TRANSIENT NUMERICAL ANALYSIS OF INDUCTION HEATING OF GRAPHITE CRUCIBLE AT DIFFERENT FREQUENCY

Similar documents
Simulation and Experimental Validation of Induction Heating of MS Tube for Elevated Temperature NDT Application.

ANALYTICAL, NUMERICAL AND EXPERIMENTAL VALIDATION OF COIL VOLTAGE IN INDUCTION MELTING PROCESS

SIMULATION MODEL OF INDUCTION HEATING IN COMSOL MULTIPHYSICS

Sensibility Analysis of Inductance Involving an E-core Magnetic Circuit for Non Homogeneous Material

A Finite Element Model for Numerical Analysis of Sintering

A domain decomposition approach for coupled fields in induction heating devices

An Approach for Designing a Complex Inductor Workpiece system for Induction Heating

Coupled electromagnetic, thermal and stress analysis of large power electrical transformers

Numerical modeling of magnetic induction and heating in injection molding tools

Maxwell s Equations:

Thermal analysis of magnetic shields for induction heating P. Sergeant 1,2 D. Hectors 3 L. Dupré 1 K. Van Reusel 1,3

ELECTRICAL AND THERMAL DESIGN OF UMBILICAL CABLE

Magnetostatic Analysis of Solenoid

Thermal Analysis for the Solar Concentrating Energy and Induction Heating for Metals

Finite element analysis of the temperature field in a vertical MOCVD reactor by induction heating

I, THERMAL ANALYSIS OF BUS-BAR FOR SWITCH BOARD

Extensions to the Finite Element Technique for the Magneto-Thermal Analysis of Aged Oil Cooled-Insulated Power Transformers

COPYRIGHTED MATERIAL. Basic Field Vectors. 1.1 The Electric and Magnetic Field Vectors

General review: - a) Dot Product

Update On The Electromagnetism Module In LS-DYNA

EFFECTS OF THERMAL AND ELECTRICAL PROPER- TIES OF THIN METAL FILM IN PHOTOINDUCTIVE FIELD-MAPPING TECHNIQUE FOR EDDY-CURRENT PROBES

Electricity & Magnetism Study Questions for the Spring 2018 Department Exam December 4, 2017

EFFECTS OF NON-LINEAR MAGNETIC CHARGE ON INDUCTION FURNACE OPERATION DURING THE HEATING CYCLE Adil H. Ahmad, PhD

Prof. A. K. Al-Shaikhli, Asst. Prof. Abdul-Rahim T. Humod, Fadhil A. Hasan*

Simulation and verification of

Mutual Resistance in Spicelink

Electromagnetic field of the large power cables and interaction with the human body

Mathematical Modelling and Simulation of Magnetostrictive Materials by Comsol Multiphysics

Excerpt from the Proceedings of the COMSOL Conference 2009 Bangalore

VALIDATION OF AN ELECTROMAGNETIC INDUCTION SIMULATION FOR DEFECTS DETECTION: A QUASI-STATIC MODEL FOR AN AUTOMATED INSPECTION SYSTEM

Transient Heat Transfer Experiment. ME 331 Introduction to Heat Transfer. June 1 st, 2017

Analysis of the thermal heating of poly-si and a-si photovoltaic cell by means of Fem

THERMAL ANALYSIS OF UMBILICAL CABLES

Numerical Simulation in Alternating Current Field Measurement

Industrial Heating System Creating Given Temperature Distribution

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 4, Issue 7, January 2015

Antennas and Propagation. Chapter 2: Basic Electromagnetic Analysis

3D Finite Element Analysis of Flat and Bent Plates for Crack Detection using Tone Burst Eddy Current Thermography

3D ELECTROMAGNETIC FIELD SIMULATION OF SILICON CARBIDE AND GRAPHITE PLATE IN MICROWAVE OVEN

Analytical Optimization of High Performance and High Quality Factor MEMS Spiral Inductor

Virtual Prototyping of Electrodynamic Loudspeakers by Utilizing a Finite Element Method

Thermal Unit Operation (ChEg3113)

DR.PRADIP DUTTA Department of Mechanical Engineering Indian Institute of Science Bangalore

Electromagnetics in COMSOL Multiphysics is extended by add-on Modules

NUMERICAL INVESTIGATION AND STATISTICAL ANALYSIS OF LASER BENDING OF TITANIUM SHEETS

Study and Characterization of the Limiting Thermal Phenomena in Low-Speed Permanent Magnet Synchronous Generators for Wind Energy

9th European LS-DYNA Conference 2013

Heat Transfer: Physical Origins and Rate Equations. Chapter One Sections 1.1 and 1.2

BASIC RESEARCH OF THERMAL TRANSFER SIMULATIONS

Thermal modelling for on-interposer thermoelectric sensors

If there is convective heat transfer from outer surface to fluid maintained at T W.

Electromagnetic Analysis Applied to the Prediction of Stray Losses in Power Transformer

The Distortion Influence Simulation and Experimental Study of Human Body to High Voltage Power Frequency Electric Field

Iron core loss calculation with QuickField

Analysis of Thermal Behavior of High Frequency Transformers Using Finite Element Method

Introduction to Heat and Mass Transfer. Week 5

MECH 375, Heat Transfer Handout #5: Unsteady Conduction

Induction Heating: fundamentals

Examination Heat Transfer

PHYSICS 1 (LIFE SCIENCES) ELECTRICITY

INTRODUCTION. Electromagnetic induction is a heating technique for electrical conductive materials. Applications:-

THERMAL ANALYSIS OF A SPENT FUEL TRANSPORTATION CASK

2577. The analytical solution of 2D electromagnetic wave equation for eddy currents in the cylindrical solid rotor structures

Calculation of equivalent magnetic permeability of ferromagnetic materials for modeling of three-dimensional eddy current fields

Design and analysis of the ferrite air-gapped cores for a resonant inductor

The Solution of a FEM Equation in Frequency Domain Using a Parallel Computing with CUBLAS

International Journal of Scientific & Engineering Research, Volume 7, Issue 7, July-2016 ISSN

MODELLING AND TEMPERATURE REGULATION, USING A NEW MARERIAL FeNiCr ALLOY, IN INDUCTION COOKING DEVICE

Investigation of evolution strategy and optimization of induction heating model

ELECTROMAGNETIC-THERMAL ANALYSIS OF AN X-BAND LINAC STRUCTURE BY FINITE ELEMENT SIMULATIONS

Validation of DNS techniques for dynamic combined indoor air and constructions simulations using an experimental scale model

Simulation of Cracks Detection in Tubes by Eddy Current Testing

One dimensional steady state diffusion, with and without source. Effective transfer coefficients

Finite Element Modeling of Electromagnetic Systems

Magnetotelluric (MT) Method

HIGH VOLTAGE TECHNIQUES REVİEW: Electrostatics & Magnetostatics

Advanced Heat and Mass Transfer by Amir Faghri, Yuwen Zhang, and John R. Howell

MFCI (Molten Fuel Coolant Interaction)

Electromagnetic Forming Process Analysis Based on Coupled Simulations of Electromagnetic Analysis and Structural Analysis

Finite Element Model of a Magnet Driven Reed Switch

Coupling of eddy-current and circuit problems

Electromagnetic Testing (ET)

Documentation of the Solutions to the SFPE Heat Transfer Verification Cases

WIAS-HITNIHS: A SOFTWARE TOOL FOR SIMULATION IN SUBLIMATION GROWTH OF SIC SINGLE CRYSTALS: APPLICATIONS AND METHODS.

Thermomagnetic Siphoning on a Bundle of Current-Carrying Wires

Thermal Systems. What and How? Physical Mechanisms and Rate Equations Conservation of Energy Requirement Control Volume Surface Energy Balance

MODELING AND MODIFICATION FOR DISTRIBUTION TRANSFORMER (250 KVA, 11/0.416 KV) TO REDUCE THE TOTAL LOSSES

PHYSICS A Electrons and Photons. OXFORD CAMBRIDGE AND RSA EXAMINATIONS Advanced Subsidiary GCE

Assessing COMSOL Performances on Typical Electromagnetic Problems Faced by Turbo-Generator Manufacturers

ELECTRO-THERMAL ANALYSIS OF PELTIER COOLING USING FEM

A Simple Weak-Field Coupling Benchmark Test of the Electromagnetic-Thermal-Structural Solution Capabilities of LS-DYNA Using Parallel Current Wires

Heat-Accumulation Stoves: Numerical Simulations of Two Twisted Conduit Configurations

1814. Optimized design to improve the function of a magnetic pulse forming device

A Dash of Maxwell s. In Part 4, we derived our third form of Maxwell s. A Maxwell s Equations Primer. Part 5 Radiation from a Small Wire Element

* Univ. Bretagne-Sud, EA 4250, LIMATB, Rue de Saint Maudé, Lorient, France ** IRT JULES VERNE, Chemin du Chaffault, Bouguenais, France

STUDY OF HEAT TRANSFER MECHANISMS DURING THE LENS TM PROCESS

True/False. Circle the correct answer. (1pt each, 7pts total) 3. Radiation doesn t occur in materials that are transparent such as gases.

3.0 FINITE ELEMENT MODEL

Combined heat transfer in floating zone growth of large silicon crystals with radiation on diffuse and specular surfaces

Comparison of Finite Element Analysis to IEC for Predicting Underground Cable Ampacity

Transcription:

TRANSIENT NUMERICAL ANALYSIS OF INDUCTION HEATING OF GRAPHITE CRUCIBLE AT DIFFERENT FREQUENCY Abstract B. Patidar, M.M.Hussain, A. Sharma, A.P. Tiwari Bhabha Atomic Research Centre, Mumbai Mathematical modeling of Induction heating process is done by using 2D axisymmetric geometry. Induction heating is coupled field problem that includes electromagnetism and heat transfer. Mathematical modeling of electromagnetism and heat transfer is done by using maxwell equations and classical heat transfer equation respectively. Temperature dependent material properties are used for this analysis. This analysis includes coil voltage distribution, crucible electromagnetic power, and coil equivalent impedance at different frequency. Induction coil geometry effect on supply voltage is also analyzed. This analysis is useful for designing of induction coil for melting of nonferrous metal such as gold, silver, uranium etc. Keywords: Induction heating, FEM, Coil design, Graphite 1.INTRODUCTION Graphite has been widely utilized in different industries applications, because of it physical properties like good thermal stability, corrosion resistance, high electrical conductivity, thermal shock resistance, high melting temperature, high purity, refractoriness, machinability etc [1]. Graphite electrical, mechanical and thermal properties makes, it suitable for induction melting of non ferrous materials such as gold, silver, uranium etc. In induction heating, graphite crucible is coupled with pulsating magnetic field produced by induction coil, which generates the electro motive force and eddy current in graphite crucible and that will heat it by joules effect. This heat is transferred to the charge (Material that is supposed to melt) through conduction, convection and radiation [2] [3]. Induction heating is multiphysics phenomena i.e combination of electromagnetism and heat transfer [4]. These physics are nonlinearly coupled with each other due to temperature dependent material properties. Mathematical modeling of electromagnetism and heat transfer is done by well known maxwell equations and classical heat transfer equation respectively [2][4] [4].Field equations are solved by using finite element method. This paper presents mathematical modeling of induction heating of graphite crucible. Electromagnetic power induced in different wall thickness of graphite crucibles, and voltage distributions in induction coil are analyzed at different frequency. This model helps to design and optimized the induction coil and graphite crucible for heating application. 35

This paper is organized as follows, section II gives brief description of induction heating system. Mathematical modeling and numerical solution procedure are explained in section III. In section IV, numerical results and analysis are present. Finally conclusion is given in section V. 2.SYSTEM DESCRIPTION Induction melting set up comprises of power source, water cooled copper induction coil, graphite crucible and charge. Power source supplies high frequency current to the induction coil to generate varying magnetic field and heat the crucible. 3 - P h a s e m a i n s p o w e r s u p p l y I n d u c t i o n m e l t i n g p o w e r s o u r c e C o p p e r I n d u c t i o n c o i l G r a p h i t e c r u c i b l e C h a r g e Figure 1:- Schematic of Induction heating system 3.MATHEMATICAL MODEL Mathematical modeling of electromagnetism and heat transfer is done separately. Electromagnetic model is governed by maxwell equations as shown below [5] [6] [7] [8] [9],.=0. = = =+ (1) (2) (3) (4) Here, H: - Magnetic field strength (A/m) E: - Electric field strength (V/m) σ: - Electrical conductivity (S/m) J= Current density (A/m 2 ) 36

D= Electric flux density(c/m 2 ) ρc=electric charge density(c/m 3 ) B= Magnetic flux density (Wb/m 2 ) Constitutional equations for linear isotropic medium, =() = = (5) (6) (7) Here, µ 0 = Free space magnetic permeability (H/m) µ r = Relative magnetic permeability ε 0 = Free space electric permittivity (F/m) ε r = Relative electric permittivity Magnetic field problems are generally solved by using magnetic vector potential formulation and which is derived by using maxwell equations. Magnetic vector potential (A) is defined as, = (8) From eq (3), (4) and (8), Magnetic vector potential equation in frequency domain can be written as, ( )! + " #$()=0 (9) Here, Js= source current density (A/m2) ω=angular frequency (rad/sec) For solving eq (9) in axisymmetric geometry shown in figure 2, following assumption are considered, 1. The system is rotationally symmetric about Z-Axis. 37

2. All the materials are isotropic. 3. Displacement current is neglected. 4. Electromagnetic field quantities contents only single frequency component. For different domain of figure (2), eq (9) can be written as, (%)! =0 in Ω1 (10.1) (%)! + " #$()= 0 in Ω2 (10.2) (%)! #$()=0 in Ω3 (10.3) Figure 2:- 2-D Axisymmetric geometry of induction heating system Eddy current and induced electromagnetics power in graphite crucible are calculated by using magnetic vector potential as shown below, ' ( =()(#$) (11.1) ) = * +, -( ) =()(#$)! (11.2) Here, J e = induce eddy current density (A/m 2 ) 38

Electromagnetism is coupled to heat transfer by power induced (Q) in graphite crucible and that is used as forcing function in heat transfer equation. Temperature in the graphite crucible is governed by the classical heat transfer equation [2] [5] [9] [10],.().(! )+) =/ 0 () (12) Here, T= Temperature (DegK) ρ= Density (Kg/m3) c p = Specific heat ((J/(Kg.K)) K=Thermal conductivity (W/(m.K)) Q conv = convection heat loss (W/m 2 ) Q rad = radiation heat loss (W/m 2 ) t =Time (Sec) For electromagnetism, Dirichlet (A=0) and Neumann boundary conditions and for heat transfer, convection and radiation boundary conditions are used. Convection heat loss can be represent as, ) 123 =h.( 567 ) W/m 2 (13) Radiation heat loss can be represent as, ) 58 =9 7.: ; 567 ; < W/m 2 (14) Here, h=convection coefficient (W/m 2 K) ϵ=emissivity σ b = Boltzmann constant(5.67x10-8 W/m 2 K 4 ) T amp = Ambient temperature (DegK) Induction heating is non linear coupled field problem that makes difficult to solve by analytical method. Hence, Numerical method is used to solve the field equations. Finite element method (FEM) is simple and most preferred numerical method for solving field equation, therefore, FEM is chosen for this analysis. FEM converts continuous equations i.e eq (10) into discrete equation by discretizing geometry of solution domain [2].Discretization can be done by using trigular, rectangular or hexagonal elements. Discretized equations are solved by using segregated or coupled field solver. 39

4.SIMULATION Simulation is done in three steps i.e. preprocessing, processing and post processing using FEM based multiphysics software [7]. Preprocessing Geometry, material and their properties, initial & boundary conditions, forcing function, domain discretization Magnetic vector potential (A) calculation Processing Electromagnetic power (Q) calculation Temperature field (T) calculation Update Material Properties σ (T), K (T), cp (T) t > t set No Yes Output Post processing Calculate parameters such as electromagnetic power, coil impedance, temperature gradient etc Figure 3. Computation steps Preprocessing steps includes creating geometry, assigning materials and their properties to different sub domains, define boundary conditions, initial conditions, forcing function and domain discretization. Processing steps includes the computation of parameters as shown in figure 3. Post processing step includes computation of parameters such as coil impedance, convection and radiation losses etc for further analysis. 40

5.NUMERICAL RESULTS Geometry shown in figure 4 (a) is used for simulation. Solution domain is discretized using trigular elements. Meshing density is more on Surface of graphite crucible and induction coil due to skin effect as shown in the figure 4(b). Graphite temperature dependent material properties are given in figure 4. 4(a) 4(b) Figure 4(a). 2-D axisymmetric geometry, 4(b) Domain discretization (Meshing) Dimension details of induction coil is given in table-i. Graphite temperature dependent material properties such as electrical conductivity, thermal conductivity, specific heat, are shown in figure 5. Electrical conductivity in ks/m 170 160 150 140 Graphite Electrical Conductivity 0 0 400 800 1200 1600 2000 Temperature in DegK Thermal coductivity in W/mK Graphite Thermal Conductivity 220 200 180 160 140 120 100 80 60 40 0 0 500 1000 1500 2000 Temperature in DegK 5(a) 5 (b) 41

Specific heat in J/Kg.K 2000 1600 1200 800 Graphite Specific Heat 0 0 400 800 1200 1600 2000 Temperature in DegK 5 (c) Figure 5:- Temperature dependent material properties of Graphite [2] Table-I Induction coil dimensions and properties Induction coil Description Material Copper Inside diameter 215 Outside diameter 247 Height 200 Coil tube diameter 16 Coil tube thickness 5 No. of turn 9 Initial conditions, boundary conditions and forcing function for electromagnetism and heat transfer are given in table-ii and table-iii respectively. Electromagnetism equations are solved in complete solution domain (induction coil, graphite crucible, air). Heat transfer analysis is done only in graphite crucible, because induction coil is water cooled, and always at room temperature. Table-II Boundary condition and forcing function for electromagnetism Boundary Description condition Outer boundary A=0 Asymmetry axis A n =0 Induction coil 707.21A current 42

Table-III Initial and boundary condition for Heat transfer Boundary condition Description Initial temperature 303 DegK Convection coefficient(h) 10 (W/m 2 K) Emissivity( Graphite 0.7 surface) Emissivity(Refractory 0.01 surface) As induction coil carries single frequency current (because of series resonance configuration), Hence, electromagnetic analysis is done in frequency domain. Heat transfer equation is solved in transient domain. Magnetic field produced by induction coil at 1 khz, 5 khz and 9 khz is shown in the figure 7. Figure 7. Magnetic field at 1 khz, 5 khz, and 9 khz 6.RESULT AND ANALYSIS From figure 7, it is observed that, magnetic field is high on graphite crucible surface and it reduces toward centre of the crucible. At 1 khz, magnetic field penetrates more compared to 5 khz and 9 khz. Figure 8 shows the crucible temperature at different frequency, from figure, it is observe that as frequency increases crucible heat up at faster rate and that is because of increase in coupling between crucible and induction coil. 43

Temperature in Deg C 1200 1000 800 600 400 200 0 0 200 400 600 800 1000 Time in Sec 9 khz 5 khz 1 khz Figure 8. Graphite crucible temperature Figure 9 shows, voltage distribution in different turn of the induction coil. From figure it is observed that from centre turn to outer turn of induction coil, impedance of coil turns are reduced and that is due to maximum proximity effect experience by centre turn compared to other turns. That makes higher voltage drop and power loss in centre turn of the induction coil. This analysis helps the designer for designing of efficient cooling system for induction coil. Voltage in V 55 9 khz 50 45 40 35 5 khz 30 25 20 15 10 1 khz 5 1 2 3 4 5 6 7 8 9 Turn Impedence in ohm 0.05 0.04 0.03 0.02 0.01 9 khz 5 khz 1 khz 0.00 1 2 3 4 5 6 7 8 9 Turn 9(a) 9(b) Figure 9. (a) Turn voltage, 9(b) Turn impedance Figure 10 shows that electromagnetic power induced in graphite crucible at different frequencies. From figure, it is observed that during initial period, power induced in graphite crucible is first reduced and then increase and the reason for this is uniqueness of graphite electrical conductivity, which has both positive temperature coefficient and negative temperature coefficient as shown in figure 5(a). 44

Electromagnetic power in W/m 60000 50000 40000 30000 20000 10000 9 khz 5 khz 1 khz 0 0 200 400 600 800 1000 Time in Sec Figure 10. Electromagnetic power in crucible at different frequency Figure 11 shows the variation of electromagnetic power in crucible at different thickness. From figure it is observed that as crucible thickness increase induce power is increases upto a level and after that it reduces. This is due to the skin effect, means 84%~ power is induced in one skin depth and 98 % ~ in second skin depth. EM power in crucible in W/m 70000 60000 50000 40000 30000 0 20 40 60 80 Crucible thickness in mm 7. CONCLUSION Figure 11. Electromagnetic power in crucible at different thickness Transient numerical analysis of Induction Heating of Graphite Crucible was carried out successfully at different frequency. Electromagnetic power induced in graphite crucible is analyzed at different temperature that gives better understanding of heat transfer in graphite crucible. Voltage at each coil turns are analyzed, that helps in designing of cooling system for induction coil. Effect of crucible wall thickness on induced power is analyzed, that helps for selection of optimum crucible thickness. 45

REFERENCES [1] A.W.Moore, The induction heating of pyrolytic graphite, Pergamon press ltd. Printed in Great Britain, carbon 1967, Vol.5, pp 159-165. [2] Valery Rudnev, Don loveless, Raymond Cook, Micah Black, Handbook of Induction heating, INDUCTOHEAT,Inc., Madison Heights,Michigan,U.S.A. [3] E.J Davies and P.G. Simpson, Induction Heating Handbook. McGraw Hill, 1979. [4] C Chabodez, S Clain, R.Glardon,D, D Mari, J.Rappaz, M. Swierkosz, Numerical modeling in induction heating for axisymmetric geometries, IEEE transactions on Magnetics.Vol33, No.1 January 1997, P 739-745. [5] Jiin-Yuh Jang, Yu-Wei Chiu, Numerical and experimental thermal analysis for a metallic hollow cylinder subjected to step-wise electro-magnetic induction heating, Applied thermal engineering 2007, 1883-1894. [6] Andrzej Krawczyk, John A. Tegopoulos, Numerical modeling of eddy current, Oxford science publications, P-17. [7] Ion Carstea, Daniela Carstea, Alexandru Adrian Carstea, A domain decomposition approach for coupled field in induction heating device, 6th WEEAS international conference on system science and simulation in engineering, Venice, Italy, November 21-23, 2007, P63-70 [8] B. patidar, M. T. Saify, M. M. Hussain, S. K. Jha and A. P. Tiwari, Analytical, Numerical and Experimental Validation of Coil Voltage in Induction Melting Process", International Journal of Electromagnetics(IJEL), Vol 1, No. 1, 2015, pp19-31, [2015] [9]Bo Yun Jang, Joon Soo Kim, Young Soo Ahn, Induction heating process using segmented graphite crucible for silicon heating, Solar Energy Materials & Solar Cell 95 (2011),pp 101-106. [9] Y.Favennec, V.Labbe, F.Bay, Induction heating processes optimization a general optimal control approach, Journal of Computational Physics 183 (2003), pp68-94. 46