Extrel is widely respected for the quality of mass spectrometer systems that are

Similar documents
Catalysis CAPABILITIES

Extrel Application Note

Application Note GA-301E. MBMS for Preformed Ions. Extrel CMS, 575 Epsilon Drive, Pittsburgh, PA I. SAMPLING A CHEMICAL SOUP

Hiden HPR60 Molecular Beam Mass Spectrometer System

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Thermo Finnigan LTQ. Specifications

Finnigan LCQ Advantage MAX

vacuum analysis plasma diagnostics surface science gas analysis

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Jumbo Cross Beam Ionizer

Pressure & temperature sampling options for Hiden gas analysis systems

Introduction to the Q Trap LC/MS/MS System

IRMS. perspective. Isotope Ratio Mass Spectrometry.

SIFT-MS. technology overview

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

Application of the EQP and EQS mass spectrometers to time resolved studies in ion beam and plasma processes

FSA TM Multi-bit Digital Processors

Hiden EQP Systems. High Sensistivity Mass and Energy Analyzers for Monitoring, Control and Characterization of Ions, Neutrals and Radicals in Plasma.

Mass Spectrometers. for Surface Analysis SURFACE ANALYSIS

THIN FILMS, PLASMA & SURFACE ENGINEERING. Mass Spectrometers. for Thin Films, Plasma & Surface Engineering

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

Defining quality standards for the analysis of solid samples

FT-ICR Mass Spectrometer QUANTRA. Technical Description September quantra

ICP-MS. High Resolution ICP-MS.

Mass Spectrometry in MCAL

SURFACE ENGINEERING MASS SPECTROMETERS FOR THIN FILMS, PLASMA AND SURFACE ENGINEERING

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

CapaciTorr HV Pumps. making innovation happen,together

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

TANDEM MASS SPECTROSCOPY

TPD-MS. Photocatalytic Studies Using Temperature Programmed Desorption Mass Spectrometry (TPD-MS) APPLICATION NOTE NOTE

Introduction to Fourier Transform Infrared Spectroscopy

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

COPLEY S C I E N T I F I C. A multi-function aerosol system with aerosol generation, classification and monitoring capabilities for:

CapaciTorr HV 200 HIGHLIGHTS

6.5 Optical-Coating-Deposition Technologies

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

STANDARD OPERATING PROCEDURE (SOP) FOR THE FIELD OPERATION OF THE AERODYNE AEROSOL MASS SPECTROMETER (AMS)

1. The range of frequencies that a measurement is sensitive to is called the frequency

In-situ Ar Plasma Cleaning of Samples Prior to Surface Analysis

Hiden Analytical Ltd

PERSPECTIVE STABLE ISOTOPE RATIO MS

ActiPix SDI300 Surface Dissolution Imaging System

PERSPECTIVE STABLE ISOTOPE RATIO MS

Introduction to Fourier Transform Infrared Spectroscopy

DPP06 Meeting of The American Physical Society. Production of negative ion plasmas using perfluoromethylcyclohexane (C 7 F 14 )

of mass spectrometry

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Hiden CATLAB Systems Microreactor for Catalysis Studies & Thermal Analysis

473-SHX Dew Point Mirror

(Refer Slide Time 00:09) (Refer Slide Time 00:13)

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph

MetWorks Metabolite Identification Software

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

RESIDUAL GAS ANALYSIS MASS SPECTROMETERS FOR RESIDUAL GAS ANALYSIS - RGA

novaa 800 D Atomic Absorption Spectrometer

CEE 772 Lecture #27 12/10/2014. CEE 772: Instrumental Methods in Environmental Analysis

Courtesy of ESS and TheRGA web pages part of a series of application and theory notes for public use which are provided free of charge by ESS.

Quantum Technology: Supplying the Picks and Shovels

CEE 772: Instrumental Methods in Environmental Analysis

NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT

Quadrupole Mass Spectrometry Concepts. Mass spectrometers for residual gas analysis: Intermediate Level Users Guide

1/5 Specifications Hidex 300 SLL automatic TDCR liquid scintillation counter

473 Dew Point Hygrometer

HYPHENATED TECHNOLOGY GUIDE

ETCHING Chapter 10. Mask. Photoresist

Atomic Absorption Spectrometer ZEEnit P series

CATALYSIS & THERMAL ANALYSIS

HYPHENATED TECHNOLOGY GUIDE

Types of Analyzers: Quadrupole: mass filter -part1

C101-E112. BioSpec-nano. Shimadzu Spectrophotometer for Life Science

Owlstone Nanotech Inc

HELIX MC Plus. Static Vacuum. ARGUS VI Thermo Scientific HELIX MC Plus Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

Mass Analyzers. mass measurement accuracy/reproducibility. % of ions allowed through the analyzer. Highest m/z that can be analyzed

ULTRA-SENSITIVE SOLUTIONS FOR REAL-TIME TRACE GAS ANALYSIS

Powerful Scan Modes of QTRAP System Technology

Approval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Thermo VG PQ EXCELL INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER

Calibration of Particle Instruments in Space Physics

Translational Biomarker Core

MS/MS .LQGVRI0606([SHULPHQWV

Sputter Ion Pump (Ion Pump) By Biswajit

MAX300-BIO Bioreactor and Fermentation Gas Analyzer. Providing Solutions for Gas Analysis

Agilent s New 8800 ICP-QQQ. Transforming ICP-MS Technology

ICP-MS. plasma 17OO. High Resolution Multi-Collector ICP-MS.

cobas e 411 analyzer Confidence in every result.

Mass Analyzers. Principles of the three most common types magnetic sector, quadrupole and time of flight - will be discussed herein.

473 Dew Point Hygrometer

Mass Spectroscopy. Base peak. Molecular Ion peak. The positively charged fragments produced are separated, based on their mass/charge (m/z) ratio. M+.

10/8/2013. Alternatives to Mass Spectrometry and Some Real-time Monitoring Measurements. Project Driven Tasks -- Process Gas Measurements

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219

HIGH PERFORMANCE MASS SPECTROMETERS FOR EARTH AND PLANETARY SCIENCE

DI 3500 Discrete Aoalvzer

Parametric down-conversion

Secondary Ion Mass Spectrometry (SIMS)

MS Goals and Applications. MS Goals and Applications

Transcription:

Extrel is widely respected for the quality of mass spectrometer systems that are available to the world's top research scientists. In response to increasing requests for complete turn-key systems built around their well-respected quadrupole mass spectrometer technology, Extrel has introduced the VeraSpec line of research grade mass spectrometer systems. The Extrel VeraSpec MB2 and VeraSpec MB3 molecular beam mass spectrometer systems are compact systems, which utilize a 2- or 3-stage skimmer inlet with interstage optics for the analysis of gases and ions, including from plasma, from 2 mtorr up to pressures greater than one atmosphere. With appropriate apertures, fast and accurate measurement of positive ions, negative ions, and neutral species directly from the sample is accomplished. Neutral species detection can be extended to include radicals, with fragment identification, via threshold ionization (appearance potential studies) and dissociative electron attachment ionization. Configured with the optional beam chopper and lock-in amplifier, the signal-tonoise ratio can be significantly improved. 2

Extrel VeraSpec MB systems feature our crossbeam deflector ionizer (below) and can be customized with a chopper and lock-in amplifier (left) Applications: Medium and high pressure plasma diagnostics Plasma Enhanced Chemical Vapor Deposition (PECVD) Low Pressure Chemical Vapor Deposition (LPCVD) Plasma Etch Atmospheric Chemistry Effusive gas source analysis System Highlights: VeraSpec MB2 Sampling from source pressures of 2 mtorr to 100 Torr Biasable first aperture with a diameter of 100 μm to 3 mm depending on source pressure VeraSpec MB3 Sampling from source pressures of 100 Torr to 2 atm Biasable first aperture or sampling tube depending on source pressure MB2 and MB3 Cross Beam Deflector Ionizer deflects ions 90 off-axis, separating ions from common background noise sources such as photons, metastables, particulates, and molecular beam gases. Analog and positive ion counting Negative ion/electron attachment option Signal gating option (beamchopper and lock-in amplifier) Merlin Automation data system 3 RPM100B

Molecular Beam Sampling for Gas Analysis The power of mass spectrometry as an analytical technique is well known, and mass spectrometers have been widely used for residual gas analysis. However, for samples that are not a residual gas contained in the mass spectrometer vacuum chamber, an effective sampling arrangement must be used. Among the possibilities, molecular beam sampling is an effective way to introduce neutral gas or pre-formed ion samples over a wide range of sample conditions. Three molecular beam systems are available to suit the broadest application requirements: the VeraSpec MB2, VeraSpec MB3, and VeraSpec MBx. The MB2 and MB3 systems are 2- and 3-stage molecular beam inlet systems, designed for analysis of neutrals or ions from 2 mtorr up to 2 atm. These systems are ideal for plasma diagnostics, chemical vapor deposition, and other similar applications. The MBx system is a 3-stage discreetly pumped gas analysis system for extreme samples. All systems can be modified for an even broader range of sample conditions with the help of Extrel's experienced engineers and application scientists. 4

MAX Performance The heart of a VeraSpec MB system is Extrel's MAX Series flange mounted quadrupole mass spectrometer system.the MAX system consists of a mass spectrometer probe, including an electron impact ionizer, tri-filter quadrupole mass filter, and electron multiplier detector, the MAX-CS mass spectrometer Control System, and MAX-QCi integrated Quadrupole Control system. The 19 mm tri-filter quadrupole, with precision machined rod set, RF-only pre- and post-filter stages, and stabilizing rods, combine with the CS control system and the QCi quadrupole control RF supply to deliver excellent transmission, resolution and abundance sensitivity characteristics at all mass ranges. The whole system is operated via Extrel's Merlin Automation data system software. Table 1: MAX System Mass Range and Performance System with 19 mm Operating Mass Relative Resolution General Sensitivity (3/4") tri-filter Frequency Range Transmission (M/ΔM FWHM) (ma/ Torr) MAX-4000HT 440 khz 4-4000 50% 1500 0.75 MAX-1000 880 khz 1-1000 50% 1800 1 MAX-500HT 1.2 MHz 1-500 60% 2000 2 MAX-120 2.1 MHz 1-120 65% 2500 3 MAX-50 2.9 MHz 1-50 75% 3000 4 Performance shown here are minimum production requirements. Actual performance is typically better. 5 RPM100B

The Extrel VeraSpec MBx quadrupole mass spectrometer system is a 3-stage discreetly pumped, gas analysis system designed for sampling reactive and condensable gases. The MBx is designed with a heated inlet, easily-changed first aperture and skimmer, and an isolation gate valve, to allow inlet maintenance for applications, which have challenging sample conditions, such as pyrolysis. The carefully-engineered inlet provides a supersonic expansion of the sample into the vacuum to maintain sample integrity ensuring accurate analysis of analytes before they react or decompose. The System Highlights VeraSpec MBx is an integral part of the High Throughput Analytical Pyrolysis (HTAP) system, which was developed in collaboration between the National Renewable Energy Laboratory (NREL), Extrel, ArborGen, and Frontier Labs. The HTAP system is being used to accelerate the search for new and improved biofuel sources and has shown improvement in the analysis of pyrolysis products. Applications Pyrolysis Reactive Gas Analysis Condensable Gas Analysis Super Critical Fluid Sampling 6

Engineering and Application Support Extrel recognizes that every analytical requirement for a research project has its own unique demands. As with all of the VeraSpec research grade systems, Extrel's salespeople, engineers, and application scientists will work with you to understand your specific configuration needs for the VeraSpec MB systems. A variety of aperture sizes and pumping options are available, and custom variations based on the VeraSpec MB base systems create a flexible and powerful approach to providing a molecular beam quadrupole mass spectrometer for your research needs. System Highlights: VeraSpec MBx Sampling from source pressures of 100 Torr to 2 atm Optional to 100 atm Heated first aperture for condensable compounds Isolation gate valve to keep MS under vacuum during first stage maintenance Cross Beam Deflector Ionizer deflects ions 90 off-axis separating ions from photons, metastables, particulates, and molecular beam gases. This increases signal to noise by filtering out common and controllable causes of background noise. Analog and positive ion counting Negative ion/electron attachment option Signal gating option (beam chopper and lock-in amplifier) Merlin Automation data system 7 RPM100B

Installation Requirements: Recommended Power Supply: (3) 120 VAC, 50/60 Hz, 20 Amp circuit (3) 220 VAC, 50/60 Hz, 20 Amp circuit Ambient Temperature: 55 F to 80 F (13 C to 27 C) Relative Humidity: 0-90% non-condensing Area Classification: Laboratory/General Purpose Analyzer Weight: 450 480 lbs. (200 to 225 kg) Analyzer Dimensions: Height: 77" (196 cm) Depth: 30" (76 cm) Width: 30" (76 cm) Merlin Automation Data System Software: Control Unit: Information and control are transmitted and displayed via USB or CAT5E to a PC with Microsoft Windows 7 or XP operating system Analysis Mode: Scan Mode, Single Ion Monitoring (SIM), Multiple Reaction Monitoring (MRM) Analysis Rate: Maximum 80 microseconds per point in Scan Mode, typically 5 milliseconds per ion in SIM Number of Ions: Up to 72 ions with 20 scan segments Analog Inputs/Outputs: 10 or 20 channel, 12 bit, 0 to 10 V or -10 V to +10 V Outputs, 6 differential Analog Inputs, 12 bit, -10 V to +10 V Digital Inputs/Outputs: 8 Inputs, 8 Outputs, 16 User Selectable Input/Outputs (all I/O's 1 bit TTL) External Communications: Some supported, please refer to Extrel for more information Extrel CMS maintains sales and service offices around the world. Please contact us for the office nearest you or visit our website at www.extrel.com Extrel is a registered trademark of Extrel CMS, LLC. Merlin Automation is a trademark of Extrel CMS, LLC. VeraSpec is a trademark of Extrel CMS, LLC. Windows is a registered trademark of Microsoft Co. 2013 Extrel CMS, LLC RPM100B