalted oil (permeate) and asphaltene rich (retentate) are obtained. ü Applications include sample preparation, asphaltene particle size

X-Ray View Cell The x-ray view cell can be used for measurements with black oils: ü Phase behavior ü Phase density ü Phase volume ü Phase composition based on elemental analysis ü Mutual diffusion coefficient ü Gas solubility measurements The operating window is up to 30 MPa and 740 K (467 C). The principle followed here is the same in the X-ray analyses for medical applications

Acoustic Cell ü Phased array acoustic measurements can be used to: Investigate the phase behavior of opaque mixtures. Measure phase distributions and mass transfer in porous media. ü Each acoustic probe has an array of 64 acoustic elements with a nominal frequency of 10 MHz. ü Each probe can send simultaneously 113 acoustic beams with a resolution of 0.3 mm ü Speed of sound and attenuation profiles can be measured along the height of the cell. ü Speed of sound maps of resolution 40 µm can be generated at 8 minute intervals. ü Operational Temperature range= 0-45 C

Density Meter ~ DMA 5000 The DMA 5000 from Anton Paar ü Density range: 0 to 3,000 kg/m 3 ü Pressure range: 0 to 10 bar. ü Temperature: 0 to 90 C ü Accuracy: 0.005 kg/m 3 Automatic sample changer SP-3m that allows filling, cleaning and drying samples with a viscosity up to 1,000 mpa.s There is an Optional heating attachment for samples with viscosities up to 30,000 mpa.s

Density Meter~ DMA HP For high pressure and/or high temperature conditions, we have the external density measuring cell DMA HP which is coupled to the DMA 5000. ü Density range: 0 to 3000 kg/m 3 ü Pressure range: 0 to 700 bar. ü Temperature: -10 to 200 C ü Accuracy: 0.1 Kg/m 3 This unit is recommended for: ü Studying the behavior of liquid and gases a high P & T in order to develop equations of state. ü For high viscosity samples ü For samples that present high melting points or require extreme measurement conditions.

TAM III TAM III is a microcalorimetric system from TA Instruments. Four independent calorimeters can be used simultaneously to perform repetitive or different types of experiments. Currently, three calorimeters Titration Calorimeter, Solution Calorimeter and Perfusion Calorimeter have been acquired. TAM III can be operated in isothermal, step-isothermal or temperature-scanning and the liquid bath temperature can be precisely controlled to within 0.0001 C.

PERFUSION CALORIMETER Perfusion Ampoule ü Liquids are injected using a peristaltic pump while gases can be perfused using a mass flow controller. ü The perfusion ampoule can be used to measure either the heat production rate from a flowing gas/ liquid or the effect of the gas/liquid on a sample placed in the perfusion ampoule. ü It can be used up to 150 C. Solution Calorimeter PRECISION SOLUTION CALORIMETER ü The Precision Solution Calorimeter is a singleposition, semi-adiabatic calorimeter for measurements of the heat generated or consumed when a solid or liquid sample is dissolved or diluted into a solvent. ü The instrument is used for determining enthalpies of mixing. ü It can be used up to 80 C. TITRATION CALORIMETER ü Titration enthalpy measurements provide data on association and interaction of asphaltene in solution.

Standard High Pressure Cell Standard pressure cell from Anton Paar for rheological measurements of samples with low to moderate viscosities a different pressures and temperatures. ü Pressure: up to 150 bar. ü Electrical heating: from room temperature to 300 C ü Peltier: From -25 C to 200 C ü Measuring systems: Concentric cylinder, double gap and parallel plate

Olympus GX71 Inverted Microscope Features: ü Easy to alternate between brightfield, darkfield, polarized light & fluorescence observation. ü High-resolution digital camera DP73 à17.3 megapixel. ü Long working distance objective lenses: 5X, 10X, 20X, 50X & 100X. ü Advanced image analysis software for the digital images transferred to the PC.

MINIVAP VPXpert-L: Pressure Vapor Unit Automatic determination of the vapor pressure of low volatility compounds, gasolines and jet fuels Key features: ü Absolute vapor pressure determination (Static Triple Expansion Method) ü Temperature range: 20-120 C ü Temperature stability: ± 0.01 C ü Temperature profile: single temperature, stepped or ramped ü Pressure range: 0-100 kpa ü Pressure resolution: 0.01 kpa ü Uncertainty: Maximum 1.5 kpa ü Sample Volume: 1 ml

Dynamic Pressure View Cell under development Objectives: ü Observe the effect of pressure fluctuations (sound waves) on bulk fluids, at fluid interfaces and on particle translation/deformation. Features: ü Pressure transducer to measure resulting dynamic response. ü 10 bar design pressure ü Static to ultrasonic pressure fluctuations ü Fluid composition control through access tubes

We gratefully acknowledge and thank our sponsors for their support for our laboratory and our research! ü Alberta Innovates - Energy and Environment Solutions ü ConocoPhillips Inc. ü BP Canada Energy Company ü Nexen Energy ULC. ü Total E&P Canada Ltd. ü Shell Canada Ltd. ü Natural Sciences and Engineering Research Council (NSERC) ü Virtual Materials Group (VMG)