Kestrel 4500 Pocket Weather Tracker

Similar documents
Heat stress index. Dewpoint. pressure. altitude

ea980r Digital Anemometer User Manual

Kestrel 4000 Pocket Weather Tracker

Pocket Weather Meter with Backlight

WM9280. Pro Family weather station with T/H sensor, pluviometer, anemometer, PC connection and Meteotime weather forecasts until 3 days

The Kestrel Handheld Weather Tracker. 1) If the unit is configured to log data and it is turned off, will it continue to log temperature data?

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

Pocket Weather Meter with Backlight

E THERMADATA LOGGER Humidity & temperature recording meter

Mini Environmental Quality Meter

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

473 Dew Point Hygrometer

473-SHX Dew Point Mirror

QUICK START GUIDE Kestrel 5000 Environmental Meter Kestrel 5100 Racing Weather Meter Kestrel 5200 Professional Environmental Meter

473 Dew Point Hygrometer

How to use the MMU-EGS Meteorological field instruments

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Weather Monitoring Station Features Easy Wireless Installation and Solar Power

Automatic titrators, TitroMatic

Vaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance

Wireless Weather Station Instruction Manual

06MAR THU 12: User Manual

Data Sheet / Instructions. Dewpoint MeterO

Humidity Calibration Solutions

Product Description. 1 of 6

USER GUIDE 1000, 2000, 2500 & 2500NV, 3000, 3500 & 3500NV, 3500DT.

Dewpoint Meter Data Sheet / Instructions

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

ebro has expanded its range of measuring instruments in the food area even further: ebro Data Logger Family EBI 20

Complete Moisture Analysis

National Event Tree. **Combo Package** Eliminator 2000 Super & National Event Tree. Item # 3152 $849

Operating Instructions 5 Day Weather Station with Color Screen Model: DG-TH8805 INDOOR UNIT

Overview Brochure Comprehensive range of instrumentation for the measurement of moisture and oxygen

Humidity Calibration Solutions

CABLE FREE WEATHER STATION

User manual Handbediening Mode d emploi Modalità d uso Bedienungsanleitung

AWOS. Automated Weather Observing Systems COASTAL

GPS Scout Backtrack Altimeter Model: GP123 USER MANUAL

WEATHER MULTI-SENSOR. Vaisala Weather Transmitter WXT510. Change the Way You Measure Weather

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

Meteorological Service

Acceleration/Velocity/Displacement VIBRATION METER

Thermal anemometer. We measure it. testo 405. Flow velocity measuring instrument with temperature measurement

Vantage Vue Weather Station

Vantage PRO2 Quick. Reference Guide

Assembly and Operation Manual. April 2016

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Innovative Sustainable Technology

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

Section 7: Hazard Avoidance

Manual Weather Stations & Instruments

SENSORS CLIMATRONICS CORPORATION (631) MANUAL TACMET II WEATHER STATION, EMI 2.0 INSTALLATION 1.0 INTRODUCTION

CABLE FREE TM WEATHER STATION

1551A Ex/1552A Ex Intrinsically Safe Stik Thermometer. The new gold standard of industrial temperature calibration

Performance Measurements for Mechanical Air Handling Systems

Non-Acoustical Inputs

Quick Reference Guide

INSTRUCTION MANUAL for No. 45 Altimeter-Compass

Designed to go where you work

Edgetech Instruments Inc.

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

Complete Moisture Analysis

2100TR Liquid Scintillation Counter

Understanding uncertainties associated with the 5128A RHapid-Cal Humidity Generator

Chilled Mirror Hygrometry

TM360 TEMP-SEEKER PRECISION THERMO-PSYCHROMETER OPERATION MANUAL

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

Dual laser + type K thermometer INFRARED THERMOMETER

What is the maximum distance I can have the remote sensors from the display?

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

WEATHER STATION FOR SOLAR FARM MONITORING

NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

SOFTWARE USER MANUAL. Weather Capture Advance WS1640 WM9280

Cabled Vantage Pro2 & Vantage Pro2 Plus Stations

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

Instruction Manual. HI Refractometer for Sucrose in Wine and Grape Products Measurements

Today s Weather 24 Hour Forecaster

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

VIBRATION METER. Instruction Manual.

MxVision WeatherSentry Web Services Content Guide

WeatherHawk Weather Station Protocol

THE MEASUREMENT OF SOLAR ULTRAVIOLET SPECTRAL IRRADIANCE PROBLEMS & SOLUTIONS

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

3. Analytical measurement and testing Timing/Clocks-Climate measurement/hygrometer

Understanding the uncertainties associated with using the 5128A RHapid Cal portable humidity generator

The Fundamentals of Moisture Calibration

IMPORTANT. Questions? Contact Customer Support at (877) or visit Display for 5-in-1 Weather Sensor model 06016RM

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

2 ACCESSING VARIOUS MODES

Suunto X6 watch. Suunto X6 watch. James. - Very old articles - Copyright (c) Outdoors-Magazine.com under a Creative Commons

Atmosphere Properties and Instruments. Outline. AT351 Lab 2 January 30th, 2008

ED 701 General Industry Pressure Transmitter

Techniques for Fast Measurements of Low Dewpoint in Portable Hygrometers

MICHELL TECHNOLOGIES FOR MOISTURE. Calibration. General Principles & Theory, Equipment Considerations

Professional Weather. For Emergency. Professional. For. Emergency. Weather Stations. Stations. Responders. Professional Weather Stations.

Transcription:

Kestrel 4500 Pocket Weather Tracker For years our customers have been asking for wind direction along with wind speed. New for 2007, the Kestrel 4500 does just that with its built in digital compass. But it doesn t stop there. It also calculates crosswind and headwind/tailwind with reference to a user-set target heading, and stores the information along with all the other environmental readings in its 1400 data point memory. Pair the 4500 Wind Meter with the Kestrel Vane Mount and you have a datalogging weather station that sets up in seconds and rotates in the slightest of breezes. Did we mention that the whole kit is the ultimate in portability? It packs down into a 2 x 6 inch pouch and weighs under 8 ounces. Military personnel and pilots flying in darkness are often concerned with preserving their night vision. Due to overwhelming demand from our military customers, the Kestrel NV line was added in 2005. The Kestrel 4500NV has a night-vision preserving backlight which helps users to sustain natural night vision. The NV's backlight incorporates an optical filter to reduce overall brightness and minimize blue and green spectrum light to preserve night vision. Additionally, NV backlights are also much dimmer than a standard backlight, making it more difficult to detect with the naked eye in night operations. This backlight appears soft greyish pink, not red, and is still in the visible spectrum, so is not compatible with night-vision equipment.

It takes 30 to 45 minutes for the average eye to adapt to darkness and maximize night vision. Even a short burst of white, yellow, green or blue light bleaches out the rod cell photoreceptors in the eye and causes night blindness until the entire adaptation process can take place again. Light in the red spectrum does not cause this bleaching out, preventing night blindness and night vision fatigue. Measurement Response Time Units Operational Range Resolution Accuracy (+/-) Specification Range Wind Speed 0.4 to 60.0 59 to 11,948 1.0 to 218.0 0.8 to 135.0 knots 0.6 to 118.3 kt 0.1 Larger of 3% of reading or 0.4 to 40.0 least significant 1 digit 59 to 7877 0.1 1.0 to 144.0 1 0.8 to 89.0 0.1 0.6 to 78.0 kt Beaufort 0 to 12 B 0.1 0 to 12 B 1 inch diameter impeller with precision axle and sapphire bearings. Off-axis accuracy -1% @ 5º off-axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH / 7. Sustained operation above 60 MPH / 27 will wear impeller rapidly and may cause destruction of impeller. Replacement impeller (NK PN-0801) may be field-installed without tools (US Patent 5,783,753). Wind Direction / Forward Heading 360 1 5 0 to 360 Cardinal Points 360 16 Points 5 0 to 360 2-axis solid-state magnetoresistive sensor mounted perpendicular to unit plane to permit operation while measuring wind speed. Declination/variation adjustable for True North readout. Accuracy of measurements dependent upon unit's vertical position. Selfcalibration routine eliminates magnetic error from batteries or unit and must be run after every full power-down (battery removal or change). F -49.0 to 257.0 F 0.1 1.8 F -20.0 to 158.0 F

C -45.0 to 125.0 C 0.1 1.0 C -29.0 to 70.0 C Measures air, water and snow temperature. Thermally isolated, hermetically sealed, precision thermistor mounted externally (US Patent 5,939,645). Calibration drift negligible. Relative Humidity %RH % 0.1 3.0 %RH 5.0 to 95.0 % noncondensing Polymer capacitive humidity sensor mounted in thin-walled chamber external to case for rapid, accurate response (US Patent 6,257,074). (To achieve stated relative humidity accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and must be kept out of direct sunlight.) Calibration drift +/- 2% over 24 months. Relative humidity may be recalibrated at factory or in field using Kestrel Humidity Calibration Kit (NK PN-0802). Pressure (mb & PSI 4000 model only) 0.3 to 32.5 hpa / mb 10.0 to 1100.0 hpa / mb PSI 0.15 to 16.0 PSI 0.01 0.05 At 77.0 F, 22.1 to 32.5 0.1 1.5 hpa / mb At 25.0 C, 750 to 1100 hpa / mb 0.01 0.02 PSI At 77.0 F, 10.9 to 16.0 PSI Monolithic silicon piezoresistive pressure sensor with second-order temperature correction. Maximum error over temperature range 32 to 158 F (0 to 70 C), +/- 0.06 / +/-2.0 hpa. Calibration drift typically -0.03 / -1.0 hpa per year. Pressure sensor may be recalibrated at factory or in field. Altitude ft -6000 to 30000 ft 1 50 ft At 77.0 F, <19,700 ft. Max error +/- 98 ft m -2000 to 9000 m 1 15 m At 25.0 C, <6,000 m. Max error +/- 30 m compensated pressure (barometric) altimeter. Crosswind 0.8 to 135.0 1 5% 8.5 to 89.0

Headwind, Tailwind 59 to 11,880 1.0 to 217.3 0.4 to 60.0 knots 0.6 to 117.3 kt 1 5% 750 to 7832 0.1 5% 13.7 to 143.2 0.1 5% 3.8 to 40.0 0.1 5% 7.4 to 77.0 kt Calculated from the primary measurements of wind speed, wind direction and target heading. Auto-switching headwind/tailwind indication. Ranges expressed refer to primarywind speed. Wind Chill F 0.7 to 135.0 MPH, -49.0 to 257.0 F C 0.4 to 60.0, -45.0 to 125.0 C 0.1 1.8 F 1.8 to 89.0, -50.0 to 50.0 F 0.1 1.0 C 0.4 to 40, -45.6 to 10.0 C Calculated from the primary measurements of wind speed and temperature. Utilizes the NWS Wind Chill (WCT) Index, revised 2001, with wind speed adjusted by a factor of 1.5 to yield equivalent results to wind speed measured at 10 m above ground. (Specification temperature limits established by WCT Tables.) Heat Index F %RH, -49.0 to 257.0 F C %RH, -45.0 to 125.0 C 0.1 3.6 F 70.0 to 130.0 F, 0 to 100% RH 0.1 2.0 C 21.1 to 54.4 C, 0 to 100 %RH Calculated from the primary measurements of temperature and relative humidity. Utilizes the NWS Heat Index (HI) tables. (Specification temperature limits established by HI tables.) Dewpoint F %RH, -49.0 to 257.0 F C %RH, -45.0 0.1 3.6 F -20.0 to 158.0 F, 20.0 to 95.0% RH 0.1 2.0 C -29.0 to 70.0 C, 20.0 to

to 125.0 C 95.0 %RH Calculated from the primary measurements of temperature and relative humidity. to which the air would need to be cooled at a constant pressure to become saturated. Wet Bulb F -49.0 to 257.0 F, %RH, 8.86 to 32.48 C -45.0 to 125.0 C, %RH, 300.0 to 1100.0 hpa 0.1 3.6 F 32.0 to 100.0 F, 5.0 to 95.0% RH, 8.86 to 32.48, <19700 ft 0.1 2.0 C 0.0 to 37.8 C, 5.0 to 95.0 %RH, - 2000.0 to 9000.0 hpa, <6000 m Calculated from the primary measurements of temperature, relative humidity and pressure. indicated by a wet bulb psychrometer. Density Altitude ft -49.0 to 257.0 F, % RH, 8.86 to 32.48 1 246 32.0 to 100.0 F, 5.0 to 95.0 %RH, 8.86 to 32.48, <19700 ft m -45.0 to 125.0 C, %RH, 300.0 to 1100.0 hpa 1 75 0.0-37.8 C, 5.0 to 95.0 %RH, -2000 to 9000 hpa, <6000 m Calculated from the primary measurements of temperature, relative humidity and pressure. Air density converted to equivalent sea level elevation at the International Standard Atmosphere. Max/Avg Wind Speed (Air Velocity), Crosswind, Headwind/Tailwind One-button clear and restart of Max Wind Gust and Average Wind measurement. Data Storage / Display Minimum, maximum, average and logged history stored and displayed for every measured value. 1400-point data logger with graphical display. Auto data storage; interval settable from 2 seconds

to 12 hours. Manual data capture. Data Upload Display Display Update Display Backlight Clock / Calendar Operational Range (LCD and Batteries) Storage Auto Shutdown Languages Certifications Requires optional PC interface (NK PN-0830) and provided software. RS-232 connection with USB adapter available. Multifunction, multi-digit programmable dot-matrix display.. Choice of aviation green or visible red electroluminescent backlight. Automatic or manual activation. Real-time hours:minutes:seconds clock, calendar, automatic leapyear adjustment. The operational temperature range of the liquid crystal display and batteries is 14 F to 131 F / -10 C to 55 C. Beyond the limits of the operational temperature range, the unit must be maintained within range and exposed for minimum time necessary to take reading. -22 F to 140 F / -30 C to 60 C. User-selectable: 15 or 60 minutes with no key presses or disabled. English, French, German, Italian, Spanish. CE certified. Individually tested to NIST-traceable standards (written certificate of tests available at additional charge). Batteries AAA Alkaline, two, included. Average life, 400 hours of use, +/- depending on backlight use. Environmental Dimensions Waterproof (IP67 standard). Drop-tested (MIL.STD.810F; unit only. Substantial impact may damage replaceable impeller.). Unit 5.0 x 1.8 x 1.1 in / 12.7 x 4.5 x 2.8 cm. Weight Unit 3.6 oz / 102 g. Kestrel Meters are designed and manufactured at NK s facility in Boothwyn, Pennsylvania, and are individually calibrated at the time of manufacture. Every Kestrel Meter comes with a Certificate of Conformity to document the unit s accuracy all Kestrel measurements are traceable to the National Institute of Standards and Technology, ensuring the highest level of reliability. Additional NIST Calibration and Certification services are available.