COST MP0601 Short Wavelength Laboratory Sources

Similar documents
Check the LCLS Project website to verify 2 of 6 that this is the correct version prior to use.

X-Rays From Laser Plasmas

Optimization of laser-produced plasma light sources for EUV lithography

object objective lens eyepiece lens

Ultrafast X-Ray-Matter Interaction and Damage of Inorganic Solids October 10, 2008

Analysis, simulation, and experimental studies of YAG and CO 2 laserproduced plasma for EUV lithography sources

Application of a Laser-Wakefield Driven Monochromatic Photon Source to Nuclear Resonance Fluorescence

Basic physics Questions

Fadei Komarov Alexander Kamyshan

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source

MSN551 LITHOGRAPHY II

Multilayer Interference Coating, Scattering, Diffraction, Reflectivity

Laser heating of noble gas droplet sprays: EUV source efficiency considerations

EUV lithography and Source Technology

Metallic nanoparticles in proton therapy: how does it work? Dr. Anne-Catherine Heuskin University of Namur 3 rd BHTC workshop

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

Damage to Molecular Solids Irradiated by X-ray Laser Beam

Coulomb crystal extraction from an ion trap for application to nano-beam source"

LASER-COMPTON SCATTERING AS A POTENTIAL BRIGHT X-RAY SOURCE

Irradiation of Living Cells with Single Ions at the Ion Microprobe SNAKE

A Straight Forward Path (Roadmap) to EUV High Brightness LPP Source

Developments for the FEL user facility

MICRO AND NANOPROCESSING TECHNOLOGIES

High Yield Structured X-ray Photo-Cathode Development and Fabrication

Edge Radiation IR end-station at ESRF

Shell Atomic Model and Energy Levels

EXTREME ULTRAVIOLET AND SOFT X-RAY LASERS

The scanning microbeam PIXE analysis facility at NIRS

Radiation Quantities and Units

Centre for Electronic Imaging

SOFT X-RAYS AND EXTREME ULTRAVIOLET RADIATION

Construction of an extreme ultraviolet polarimeter based on highorder harmonic generation

Introduction to Synchrotron Radiation

Ba (Z = 56) W (Z = 74) preferred target Mo (Z = 42) Pb (Z = 82) Pd (Z = 64)

Swanning about in Reciprocal Space. Kenneth, what is the wavevector?

Modern Developments in X-Ray and Neutron Optics

Supplementary Figure 1 Detailed illustration on the fabrication process of templatestripped

Rad T 290 Worksheet 2

Astronomy 203 practice final examination

Name: COMBINED SCIENCE Topics 4, 5 & 6 LEARNING OUTCOMES. Maintain a record of your progress Use the booklet to guide revision

Development and characterization of 3D semiconductor X-rays detectors for medical imaging

Fundamental investigation on CO 2 laser-produced Sn plasma for an EUVL source

A facility for Femtosecond Soft X-Ray Imaging on the Nanoscale

We have seen how the Brems and Characteristic interactions work when electrons are accelerated by kilovolts and the electrons impact on the target

Radiative Hydrodynamic Simulation of Laser-produced Tin Plasma for Extreme Ultraviolet Lithography

Physik und Anwendungen von weicher Röntgenstrahlung I (Physics and applications of soft X-rays I)

Quantitative determination of the effect of the harmonic component in. monochromatised synchrotron X-ray beam experiments

SUPPLEMENTARY INFORMATION

LET! (de / dx) 1 Gy= 1 J/kG 1Gy=100 rad. m(kg) dose rate

Shielding of Ionising Radiation with the Dosimetry & Shielding Module

Far IR Gas Lasers microns wavelengths, THz frequency Called Terahertz lasers or FIR lasers At this wavelength behaves more like

X-Ray Radiation Channeling through Micro-Channel Plates: spectroscopy with a Synchrotron Radiation Beam

Detecting high energy photons. Interactions of photons with matter Properties of detectors (with examples)

INTRODUCTION TO IONIZING RADIATION (Attix Chapter 1 p. 1-5)

Carbon Dating The decay of radioactive nuclei can be used to measure the age of artifacts, fossils, and rocks. The half-life of C 14 is 5730 years.

EXPERIMENTS CHARACTERIZING THE X-RAY EMISSION FROM A SOLID-STATE CATHODE USING A HIGH-CURRENT GLOW DISCHARGE

Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist

EUV Reflectivity measurements on Acktar Sample Magic Black

Problem Solving. radians. 180 radians Stars & Elementary Astrophysics: Introduction Press F1 for Help 41. f s. picture. equation.

Shielding Design for the Imaging and Medical Beamline at the Australian Synchrotron

Radiation Safety at LCLS: The Photon Beam s Maximum Capability and Material Damage Potential

The MID instrument.

Wolter Imaging On Z. Chris Bourdon, Manager Z Imaging and Spectroscopy Julia Vogel, LLNL; Ming Wu, SNL ICF Diagnostics Workshop, October 5 th 2015

SLS Symposium on X-Ray Instrumentation

An Introduction to Diffraction and Scattering. School of Chemistry The University of Sydney

CVD Diamond History Introduction to DDL Properties of Diamond DDL Proprietary Contact Technology Detector Applications BDD Sensors

Pushing the limits of laser synchrotron light sources

High Yield Structured X-ray Photo-Cathode Development and Fabrication

Bhas Bapat MOL-PH Seminar October Ion Matter Interactions and Applications

DR KAZI SAZZAD MANIR

X-ray photoelectron spectroscopy with a laser-plasma source

Photoelectron spectroscopy Instrumentation. Nanomaterials characterization 2

Spawning Neutrons, Protons, Electrons and Photons from Universities to Society

The Future of EUV sources: a FIRE perspective

Laser Plasma Monochromatic Soft X-ray Source Using Nitrogen Gas Puff Target

Radiation shielding for undulator beamline in Indus-2 synchrotron radiation source

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

FXA UNIT G485 Module X-Rays. Candidates should be able to : I = I 0 e -μx

J. M. Ablett and C. C. Kao National Synchrotron Light Source, Brookhaven National Laboratory, Upton, New York 11973

Laser Optics-II. ME 677: Laser Material Processing Instructor: Ramesh Singh 1

Radiation measurements around ESRF beamlines

is the minimum stopping potential for which the current between the plates reduces to zero.

EDS User School. Principles of Electron Beam Microanalysis

Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist

X-RAY SCATTERING AND MOSELEY S LAW. OBJECTIVE: To investigate Moseley s law using X-ray absorption and to observe X- ray scattering.

Pulsed-power based bright EUV light source for metrology

Spectroscopic Studies of Soft X-Ray Emission from Gadolinium Plasmas

MEDICAL EQUIPMENT: NUCLEAR MEDICINE. Prof. Yasser Mostafa Kadah

Non-thermal emission from pulsars experimental status and prospects

188 L. Jakubowski and M.J. Sadowski temperature. Some examples of the registered X-ray images are shown in Fig.1. Figure 1. X-ray pinhole images from

X-Ray Nanoimaging: Instruments And Methods II (Proceedings Of SPIE)

Synchrotron radiation: A charged particle constrained to move in curved path experiences a centripetal acceleration. Due to it, the particle radiates


OPAC 101 Introduction to Optics

Radiation Safety Training Session 1: Radiation Protection Fundamentals and Biological Effects

2015 Ph.D. Comprehensive Examination III. Radiological Sciences - Medical Physics

Specific Accreditation Criteria Calibration ISO/IEC Annex. Ionising radiation measurements

The European XFEL in Hamburg: Status and beamlines design

Nova 600 NanoLab Dual beam Focused Ion Beam IITKanpur

LECTURE 4 PRINCIPLE OF IMAGE FORMATION KAMARUL AMIN BIN ABDULLAH

Transcription:

Background: Short wavelength radiation has been used in medicine and materials studies since immediately after the 1895 discovery of X-rays. The development of synchrotron sources over the last ~25 years has led to a boom in applications in other areas, including environmental science. Despite the widely acknowledged advantages of synchrotron radiation, there is not enough to go round. Due to the cost of such sources this is likely to remain the case. Hence the need to develop alternative, cheaper, more accessible sources which can offer at least some of the properties of synchrotrons. www.shortwavelengthsources.net International Workshop on EUV and Soft X-Ray Sources, Dublin, 10 October 2012 1

Objectives: To advance European research & development in laboratory scale short wavelength sources to widen access to research and analysis that currently can only be undertaken at large scale facilities such as synchrotrons and free electron lasers. WG1 Modelling & Simulation, giving direction to the wide range of experimental parameters that must be varied to optimise source output; WG2 Source Development, Improvement & Characterization, in order to provide optimum emission properties; WG3 Integrated Systems: Sources, Optics and Detectors, to ensure optimum use of the source output; WG4 Applications: the raison d'être for the developments of the above three working groups. International Workshop on EUV and Soft X-Ray Sources, Dublin, 10 October 2012 2

Results vs objectives: Through modeling emission characteristics, we now have a much enhanced understanding of the most important source parameters (WG1). We have identified further potential mechanisms for laboratory-scale short wavelength sources (WG2). Improved optics and detectors, developed within the Action both as a direct result of COST funding and through national / cross-national funds raised (in part) through the support of COST. have lead to more efficient use of the source output (WG3). The very wide range of cross-disciplinary applications which will be enabled by the work of the Action could not be envisaged by a single institution (WG4). International Workshop on EUV and Soft X-Ray Sources, Dublin, 10 October 2012 3

Some statistics: Countries involved 16 EU, 5 non-e Institutions involved About 70 People involved About 200, including 94 ESRs WG meetings 9 for each WG Workshops 3 Training schools 4 STSMs* 19 Total funding About 475,000 Publications >300 and rising Degrees awarded About 40 PhD and Masters New programmes About 10 EU, 20 national *Short-term scientific missions. International Workshop on EUV and Soft X-Ray Sources, Dublin, 10 October 2012 4

Some sources studied either theoretically, experimentally or both: Microfocus Laser-generated plasmas Discharge plasmas Pinch plasmas Table-top high-rep rate EUV and soft X-ray lasers Capillary soft X-ray lasers High harmonic generation Thomson back-scatter Laser wakefield Transition radiation Carbon nanotube field emission International Workshop on EUV and Soft X-Ray Sources, Dublin, 10 October 2012 5

Some applications: Radiobiology X-ray microscopy and spectromicroscopy Laser ablation, surface modification EUVL and mask inspection Fluorescence imaging Cultural heritage (many studies) Environmental science Analysis of thin films Microtomography Optics characterisation for X-ray astronomy and EUVL Security International Workshop on EUV and Soft X-Ray Sources, Dublin, 10 October 2012 6

We want to study a range of problems in radiation biology: How are biological cells damaged by ionising radiation? More specifically, how is response to radiation distributed across a cell? What is a safe dose? How significant is damage to components other than nuclear DNA? Prior to the development of a focused X-ray microprobe some results, using α particles, suggested that cytoplasm damage (presumably mitochondrial DNA) may be important. Can damage effects be transmitted to un-irradiated cells the bystander effect? Statistical analyses of experiments with unfocused X- ray beams had previously suggested that they may be. International Workshop on EUV and Soft X-Ray Sources, Dublin, 10 October 2012 7

Historically, experiments using X-rays to study radiation damage were carried out using unfocused beams. The low-dose responses of cells were hard to determine; with soft X-rays, the dose imparted by a few photons is damaging (1 Gy =1 J/kg ~10 absorbed carbon K photons in a cell nucleus). But if the beam is unfocused, the precise dose to each cell is unknown. How is response to radiation distributed across a cell? How significant is damage to components other than nuclear DNA? Can damage effects be transmitted to un-irradiated cells the bystander effect? International Workshop on EUV and Soft X-Ray Sources, Dublin, 10 October 2012 8

Microprobing of biological cells using sub-micrometre spots of focused carbon K X-rays (284 ev) has been very successful in studies relevant to radiation-induced cancers, including: Low-dose effects, including low-dose hypersensitivity (what is a safe dose?). Is this a good thing or a bad thing? What is the main source of the high dose data? What is the third (=) highest source of radiation dose to humans? International Workshop on EUV and Soft X-Ray Sources, Dublin, 10 October 2012 9

The bystander effect; if only one cell out of a population in a dish is irradiated, up to ~10% do not survive. Comparison of cytoplasm and nucleus irradiation; around the same percentage of cells seems to survive irrespective of whether the nucleus or cytoplasm is specifically irradiated. This suggests that damage to both nuclear and mitochondrial DNA is important. International Workshop on EUV and Soft X-Ray Sources, Dublin, 10 October 2012 10

However, there are problems... There will always be some cytoplasm irradiation even when the nucleus is targeted. Hence it is hard to disentangle the two effects more data are needed. C K X-rays can only penetrate one cell; essentially zero are unabsorbed. Tissue samples, much more important for radiation effects in living organisms, cannot be studied. To study tissue samples higher energies are needed; Cr K a (5.4 kev) X-rays are suitable. So far it has only been possible to study effects related to cell death, rather than. Fortunately, mutations are much rarer; at low doses only ~1 in 10 4 cells mutate the rest repair correctly or die. Very few of those that do mutate are potentially cancerous. International Workshop on EUV and Soft X-Ray Sources, Dublin, 10 October 2012 11

Experiments so far have been done using zone plates, with the focal spot size limited by the source size. With a source size 5-25 μm, as obtained with the microfocus source used so far, the focal spot size is 0.2-1 μm for C K but would be 4-20 μm for Cr because of the increased focal length. The focused flux is limited by the monochromatic source output and the efficiency and aperture of the optic (A eff ~10 9 for a typical zone plate). International Workshop on EUV and Soft X-Ray Sources, Dublin, 10 October 2012 12

To be able to study mutation effects in tissue samples, and to disentangle nucleus/cytoplasm effects, need some or all of: higher source output; smaller source size ( 1 μm); higher demagnification; higher efficiency and/or aperture optic all at kev energies with 24/7 access. These factors define the design goals of the new microfocus source and associate optics. International Workshop on EUV and Soft X-Ray Sources, Dublin, 10 October 2012 13

How can we get a 1 μm source size? The accelerating voltage must be low, to optimise K X-ray production, limit secondary electron range and prevent high energy Bremsstrahlung - 15 kev was selected as suitable for ~5 kev X-rays. This limits the beam current, to reduce divergence which would increase the electron focus size. FEA calculations show that ~1 ma can be focused into a ~1 μm spot, a power density of ~2x10 13 W/m 2. The original plan was a Ti target (4.5 kev), but at such a power density Ti will melt (FEA), even with cooling, due to its low melting point (1935 K) and conductivity (22 W/m/K). Instead use liquid N 2 cooled (?) chromium, melting point 2180 K and thermal conductivity 94 W/m/K. International Workshop on EUV and Soft X-Ray Sources, Dublin, 10 October 2012 14

Improving the Optics: Micro-Structured Optical Arrays Arrays of channels etched into silicon. By using single grazing incidence reflections in each of two arrays aberrations can be reduced. Bending the arrays can reduce aberrations further and give variable focal length. Prototype design for 5.4 kev: 10 μm channels, 20 μm period 2 mm diameter (2 mm square for 1D prototype) 50-200 μm thick silicon second component bending radius 5 cm focal length 5 cm. With 1 nm (AFM measurement) sidewall roughness this gives over 100 as much focused flux as a typical zone plate - even more if Bremsstrahlung can be used. International Workshop on EUV and Soft X-Ray Sources, Dublin, 10 October 2012 15

Improving the Optics: Micro-Structured Optical Arrays 1st (unbent) array only 2nd (bent) array only Both arrays Focal spot size: 0.3 μm (point source) 0.35 μm (1 μm source) 2 smaller than for a single reflection 2.5 smaller than for a typical zone plate International Workshop on EUV and Soft X-Ray Sources, Dublin, 10 October 2012 16

Improving the Optics: Micro-Structured Optical Arrays International Workshop on EUV and Soft X-Ray Sources, Dublin, 10 October 2012 17

Improving the Optics: Micro-Structured Optical Arrays The reflectivity of an etched array was measured at 500 ev by relatively rotating the source and array in front of a CCD. 0 is the angle at which most X-rays should be reflected. Away from 0 the count rate falls since more X-rays pass straight through (negative angles) or are multiply reflected (positive). Reflectivity was expected over a range of 5. The fitted Gaussian peak is at 0.2, with a FWHM of 5.3. The peak reflectivity is a few percent (at a much larger glancing angle than will be used in practice), consistent with the measured channel wall roughness. International Workshop on EUV and Soft X-Ray Sources, Dublin, 10 October 2012 18

Improving the Optics: Micro-Structured Optical Arrays Reflection from a single array has also been demonstrated using the King s microfocus source with an aluminium target (K α 1.5 kev). 0.015 0.026 0.032 0.05 0.062 International Workshop on EUV and Soft X-Ray Sources, Dublin, 10 October 2012 19

Summary Soft X-ray microprobes have demonstrated their use in studying a range of problems in radiation biology of single cells. But to extend these studies to mutation effects in tissue samples, it is necessary to: Use higher energy X-rays; Deliver more focused flux. It seems feasible that these goals can be achieved by: Using a chromium microfocus source with a 1μm source size; Using microstuctured optical array optics, with A eff >100x that of a typical zone plate. International Workshop on EUV and Soft X-Ray Sources, Dublin, 10 October 2012 20

EXTATIC The Future Extreme-ultraviolet & X-ray Technology And Training for Interdisciplinary Cooperation COST MP1203 Advanced Spatial and Temporal X-ray Metrology Kick-off: Brussels, 16 November www.cost.eu International Workshop on EUV and Soft X-Ray Sources, Dublin, 10 October 2012 21