Department of Solid Earth Geochemistry (DSEG), Japan Agency for Marine-Earth

Similar documents
Precise Pb isotope analysis of igneous rocks using fully-automated double spike thermal ionization mass spectrometry (FA -DS- TIMS)

FRONTIER RESEARCH ON EARTH EVOLUTION, VOL. 2. Research Program for Data and Sample Analyses, Institute For Research on Earth Evolution (IFREE) 2

Uncertainty in Measurement of Isotope Ratios by Multi-Collector Mass Spectrometry

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Geochemical analysis unveils frictional melting process in a

Autenticity control, provenance testing and fraud detection using mass spectrometry

Low level Os isotopic measurements using multiple ion counting

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

High-precision in situ analysis of Pb isotopes in melt inclusions by LA-ICP-MS and application of Independent Component Analysis

Analysis of Arsenic, Selenium and Antimony in Seawater by Continuous-Flow Hydride ICP-MS with ISIS

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Nu Plasma II - Collector Configuration

Certification Report. REIMEP 18 Inter-Laboratory Comparison for the Measurement of Uranium Isotopic Ratios in Nitric Acid Solution

ICPMS Doherty Lecture 1

UNIVERSITY OF CALGARY. Measurement of the absolute isotopic composition and atomic weight

Evaluating the precision of Pb isotope measurement by mass spectrometry

Determination of Ni isotopes in nickel material from the Rossi reactor

Additional Analytical Methods. Detrital zircon samples were collected from nine fine-, medium-, and coarse-grained

Yongsheng He (1)*, YangWang (1), ChuanweiZhu (1), ShichunHuang (2) and Shuguang Li (1) Vol. 41 N p

2. QUALITY CONTROL IN MASS SPECTROMETRY

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

A new variable dispersion double-focusing plasma mass spectrometer with performance illustrated for Pb isotopes

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

Measurement of δ 44 Ca Using a 43 Ca- 42 Ca Double-spike TIMS Technique

Improvement of bulk analysis of environmental samples by using a multiple collector ICP-MS

Accurate and precise determination of lead isotope composition in selected geochemical reference materials

Lead isotope analysis: Removal of 204 Hg isobaric interference from 204 Pb using ICP-QQQ in MS/MS mode

GSA DATA REPOSITORY

Evaluation of the n( 235 U)/n( 238 U) isotope ratio measurements in a set of uranium samples by thermal ionization mass spectrometry

Geochemical Journal, Vol. 51, 2017 doi: /geochemj

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Water Rock Interaction [WRI 14] Chemical weathering of granitic rocks: experimental approach and Pb-Li isotopes tracing

Jong-Sik Ryu, Min Seok Choi, Youn-Joong Jeong and Chang-sik Cheong *

Th- 234 U model ages of some uranium standard reference materials

Preparation and Certification of IRMM-081a and IRMM-086 Spike Isotopic Reference Materials

ICP-MS. High Resolution ICP-MS.

Preparation and Certification of IRMM-075. A. Verbruggen, A. Alonso, R. Eykens, F. Kehoe, H. Kühn, S. Richter, R. Wellum, Y.

á233ñ ELEMENTAL IMPURITIES PROCEDURES

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Sodium Chloride - Analytical Standard

Accurate Analysis of Trace Mercury in Cosmetics using the Agilent 8900 ICP-QQQ

Antonio Simonetti University of Notre Dame

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

HELIX MC Plus. Static Vacuum. ARGUS VI Thermo Scientific HELIX MC Plus Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES

Isotope Dilution Mass Spectrometry

Comparing Collision/Reaction Cell Modes for the Measurement of Interfered Analytes in Complex Matrices using the Agilent 7700 Series ICP-MS

Quality Control Procedures for Graphite Furnace AAS using Avanta Software

The problems as we saw them were;

Institute for Research on Earth Evolution, Japan Agency for Marine-Earth Science and Technology, 2-15 Natsushima-cho, Yokosuka , Japan

ELEMENTAL ANALYSIS OF GLASS EXAMINATIONS (PART 1) Module 4

Sample Analysis Design PART II

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Supporting information Online HPLC-ESI-HRMS Method for the Analysis and Comparison of Different Dissolved Organic Matter Samples

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

MOF-76: From Luminescent Probe to Highly Efficient U VI Sorption Material

PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009]

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

SUPPLEMENTARY INFORMATION

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

PERSPECTIVE STABLE ISOTOPE RATIO MS

AGE DETERMINATION OF HIGHLY ENRICHED URANIUM

Speciation and δ 34 S analysis of volatile organic compounds in crude oil by GC-MC-ICP-MS using the Thermo Scientific GCI 300 Interface

Thermo Scientific Neptune XT MC-ICP-MS

Authors: C. Derrick Quarles, Jr. *, Patrick Sullivan, M. Paul Field, Hwan Kim, and Daniel R. Wiederin

TABLE DR2. Lu-Hf ISOTOPIC DATA FOR WHOLE ROCK SAMPLES AND ZIRCONS [Lu] [Hf]

Test Method: CPSC-CH-E

Finnigan TRITON Finnigan NEPTUNE. High Resolution Multicollector Mass Spectrometers

Ultra trace measurement of potassium and other elements in ultrapure water using the Agilent 8800 ICP-QQQ in cool plasma reaction cell mode

ASEAN GUIDELINES FOR VALIDATION OF ANALYTICAL PROCEDURES

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

Determination of plutonium isotopes in spent nuclear fuel using thermal ionization mass spectrometry (TI-MS) and alpha spectrometry

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

Precise Determination of Trace Elements in Geological Samples by ICP-MS Using Compromise Conditions and Fine Matrix- Matching Strategy

Application of total reflection X-ray fluorescence spectrometry for trace elemental analysis of rainwater

Fergus Keenan Shona McSheehy Julian Wills

METHOD 9252A CHLORIDE (TITRIMETRIC, MERCURIC NITRATE)

JRP SIB09 Elements GOOD PRACTICE GUIDE ON DEALING WITH INTERFERENCES IN ICP-MS FOR INVESTIGATING HIGH PURITY MATERIALS. Deliverable 1.2.

Use of ICP-MS in analysing radioisotopes. Per Roos Risø National Laboratory for Sustainable Energy, Technicial University of Denmark

Application note. Trace level analysis of sulfur, phosphorus, silicon and chlorine in NMP using the Agilent 8800 Triple Quadrupole ICP-MS

Comprehensive analysis for major, minor and trace element contents and Sr Nd Pb Hf isotope ratios in sediment reference materials, JSd-1 and MAG-1

METHOD 9035 SULFATE (COLORIMETRIC, AUTOMATED, CHLORANILATE)

PERSPECTIVE STABLE ISOTOPE RATIO MS

Major element compositions of the minerals were obtained on polished thin sections using a

(Received August 1, 2007; Accepted October 10, 2007)

High Precision Pb Isotope Techniques from the WHOI NEPTUNE PIMMS

GSA Data Repository Denyszyn, et al., 2018, A bigger tent for CAMP: Geology,

of mass spectrometry

Pharmacopeial Forum Vol. 36(1) [Jan. Feb. 2010] 1

Thermo Scientific TRITON Thermal Ionization MS. Thermo Scientific NEPTUNE Multicollector ICP-MS. High Resolution Multicollector Mass Spectrometers

Urchin-like Ni-P microstructures: A facile synthesis, properties. and application in the fast removal of heavy-metal ions

Transcription:

1 Report 2 Determination of stable isotope ratios of Ba by 130 Ba 135 Ba double-spike total 3 evaporation method using thermal ionization mass spectrometry (DS-TEV-TIMS) 4 5 Takashi Miyazaki 1*, Jun-Ichi Kimura 1, Shigeyuki Wakaki 2, Bogdan Stefanov Vaglarov 1, 6 Satoru Haraguchi 1 7 8 1 Department of Solid Earth Geochemistry (DSEG), Japan Agency for Marine-Earth 9 Science and Technology (JAMSTEC) 10 2 Kochi Institute for Core Sample Research (KOCHI), Japan Agency for Marine-Earth 11 Science and Technology (JAMSTEC) 12 13 *Corresponding author: Takashi Miyazaki 14 Department of Solid Earth Geochemistry (DSEG), Japan Agency for Marine-Earth 15 Science and Technology (JAMSTEC) 16 2-15 Natsushima-cho, Yokosuka 237-0061 Japan 17 Email address: tmiyazaki@jamstec.go.jp 18

19 Abstract (<250 words) 20 An analytical method for determining the stable isotope ratios of Ba was developed 21 by using thermal ionization mass spectrometry (TIMS) and the 130 Ba 135 Ba 22 double-spike total evaporation method (DS-TEV). We determined the isotope ratios of 23 the 130 Ba 135 Ba double spike to be 134 Ba/ 130 Ba = 0.076623, 135 Ba/ 130 Ba = 1.081975, and 24 137 Ba/ 130 Ba = 0.209356 by using the intercept values of the mass-dependent 25 fractionation lines and mixing line. 26 The measured repeatability of δ 137/134 Ba of the National Institute of Standards and 27 Technology (NIST) Standard Reference Material (SRM) 3104a was ±0.018 (2SD: 2 28 standard deviations, n = 7) based on the double-spike total evaporation method using 29 thermal ionization mass spectrometry (DS-TEV-TIMS). The repeatability is comparable 30 to or better than the best repeatability of Ba isotope ratios ever reported. 31 32 Keywords: Stable Ba isotope, double spike, total evaporation, TIMS, NIST SRM 3104a 33 34 Running title: Determination of stable Ba isotope ratios by DS-TEV-TIMS 35 36 1. Introduction

37 Ba has seven stable isotopes: 130 Ba (0.106% isotope abundance), 132 Ba (0.101%), 38 134 Ba (2.417%), 135 Ba (6.592%), 136 Ba (7.854%), 137 Ba (11.232%), and 138 Ba (71.698%; 39 de Laeter et al., 2003). Owing to their usefulness as nontraditional stable isotopes with 40 heavy atomic mass, stable isotope ratios of Ba continue to receive attention in various 41 research fields of earth science. The high sensitivity of stable Ba isotope ratios from 42 various geochemical processes such as diffusion, adsorption, dissolution, and 43 precipitation at low temperature has been advantageous in marine geochemical research 44 focusing on the oceanic Ba cycle (Lu et al., 2017, and references therein). The 45 breakthrough study of von Allmen et al. (2010) has dramatically improved the analytical 46 precision of Ba isotope ratios since 2010 (Lu et al., 2017, and references therein). 47 However, a lack of accepted reference materials has created limitations in the analysis 48 of stable Ba isotopes (van Zuilen et al., 2016; Lu et al., 2017), which has led to 49 difficulties in using absolute isotope ratios and interlaboratory data comparisons based 50 on relative isotope ratios such as theδ-notation. Von Allmen et al. (2010) and Miyazaki 51 et al. (2014) suggested the use of BaCO3 issued by International Atomic Energy Agency 52 (IAEA-CO-9) as international reference material. However, this standard is no longer 53 available. Instead, a Ba standard solution issued by the National Institute of Standard 54 and Technology (NIST), SRM 3104a, has recently been proposed as an alternative

55 reference material (van Zuilen et al., 2016). Therefore, precise determination of the Ba 56 isotope ratios of NIST SRM 3104a is required. 57 Thermal ionization mass spectrometry (TIMS) is a standard technique used for 58 high-precision analysis of stable Ba isotopes, although many laboratories use 59 multiple-collector-inductively coupled plasma-mass spectrometry (MC-ICP-MS). To 60 maximize the advantage of TIMS, the accurate correction of mass-dependent mass 61 fractionation (MDF) occurring in the mass spectrometer is required because internal 62 mass fractionation correction using a canonical stable isotope ratio, which is used in the 63 studies on mass-independent mass fractionation (MIF) especially for the isotope 64 analysis of radiogenic origin, is not applicable for stable isotope analysis. 65 The double-spike (DS) method is widely used for correction of MDF in Ba isotope 66 analyses (e.g., von Allmen et al., 2010; Miyazaki et al., 2014; van Zuilen et al., 2016). 67 To accomplish high-precision DS-TIMS, sample evaporation from the ion source 68 filament should follow the MDF law, which usually is an exponential law. However, 69 unusual mass fractionation occurs during sample evaporation, most likely owing to 70 isotopically heterogeneous sample domains on the filament (Upadhyay et al., 2008; 71 Andreasen and Sharma, 2009). The total evaporation method (TEV) is useful for 72 overcoming this problem. The influence of unusual mass fractionation can be

73 minimized by the TEV technique, where a sample on the filament completely 74 evaporates and all emitted ion beams are acquired by the collectors (e.g., Suzuki et al., 75 2004; Fukami et al., 2017, and references therein). During the actual TEV-TIMS 76 analysis, the signal acquisition of a sample is incomplete because of the background 77 noise for which an acquisition threshold is set. In practice, tiny amounts of sample 78 evaporation before and after TEV signal acquisition are not measured owing to the 79 threshold, which results in small error in determination of the isotope ratios. Therefore, 80 additional examination and refinement of MDF are necessary. 81 In this study, we thoroughly examine and report the DS method in combination with 82 the TEV method (DS-TEV) for analysis of stable Ba isotope ratios. Ba isotope ratios of 83 the NIST SRM 3104a standard using the DS-TEV-TIMS technique are also reported. 84 85 2. Experimental 86 2.1. Reagents, spike, and isotope standard materials 87 TAMAPURE -AA grade ultrapure water and TAMAPURE -AA-10 grade (<10 ppt 88 impurities) 68% HNO3 (Tama Chemical Co., Ltd., Kawasaki, Japan) were used without 89 additional purification. The TAMAPURE -AA grade ultra-pure water was used only to 90 dilute the double-spike standard. Deionized water was purified via a two-bottle Teflon

91 still from Milli-Q water (Millipore Molsheim, France). The 130 Ba-enriched spike 92 (Batch No. 230901, enrichment 35.84% ± 0.007%, carbonate) and 135 Ba-enriched spike 93 (Batch No. 142890, enrichment 93.38% ± 0.02%, carbonate) were obtained from Oak 94 Ridge National Laboratory (ORNL), USA. The 130 Ba- and 135 Ba-enriched spikes were 95 separately dissolved in 0.5 M HNO3. Subsequently, the 130 Ba and 135 Ba spike solutions 96 were mixed and diluted to approximately 1 mg/l. The Ba reference material 97 (SRM3104a, Ba standard solution (6.994 ± 0.0017 mg/g in 1% nitric acid), Lot No. 98 140909) from NIST was diluted to 0.01 mg/g using 1% HNO3. 99 100 2.2. Mass spectrometry and data reduction 101 The Ba isotope ratios were determined by using a Thermo Finnigan TRITON TI 102 thermal ionization mass spectrometer equipped with nine Faraday cup collectors at the 103 Department of Solid Earth Geochemistry (DSEG), Japan Agency for Marine-Earth 104 Science and Technology (JAMSTEC). An accelerating voltage of 10 kv was used for 105 the Ba isotope analysis. The Faraday collectors were set to simultaneously detect the 106 following isotopes: 130 Ba (Low 3), 132 Ba (Low 2), 134 Ba (Low 1), 135 Ba (Center), 136 Ba 107 (High 1), 137 Ba (High 2), 139 La (High 3), and 140 Ce (High 4). All Faraday collectors were 108 connected to the amplifiers by using a 10 11 Ω resistor. The stability of this acquisition

109 system was tested by Miyazaki et al. (2009). The relative efficiencies of the Faraday 110 collectors known, as the cups factors of this TIMS (Miyazaki et al., 2016), were not 111 used in this study because their effect was negligible during the analytical period. 112 Additional cup factor correction should be necessary when the cups are deteriorated 113 (e.g., Miyazaki et al., 2016). 114 A double Re filament was used as the ion source. Prior to sample loading, both the 115 evaporation and ionization filaments were degassed in a vacuum for 45 min at 4.6 A. 116 Approximately 100 ng Ba was dissolved in 2 μl of 2% HNO3, and the solution was 117 loaded onto the center of the Re evaporation filament for the standard, double-spike, 118 and mixed samples. A current of 0.6 A was continuously applied during the loading until 119 the solution evaporated. 120 Using the TRITON TI, we combined the method files in a sequence file to measure 121 several samples in one sequential run, and we modified the measurement file protocols 122 for Pb isotopes described by Miyazaki et al. (2009). Table 1 shows the four method files 123 included in one sequence file: (1) gain calibration, (2) baseline measurement, (3) 124 filament heating and sample measurement, and (4) blank measurement for baseline drift 125 correction. According to this method, the gain calibration and baseline measurements 126 were conducted prior to heating the filaments. The baseline was measured for 15 min.

127 To monitor the baseline drift during data acquisition, one blank sample measurement 128 was performed at the end of the analytical sequence by measuring the signal intensity of 129 each Faraday collector without heating the ion source filaments. The raw intensity data 130 were used for necessary offline corrections (Miyazaki et al., 2009). 131 The ionization and evaporation filaments were automatically heated by the filament 132 heating program in the sample measurement method file (Method file 3-1 in Table 1). 133 Using this program, the ionization filament was first heated to 2.8 A at a rate of 0.56 134 A/min. Then, the evaporation filament was heated to 0.5 A at a rate of 0.1 A/min. After 135 the ionization and evaporation filaments reached 2.8 A and 0.5 A, the current of the 136 evaporation filament was increased at a rate of 0.05 A/min until the beam intensity of 137 the pilot mass reached 5 mv. The highest abundance isotope peak was chosen for the 138 pilot monitor mass to avoid excess heating during lens tuning. We avoided 138 Ba owing 139 to its extremely high abundance. Instead, 137 Ba was used for unspiked runs and 135 Ba 140 was used for spiked and mixture runs because 135 Ba had the highest abundance in the 141 latter samples. The ion lenses were then optimized to focus 1 min later. The electric 142 current of the evaporation filament was increased again at a rate of 0.05 A/min until the 143 beam intensity of the pilot mass reached 10 mv. Peak centering was performed 1 min 144 later, and the data acquisition was started. During data acquisition, the electric current of

145 the evaporation filament was increased at ~5 ma/cycle unless the pilot beam intensity 146 exceeded 4200 mv. The integration time was 1.05 s/cycle. The data acquisition was 147 terminated when the pilot beam intensity decayed below 5 mv, which was set as the 148 noise threshold. The raw beam intensity data of all cycles were summed for each 149 isotope; these summed intensities were used to calculate the isotope ratios. 150 In this study, we assumed that the MDF followed an exponential law. The 151 three-dimensional data reduction procedure of Siebert et al. (2001) was applied. The 152 134 Ba/ 130 Ba, 135 Ba/ 130 Ba, and 137 Ba/ 130 Ba ratios determined by using the summed 153 intensity data were used for regression calculations in an Excel spreadsheet to obtain the 154 corrected 134 Ba/ 130 Ba, 135 Ba/ 130 Ba, and 137 Ba/ 130 Ba ratios by the DS method. For the 155 regression calculations, the measured isotope ratios of the unspiked sample (standard in 156 this study) and the DS-spiked sample were used. The 137 Ba/ 134 Ba ratio was calculated to 157 determine the δ 137/134 Ba value based on the following equation: δ 137/134 Ba = 158 [( 137 Ba/ 134 Basample)/( 137 Ba/ 134 Bastandard)-1] 1000. The strong 138 Ba signal (71.7% 159 isotopic abundance) was not measured in this study to avoid any damage of the 160 designated Faraday cup, although δ 138/134 Ba has been used in many studies. The 161 δ 138/134 Ba value can be calculated from the δ 137/134 Ba value when MIF is not present in 162 the analyzed samples.

163 The tailing of the strongest 138 Ba signal (no Faraday cup assignment) was not 164 detected by the neighboring higher mass side Faraday cup (High 3: 139 La). The mass 165 peaks show totally symmetry shape by the TIMS, tailing from 138 Ba on the low mass 166 side Faraday (High 2: 137 Ba) should also be negligible. 167 168 3. DS calibration 169 3.1. DS calibration methods in previous studies 170 For high-precision DS isotope analysis with minimized propagated errors, optimized 171 conditions such as the choice of isotopes and mixing ratio of two spikes were simulated 172 by the model proposed by Rudge et al. (2009). We applied 130 Ba and 135 Ba as the DS 173 spikes and prepared a 130 Ba 135 Ba DS solution based on the simulation. The isotope 174 ratios used for the 130 Ba 135 Ba DS were calculated from the weight and atomic 175 abundance data supplied by the ORNL, where 134 Ba/ 130 Ba = 0.076432, 135 Ba/ 130 Ba = 176 1.040925, and 137 Ba/ 130 Ba = 0.208963 (Table 2). Notably, small but inevitable errors 177 that occur during weighing and diluting as well as additional errors are inherited from 178 ORNL reference atomic abundance values, all of which affect the isotope ratios of the 179 130 Ba 135 Ba DS solution. Therefore, calibration is required to determine accurate isotope 180 ratios of the DS solution. In the case of stable Ba isotopes, such calibration is difficult

181 owing to the lack of a standard material with well-characterized isotope ratios 182 (Miyazaki et al., 2014). 183 Several calibration methods can be used to overcome the aforementioned problem. 184 For example, von Allmen et al. (2010) and van Zuilen et al. (2016) calibrated their 185 130 Ba 135 Ba DS solution by applying the fractionation factor of the 142 Nd/ 144 Nd ratio of 186 an Nd standard to their analytical protocols using MC-ICP-MS. This external mass 187 fractionation calibration is not applicable to TIMS because the evaporation and 188 ionization conditions for Ba and Nd differ such that emission of stable ion beams under 189 a given filament temperature is difficult. Even with MC-ICP-MS, the mass bias 190 determined by using the 142 Nd/ 144 Nd ratio is different from that based on the 137 Ba/ 135 Ba 191 ratio because of the space charge effect at the ion sampling interface (Hirata, 1996) or 192 non-mass-dependent fractionation of Nd isotopes (Newman, 2012), as pointed out by 193 Miyazaki et al. (2014). 194 Therefore, Miyazaki et al. (2014) developed a new DS calibration method that does 195 not depend on the use of standard material with well-known isotope ratios. They 196 revealed that a precise Ba isotope ratio measurement can be achieved only by using the 197 correct DS isotope ratios when unknown samples with different spike/sample ratios are 198 measured with the standard bracketing method and MC-ICP-MS. They conducted

199 several measurements using IAEA-CO-9 with different spike/sample ratios (0.11 0.33) 200 as the samples and IAEA-CO-9 with a fixed spike/standard ratio (0.175) as the 201 bracketing standard, and they iteratively determined the correct 130 Ba 135 Ba DS isotope 202 ratios to achieve an invariant value for all measured δ 137/134 Ba values. The initial 203 assumption of their calibration method is that the true DS isotope ratio plots on the 204 mixing line of the two spikes. 205 Van Zuilen et al. (2016) also reported a DS calibration method using TIMS in which 206 they calibrated 132 Ba 136 Ba DS, also without using material with known isotope ratios. 207 In contrast to the mixing line method by Miyazaki et al. (2014), they measured the pure 208 DS solution and artificially altered the DS Ba isotope ratios along the MDF line using 209 an exponential law to determine the average values of δ 137/134 Ba and δ 138/134 Ba of the 210 target NIST SRM 3104a becoming 0. 211 In this study, we adopted both the mixing line method of Miyazaki et al. (2014) and 212 the MDF line method of van Zuilen et al. (2016), and we used TEV-TIMS to calibrate 213 the 130 Ba 135 Ba DS solution. 214 215 3.2. DS calibration methods by TEV-TIMS 216 The isotope ratio measurements in TEV-TIMS is almost free from the influence of

217 MDF owing to the acquisition of all ions emitted from the sample on the filament (e.g., 218 Suzuki et al., 2004; Fukami et al., 2017). Therefore, TEV-TIMS is suitable for precise 219 determination of isotope ratios of any DS solution. However, the actual measurements 220 of the 130 Ba 135 Ba DS solution by TEV-TIMS showed MDF (Table 2, Fig. 1), whereas 221 significant MIF was not observed. As shown in Fig. 1, all data points were on the MDF 222 line. The origin of MDF is unknown and may be attributed to MDF occurrence during 223 sample loading or filament heating. Alternatively, it may have been caused by the effect 224 of the noise threshold cutoff or the collision of ions with remnant gases in the flight tube. 225 Regardless of its source, however, additional MDF correction is necessary. 226 If the measured isotope ratios of the DS solution are affected by MDF alone, the 227 MDF line calculated from the datapoints should cross the mixing line between the two 228 spikes, and the coordinates of the intercept should show the correct isotope ratios of the 229 DS solution (Fig. 1). However, the calculated MDF did not cross at the exact 230 coordinates in three two-dimensional isotope spaces (Fig. 1). This result occurred 231 because of the correlation errors in MDF regression lines and the mixing line owing to a 232 common denominator with three numerator isotopes such as 137 Ba/ 130 Ba 135 Ba/ 130 Ba, 233 134 Ba/ 130 Ba 135 Ba/ 130 Ba, or 137 Ba/ 130 Ba 134 Ba/ 130 Ba (Fig. 1). Instead of determining 234 each intercept coordinates by linear regressions using all data, we iteratively determined

235 the best fit solutions for each measured isotope MDF data. We applied an Excel 236 spreadsheet and calculated 12 intercept values for 134 Ba/ 130 Ba, 135 Ba/ 130 Ba, and 237 137 Ba/ 130 Ba, which were averaged to obtain the isotope ratios of the spike solution. 238 Using this method, we calibrated the 130 Ba 135 Ba DS solution. The calibrated isotope 239 ratios were 134 Ba/ 130 Ba = 0.076623 ± 0.000002, 135 Ba/ 130 Ba = 1.081975 ± 0.000102, and 240 137 Ba/ 130 Ba = 0.209356 ± 0.000001 (2SD: two-standard deviation, n = 12) (Table 2, Fig. 241 1). 242 The errors of the atomic abundances provided by the ORNL for the two spikes were 243 not considered. We used a fixed line as mixing line; therefore, it was necessary to 244 estimate the degree to which the calibrated isotope ratios were influenced by the initial 245 errors of the atomic abundances listed in Table 2. We simply estimated the effects of the 246 errors by applying the maximum and minimum atomic abundances of the error ranges. 247 The maximum effect is shown by 135 Ba/ 130 Ba = 1.081233 1.082718, corresponding to 248 an error of ±686 ppm. According to the simulation by Miyazaki et al. (2014), the atomic 249 abundance error of ±686 ppm ( 135 Ba/ 130 Ba ratio of spike) affects the δ 137/134 Ba values 250 within ±0.01 for measurements using a spike/sample ratio of 0.03 0.28 in sample run 251 if the spike/standard ratio of the bracketing mixture is fixed to 0.178. The resultant error 252 is smaller than the achievable repeatability and laboratory biases of ~0.02 for stable

253 Ba isotope analyses (Miyazaki et al., 2014). Therefore, we ignored the atomic 254 abundance errors of the two ORNL spikes in this study. 255 256 4. Stable Ba isotope analysis of NIST SRM 3104a 257 To evaluate the TEV-DS-TIMS method for determining the stable Ba isotope ratios, 258 we analyzed NIST standard SRM 3104a. The typical profiles of the 135 Ba beam signal 259 intensity and the electric current of the evaporation filament are shown in Fig. 2a. The 260 beam intensity increased rapidly and was maintained at the preset intensity of 4200 mv. 261 The increment of the filament current was automatically adjusted to maintain the preset 262 beam intensity. Subsequently, the intensity rapidly decreased and rose again, leading to 263 two peaks showing aftergrowth. The beam intensity finally returned to zero, indicating 264 full consumption of the loaded sample. Aftergrowth was observed in almost all 265 measurements conducted in this study. The first drop in beam intensity prior to 266 aftergrowth commonly occurred when the electric current of the evaporation filament 267 was 1.0 1.5 A. Although the cause of this reproducible profile is unclear, it might not 268 relate to differences in chemical form, such as the nitric or hydrochloric form, because 269 all Ba standard and spike solutions were diluted by nitric acid only. For further 270 evaluation, the signal profile was divided into four segments of A, B, C, and D (Fig. 2)

271 at 0.155 V intensity. It should be noted that this value corresponds with the lowest 272 intensity between the first drop and the aftergrowth (Fig. 2). 273 Fig. 3 shows the plots of the 137 Ba/ 130 Ba and 135 Ba/ 130 Ba ratios from all 1060 cycles 274 of 1.05 s acquisition in one measurement; Fig. 2 shows the same sample. Although the 275 data from the first A (heavier isotope ratio) and last D (lighter isotope ratio) segments 276 were scattered because of the low beam intensity, all of the other data including the B 277 and C segments were plotted along the MDF line. Therefore, the scatter data in the A 278 and D segments can be omitted by applying the threshold. It is obvious that all Ba ions 279 emitted from the evaporation filament were derived from the same sample throughout 280 the run. The effect of Ba impurity emitted from the degassed Re filaments was 281 negligible because only 12000 cps of 138 Ba, an equivalent of <0.2 mv in the Faraday 282 collector, was detected at filament currents of 4.2 A for ionization and ~2.5 A for 283 evaporation. 284 The range of fractionation observed in segment C was wide and overlapped the 285 range of the B segment. Lower isotope ratios relative to those in segment B were found 286 in segment C, showing so-called reverse fractionation (Fig. 2b, Fig. 3) caused by ion 287 mixing fed from strongly fractionated and weakly fractionated reservoirs on the same 288 filament (Upadhyay et al., 2008; Andreasen et al., 2009). Essentially, the data from the

289 reverse fractionation region might not be shown on the MDF line but could appear on 290 the mixing line between the two less- and more-fractionated reservoirs, although the 291 data from the reverse fractionation region looks on the same MDF line (Fig. 3). 292 Applying the total evaporation method can eliminate the non-mdf effect from the 293 reverse fractionation if persistent. 294 Table 3 and Fig. 4 show the results of the measurements of the NIST SRM 3104a 295 standard solution by TEV-TIMS with and without DS correction. Following simulations 296 by Rudge et al. (2009) and Miyazaki et al. (2014), a spike/standard ratio of 0.175 was 297 applied to prepare the mixed solution to minimize errors. The average isotope ratios of 298 the unspiked runs ( 134 Ba/ 130 Ba = 22.8802, 135 Ba/ 130 Ba = 62.4301, and 137 Ba/ 130 Ba = 299 106.4235) were used as the sample ratios of an unspiked run to calculate the corrected 300 isotope ratios of each spiked run. If the Ba isotope ratios of sample are affected only by 301 MDF, correction is possible by using a spiked run only (mixture run only). In this case, 302 an optimal MDF factor should have been determined. We used Ba isotope ratios 303 determined by an unspiked NIST SRM 3104a to obtain the optimal MDF factor. As 304 expected, the isotope ratios from DS correction showed lower isotope ratios (Fig. 4) 305 with smaller deviation than those from measurements without DS correction. If we 306 calculate the errors of the δ-notation using the average 137 Ba/ 134 Ba ratios from DS

307 correction as reference values, the deviations of the δ 137/134 Ba values are ±0.018 (2SD, 308 n = 7) for DS-corrected and ±0.165 (2SD, n = 8) for uncorrected results, where 2SD 309 contains error ranges of ±0.001 and ±0.012, respectively, owing to the small value 310 of n. Clearly, the repeatability of δ 137 / 134 Ba is far better using DS correction and is 311 comparable to or even better than that of the best values reported in previous studies. 312 For example, Miyazaki et al. (2014) reported ±0.032 (2SD, n = 42) for δ 137 / 134 Ba of 313 the Fluka (Aldrich) standard solution, and Nan et al. (2015) reported ±0.047 (2SD, 314 n = 36) for δ 137 / 134 Ba of the NIST SRM 3104a standard solution. 315 The isotope ratios for NIST SRM 3104a (Lot No. 070222) are only available from 316 van Zuilen et al. (2016) (Table 3). Their isotope ratios differ from ours beyond the 317 variation observed in natural samples (e.g., seawater; Cao et al., 2016). A comparison 318 based on our NIST SRM 3104a ratio as reference revealed that their δ 137 / 134 Ba value is 319 1.723. Such large variation was observed only in the experimental study by van 320 Zuilen et al. (2016), who reported a maximum difference of 2.15 for δ 137 / 134 Ba owing 321 to diffusion. This clearly indicates the importance of an international, isotopically 322 homogeneous Ba reference material for the δ-notation. The NIST SRM 3104a standard 323 has been proposed as δ-zero reference material for stable Ba isotope analysis (van 324 Zuilen et al., 2016). However, the same NIST SRM 3104a standard (Lot No. 140909)

325 used in this study was newly released in February 2016. Its certified Ba concentration 326 differs from that of the previous lot, with 10.014 ± 0.036 mg/g for Lot No. 070222 (van 327 Zuilen et al., 2016) versus 6.994 ± 0.0017 mg/g for Lot No. 140909 used in this study. 328 At this stage, it is not clear that the different δ 137 / 134 Ba values reported from van Zuilen 329 et al. (2016) were caused by different analytical method because the standard from a 330 different production lot could have different Ba isotope composition. In fact, NIST 331 SRM 3104a is not the standard for Ba isotope ratios but for Ba concentration, as van 332 Zuilen et al. (2016) suggested the necessity of tests for different lots of NIST SRM 333 3104a. 334 335 5. Conclusion 336 We developed a precise analytical method for determining stable Ba isotope ratios 337 using DS-TEV-TIMS. In this method, the DS was used for MDF correction in the TIMS 338 instrument. The DS solution created from ORNL spikes was calibrated without using a 339 Ba standard by instead determining the relationship between the MDF lines of the DS 340 solution and the mixing lines between the two Ba spikes. The repeatability of the 341 δ 137/134 Ba ratios based on repeated analyses of a standard solution was approximately 342 twice that reported in previous studies.

343 344 Acknowledgement 345 The authors thank W. Zhang, H. Higuchi, and M. Kanazawa of JAMSTEC for their 346 support with the laboratory work and Q. Chang for useful discussion. In addition, the 347 authors thank two anonymous reviewers for their constructive comments and H. 348 Kumagai for his constructive comments and editorial handling. T.M. was funded by a 349 JSPS KAKENHI grant JP15K05357. 350 351 References 352 Andreasen, R., and M. Sharma (2009), Fractionation and mixing in a thermal ionization 353 mass spectrometer source: Implications and limitations for high-precision Nd 354 isotope analyses, Int. J. Mass Spectrom., 285, 49-57, 355 doi:10.1016/j.ijms.2009.04.004. 356 Cao, Z., C. Siebert, E.C. Hathorne, M. Dai, and M. Frank (2016), Constraining the 357 oceanic barium cycle with stable barium isotopes, Earth Planet. Sci. Lett., 434, 358 1-9, doi:/10.1016/j.epsl.2015.11.017. 359 de Laeter, J.R., J.K. Böhlke, P. De Bièvre, H. Hidaka, H.S. Peiser, K.J.R. Rosman, and 360 P.D.P. Taylor (2003), Atomic weights of the elements. Review 2000 (IUPAC

361 Technical Report), Pure Appl. Chem., 75, 683-800, doi: 362 10.1351/pac200375060683. 363 Fukami, Y., M. Tobita, T. Yokoyama, T. Usui, and R. Moriwaki (2017), Precise isotope 364 analysis of sub-nanogram lead by total evaporation thermal ionization mass 365 spectrometry (TE-TIMS) coupled with a 204 Pb- 207 Pb double spike method, J. 366 Anal. At. Spectrom., 32, 848-857, doi:10.1039/c6ja00455e. 367 Hirata, T. (1996), Lead isotope analyses of NIST Standard Reference Materials using 368 multiple collector inductively coupled plasma mass spectrometry coupled with 369 a modified external correction method for mass discrimination effect, Analyst, 370 121, 1407-1411, doi:10.1039/an9962101407. 371 Lu, D., T. Zhang, X. Yang, P. Su, Q. Liu, and G. Jiang (2017), Recent advances in the 372 analysis of non-traditional stable isotopes by multi-collector inductively 373 coupled plasma mass spectrometry, J. Anal. At. Spectrom., 32, 1848-1861, 374 doi:10.1039/c7ja00260b. 375 Miyazaki, T., N. Kanazawa, T. Takahashi, Y. Hirahara, B.S. Vaglarov, Q. Chang, J.-I. 376 Kimura, and Y. Tatsumi (2009), Precise Pb isotope analysis of igneous rocks 377 using fully-automated double spike thermal ionization mass spectrometry (FA 378 -DS- TIMS), JAMSTEC Report of Research and Development, Special Issue,

379 73-80, doi:10.5918/jamstecr.2009.73 380 Miyazaki, T., J.-I. Kimura, and Q. Chang (2014), Analysis of stable isotope ratios of Ba 381 by double-spike standard-sample bracketing using multiple-collector 382 inductively coupled plasma mass spectrometry, J. Anal. At. Spectrom., 29, 383 483-490, doi:10.1039/c3ja50311a. 384 Miyazaki, T., B.S. Vaglarov, and J.-I. Kimura (2016), Determination of relative Faraday 385 cup efficiency factor using exponential law mass fractionation model for 386 multiple collector thermal ionization mass spectrometry, Geochem. J., 50, 387 445-447, doi:10.2343/geochemj.2.0439. 388 Nan, X., F. Wu, Z. Zhang, Z. Hou, F. Huang, and H. Yu (2015), High-precision barium 389 isotope measurements by MC-ICP-MS, J. Anal. At. Spectrom., 30, 2307-2315, 390 doi:10.1039/c5ja00166h. 391 Newman, K. (2012), Effects of the sampling interface in MC-ICP-MS: Relative 392 elemental sensitivities and non-linear mass dependent fractionation of Nd 393 isotopes, J. Anal. At. Spectrom., 27, 63-70, doi:10.1039/c1ja10222b. 394 Rudge, J.F., B.C. Reynolds, and B. Bourdon (2009), The double spike toolbox, Chem. 395 Geol., 265, 420-431, doi:10.1016/j.chemgeo.2009.05.010. 396 Siebert, C., T.F. Nägler, and J.D. Kramers (2001), Determination of molybdenum

397 isotope fractionation by double-spike multicollector inductively coupled plasma 398 mass spectrometry, Geochem., Geophys., Geosyst., 2, 2000GC00124, 399 doi:10.1029/2000gc000124. 400 Suzuki, K., Y. Miyata, and N. Kanazawa (2004), Precise Re isotope ratio measurements 401 by negative thermal ionization mass spectrometry (NTI-MS) using total 402 evaporation technique, Int. J. Mass Spectrom., 235, 97-101, doi: 403 10.1016/j.ijms.2004.04.006. 404 Upadhyay, D., E.E. Scherer, and K. Mezger (2008), Fractionation and mixing of Nd 405 isotopes during thermal ionization mass spectrometry: implications for high 406 precision 142 Nd/ 144 Nd analyses, J. Anal. At. Spectrom., 23, 561-568, 407 doi:10.1039/b715585a. 408 van Zuilen, K., T.F. Nägler, and T.D. Bullen (2016), Barium Isotope Compositions of 409 Geological Reference Materials, Geostand. Geoanal. Res., 40, 543-558, 410 doi:10.1111/ggr.12122. 411 von Allmen, K., M.E. Böttcher, E. Samankassou, and T.F. Nägler (2010), Barium 412 isotope fractionation in the global barium cycle: First evidence from barium 413 minerals and precipitation experiments, Chem. Geol., 277, 70-77, 414 doi:10.1016/j.chemgeo.2010.07.011.

415 416 Captions 417 418 Fig. 1. Relationship between the measured and corrected isotope ratios of spikes in the 419 three isotope-ratio space ( 134 Ba/ 130 Ba 135 Ba/ 130 Ba 137 Ba/ 130 Ba) shown by three 420 projected planes. The open black (red) circles represent the measured (corrected) 421 spike data listed in Table 2. The black line shows the MDF line calculated from 422 the average measured data. The red line represents the mixing line drawn 423 between the 130 Ba- and 135 Ba-enriched spikes. (a) 135 Ba/ 130 Ba 137 Ba/ 130 Ba plot; 424 (b) 135 Ba/ 130 Ba 134 Ba/ 130 Ba plot; (c) 134 Ba/ 130 Ba 137 Ba/ 130 Ba plot. 425 426 Fig. 2. (a) Intensity profiles of the 135 Ba beam signal intensity and electric current 427 loaded onto the evaporation filament for measurement of the spiked solution. A 428 total of 100 ng of Ba (NIST SRM 3104a + 130 Ba 135 Ba double spike) was loaded 429 onto the evaporation filament. The electric current of the ionization filament was 430 fixed at 2.8 A. The profile is divided into four segments of A, B, C, and D at 431 intensity 0.155 V; this value is the lowest intensity between the first drop and the 432 aftergrowth. (b) 137 Ba/ 130 Ba ratios of 1060 cycles of individual 1.05 s

433 acquisitions in one measurement run. 434 435 Fig. 3. 135 Ba/ 130 Ba 137 Ba/ 130 Ba plots of 1060 cycles of individual 1.05 s acquisitions in 436 one measurement run. The cycles accumulated in the four divided segments in 437 Fig. 2 are distinguished by different colors. The measured sample contained 100 438 ng of Ba (NIST SRM 3104a + 130 Ba 135 Ba double spike); the same sample was 439 used in Fig. 2. The black filled square and the black line represent the calculated 440 isotope ratios and the MDF line from the summed values of all cycle data, 441 respectively. 442 443 Fig. 4. Comparisons of the data from NIST SRM 3104a determined with and without 444 using double-spike corrections based on the 130 Ba 135 Ba double spike. The black 445 line shows the MDF line calculated from the average values of the measured 446 data without DS. Seven red points (corrected by DS) overlap owing to small 447 isotopic variation. (a) 135 Ba/ 130 Ba 134 Ba/ 130 Ba plot. (b) 135 Ba/ 130 Ba 137 Ba/ 130 Ba 448 plot. 449 450 Table 1. Combination of the method files for fully automated DS-TEV-TIMS

451 measurement for one sample on the filament, modified from Miyazaki et al. 452 (2009). 453 454 Table 2. Double-spike data used in this study. 455 456 Table 3. Result of Ba isotope analysis for NIST SRM 3104a (Lot No. 140909).

137 Ba/ 130 Ba 0.214 0.213 0.212 0.211 0.210 Measured Corrected Mixing line MDF line a. 0.209 0.208 1.07 1.08 1.09 1.10 1.11 135 Ba/ 130 Ba 0.0776 b. 134 Ba/ 130 Ba 0.0772 0.0768 0.0764 1.07 1.08 1.09 1.10 1.11 135 Ba/ 130 Ba 0.214 0.213 c. 137 Ba/ 130 Ba 0.212 0.211 0.210 0.209 0.208 0.0764 0.0768 0.0772 0.0776 134 Ba/ 130 Ba

Fig. 2 Intensity (V) 5 4 3 2 a. Beam intensity Filament current 1 0.155 (V) A B C D 0 Total 1060 cycles (1.05 s per cycle) 2500 2000 1500 1000 500 0 Evaporation filament current (ma) 2.9 b. 2.8 137 Ba/ 130 Ba 2.7 C D B 2.6 2.5 A Total 1060 cycles (1.05 s per cycle)

Fig. 3 2.9 2.8 Summed (All cycles) MDF line 137 Ba/ 130 Ba 2.7 2.6 Measured (Cycle) 〇 A in Fig. 2 〇 B in Fig. 2 〇 C in Fig. 2 〇 D in Fig. 2 2.5 2.4 2.5 2.6 2.7 135 Ba/ 130 Ba

Fig. 4 22.90 a. 134 Ba/ 130 Ba 22.85 22.80 Measured without DS Corrected by DS MDF line 22.75 62.0 62.1 62.2 62.3 62.4 62.5 135 Ba/ 130 Ba 106.6 106.4 b. 137 Ba/ 130 Ba 106.2 106.0 105.8 105.6 105.4 62.0 62.1 62.2 62.3 62.4 62.5 135 Ba/ 130 Ba

Table 1. Combination of the method files for fully automated DS-TEV-TIMS measurement for one sample on the filament, modified from Miyazaki et al. (2009) Method File Operation Acquired data Time 1 Gain calibration Gain data (stored in operating computer) 15 min 2 Baseline measurement Baseline data (stored in operating computer) 15 min 3-1 Filament heating (Until pilot beam reach 10mV), Focusing, and peak centering 15 min 3-2 Sample measurement by TEV Raw intensity data of sample (used for off-line calculation) Max 35 min 4 Blank measurement for baseline drift correction Raw intensity data without ion beam (used for off-line calculation) 15 min

Table 2. Double-spike data used in this study. Data supplied by ORNL 130 Ba Spike 135 Ba Spike Recalculated as 100% Mixing ratio (0.746) TE-TIMS Mixing line method 130 Ba Spike 135 Ba Spike Estimated DS Measured DS Corrected DS 130 Ba (%) 35.84 ± 0.007 <0.01 35.84 0.01 26.75 132 Ba (%) 0.41 ± 0.001 0.06 ± 0.005 0.41 0.06 0.32 134 Ba (%) 2.58 ± 0.001 0.47 ± 0.005 2.58 0.47 2.04 135 Ba (%) 5.55 ± 0.011 93.38 ± 0.02 5.55 93.38 27.84 136 Ba (%) 5.56 ± 0.001 1.64 ± 0.01 5.56 1.64 4.56 137 Ba (%) 7.19 ± 0.001 0.89 ± 0.01 7.19 0.89 5.59 138 Ba (%) 42.88 ± 0.002 3.56 ± 0.02 42.88 3.56 32.90 Run 1 0.077115 0.076621 Run 2 0.077027 0.076624 Run 3 0.077025 0.076624 Run 4 0.076977 0.076624 Run 5 0.077043 0.076622 Run 6 0.077278 0.076623 Run 7 0.077135 0.076623 Run 8 0.077028 0.076624 Run 9 0.077203 0.076623 Run 10 0.077009 0.076624 Run 11 0.077011 0.076622 Run 12 0.077051 0.076624 134 Ba/ 130 Ba 0.072017 46.60 0.076432 Average 0.077075 0.076623 2SD (n = 12 0.000180 0.000002 Run 1 1.091073 1.082089 Run 2 1.089266 1.081960 Run 3 1.089238 1.081951 Run 4 1.088430 1.081989 Run 5 1.089636 1.081965 Run 6 1.093857 1.082065 Run 7 1.091180 1.081917 Run 8 1.089278 1.081960 Run 9 1.092384 1.081931 Run 10 1.088962 1.081962 Run 11 1.089051 1.081955 Run 12 1.089699 1.081954 135 Ba/ 130 Ba 0.154776 9338 1.040925 Average 1.090171 1.081975 2SD (n = 12 0.003250 0.000102 Run 1 0.211780 0.209357 Run 2 0.211325 0.209355 Run 3 0.211320 0.209355 Run 4 0.211092 0.209356 Run 5 0.211424 0.209356 Run 6 0.212537 0.209357 Run 7 0.211853 0.209355 Run 8 0.211328 0.209355 Run 9 0.212174 0.209355 Run 10 0.211243 0.209355 Run 11 0.211269 0.209356 Run 12 0.211443 0.209355 137 Ba/ 130 Ba 0.200536 89.00 0.208963 Average 0.211566 0.209356 2SD (n = 12 0.000867 0.000001 DS: 130 Ba- 135 Ba double spike, SD: standard deviation.

Table 3. Result of Ba isotope analysis for NIST SRM 3104a (Lot No. 140909). Run # 134 Ba/ 130 Ba 135 Ba/ 130 Ba 137 Ba/ 130 Ba 137 Ba/ 134 Ba δ 137/134 Ba a a. Measured ratios of NIST SRM 3104a without double-spike 1 22.8751 62.4146 106.3892 4.65088 3.328 2 22.8818 62.4331 106.4245 4.65105 3.363 3 22.8794 62.4274 106.4170 4.65121 3.398 4 22.8765 62.4227 106.4224 4.65204 3.577 5 22.8841 62.4413 106.4454 4.65149 3.459 6 22.8813 62.4351 106.4372 4.65172 3.508 7 22.8828 62.4367 106.4320 4.65118 3.392 8 22.8805 62.4300 106.4206 4.65116 3.387 Average 22.8802 62.4301 106.4235 4.65134 3.426 2SD (n=8) 0.0062 0.0170 0.0335 0.00076 0.165 b. Measured ratios of mixture (NIST SRM 3104a + 130 Ba- 135 Ba double spike) 1 0.589315 2.467152 2.597872 2 0.589242 2.466804 2.597372 3 0.589167 2.466396 2.596771 4 0.589102 2.466031 2.596217 5 0.589286 2.466970 2.597596 6 0.589167 2.466384 2.596742 7 0.589137 2.466236 2.596551 Average 0.589202 2.466567 2.597017 2SD (n=7) 0.000160 0.000825 0.001207 c. Corrected ratios of NIST SRM 3104a calculated from b 1 22.7684 62.0503 105.5248 4.63471-0.001 2 22.7687 62.0514 105.5274 4.63476 0.010 3 22.7686 62.0509 105.5262 4.63473 0.005 4 22.7681 62.0493 105.5225 4.63467-0.010 5 22.7681 62.0492 105.5222 4.63466-0.011 6 22.7683 62.0500 105.5241 4.63470-0.004 7 22.7688 62.0517 105.5280 4.63477 0.012 Average 22.7684 62.0504 105.5250 4.63471 0.000 2SD (n=7) 0.0006 0.0019 0.0046 0.00008 0.018 d. NIST SRM 3104a (Lot No. 070222) in van Zuilen et al. (2016) 22.7998 62.1762 105.8527 4.64270 1.723 a The average 137 Ba/ 134 Ba ratio of corrected ratio of NIST SRM 3104a (4.63471) is used as standard ratio.