SPECIFICATION SHEET :FH6-DUAL-3000L This Is An Original Product From Fulham Co., Inc ELECTRICAL DATA

Similar documents
SPECIFICATION SHEET : FHS2-UNV-36L

SPECIFICATION SHEET : FHS2-UNV-36L

A new set of standards

Emergency lighting units EM Inverter

F48T10VHO, F60T10VHO, F72T10VHO, F96T12HO (1 LAMP ONLY) ELECTRICAL DATA (120V APPLICATION)

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

WE RE HERE TO HELP: 1 (844) LIGHTCLOUD

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

HONOURTEK Delux Array Series HRA0407 Preliminary

CLUSTERLITE CONTENTS MEGAMAN

9W B15/B22/E14/E27 Compact Fluorescent Lamp

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

Economic and Social Council

Kingspan Smart-Lite Kite Luminaire

SHP-T Basic Plus. Sa Shp-T 150w Basic Plus E40 PRODUCT OVERVIEW DATA TABLE. Optical data. Range Features. Colour temperature (K) 2000 CRI (Ra) 20

HONOURTEK Delux Array Series HRA0303 Preliminary

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL

University of Moratuwa, Sri Lanka. EE3231: Design of Electrical Installation

Technical Notes. Introduction. PCB (printed circuit board) Design. Issue 1 January 2010

Device Specifications

Installation guide 862 MIT / MIR

Product Description. Table of contents. Relative Flux vs. Junction Temperature CLD-DS46 Rev 0. Product family data sheet

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

TECHNICAL INFORMATION

5SJ4...-.HG Circuit Breakers to IEC and UL 489

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

QTi DALI-T/E 2X18 42/ DIM

Capacitor Discharge called CD welding

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)

LED modules LED linear / area

Engineering Specification

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Common Lightcloud Wiring Applications. Wiring Diagrams. Overview Controller Dimmer Gateway Integrator Sensor Touch. Lightcloud

S R O T C U D IN & MYRRA

Compact Orifice FlowMeter

MASTER TL5 Lamps. The Safety and. fit. TrustSight LED Emergency drivers. A full range of MASTER TL5 Lamps

TEST REPORT. Page 1 of 11

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE STARK-CLE EM STARK-CLE EM-SO Ø315

KTC LED.PowerSpot 5W Dimmable SMD LED

POINTS OF CAUTION BEFORE USE...

KTC LED.PowerSpot 4W SMD LED

Worksheet for Sizing Engine Cranking Batteries X/H - Type FNC Batteries. Information Required to Size Batteries for Engine Cranking:

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

für for T5-Lampen fluorescent in Multi-Lamp-Technologie

S P E C I F I C A T I O N S

DATA SHEET POSITIVE TEMPERATURE COEFFICIENT AC/DC POWER SUPPLY SMD0603 series

TOSHIBA Photo-IC Silicon Epitaxial Planar TPS856

TC7WB66CFK,TC7WB66CL8X TC7WB67CFK,TC7WB67CL8X

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

TEST REPORT. Test Method : See the attached sheets.

CHAPTER 3 HELIPORT AND HELICOPTER STAGEFIELD LIGHTING SYSTEMS

MODEL NAME : LLDMWW0-15K*0*A

FOR PROJECTS INITIATED AFTER NOVEMBER 1, 2008 ITEM 716 EMBANKMENT EARTH OUTLET SEDIMENT TRAP

POWER PUSHER Snowplow

SHP-TS GroLux. SHP-TS 600W GroLux PRODUCT OVERVIEW

Combining superior high lumen, design & performance

KTC LED.PowerSpot 6W LED

A Rain Sensitive House Window Closes Automatically When Raining

Optimal light performance for short or long operation per switch-on Multiple light color choice Good color rendering (CRI > 80)

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

M2 SERIES THERMOSTATS 0 F to 240 F, Narrow Differential, Hermetically Sealed ½

10-year industry best core warranty. 2-year warranty on balance of unit.

6 + WARNING: CHOKING HAZARD - Small parts/small ball(s). Not for children under 3 years.

LM Test Report. for. Forest Lighting Corporate. LED Tube. Model: FL-T8U BN

Thermal Calculation for Linear Regulator

THE KENTON COUNTY SCHOOL DISTRICT LIGHTING SUPPLIES BID TABULATION 2009

BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL MODEL R7K4DH-1-DAC32D R7K4DH-1-DAC32D

4.5W LED. 4.5W GU10 PAR16 and G5.3 MR16 Lamp DATA SHEET. Features. Safety and Maintenance

Operating instructions Vortex flow meter. SVxxx / / 2015

EX-EMERGENCY LIGHT FITTINGS

LED light engines LED linear / area

Technical Application Guide

Test Report. Report No.: EED35I R1. Address : 701 Millennium Boulevard Greenville, SC : P , P , P , P

Test Report. Report No.: EED35I Address : 701 Millennium Boulevard Greenville, SC : P , P , P , P

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact

Instruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution

Lamp and Control Panel (Lamp Panel)

www. ElectricalPartManuals. com Flexitest Switch Assemblies Type FT-19R and FT-19RX INTL APPLICATION

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

TC74HC155AP, TC74HC155AF

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P320-3 umodule SPOT PHASED OUT 46,5 39,5 35,5 NTC NTC LED + LED 8,5 4,5 8,5

RIGID PVC CONDUIT FITTINGS AND ACCESSORIES

Technical Application Guide for Phaeton LED Floodlight

Protective Coatings: Non-lead orange paint RAL red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-153.

Table of Contents. DS133 LUXEON TX Product Datasheet Lumileds Holding B.V. All rights reserved.

TC4028BP, TC4028BF TC4028BP/BF. TC4028B BCD-to-Decimal Decoder. Pin Assignment TOSHIBA CMOS Digital Integrated Circuit Silicon Monolithic

Operating Instructions for Digital Manometer. Model: MAN-SD

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Old Conejo Road #118, Newbury Park, CA, 91320

TOSHIBA Photo IC Silicon Epitaxial Planar TPS859

Book 14 Edition 1.1 March Socketable Flat LED Module and LED Light Engine

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

Product family data sheet

Transcription:

Project Type Model # emarks Description :Firehorse Emergency Ballast for use with or without AC ballast designed to add emergency lighting when main AC power is interrupted for minimum of 90 minutes at reduced illumination. The e ergency ballast is not intended for general purpose lighting applications. This Ballast Will Operate Following Single/Bi-Pin/4-Pin Lamps. ONE O TWO 17W TO 40W(2-4 ) T8/T10/T12 O ONE 17W TO 110W (2-8 ) T8/T10/T12 INCLUDING COMPACT, HO, VHO, U-SHAPED, CICLINE, 4-PIN LONG COMPACT O MOST 17W TO 215W (2-8 ) T8/T10/T12 O ONE 8W TO 54W T5 FLUOESCENT LAMP AT EDUCED INITIAL ILLUMINATION (ALL WITHOUT INTEGAL STATE) TIPLE(CFT/E) ELECTICAL DATA IN P U T V O L T : 1 20 V O 27 7 V ± 1 0 %, 6 0 H z A P P O V A L C L A S S U L - L IS TE D F O D A M P L O C A T IO N FA C T O Y O FI E L D IN S T A L LA T I O N C O D E C O M P L I A N C E A C IN P U T P O W E A TI N G A C IN P U T C U E N T B A LL A S T TY P E M IN IM U M I L L U M IN A TI O N T IM E E C H A G E T I M E M A X IM U M IN IT I A L L IG H T O U T P U T B A TT E Y T YP E 2D28/38W T8/T12 T8 FT (LONG) T12/T12HO M E E TS O E X C E E D S U L 9 2 4 N. E.C. A N D L S C E M E G E N C Y O P E A TI N G E Q U I E M E N T 8. 0 W A T T S 2 8 0 m A E M E G E N C Y 9 0 M IN U T E S 2 4 H O U S 3 0 0 0 L U M E N S T E M P E A T U E A T I N G (A M B I E N T ) 0 C TO 5 0 C (3 2 F T O 1 2 2 F) B A TT E Y V O L T A G E H IG H T E M P E A T U E E C H A G A B L E N I -C A D M A IN T E N A N C E F E E 1 4.4 V d c B A TT E Y C H A G IN G C U E N T 2 8 0 m A M a x. B A TT E Y A T I N G M IN IM U M B A T T E Y A T IN G T E S T S W IT C H C H A G I N G IN D IC A TO LI G H T C A S E TY P E C A S E C O N S T U C T I O N C A S E P O F IL E 5 7.6 W h 4. 0A h S I N G L E P O L E L E D C A S E W E IG H T 9. 2 lb s. A C B A L LA S T C O M P A T IB I L IT Y L A M P C O M P A T I B IL I TY F IX T U E C O M P A TI B IL I T Y W I E C O N N E C T IO N (S T A N D A D ) L E D T E S T S W IT C H TY P E (S TA N D A D ) V A N D A L E S I S T A N T S E A L E D P A I N T E D S T E E L 1 6.3 L X 5.5 W X 1. 7 H X 1 5.1 0 M O U N T IN G C E N T E E L E C T O N IC F L U O E S C E N T S T A N D A D A N D D IM M IN G F L U O E S C E N T S I N G L E / B I-P I N / 4 -P IN W IT H O U T S T A TE I N D O O S W I T C H E D A N D U N S W IT C H E D T Y P E S I N G L E FL E X C O N D U IT W H I P /S T D. L E A D S O N E E N D T E S T S W I T C H & L E D IN D I C A T O T5 T10 FCT5 MECHANICAL DATA TABLE 1 LUMEN OUTPUT CHAT 5.56 1.88 4xØ0.25 0.12 15.75 16.25 15.43 4.00 FH6-DUAL-3000L INITIAL LUMEN OUTPUT WATTS BASE TYPE WITHOUT INTEGAL STATE 1 LAMP 2 LAMPS T12 40 G13/med-bipin 2600-2700 2600-2700 F96T12 75 FA8/single pin 2800 X F48T12HO 60 17D/EC 3000 X F96T12HO 95 17D/EC 2900 X F96T12VHO 215 17D/EC 2900 X T8 25 G13/med-bipin 2250 X T8 32/40 G13/med-bipin 3000 X F96T8 59 FA8/single pin 3000 X FT(LONG) 39/36 2G11 2850 2850 FT(LONG) 40/30/50/55 2G11 1800 X F2D/4P 28/38 G10Q-4 1800-2800 1800-2800 FCT5 55 2GX13 2700 X T5/T5HO 28/54 mini-bipin 2500-2700 X CFT 42 GX24Q-4 2900-3000 2900-3000 CFT 57/70 GX24Q-4 2700-2800 X Where : L = Length, W = Width, H = Height all in inches Partial list of lamps operated - contact Fulham Customer Service when referencing alternative lamps - lumen ratings may vary with lamp specifications, light loss, lamp and luminaire maintenance and other utilization factors. NOTE: WIING DIAGAMS SHOWN ON A SEPAATE SHEET 2006-126-1 rev G

APPLICATION The FireHorse emergency ballast can be used to add emergency lighting with or without an AC ballast and with most fluorescent fixtures without affecting normal fixture operation. The emergency ballast is designed for factory or field installation and can be mounted on top, inside, or remote from the fixture. If used in an emergency-only fixture, no AC ballast is required. The FireHorse emergency ballast is not suitable for use in air handling heated air outlets, outdoor, wet, or hazardous locations. The emergency ballast should not be installed near gas or electric heaters. The FireHorse emergency ballast is rated for Indoor Dry/Damp locations and for sealed and gasketed fixtures, including fixtures rated for wet locations. OPEATION The FireHorse emergency ballast is designed to immediately switch to the emergency mode when the primary AC power is interrupted, illuminating one or two lamps at a reduced lumen output for a minimum of 90 minutes. Upon restoration of primary AC power; the FireHorse emergency ballast immediately returns to a battery charging mode. The LED indicator light source when illuminated indicates battery is in charge mode when AC power is applied. It is recommended and by code required to test the emergency ballast every 30 days to ensure that the ballast is functioning as evidenced by reduced illumination of one or two lamps when pushing the test switch. It is also recommended a 90 minute discharge test is performed one time every 12 months. INSTALLATION The FireHorse emergency ballast may be used with either a switched or un-switched fixture. If a switched fixture is used, an un-switched hot lead must be connected to the emergency ballast to ensure the ballast remains in an uninterrupted charge condition while primary AC power source is active. eference Installation Instructions for appropriate wiring or contact Fulham Customer Service. The FireHorse emergency ballast must be fed from the same branch circuit as the AC ballast. The FireHorse emergency ballast may be remote-installed up to half the distance the AC ballast manufacturer recommends for remote mounting the AC ballast from the lamp, or up to 50 feet, whichever is less distance. The remote test switch plate may be mounted within 50 feet of the fixture and is subject to NEC and applicable local electrical code. Installation is not recommended with fixtures where the ambient temperature may fall below 0 C for extended periods as this may affect the operation of the emergency ballast. and CODE COMPLIANCE The FireHorse emergency ballast has been tested by Underwriters Laboratories in accordance with the standards contained in 924, Emergency Lighting and Power Equipment, and is approved for factory or field installations. Emergency illumination time meets or exceeds the National Electrical Code (NEC), Life Safety Code (NFPA-LSC) and 90 minute requirements. BATTEY The FireHorse emergency ballast contains a uniquely constructed, high-temperature rechargeable nickel cadmium battery. The battery is sealed within the ballast housing and is not replaceable. The battery must be recycled or disposed of properly and in compliance with federal, state and local regulations. EMEGENCY ILLUMINATION Illumination output varies with number of lamps, either 1 or 2 lamps, and lamp wattage requirement. The FireHorse model FH6-DUAL-3000L is designed to produce 1800-3000 initial emergency lumens output; if model works with 2 lamps the total initial lumens is distributed between the 2 illuminated lamps. efer to Table 1 for average lumen output for selected lamps. SPECIFICATION Emergency lighting shall be provided by using a FireHorse emergency ballast with a standard fluorescent fixture equipped with or without an AC ballast. The emergency ballast shall be capable of operating one or two fluorescent lamps as referenced in Table 1. The emergency ballast shall conform to specifications contained in Electrical Data Table and comply with standards set forth by the current NEC. The emergency ballast shall be approved for installation on top, inside, or remote from the fixture. NOTE: USE OF LOW MECUY, LAMPS A growing number of fluorescent lamp manufacturers have reduced the level of mercury content in their products. While this is helpful to the environment, the lower mercury content makes the lamp more difficult to start in emergency mode, particularly in a compact fluorescent cold-start emergency-only application without an AC ballast. Please contact Fulham Customer Service for further assistance if needed. 2006-126-2 rev G

EMEGENCY BALLAST AND AC BALLAST MUST BE FED FOM THE SAME BANCH CICUIT. TYPICAL SCHEMATICS ONLY. MAY BE USED WITH OTHE BALLASTS. CONST THE FACTOY FO OTHE WIING DIAGAMS E. ONE (1) LAMP INSTANT STAT BALLAST F. TWO (2) LAMP INSTANT STAT BALLAST G. THEE (3) LAMP INSTANT STAT BALLAST H. FOU (4) LAMP INSTANT STAT BALLAST I. ONE (1) 4-PIN COMPACT LAMP APID STAT BALLAST J. TWO (2) 4-PIN COMPACT LAMP APID STAT BALLAST WIE MUST BE GOUNDED 2006-126-3 rev G

EMEGENCY BALLAST AND AC BALLAST MUST BE FED FOM THE SAME BANCH CICUIT. TYPICAL SCHEMATICS ONLY. MAY BE USED WITH OTHE BALLASTS. CONST THE FACTOY FO OTHE WIING DIAGAMS WIING DIAGAMS FO 1-LAMP EMEGENCY OPEATION cont d. K. ONE (1) LAMP CICLINE APID STAT BALLAST L. TWO (2) LAMP CICLINE APID STAT BALLAST WIING DIAGAMS FO 2-LAMP EMEGENCY OPEATION EMEGENCY BALLAST AND AC BALLAST MUST BE FED FOM THE SAME BANCH CICUIT Two-lamp emergency operation is not possible with all ballasts. Consult the factory for any ballast other than those shown. M. TWO (2) LAMP APID STAT BALLAST N. TWO (2) LAMP INSTANT STAT BALLAST O. THEE (3) LAMP APID STAT BALLAST P. THEE (3) LAMP INSTANT STAT BALLAST NOTE: USE POPE CAPS TO TAP UNUSED LEADS 2006-126-4 rev G

EMEGENCY BALLAST AND AC BALLAST MUST BE FED FOM THE SAME BANCH CICUIT. TYPICAL SCHEMATICS ONLY. MAY BE USED WITH OTHE BALLASTS. CONST THE FACTOY FO OTHE WIING DIAGAMS WIING DIAGAMS FO 2-LAMP EMEGENCY OPEATION cont d. Q. FOU (4) LAMP APID STAT BALLAST. FOU (4) LAMP INSTANT STAT BALLAST WIING DIAGAMS FO EMEGENCY-ONLY FIXTUES S. ONE (1) LAMP WITHOUT AC BALLAST T. TWO (2) LAMPS WITHOUT AC BALLAST U. ONE (1) 4-PIN COMPACT LAMP WITHOUT AC BALLAST V. TWO (2) 4-PIN COMPACT LAMPS WITHOUT AC BALLAST NOTE: USE POPE CAPS TO TAP UNUSED LEADS 2006-126-5 rev G

4-PIN(gr10q) 2006-126-6 rev G