THE EFFECTIVENESS OF RECTANGULAR BLOCK AS ENERGY DISSIPATION STRUCTURE ADAM BIN ISMAIL B.ENG (HONS.) CIVIL ENGINEERING UNIVERSITI MALAYSIA PAHANG

Similar documents
Closed duct flows are full of fluid, have no free surface within, and are driven by a pressure gradient along the duct axis.

Cavitation occurs whenever the pressure in the flow of water drops to the value of the pressure of the saturated water vapour, pv (at the prevailing

1.060 Engineering Mechanics II Spring Problem Set 8

Chapter 3.8: Energy Dissipators. By Dr. Nuray Denli Tokyay

Closed duct flows are full of fluid, have no free surface within, and are driven by a pressure gradient along the duct axis.

NUMERICAL INVESTIGATION OF TURBULENT NANOFLUID FLOW EFFECT ON ENHANCING HEAT TRANSFER IN STRAIGHT CHANNELS DHAFIR GIYATH JEHAD

EFFECT OF NOZZLE ANGLE ON JET IMPINGEMENT COOLING SYSTEM KHAIDER BIN ABU BAKAR

ERODABLE DAM BREACHING PATTERNS DUE TO OVERTOPPING NOR AIN BINTI MAT LAZIN UNIVERSITI TEKNOLOGI MALAYSIA

Open Channel Flow Part 2. Ch 10 Young, notes, handouts

Hydraulics Prof. Dr. Arup Kumar Sarma Department of Civil Engineering Indian Institute of Technology, Guwahati

THE EFFECT OF PLATE GEOMETRY ON FLOW AND HEAT TRANSFER ACROSS A PARALLEL PLATE HEAT EXCHANGER

Rock Sizing for Waterway & Gully Chutes

Rock Sizing for Small Dam Spillways

A COMPUTATIONAL FLUID DYNAMIC FRAMEWORK FOR MODELING AND SIMULATION OF PROTON EXCHANGE MEMBRANE FUEL CELL HAMID KAZEMI ESFEH

THE DEVELOPMENT OF PORTABLE SENSOR TO DETERMINE THE FRESHNESS AND QUALITY OF FRUITS USING CAPACITIVE TECHNIQUE LAI KAI LING

NPTEL Quiz Hydraulics

EFFECT OF BAFFLE BLOCKS ON THE PERFORMANCE OF RADIAL HYDRAULIC JUMP

COMPUTATIONAL STUDY OF TURBULENT UNCONFINED SWIRL FLAMES ANIS ATHIRAH BINTI MOHD AZLI

Rock Sizing for Batter Chutes

Keywords: flow characteristics, compound straight channel, bed morphology, floodplain

INDIRECT TENSION TEST OF HOT MIX ASPHALT AS RELATED TO TEMPERATURE CHANGES AND BINDER TYPES AKRIMA BINTI ABU BAKAR

STABILITY AND SIMULATION OF A STANDING WAVE IN POROUS MEDIA LAU SIEW CHING UNIVERSTI TEKNOLOGI MALAYSIA

VARIED FLOW IN OPEN CHANNELS

OPEN CHANNEL FLOW. Computer Applications. Numerical Methods and. Roland Jeppson. CRC Press UNIVERSITATSB'BUOTHEK TECHNISCHE. INFORMATlONSBiBUOTHEK

DCC6213: HYDRAULICS & HYDROLOGY

Open Channel Flow I - The Manning Equation and Uniform Flow COURSE CONTENT

INFLUENCES OF GROUNDWATER, RAINFALL, AND TIDES ON BEACH PROFILES CHANGES AT DESARU BEACH FARIZUL NIZAM BIN ABDULLAH

Hydraulics for Urban Storm Drainage

Presented by: Civil Engineering Academy

Lecture Note for Open Channel Hydraulics

DEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING Urban Drainage: Hydraulics. Solutions to problem sheet 2: Flows in open channels

EFFECTS OF SURFACE ROUGHNESS USING DIFFERENT ELECTRODES ON ELECTRICAL DISCHARGE MACHINING (EDM) MOHD ABD LATIF BIN ABD GHANI

ARTIFICIAL NEURAL NETWORK AND KALMAN FILTER APPROACHES BASED ON ARIMA FOR DAILY WIND SPEED FORECASTING OSAMAH BASHEER SHUKUR

Hydraulic Design of Energy Dissipators for Culverts and Channels HEC 14 September 1983 Metric Version

ANOLYTE SOLUTION GENERATED FROM ELECTROCHEMICAL ACTIVATION PROCESS FOR THE TREATMENT OF PHENOL

Influence of Two-line Emergent Floodplain Vegetation on A Straight Compound Channel Flow

FACULTY OF CHEMICAL & ENERGY ENGINEERING FLUID MECHANICS LABORATORY TITLE OF EXPERIMENT: MINOR LOSSES IN PIPE (E4)

OPEN CHANNEL FLOW. One-dimensional - neglect vertical and lateral variations in velocity. In other words, Q v = (1) A. Figure 1. One-dimensional Flow

Guo, James C.Y. (1999). "Critical Flow Section in a Collector Channel," ASCE J. of Hydraulic Engineering, Vol 125, No. 4, April.

HYDROGEN RECOVERY FROM THE REFORMING GAS USING COMMERCIAL ACTIVATED CARBON MEHDI RAHMANIAN

FE Fluids Review March 23, 2012 Steve Burian (Civil & Environmental Engineering)

Hydraulics Part: Open Channel Flow

DEMULSIFICATION OF CRUDE OIL EMULSIONS VIA MICROWAVE ASSISTED CHEMICALS (ENVIRONMENTAL FRIENDLY) NUR HAFIZAH BINTI HUSSIN

MATHEMATICAL MODELLING OF UNSTEADY BIOMAGNETIC FLUID FLOW AND HEAT TRANSFER WITH GRAVITATIONAL ACCELERATION

Experiment 7 Energy Loss in a Hydraulic Jump

PART 2:! FLUVIAL HYDRAULICS" HYDROEUROPE

PLANNING AND DESIGN OF BARRAGE TYPE DIVERSION STRUCTURES ON BOULDERY RIVERS WITH STEEP GRADIENT M. M.

Hydromechanics: Course Summary

compare to Mannings equation

EXPERIMENTAL STUDY OF HEAT TRANSFER CHARACTERISTICS OF ROUND AIR JET IMPINGING ON CONVEX SURFACE HASAN ABDUALLATIF MUHALHAL

PIPE FLOW. The Energy Equation. The first law of thermodynamics for a system is, in words = +

MULTISTAGE ARTIFICIAL NEURAL NETWORK IN STRUCTURAL DAMAGE DETECTION GOH LYN DEE

Model for Dredging a Horizontal Trapezoidal Open Channel with Hydraulic Jump

A COMPARISO OF MODAL FLEXIBILITY METHOD A D MODAL CURVATURE METHOD I STRUCTURAL DAMAGE DETECTIO OOR SABRI A ZAHARUDI

CE 6403 APPLIED HYDRAULIC ENGINEERING UNIT - II GRADUALLY VARIED FLOW

Beaver Creek Corridor Design and Analysis. By: Alex Previte

The Hydraulics of Open Channel Flow: An Introduction

Jurnal Teknologi CHARACTERIZATION OF A SHORT MICROCHANNEL DEVICE FOR SURFACE COOLING. Full Paper. Kamaruzaman N. B *, Saat A.

CEE 3310 Open Channel Flow, Nov. 26,

MONTE CARLO SIMULATION OF NEUTRON RADIOGRAPHY 2 (NUR-2) SYSTEM AT TRIGA MARK II RESEARCH REACTOR OF MALAYSIAN NUCLEAR AGENCY

MOHAMAD HANIF BIN HAMZAH. A thesis submitted in fulfillment of the requirements for the award of the degree of B.ENG (HONS.) CIVIL ENGINEERING

Advanced Hydraulics Prof. Dr. Suresh A. Kartha Department of Civil Engineering Indian Institute of Technology, Guwahati

LECTURE 9: Open channel flow: Uniform flow, best hydraulic sections, energy principles, Froude number

P10.5 Water flows down a rectangular channel that is 4 ft wide and 3 ft deep. The flow rate is 15,000 gal/min. Estimate the Froude number of the flow.

U DVIVIDIV111 DV11111

MODELLING AND EXPERIMENTAL INVESTIGATION ON PERFORATED PLATE MOBILITY CHEAH YEE MUN UNIVERSITI TEKNIKAL MALAYSIA MELAKA

Porous Weirs for Flood Mitigation

ULTIMATE STRENGTH ANALYSIS OF SHIPS PLATE DUE TO CORROSION ZULFAQIH BIN LAZIM

Practical aspects of dam break analysis

Rock Sizing for Multi-Pipe & Culvert Outlets

Hydroelectric Design

Basic Hydraulics. Rabi H. Mohtar ABE 325

We will assume straight channels with simple geometries (prismatic channels) and steady state flow (in time).

STEADY UNIFORM FLOW IN OPEN CHANNEL

DEVELOP DRAG ESTIMATION ON HYBRID ELECTRIC VEHICLE (HEV) MODEL USING COMPUTATIONAL FLUID DYNAMICS (CFD) REDZUAN BIN AHMAD

INVESTIGATING THE EFFECT OF SOLID POWDER PARTICLE TYPE ON THE TURBULENT MULTIPHASE FLOW IN PIPELINES KOR YUE KIM

SEDIMENTATION RATE AT SETIU LAGOON USING NATURAL. RADIOTRACER 210 Pb TECHNIQUE

28.2 Classification of Jumps

SYSTEM IDENTIFICATION MODEL AND PREDICTIVE FUNCTIONAL CONTROL OF AN ELECTRO-HYDRAULIC ACTUATOR SYSTEM NOOR HANIS IZZUDDIN BIN MAT LAZIM

BUCKINGHAM PI THEOREM

DCC5143: FLUID MECHANICS

UNCERTAINTY ANALYSIS OF TWO-SHAFT GAS TURBINE PARAMETER OF ARTIFICIAL NEURAL NETWORK (ANN) APPROXIMATED FUNCTION USING SEQUENTIAL PERTURBATION METHOD

Application of Energy Approach to Estimating Scour Depth

Dr. Muhammad Ali Shamim ; Internal 652

OPTIMIZATION OF CHROMIUM, NICKEL AND VANADIUM ANALYSIS IN CRUDE OIL USING GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY NURUL HANIS KAMARUDIN

APPLIED FLUID DYNAMICS HANDBOOK

UNIFORM FLOW CRITICAL FLOW GRADUALLY VARIED FLOW

Formation Of Hydraulic Jumps On Corrugated Beds

Open Channel Hydraulics I - Uniform Flow

DYNAMIC SIMULATION OF COLUMNS CONSIDERING GEOMETRIC NONLINEARITY MOSTAFA MIRSHEKARI

Chapter 4: Non uniform flow in open channels

ENGINEERING PROPERTIES OF OLDER ALLUVIUM BADEE ABDULQAWI HAMOOD ALSHAMERI. Universiti Teknologi Malaysia

FORMATION OF HYDRAULIC JUMPS ON CORRUGATED BEDS

BERNOULLI EQUATION. The motion of a fluid is usually extremely complex.

Lateral Inflow into High-Velocity Channels

EAH 225 / JAH 331/3 - Hydraulics

MODELING AND SIMULATION OF BILAYER GRAPHENE NANORIBBON FIELD EFFECT TRANSISTOR SEYED MAHDI MOUSAVI UNIVERSITI TEKNOLOGI MALAYSIA

Chapter (3) Water Flow in Pipes

NUMERICAL SIMULATIONS ON THE EFFECTS OF USING VENTILATION FAN ON CONDITIONS OF AIR INSIDE A CAR PASSENGER COMPARTMENT INTAN SABARIAH BINTI SABRI

MODELING AND CONTROLLER DESIGN FOR AN INVERTED PENDULUM SYSTEM AHMAD NOR KASRUDDIN BIN NASIR UNIVERSITI TEKNOLOGI MALAYSIA

Transcription:

THE EFFECTIVENESS OF RECTANGULAR BLOCK AS ENERGY DISSIPATION STRUCTURE ADAM BIN ISMAIL B.ENG (HONS.) CIVIL ENGINEERING UNIVERSITI MALAYSIA PAHANG

VI ABSTRACT Velocity of flow water in a channel will increase when there are different between water level at upstream and downstream of a channel. High velocity of flow water can be possessed by water flow in a spillway which the flow is caused by the gravitational force. High water flow velocity can caused bad impacts such as erosion, scour, sedimentation and cavitations around spillway toe, weir bed and downstream of river. In order to overcome these problems, the flow velocity has to be reduced. This can be done through constructing an energy dissipating structure at the affected areas. Therefore, a rectangular open channel model structure consists of spillway part is constructed and used to conduct an experiment to study the performances and effectiveness of rectangular concrete block as a energy dissipation structure. The blocks used in this study have different size and different slope of spillway. The blocks are arranged in various pattern of arrangements in stilling basin of a channel. For blocks size 30 x 25 x 23 mm with slope 27 0, the best pattern with a highest percentages reduction in velocity is pattern 5. For blocks size 30 x 30 x 30 mm with slope 270, the best pattern with a highest percentages reduction in velocity is pattern 5. Based from the result, its shows that the decrease of slope will be increase the percentage reduction in velocity.

VII ABSTRAK Halaju aliran air dalam saluran yang akan meningkat apabila terdapat perbezaan di antara paras air di hulu dan hilir saluran. Halaju aliran yang tinggi disebabkan oleh aliran air di alur limpah yang mana aliran disebabkan oleh daya graviti. Halaju aliran air yang tinggi boleh menyebabkan kesan buruk seperti hakisan, kerosakan dan pemendapan sekitar alur limpah dan hilir sungai. Untuk mengatasi masalah ini, halaju aliran yang telah dikurangkan. mi boleh dilakukan melalui pembinaan struktur pelesap tenaga di kawasan yang terlibat. Oleh itu, satu struktur model saluran segi empat tepat terdiri daripada bahagian alur limpah dibina dan digunakan untuk menjalankan satu eksperimen untuk mengkaji prestasi dan keberkesanan blok konkrit segi empat tepat sebagai struktur pelesapan tenaga. Blok-blok yang digunakan dalam kajian mi mempunyai saiz yang berbeza dan cerun alur limpah yang berbeza. Blok-blok disusun dalam pelbagai corak pengaturan dalam lembangan penenang saluran. Untuk blok bersaiz 30 x 25 x 23 mm dengan cerun 27, corak yang terbaik dengan pengurangan peratusan yang tertinggi dalam halaju adalah corak 5. Untuk blok bersaiz 30 x 30 x 30 mm dengan cerun 27, corak yang terbaik dengan pengurangan peratusan yang tertinggi dalam halaju adalah corak 5. Berdasarkan keputusan itu, menunjukkan bahawa penurunan cerun akan meningkatkan peratus pengurangan halaju.

VIII TABLE OF CONTENT Page STATUS VALIDATION 1 SUPERVISOR'S DECLARATION STUDENT'S DECLARATION DEDICATION iv ACKNOLEWDGEMENT v ABSTRACT vi ABSTRAK vii TABLE OF CONTENTS viii LIST OF TABLES xi LIST OF FIGURES xii LIST OD SYMBOLS xiv LIST OF ABBREVIATION xvi LIST OF APPENDICES xvii CHAPTER I INTRODUCTION 1.1 Background of Study 1 1.2 Problem Statement 2 1.3 Objectives 2 1.4 Scope of Study 3 1.5 Significant of Study 3 1.6 Expected Result 3 CHAPTER II LITERATURE REVIEW 2.1 Spillways 5 2.2 Froude Number (Fr) 7 2.3 Specific Energy (E) 8

ix 2.4 Reynolds Number (Re) 10 2.5 Manning's Equation 11 2.5.1 Manning's Roughness Coefficient 12 2.6 Hydraulic Jump 13 2.6.1 Types of Hydraulic Jump 14 2.6.2 Hydraulic Jump in Sloping Channels 17 2.7 Energy Dissipater 19 2.7.1 Stilling Basin 19 2.7.1.1 United States Bureau of Reclamation 20 (USBR) Stilling Basin 2.7.2 Stepped Spillways 21 2.7.3 Trajectory Buckets 23 2.7.4 Baffled Apron Drops 26 CHAPTER III METHODOLOGY 3.1 Introduction 28 3.2 Flow Chart of Project Methodology 28 3.3 Open Channel Model Structure Selection 30 3.4 Research Parameter Selection 30 3.5 Energy Dissipater Model Structure 31 3.6 Discharge and Velocity Measurement 32 3.7 Water Depth Measurement 34 3.8 Arrangement and Position of the Energy 35 Dissipater Structure 3.9 Procedure of the Experiment 38 3.10 Assumption in the Experiment 39 CHAPTER lv RESULT AND DISCUSSION 4.1 Introduction 40 4.2 Measurement of Flow Depth, y and 40

x Flow Velocity, v 4.3 Data Collection 42 4.4 Result for Rectangular Concrete Blocks 43 Energy Dissipaters with Size 30x25x23 mm 4.5 Result for Rectangular Concrete Blocks 45 Energy Dissipaters with Size 30 x 30 x 30 mm 4.6 Results for Different Slope 48 4.7 Discussion 51 4.7.1 Discussion for Various Arrangement at 52 Stilling Basin 4.7.2 Discussion for Different Size of 54 Energy Dissipaters 4.7.3 Discussion for Different Slope 59 CHAPTER V CONCLUSION AND RECOMENDATION 5.1 Conclusion 61 5.2 Problem Encountered 62 5.3 Recommendations 63 REFERENCES 64 APPENDIX 66

xl LIST OF TABLES Table No. Title Page 2.1 Manning Roughness Coefficient Values 13 2.2 Classification of Hydraulic Jump According to Froude Number 17 4.1 Initial velocity 41 4.2 Example of Data for Flow Velocity after Locating 44 Pattern 1 Concrete Blocks 4.3 Comparison of Percentage of Reduction in Flow Velocity after 45 Locating Rectangular Concrete Blocks in Various Arrangements at Stilling Basin 4.4 Example of Data for Flow Velocity after Locating Pattern 1 47 Concrete Blocks 4.5 Comparison of Percentage of Reduction in Flow Velocity after 48 Locating Rectangular Concrete Blocks in Various Arrangements at Stilling Basin 4.6 Example of Data for Flow Velocity after Locating Pattern 1 50 Concrete Blocks with 4.7 Comparison of Percentage of Reduction in Flow Velocity after 51 -Using Slope at- Spillways 270 and 15 0 for Size 30 x 25 x 23 mm and 30 x 30 x 30 mm 4.8 Number of concrete blocks for each pattern 53

XII LIST OF FIGURES Figure No. Title Page 2.1 Main Spillway of Oldman Dam, Alberta 5 2.2 B.Everett Jordan Dam and Shaft Spillway, 6 Haw River Chatham Contry, N.0 2.3 A spillway bucket of Anderson Dam, California 7 2.4 Specific Energy Diagram 9 2.5 Phenomenon of Hydraulic Jump at Bottom of the Spillway 14 2.6 Jump forms related ton Froude Number (USBR) 15 2.7 Hydraulic Jump Types Sloping Channels 18 2.8 Skimming Flow Regime 23 2.9 Ski Jump Buckets 24 2.10 Flip Buckets 24 2.11 Free Jet Spillway 25 2.12 Flip Bucket at Glen Canyon Dam, Arizona 26 2.13 Baffled Apron Drop 27 3.1 Methodology of Study 29 3.3 Rectangular Concrete Blocks 32 3.4 Measurement of Cross Section Area, A 34 3.5 Arrangement of Pattern 1 35 3.6 Arrangement of Pattern 2 36 3.7 Arrangement of Pattern 3 36

XIII 3.8 Arrangement of Pattern 4 37 3.9 Arrangement of Pattern 5 37 4.1 Location of the data taken from conducted experiment 42 4.2 Graph Percentage of Reduction in Flow Velocity versus 52 Number of Row for Size 30 x 25 x 23 mm 4.3 Graph Percentage of Reduction in Flow Velocity versus 52 Number of Row for Size 30 x 30 x 30 mm 4.4 Different Pattern 2 and Pattern 5 53 4.5 Graph for different size of energy dissipater for Pattern 1 54 4.6 Graph for different size of energy dissipater for Pattern 2 55 4.7 Graph for different size of energy dissipater for Pattern 3 56 4.8 Graph for different size of energy dissipater for Pattern 4 57 4.9 Graph for different size of energy dissipater for Pattern 58 4.10 Graph for using different slope for size 30 x 25 x 23 mm 59 4.11 Graph for using different slope for size 30 x 30 x 30 mm 60

xiv LIST OF SYMBOLS Symbol v V0 y Yo Q D g P P Y Item - velocity - initial velocity - Measured flow depth - Initial velocity - Flow rate - Hydraulic depth - Gravity - Density of the fluid - Viscosity of fluid - Unit weight of water ( - Angle of channel with the horizontal S R P A m mm m3/s m/s 2 m - Bottom of slope channel - Hydraulic radius - Wetted parameter - Area of hydraulic section - Meter - Millimeter - Meter cubes per second - Meter per second - Meter square

E - Specific Energy B - Width of channel Fr - Froude number Av - Reduction in flow velocity

xvi LIST OF ABBREVATIONS USBR - United States Bureau of Reclamation MSMA - Manual Saliran Mesra Alam

xvii LIST OF APPENDICES APPENDIX TITLE PAGE Al Arrangement of concrete blocks at stilling basin 66 B! Recorded Data For Flow Velocity After Locating Rectangular 69 Concrete Blocks In Pattern 1 Arrangement At Stilling Basin B2 Recorded Data For Flow Velocity After Locating Rectangular 70 Concrete Blocks In Pattern 2 Arrangement At Stilling Basin. B3 Recorded Data For Flow Velocity After Locating Rectangular 70 Concrete Blocks In Pattern 3 Arrangement At Stilling Basin B4 Recorded Data For Flow Velocity After Locating Rectangular 71 Concrete Block In Pattern 4 Arrangement At Stilling Basin B5 Recorded Data For Flow Velocity After Locating Rectangular 71 Concrete Blocks In Pattern 5 Arrangement At Stilling Basin Cl Recorded Data For Flow Velocity After Locating Rectangular 72 Concrete Blocks In Pattern 1 Arrangement At Stilling Basin C2 Recorded Data For Flow Velocity After Locating Rectangular 73 Concrete Blocks In Pattern 2 Arrangement At Stilling Basin C3 Recorded Data For Flow Velocity After Locating Rectangular 73 Concrete Blocks In Pattern 3 Arrangement At Stilling Basin C4 Recorded Data For Flow Velocity After Locating Rectangular 74 Concrete Blocks In Pattern 4 Arrangement At Stilling Basin CS Recorded Data For Flow Velocity After Locating Rectangular 74 Concrete Blocks In Pattern 5 Arrangement At Stilling Basin Dl Recorded data for flow velocity after using slope 15 0 in 75 Pattern 5 arrangement at stilling basin for first try D2 Recorded data for flow velocity after using slope 15 0 in 76 Pattern 5 arrangement at stilling basin for second try D3 Recorded data for flow velocity after using slope 15 0 in 76 Pattern 5 arrangement at stilling basin for third try

XVIII El Recorded data for flow velocity after using slope 15 0 in 77 Pattern 5 arrangement at stilling basin for first try E2 Recorded data for flow velocity after using slope 15 0 in 78 Pattern 5 arrangement at stilling basin for second try E3 Recorded data for flow velocity after using slope 150 in 78 Pattern 5 arrangement at stilling basin for third try

CHAPTER I INTRODUCTION 1.1 BACKGROUND OF STUDY Energy dissipation are devices designed to protect downstream areas from erosion by reducing the velocity of flow to acceptable limits. According to MASMA, energy dissipaters are usually required where the flow regimes change from supercritical to subcritical, or where the flow is supercritical and the tractive forces or flow velocities are higher than the maximum allowable values. Energy dissipater is a device located in the base of a channel of flow water which used to dissipate the energy of the flow. The energy dissipation structure reduces velocity of flow water by spreading the water flow over a large area and to protect the structure and adjacent area from excessive damage due to erosion. Energy dissipaters can be constructed in several forms and from different materials including rocks, gabion, logs, steel baffles and concrete blocks. Although there are various type of devices that can be used as energy dissipater structure, the concept are that the dissipation of energy is through internal friction and turbulence or impact and diffusion of the high velocity flow in the mass of water.

2 Energy dissipation should be considered part of the larger design system which includes the culvert and channel protection requirements (upstream and downstream) and may include a debris control structure. The interrelationship of these various components must be considered in designing any one part of the system. The best conveys from the upstream into the downstream involves number of hydraulic phenomena. The transition from supercritical to subcritical flow occurred when water flow from spillway (upstream) into the stilling basin (downstream). In this condition, the velocity of flow water need to be concerned and controlled. 1.2 PROBLEM STATEMENT Energy of water flowing down from a high altitude slope area will experience increase of kinetic energy. This kinetic energy can be correlated to the velocity of flow. As water approaches downstream, the velocity will increase and induces erosion to river and scouring downstream of river. Spillway, weir and dams are man-made structure built to deal with scour, cavitations and erosion problems caused by the high water velocity flow. Due to this, studies need to be conducted to protect and preserve the environment and hydraulic structure itself. 1.3 OBJECTIVES The objectives of this study are: i. To determine and analyze the performance of selected Energy Dissipation Structure at stilling basin. ii. To identify the most effective of selected Energy Dissipation Structure at stilling basin.

3 iii. To analyze the performance of Energy Dissipation Structure at spillway and stilling basin using different slope of spillway. 1.4 SCOPE OF STUDY A prototype model of an open channel consist of spillway and stilling basin is constructed in laboratory for testing purpose. The water flow through the rectangular crosssection model indicates the actual flow of water from the reservoir or high altitude slope area where the energy dissipation can be observed and studied. Study scopes that have been fixed are: i. Experiment is conducted in Hydraulic & Hydrology Laboratory of Faculty of Civil Engineering & Earth Resources, Universiti Malaysia Pahang. ii. The model structure associated with a spillway and stilling basin area. iii. Limited to (30cm x 50cm) rectangular cross section open channel of a certain fix gradient (27 ). iv. Take into account of various size of concrete block (30 x 25 x 23 mm and 30 x 30 x 30 mm) and arrangement of Energy Dissipater Structure to obtain the most effective design. 1.5 SIGNIFICANT OF STUDY Based from this study, the best arrangement of concrete block design with the best types of roughness can be identified based on their performance. It will helps for prevent erosion, sedimentation, cavitations and scour problem in open channel. 1.6 EXPECTED RESULT The best performance and effective design of Energy Dissipation structure will be determined

CHAPTER II LITERATURE REVIEW 2.1 SPILLWAYS Spillways (dams) is a structure which passes floodwater through, over or around a dam. Provision is usually made to prevent scour and the removal of rock at the downstream face of the dam by spillway discharges. This may consist of a concrete apron at the toe or other construction in the design of spillway (Nelson and Ken, 2005). Figure 2.1 shows a typical spillway of Oldman Dam at Canada which assigned to pass flood flows, thereby preventing overtopping and failure of the dam. Aside its principal function of passing down the surplus water from the reservoir into the downstream river, other particular functions that related to spillway are discharging water for utilization, maintaining initial water level in the flood-control operation, and lowering water levels in an emergency.

5 Figure 2.1: Main Spillway of Oldman Dam, Alberta (wwww.uleth.ca, 1999) In spillways design, there were numbers of considerations that need to be considered which includes hydraulic considerations, topography, geology, type of the dam, layout of other asociated structure, economic comparison, frequency of usage, as well as special and environment considerations. For instance, the topography that favors the selection of shaft spillways or a tunnel spillway will most likely be an ideal site for a flip bucket. Figure 2.2 shows example of Shift spillway at North Carolina which can be described as a vertical shaft having a funnel-shaped entrance and ending in an outlet tunnel that provides an outflow from a reservoir.

6 - -._- I I Figure 2.2: B.Everett Jordan Dam and Shaft Spillway, Haw River Chatham Contry, N.0 (www.ncwater.org, 1994) Flip buckets are commonly used to discharge flow away from a hydraulic structure into a plunge pool to dissipate energy. For the gravity or arch dams in steep and narrow canyons, ski jump buckets would be preferable. An example of spillway flip bucket is shown in Figure 2.3 which is located at Anderson Dam, California.

7 - - Figure 2.3: A spillway bucket of Anderson Dam, California (terramaterang.com,2007) 2.2 FROUDE NUMBER (Fr) The Froude number, Fr, is a dimensionless value that describes different flow regimens of open channel flow. The Froude number is a ratio of inertia and gravitational forces. Because of the free surface, gravity is the driving force in an open channel flow. Froude number can be defined by Equation 2.1 below. Where, Fr = (gd)2 (2.1) V = water velocity D = Hydraulic depth (cross sectional area of flow/top width) 9 = Gravity

8 The flow regime condition can be categorized according to the value of the Froude number which when, i. Fr = 1, Critical flow ii. Fr > 1, supercritical flow (fast rapid flow) iii. Fr < 1, Subcritical flow(slow/tranquil flow) 2.3 SPECIFIC ENERGY (E) The early concept of Specific Energy, E has been introduced by Bakhmeteff, a Russian émigré to the United States in his book which focused on varied flow and introduced the notion of specific energy which is an important factor for the analysis and understanding of open channel flow problems. Specific energy can be defined as in the Equation 2.2. E =y+v2/2g (2.2) Where, y = vertical distance from the bed to the water surface v velocity of flow And for rectangular channel, E=y+ 2gy2 (2.3) Where, q is the discharge per unit width of channel.

9 For a non-rectangular channel, Equation 2.2 may be rewritten to incorporate a mean channel velocity derived from the total discharge, Q, and the total cross sectional area, A: 2gA2 (2.4) Specific energy may clearly be defined as the height of the energy grade line above the channel bottom. If the specific energy is defined as the total of depth and velocity head, the possible solution of the problem for the depth depend on the variation of specific energy with depth. Figure 2.4 shows the specific energy function plotted in graphical from called the specific energy diagram. The two possible values for y are the alternate depths. One of the solutions will lie on the upper part of the graph which represented subcritical flow (typically slow and deep); the other representing supercritical flow which is fast and shallow, will fall on the lower part of the graph. Y B dy V2 Y -- 1 ' / / -- ------ ' 21.' Supercritica - Y.- D flow range - SCtWrg _ A" 45' for a channel I - C) of zero or small slope - - Figure 2.4: Specific Energy Diagram (DROP Manual, 1997)

10 2.4 REYNOLDS NUMBER The Reynolds number can be defined for several different situations where a fluid is in relative motion to a surface. These definitions generally include the fluid properties of density and viscosity, plus a velocity and a characteristic length or characteristic dimension. This dimension is a matter of convention - for example radius and diameter are equally valid to describe spheres or circles, but one is chosen by convention. For aircraft or ships, the length or width can be used. For flow in a pipe or a sphere moving in a fluid the internal diameter is generally used today. Other shapes such as rectangular pipes or non-spherical objects have an equivalent diameter defined. For fluids of variable density such as compressible gases or fluids of variable viscosity such as non-newtonian fluids, special rules apply. The velocity may also be a matter of convention in some circumstances, notably stirred vessels. Reynolds number formula is given by: Re pvl Ii (2.5) Where, P density of the fluid, V velocity of the fluid, viscosity of fluid, L length or diameter of the fluid The Kind of flow depends on value of R, i. If Re <2000 the flow is Laminar ii. iii. If Re> 4000 the flow is turbulent If 2000 <Re <4000 it is called transition flow