IMPROVING DATA QUALITY WITH ADVANCED INSTRUMENTATION UTILIZING MULTIPLE INTERFERENCE REDUCTION TECHNOLOGIES

Similar documents
Analysis for Arsenic and Hexavalent Chromium:

Analysis of Trace Metal Impurities in High Purity Hydrochloric Acid Using ICP-QQQ

Accurate measurement of elemental impurities in metals and metal alloys using the Thermo Scientific icap TQ ICP-MS

Analytical Approaches to Arsenic

Simplified workflows for the Thermo Scientific icap TQ ICP-MS

Agilent s New 8800 ICP-QQQ. Transforming ICP-MS Technology

Lead isotope analysis: Removal of 204 Hg isobaric interference from 204 Pb using ICP-QQQ in MS/MS mode

Handling Interferences in the Modern Laboratory with Advanced Triple Quadrupole ICP-MS Technology

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

Fergus Keenan Shona McSheehy Julian Wills

Agilent s Solutions for Nanoparticles Analysis ICP-MS, ICP-MS/MS, software. Alain Desprez Agilent Technologies

Low Level Detection of Priority Inorganic Pollutants in Water. Anthony Neumann, MSc Darren Crichton, BSc

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Comparing Collision/Reaction Cell Modes for the Measurement of Interfered Analytes in Complex Matrices using the Agilent 7700 Series ICP-MS

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Application note. Trace level analysis of sulfur, phosphorus, silicon and chlorine in NMP using the Agilent 8800 Triple Quadrupole ICP-MS

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

Basic and Application Inductively coupled plasma mass spectrometry (ICPMS)

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

Agilent 8800 Triple Quadrupole ICP-MS: Understanding oxygen reaction mode in ICP-MS/MS

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

Trace Analyses in Metal Matrices Using the ELAN DRC II

Advances in Interference Removal for Accurate Arsenic Analysis in Food and Beverages

Agilent 8900 Triple Quadrupole ICP-MS

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Rapid, simple, interference-free analysis of environmental samples using the XSERIES 2 ICP-MS with 3 rd generation CCT ED

Agilent ICP-MS. Fundamentals of ICP-MS Analysis and Its Applications for Low Level Elemental Determination in Cannabis

Sample Analysis Design PART III

Ultra trace measurement of potassium and other elements in ultrapure water using the Agilent 8800 ICP-QQQ in cool plasma reaction cell mode

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

Advanced ICP-MS techniques for overcoming interferences in LA-ICP-MS bioimaging

JRP SIB09 Elements GOOD PRACTICE GUIDE ON DEALING WITH INTERFERENCES IN ICP-MS FOR INVESTIGATING HIGH PURITY MATERIALS. Deliverable 1.2.

Accurate Analysis of Trace Mercury in Cosmetics using the Agilent 8900 ICP-QQQ

Advantages of ICP-QQQ for nuclear waste characterisation

Application note. Accurate determination of sulfur in biodiesel using Isotope Dilution-Triple Quadrupole ICP-MS (ID-ICP-QQQ) Petrochemical

Implementing EPA Method 6020 with the Agilent ICP-MS Portfolio

Semiquantitative Screening of Pharmaceutical Antiviral Drugs using the Agilent 7500ce ICP-MS in Helium Collision Mode

Determination of Trace Metals in Human Urine Using the NexION 300 ICP-MS

Sample Analysis Design PART II

Theory, Design, and Operation of a Dynamic Reaction Cell for ICP-MS

Unmatched Removal of Spectral Interferences in ICP-MS Using the Agilent Octopole Reaction System with Helium Collision Mode Application

Accurate analysis of neptunium 237 in a uranium matrix, using ICP-QQQ with MS/MS

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

ICP-MS. plasma 17OO. High Resolution Multi-Collector ICP-MS.

Interference-free determination of ultra-trace levels of Arsenic and Selenium using methyl fluoride as reaction gas in ICP-MS/MS

Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Debjani Banerjee Department of Chemical Engineering IIT Kanpur

Lecture 7: Atomic Spectroscopy

Analysis of noble metals at low levels in geological reference materials and ores

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

Determination of Phosphorus and Sulfur with Dynamic Reaction Cell ICP-MS

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Outsmart Interferences with Triple Quadrupole ICP-MS. The world leader in serving science

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

The New Agilent 7700 Series ICP-MS

The 30-Minute Guide to ICP-MS

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

Sample Analysis Design Internal Standard

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

Very recently Roussis and Proulx clearly demonstrated

Sample Analysis Design Polyatomic Interferences

Agilent Technologies at TIAFT 2013

Opening the analytical black box: Insights into interferences, corrections, and data quality

Suppression of in-cell generated interferences in a reaction cell ICP-MS by bandpass tuning and kinetic energy discrimination

Use of ICP-MS in analysing radioisotopes. Per Roos Risø National Laboratory for Sustainable Energy, Technicial University of Denmark

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Florida State University Libraries

icap TQ ICP-MS Applications Compendium

Ar Ar + e - INDUCTIVELY+COUPLED+ PLASMA+SPECTROMETRY+ What+is+Plasma?+ FuncDon+of+Plasma+

SmartNotes. What is meant by the term interference?

Techniques for the Analysis of Organic Chemicals by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

Low Level Phosphorus: A Method Comparison Study

Low Level Detection of Priority Inorganic Pollutants in Groundwater By Darren Crichton and Anthony Neumann

Sources of Errors in Trace Element and Speciation Analysis

A Comparison of Arsenic Speciation

Introduction to Elemental Analysis

Supporting Information

Oxygenation Mechanism of Ions in Dynamic Reaction Cell ICP-MS

Hands on mass spectrometry: ICP-MS analysis of enriched 82 Se samples for the LUCIFER experiment

ELEMENTAL ANALYSIS OF GLASS EXAMINATIONS (PART 1) Module 4

Total elemental analysis of food samples for routine and research laboratories using the Thermo Scientific icap RQ ICP-MS

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

Fundamental of collision/reaction cell ICP-MS Katsuhiko KAWABATA

Trace Analysis of Hexavalent Chromium using IC-ICP-DRC-MS

February 20, Joe Cerniglia The International Group for Historic Aircraft Recovery (TIGHAR) Job Number: S0CHG688. Dear Joe:

Partial Energy Level Diagrams

Agilent 8900 Triple Quadrupole ICP-MS LEAVE INTERFERENCES BEHIND WITH MS/MS

EXPANDING THE CAPABILITIES OF ICP-MS. ELAN DRC-e. Uncompromised sensitivity and performance in a robust system designed for routine laboratories

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

Atomic Spectroscopy AA/ICP/ICPMS:

Analytical Methods. Electronic Supplementary Information File

Transcription:

DoD Environmental Data Quality Workshop, St. Louis, MO IMPROVING DATA QUALITY WITH ADVANCED INSTRUMENTATION UTILIZING MULTIPLE INTERFERENCE REDUCTION TECHNOLOGIES Jamie Fox Brooks Applied Labs www.brooksapplied.com

Basics ICP-MS Most accurate and precise analytical instruments for the determination of many trace metals in environmental water samples BUT, instrument sensitivity severely compromised by brine and other elemental and physical interferences

Elemental Interferences Argon (fuel for plasma) combines with numerous elements, forming polyatomic ions Interferences can have the same nominal mass as the analytes of interest Can result in high-biased data and elevated reporting limits

Isobaric Interferences Direct overlap from a different element with an isotope at the same nominal mass (isobars) known as an isobaric interference

Isobaric Interferences The easiest way to avoid a direct isobaric overlap is to choose another (interference free) isotope of the element of interest, if available. For example, 114 Cd is interfered with by the presence of 114 Sn, so 111 Cd, which has no isobaric overlap, can be used. The downside to this is that the detection limit may be degraded due to the low abundance of 111 Cd (12.80%) whereas the 114 Cd isotope is 28.73%. However, the interference has now been removed.

Elemental Interferences

Interference Correction Equations Can be calculated automatically by the ICP-MS software The equation is manually entered though Correction equations increase variability due to propagation of error. They work when the interference is relatively small Subtracting two large numbers from each other usually results in larger bias in the calculated analyte concentration Commercial labs that do not utilize interference reduction technologies still use these equations

Interference Reduction Technologies Dynamic Reaction Cell (DRC) Technology is patented by Perkin Elmer instruments PE ELAN DRCe DRCplus DRCII and Nexion Reactive Gases NH 3, O 2 Collision/Reaction Cell Technology Agilent and Thermo Agilent 7500, 7700, 7900 Thermo icap Q, X series Collision Mode NON-Reactive Gas He (Kinetic Energy Discrimination) Reaction mode H 2 High Resolution ICP-MS Thermo Element 2, NU Attom Separation of Polyatomic Interferences Using Magnetic Sector Field Triple Quad ICP-MS Agilent 8800 NON-Reactive Gases He, Xe Reactive Gases NH 3, O 2, H 2 Controlled Rxn MS/MS Mode All instruments can be run on multiple modes, sequentially

Dynamic Reaction Cell Technology The heart of the DRC is a low constant RF amplitude quadrupole The quadrupole creates a mass bandpass, which is dynamically moved in concert with the analyte mass and whose bandpass width may be adjusted dynamically. When the reaction cell is filled with a reactive gas such as NH 3 and O 2, very efficient removal of certain interferences using reactive gases can be achieved

Dynamic Reaction Cell Technology

Dynamic Reaction Cell Technology Dynamic bandpass is not capable of controlling the reaction chemistry Reaction products in high matrix samples can taint the mass spectrum

Collision Cell Technology (CRC, CCT, KED, etc.) Collision cell technology uses Kinetic Energy Discrimination to separate the polyatomic interferences from analyte ions Interferences are removed based on their physical size, not on a specific reaction with a reaction gas. When a relatively reactive gas such as H 2 is used, the system is considered to be running in reaction mode (CRC) H 2 mode is usually good for a limited number of elements The heart of the system is an octapole (Agilent) after the ion lens

Kinetic Energy Discrimination (KED) Universal Interference Reduction

Mass Spectrum with Matrix

Mass Spectrum with KED Mode Helium

Enhanced Doubly Charged Ratios with KED KED discriminates against ions with lower kinetic energy and the same m/z traversing the cell Ions with higher kinetic energy than the other ions at the same m/z will be preferentially transmitted Doubly-charged ions have double the mass of singly-charged ions at the same m/z and therefore double the kinetic energy, assuming the same velocity. Therefore they are enhanced in He mode. The use of a mathematical correction is the best way to solve the problem If lucky, you can find an analyte mass that does not suffer from a doubly charged interference.

Triple Quadrupole ICP-MS

Triple Quadrupole ICP-MS WHY?? Do We Really Need This? Is This Just a Fancy New Toy? An Excuse to Charge More?

Triple Quadrupole ICP-MS Of Course NOT! Here Is an Example Nd ++ and Sm ++ Collision mode with KED removes polyatomic interferences, but is not effective against doubly-charged interferences As (1ppb)

Triple Quadrupole ICP-MS Reaction Mode in CRC/DRC w/ O 2 Gas

Triple Quadrupole ICP-MS Who needs an ICP-QQQ-MS? Problem Solved! Trace Sr contamination from 100ppm Ca As (as AsO + ) (1ppb) As (1ppb) in: 5% HCl 5% HCl + 100ppm Ca 1ppm Nd/Sm O 2 cell gas reaction mode in Single-Quad mode gives consistent results for As in varied matrices including 1ppm Nd/Sm

Triple Quadrupole ICP-MS Zr is the 18 th most abundant element in earth s crust Sr contamination from 100ppm Ca As (as AsO + ) (1ppb) 0.5ppm Zr As (1ppb) in: 5% HCl 5% HCl + 100ppm Ca 1ppm Nd/Sm 0.5ppm Zr AsO + product ion suffers from Zr + interference on conventional quadrupole ICP-MS. In theory Zr + reacts with O 2 cell gas to form ZrO +, but not complete removal.

Triple Quadrupole ICP-MS Q1 rejects 91 Zr so that it never enters the reaction cell 40 Ar 35 Cl + 40 Ca 35 Cl Nd ++ /Sm ++ 75 As + 91 Zr Reaction gas (O 2 ) 40 Ar 35 Cl +, 40 Ca 35 Cl +, Nd ++ /Sm ++ 75 As 16 O + 91 Zr + Q1 set to m/z 75, so rejects all ions except m/z 75. 91 Zr at mass 91 is rejected 75 As 91 AsO + As + reacts with O 2 cell gas to form AsO + product ion. 40 Ar 35 Cl +, 40 Ca 35 Cl +, Nd ++ /Sm ++ don t react and stay at m/z 75 Q2 set to m/z 91, AsO + product ion mass rejects original on-mass interferences

Triple Quadrupole ICP-MS Q1 rejects 91 Zr so that it never enters the reaction cell With ICP-MS/MS, AsO + product ion is completely free from any overlap. 91 Zr + is rejected by Q1 so doesn t overlap at mass 91 As (as AsO + ) (1ppb) As (1ppb) in: 5% HCl 5% HCl + 100ppm Ca 1ppm Nd/Sm 0.5ppm Zr

The Team at Brooks Applied Labs Special thank you to Russ Gerads, Michelle Briscoe, and Agilent Technologies!