Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

Similar documents
Spectrometer User s Guide

Determining the Concentration of a Solution: Beer s Law. Evaluation copy. Figure 1

3-Axis Accelerometer (Order Code 3D-BTA)

Determining the Concentration of a Solution: Beer s Law

Rate Law Determination of the Crystal Violet Reaction. Evaluation copy

Investigating Food Dyes in Sports Beverages. Sample

Determining the Concentration of a Solution: Beer s Law

Physics P202, Lab #12. Rydberg s Constant

Standardizing a Solution of Sodium Hydroxide. Evaluation copy

The Determination of an Equilibrium Constant

Determining the Concentration of a Solution: Beer s Law

The Decomposition of Hydrogen Peroxide. Evaluation copy

Chemical Equilibrium: Finding a Constant, Kc

Evaluation copy. Ground Temperature Measurements. computer OBJECTIVES MATERIALS PRE-LAB QUESTIONS

Acid-Base Titration. Evaluation copy

Measuring ph with Smart Cuvettes

Ocean Optics Educational Spectrometers. Getting Started Manual

Connect the Vernier spectrometer to your lap top computer and power the spectrometer if necessary. Start LoggerPro on your computer.

Photosynthesis and Respiration. Evaluation copy

Photosynthesis. LabQuest OBJECTIVES

Digital Radiation Monitor (Order Code DRM-BTD)

Kinetics of Crystal Violet Bleaching

RATE LAW DETERMINATION OF CRYSTAL VIOLET HYDROXYLATION

1iI1E. The Determination of 0 an Equilibrium Constant [LU. Computer

The Determination of an Equilibrium Constant

Background The power radiated by a black body of temperature T, is given by the Stefan-Boltzmann Law

Physics 197 Lab 11: Spectrometer

The Effect of Alcohol on Biological Membranes

MEASUREMENT: PART II

The Determination of an Equilibrium Constant

Distance From the Sun

A Determination of Planck s Constant with LED s written by Mark Langella

Evaluation copy. The Molar Mass of a Volatile Liquid. computer OBJECTIVES MATERIALS

Experiment 9. Emission Spectra. measure the emission spectrum of a source of light using the digital spectrometer.

Jasco V-670 absorption spectrometer

Acid Rain. Evaluation copy

Cart on a Ramp. Evaluation Copy. Figure 1. Vernier Dynamics Track. Motion Detector Bracket

Experiment 7. Determining the Rate Law and Activation Energy for the Reaction of Crystal Violet with Hydroxide Ion

Exploring the Poles (Without Leaving Your Classroom!)

Evaluation copy 10A. Impulse and Momentum. Experiment INTRODUCTION OBJECTIVES MATERIALS PRE-LAB QUESTIONS

Transpiration. Evaluation copy

2 (aq) [FeSCN [Fe 3JSCN] Figure 1

Experiment 11 Beer s Law

Experiment 11 Beer s Law

Spectrophotometric Determination of pka of Phenol Red

The Magnetic Field of a Permanent Magnet. Evaluation copy

Center of Mass. Evaluation copy

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

This sensor is now also available with a sturdier flat electrode which enables testing even smaller samples than the conventional electrode.

Acid-Base Titration. Sample

Quick Start Guide New Mountain Visit our Website to Register Your Copy (weatherview32.com)

REVIEW OF LAB TECHNIQUES

Conductivity Probe (Order Code CON-BTA)

Evaluation copy. Acids and Bases. computer OBJECTIVES MATERIALS

Operation Manual. SPECTRO-NANO4 Nucleic Acid Analyzer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

PRELIMINARY ACTIVITY FOR

Hydration of Propionaldehyde by Temperature-Jump Relaxation 1

Spring Thing: Newton s Second Law. Evaluation copy

CHEMISTRY SEMESTER ONE

Order of a Reaction. Using Labquest and Colorimeter. Teachers Guide

Experiment 13. Dilutions and Data Handling in a Spreadsheet rev 1/2013

Evaluation copy. Momentum: A Crash Lesson. computer OBJECTIVES MATERIALS

Determination of the Rate of a Reaction, Its Order, and Its Activation Energy

Microscale Acid-Base Titration

Energy of a Tossed Ball. Evaluation Copy. Motion Detector. Figure 1. volleyball, basketball, or other similar

Optical density measurements automatically corrected to a 1-cm pathlength with PathCheck Technology

Concentrations that absorb. Measuring percentage transmittance of solutions at different concentrations

Enzyme kinetics of Turnip Peroxidase

Diffusion through Membranes. Evaluation copy. dialysis tubing, 2.5 cm 12 cm

2. To measure the emission lines in the hydrogen, helium and possibly other elemental spectra, and compare these to know values.

Quantum States and Spectra of Gases

Energy Storage and Transfer: Gravitational Energy. Evaluation copy. Vernier Photogate (Extension only)

Determination of an Equilibrium Constant

Experiment 4 Radiation in the Visible Spectrum

Handleiding Vernier Radiation monitor

Lab 5: Calculating an equilibrium constant

CH 112 Special Assignment #4 Chemistry to Dye for: Part C

Software BioScout-Calibrator June 2013

DETERMINATION OF AN EQUILIBRIUM CONSTANT

Evaluation copy. First-Class Levers. computer OBJECTIVES MATERIALS

Spectroscopy II Introduction: Spectrophotometry and Fluorometry

Weather Stations. Evaluation copy. 9. Post live weather data on the school s web site for students, faculty and community.

Computer 3. Lifetime Measurement

Evaluation copy. Transpiration. Computer OBJECTIVES

Work and Energy. This sum can be determined graphically as the area under the plot of force vs. distance. 1

Chemical Equilibrium: Finding a Constant, Kc

Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III)

Biology Unit 2, Structure of Life, Lab Activity 2-2

KINETICS OF THE PERMANGANATE- ISOPROPYL ALCOHOL REACTION

Spectrum 22ED Spectrophotometer #FOT Absorbency 0A to 1.99A Photometric accuracy 2.0% T Power requirement 115/230 VAC; Hz automatic Size

Newton s Third Law. Evaluation copy

DIFFUSION THROUGH MEMBRANES STANDARDS B C.4 INTRODUCTION

Chemical Equilibrium: Finding a Constant, Kc

Chemical Equilibrium: Finding a Constant, Kc

Chemistry MultiMeasure Sensor PS-2170

Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III)

WeatherHawk Weather Station Protocol

UV-Vis optical fiber assisted spectroscopy in thin films and solutions

Rotary Motion Sensor

Introduction. Concepts Kinetics Order of reaction Reaction rate Colorimetry. Background

Transcription:

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS) The UV-VIS spectrometer is a portable ultraviolet light and visible light spectrophotometer, combining a spectrometer and a light source/cuvette holder. The light source/cuvette holder may be detached and an optical fiber assembly attached to the spectrometer for emission spectrum experiments. What is included with the UV-VIS Spectrometer? One spectrometer with light source/cuvette holder (Ocean Optics Red Tide UV-VIS Spectrometer) AC power supply One package of 15 UV clear plastic cuvettes and lids One USB cable Important Note Logger Pro 3 (version 3.8.5 or newer) software is required. If you own a previous version of Logger Pro 3, you may upgrade the software free of charge. You need the LabQuest application version 1.1 or newer to use a LabQuest 2 or original LabQuest as a standalone device with a spectrometer. Visit http://www.vernier.com/labquest/updates NOTE: Vernier products are designed for educational use. Our products are not designed nor recommended for any industrial, medical, or commercial process such as life support, patient diagnosis, control of a manufacturing process, or industrial testing of any kind. Get Started Using an Ocean Optics Spectrometer with Your Computer 1. Install Logger Pro 3 software (version 3.8.5 or newer) on your computer before using an Ocean Optics spectrometer. 2. Connect the AC power supply to the light source/cuvette holder of the UV-VIS spectrometer. Important: The AC power must be connected before connecting to the USB port. 3. Connect the spectrometer to a powered USB port on the computer or a powered USB hub.

The first time you connect a spectrometer, your computer may ask you a few questions. Note: Do not go online for device drivers. The device drivers were installed when you installed Logger Pro 3. Windows computers (Windows XP or Vista) Follow the New Hardware Wizard instructions to download the drivers automatically. Macintosh computers (Mac OS 10.3 or newer) If it appears, follow the New Device instructions. 4. Start the Logger Pro 3 software on your computer. Calibrate the Spectrometer for Measuring Absorbance or %T 1. Allow the UV-VIS spectrometer to warm up for a minimum of ten minutes. 2. Fill a cuvette about ¾ full with distilled water, or the solvent being used in the experiment, to serve as the blank. After the spectrometer has warmed up, place the blank cuvette in the spectrometer. Align the cuvette so a clear side of the cuvette is facing the light source. 3. Choose Calibrate Spectrometer from the Experiment menu. Follow the instructions in the dialog box to complete the calibration. Click. Collect Data There are three general types of data collection that measure absorbance absorbance vs. wavelength which produces a spectrum, absorbance vs. concentration for Beer s law experiments, and absorbance vs. time for kinetics experiment. Measure the Absorbance Spectrum of an Aqueous Sample (Absorbance vs. Wavelength) 1. Fill a cuvette about ¾ full of a sample of the solution to be tested. Place the sample in the spectrometer and click. Click to end the data collection. 2. To store the spectrum data, choose Store Latest Run from the Experiment menu. Conduct a Beer s Law Experiment (Absorbance vs. Concentration) 1. Measure an absorbance spectrum as described above. 2. Click on the Configure Spectrometer Data Collection button,. 3. Click Abs vs. Concentration. The wavelength of the maximum absorbance will be automatically selected (λ max). Click to continue or click and select a wavelength on the graph or in the list of wavelengths. 4. Place your first Beer s law standard solution in the spectrometer. Click and then click. Enter the concentration of the sample and click. Repeat this step for the remaining standard samples. Click to end the data collection. 5. Click linear fit,, to see the function for the standard solutions. 6. Place an unknown sample of solution in the spectrometer. Choose Interpolation Calculator from the Analyze menu. A helper box will appear, displaying the absorbance and concentration of the unknown. Click. 2

Conduct a Kinetics Experiment (Absorbance vs. Time) 1. Measure an absorbance spectrum as described above. 2. Click on the Configure Spectrometer Data Collection button,. 3. Click Abs vs. Time. The wavelength of maximum absorbance will be selected as before. Click to continue or click and select a wavelength on the graph or in the list of wavelengths. 4. The default settings are 1 sample per second for 200 seconds. To change the data-collection parameters for your experiment, choose Data Collection from the Experiment menu and make the necessary changes. Click. 5. Mix the reactants. Transfer ~2 ml of the reaction mixture to a cuvette and place the cuvette in the spectrometer. Click. Click if you wish to end the data collection early. 6. Click Curve Fit,, to calculate a function for your data. Using the Spectrometer to Measure Emission Spectra You may use your spectrometer to measure the emission spectrum of a light source such as an LED or a gas discharge tube. To do so, you may want to purchase an optical fiber assembly (order codes: UV-VIS). Measure an Emission Spectrum 1. Use a small screwdriver to loosen the two screws that connect the cuvette holder to the spectrometer (see Figure 1). Remove the cuvette holder and connect an optical fiber assembly to the spectrometer. Figure 1 2. Use a USB cable to connect the spectrometer to your computer. 3. Start Logger Pro 3. 4. Choose Change Units Spectrometer Intensity from the Experiment menu. Intensity is a relative measure. The spectrometer is not calibrated for measuring intensity. 5. Aim the tip of the optical fiber cable at a light source. Click. Click to end the data collection. If the spectrum maxes out (flat and wide peaks), increase the distance between the light source and the tip of the optical fiber cable or reduce the sample time. To adjust the data collection parameters, choose Set Up Sensors Spectrometer from the Experiment menu. Set the Sample Time to a suitable value and decrease the Samples 3

to Average to 1. Using the Stored Emissions Files in Logger Pro 3 Logger Pro 3 contains a folder of emissions graphs from selected discharge tubes, including: argon, helium, hydrogen, mercury, oxygen, sodium, and xenon. You can display and analyze these graphs without a spectrometer connected to your computer. Follow the steps below to view one of these graphs. 1. Choose Open from the File menu. 2. Open the Sample Data folder. 3. In the Sample Data folder, open the Physics folder. 4. In the Physics folder, open Gas Discharge Spectra. Open the desired file. Changing the Settings in Logger Pro 3 Spectrometer Dialog Box The Spectrometer dialog box lists all the settings for the device. To display this box choose Set Up Sensors Show All Interfaces from the Experiment menu. For most experiments, the default settings work well. There are four parameters listed in the dialog box. Sample Time: think shutter speed of a camera. Logger Pro 3 automatically selects the proper sample time during calibration. Note: For emission studies, you may need to change the sample time manually. Wavelength Smoothing: the number of adjacent readings on either side of a given value that is used to calculate an average value. Samples to Average: the number of readings taken at a given wavelength to calculate an average reading. Wavelength Range: the range is determined by the type of spectrometer in use. By clicking on the picture of the spectrometer in this dialog box, you will gain access to four options: calibrate, configure data collection, go to support web page, and units of measure. Click on an item to select it. Configure Spectrometer Data Collection Dialog Box To display this box, click on the Configure Data Collection button,. There are three regions in this box and four buttons at the bottom. Graph The graph displays a full spectrum analysis of your sample. By default, the wavelength of greatest absorbance (λ max) will be marked with a box. You may select other wavelengths by clicking on the plot at the desired wavelength. Set Collection Mode Three options for data collection are offered. Full Spectrum/Select Wavelength This column of the available wavelengths becomes active when you select Abs vs. Concentration or Abs vs. Time. Check the box for each wavelength you wish to use in an experiment. When you select a wavelength from the list, a box appears on the graph. Use the button to remove all of the wavelengths selected on the graph. Determining the Wavelength(s) to Use in an Experiment When you conduct a Beer s law lab or a kinetics lab, it is common to select one 4

wavelength at which to follow the experiment. However, in Logger Pro 3 you may select as many wavelengths as you wish. There are two ways to select the wavelength or wavelengths. 1. Perform a Full Spectrum Analysis of the Solution to Be Tested Measure the full spectrum of a sample of solution and then click Configure Spectrum Data Collection ( ). Select Abs vs. Concentration or Abs vs. Time. The wavelength of maximum absorbance (λ max) will be automatically selected. 2. Use a Sample of Solution to Determine the Peak Absorbance This is a variation of the previous method. After calibrating the Spectrometer, place a sample of solution in the Spectrometer and then click Configure Spectrum Data Collection ( ). Select Abs vs. Time or Abs vs. Concentration. The wavelength of maximum absorbance (λ max) will be automatically selected. If you don t want to use the λ max, click and select a wavelength on the graph or in the list of wavelengths. Selecting a Range of Wavelengths to Use in an Experiment You may wish to measure the absorbance or %T of a sample over a group of wavelengths rather than a single wavelength. There are two ways to select a group of wavelengths from the Configure Spectrum Data Collection dialog box. Select the wavelengths one at a time by checking the boxes in the Select Wavelength column. Left click on the graph and drag your cursor across the region of wavelengths to analyze. Check the Treat Contiguous Wavelengths as a Single Range box. Measurement You can set up the spectrometer to measure intensity, absorbance, or % transmittance. Choose Change Units Spectrometer from the Experiment menu. Click on the unit of choice from the list. Using an Ocean Optics Spectrometer with a LabQuest 2 or Original LabQuest 1. Connect the AC power supply to the spectrometer. 2. Use the USB cable to connect the spectrometer to a LabQuest 2 or LabQuest. Allow the spectrometer to warm up for fifteen minutes. 3. Turn on the LabQuest 2 or LabQuest. The LabQuest app will launch automatically and the meter screen will be displayed. Calibrate the Spectrometer 1. Fill a cuvette about ¾ full with distilled water and place it in the spectrometer. Align the cuvette so a clear side of the cuvette is facing the light source. 2. Choose Calibrate USB:Spectrometer from the Sensors menu. At the prompt, select Finish Calibration. After the message Calibration Completed appears, select. 5

Measure the Absorbance Spectrum of an Aqueous Sample (Absorbance vs. Wavelength) 1. Fill a cuvette about ¾ full of the solution to be tested and place it in the spectrometer. 2. Start the data collection. Tap the red Stop button to end the data collection. 3. Note: The wavelength of maximum absorbance (λ max) is automatically selected. This λ max will be used for any subsequent data collection, such as a Beer s Law experiment (abs vs. conc.) or a kinetics experiment (abs. vs. time). If you wish to choose another wavelength, you can tap on the graph to select a new wavelength or you can used the arrow keys on the keypad to move the cursor to a new wavelength. Conduct a Beer s Law Experiment (Absorbance vs. Concentration) 1. Measure an absorbance spectrum as described above. On the Meter screen, tap Mode. Change the mode to Events with Entry. 2. Enter the Name (Concentration) and Units (mol/l). Select OK. 3. A message will appear warning you to either save or discard the full spectrum run. Make your choice and proceed with the data collection. 4. Place your first Beer s law standard solution in the spectrometer. Start data collection. After the absorbance reading stabilizes, tap Keep. Enter the concentration of the solution and select OK. 5. Place your second standard sample in the spectrometer. After the absorbance readings stabilize, tap Keep. Enter the concentration of the second sample and select OK. 6. Repeat Step 5 for the remaining standard samples. After you have tested the final standard, tap the red Stop button to end the data collection. 7. To calculate a best fit line equation for your standards, choose Curve Fit from the Analyze menu. Select Linear for the Fit Equation, and then select OK. The graph screen will appear again with the linear regression equation displayed. 8. Place a cuvette containing an unknown sample of solution in the spectrometer. Tap the Meter tab and write down the displayed absorbance value. Tap the graph tab and trace the linear regression equation to determine the concentration of the unknown. Conduct a Kinetics Experiment (Absorbance vs. Time) 1. Measure an absorbance spectrum as described above. On the Meter screen, tap Mode. Change the data-collection mode to Time Based. 2. You can change the rate, interval, and/or length of time of data collection, if desired. Select OK when you are ready to proceed. 3. A message will appear warning you to either save or discard the full spectrum run. Make your choice and proceed with data collection. 4. Mix the reactants, transfer ~2 ml of the reaction mixture to a cuvette and place the cuvette in the spectrometer. Start the data collection. You may tap the red Stop button to end the data collection early. 6

5. To calculate a function for your data, choose Curve Fit from the Analyze menu. Select the Fit Equation, and then select OK. The graph screen will appear again. Measure an Emission Spectrum 1. Use a small screwdriver to loosen the two screws that connect the cuvette holder to the Spectrometer (see Figure 1). Remove the cuvette holder and connect an optical fiber assembly to the spectrometer. 2. Turn on the LabQuest 2 or LabQuest. The LabQuest App will launch automatically and the meter screen will be displayed. 3. On the meter screen, tap Change Units USB:Spectrometer Intensity from the Sensors menu. The spectrometer measures intensity in relative units. 4. Aim the tip of the optical fiber cable at a light source. Start the data collection. Tap the red Stop button to end the data collection. If the spectrum maxes out (flat and wide peaks), increase the distance between the light source and the tip of the optical fiber cable or reduce the sample time. To adjust the data collection parameters, tap Sensors and choose Data Collection. Set the Sample Time to a suitable value and decrease the Samples to Average to 1. Determining the Wavelength to Use in an Experiment After you collect a full absorbance spectrum of a sample, LabQuest 2 or LabQuest will identify the wavelength of maximum absorbance (λ max). If you wish to select a different wavelength, tap on the full spectrum graph or use the arrow keys on the keypad to identify the wavelength of choice. Another way to change the wavelength is to navigate to the meter screen, tap on the meter itself, and select Change Wavelength. Enter the wavelength of your choice and select OK. If the wavelength you type in is not measured by the UV-VIS unit, LabQuest 2 or LabQuest will automatically choose the wavelength closest to your choice. Measurement You can set up the spectrometer to measure intensity, absorbance, or % transmittance. On the Meter screen, choose Change Units from the Sensors menu. Click on the unit of choice from the list. Sample Experiments There are several experiments available for use with the spectrometer. You may download the labs from our web site (www.vernier.com/spectroscopy). Specifications Ocean Optics UV-VIS Spectrometer (order code: SP-UV-VIS) Dimensions: 14.2 cm 8.7 cm 3 cm (includes cuvette holder/light source) Power: AC adapter (included) Light Source: integrated deuterium tungsten halogen light source Wavelength Range: 200 nm 850 nm Pixel Resolution: 0.2 nm Ocean Optics Red Tide UV-VIS Spectrometer (order code: SPRT-UV-VIS) Dimensions: 14.2 cm 8.7 cm 3 cm (includes cuvette holder/light source) 7

Power: AC adapter (included) Light Source: integrated deuterium tungsten halogen light source Wavelength Range: 200 nm 850 nm Pixel Resolution: 1 nm Warranty Vernier warrants this product to be free from defects in materials and workmanship for a period of three years from the date of shipment to the customer. This warranty does not cover damage to the product caused by abuse or improper use. Bulbs for the light source are covered by a one-year warranty. This product is manufactured by Ocean Optics, Inc. Vernier Software & Technology 13979 S.W. Millikan Way Beaverton, OR 97005-2886 Toll Free (888) 837-6437 (503) 277-2299 FAX (503) 277-2440 info@vernier.com www.vernier.com Rev. 6/18/2012 Logger Pro, Vernier LabQuest 2, Vernier LabQuest, and other marks shown are our trademarks or registered trademarks in the United States. All other marks not owned by us that appear herein are the property of their respective owners, who may or may not be affiliated with, connected to, or sponsored by us. Sole Australian distributor: Scientrific Pty Ltd www.scientrific.com.au Ph: 02 6645 8111 Fax: 02 6645 8125 8