ICE MANTLE MAKER MODEL 452 User Maintenance Manual/Handbook

Similar documents
ICE MANTLE MAKER MODEL 452 User Maintenance Manual/Handbook

SIMPLE LIQUID NITROGEN COMPARATOR MODEL 461 User Maintenance Manual/Handbook

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

P E R O X Y G E N S A sector group of Cefic

Compact Orifice FlowMeter

SAFETY TRAINING LEAFLET 08 ACETYLENE, CALCIUM CARBIDE, LIME SLUDGE AND PURIFYING MATERIALS

DRAIN TRACING DYE RED E123

Oxygen Demand, Chemical

MSDS. ( Material Safety Data Sheet ) High Density Polyethylene (LUTENE-H ME9180)

Lab Safety Rules GENERAL GUIDELINES. 1. Conduct yourself in a responsible manner at all times in the laboratory.

AM 500A 500 WATT AM 1A 1 KILOWATT AM BROADCAST TRANSMITTERS. October, 1999 IM No

Chemistry Lab Safety

Preparation of an Ester Acetylsalicylic Acid (Aspirin)

Chapter 1, Lesson 3: The Ups and Downs of Thermometers

Ambient Weather WS-152B 6" Contemporary Barometer User Manual

Superconductivity. Never store liquid nitrogen in a container with a tight fitting lid.

Today s Weather 24 Hour Forecaster

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

Oxygen Demand, Chemical

Heat Lost and Heat Gained Determining the Specific Heat of a Metal

STATES OF MATTER INTRODUCTION

Schools Analyst Competition

2.8-1 SCIENCE EXPERIMENTS ON FILE Revised Edition. Dew Formation

26. The preparation and purification of N-phenylethanamide Student Sheet

Facilities Management

Safety in the Chemistry Laboratory

METHOD 7B - DETERMINATION OF NITROGEN OXIDE EMISSIONS FROM STATIONARY SOURCES (ULTRAVIOLET SPECTROPHOTOMETRIC METHOD)

Objective: Science Classroom Laboratory Safety

Name: Period: Date: UNIT 0: Introduction to Chemistry Lecture 2: Success in Lab!

GUIDELINES FOR THE SAFE USE OF PYROPHORIC LIQUID REAGENTS

TPH (Total Petroleum Hydrocarbons)

General Accreditation Guidance. Liquid-in-glass thermometers selection, use and calibration

General Rules. Be alert and responsible at all times in the laboratory.

Evaluation copy. The Molar Mass of a Volatile Liquid. computer OBJECTIVES MATERIALS

Substances and Mixtures:Separating a Mixture into Its Components

The Molecular Weight of Carbon Dioxide

Bisphenol A ELISA Kit

GCE Chemistry PSA12: A2 Inorganic Chemistry Prepare an inorganic complex

1. The Supervisor and/or the Section Safety Officer must be notified of all accidents and injuries which may occur within the section.

N) manual. Biomaster Operating manual

FerroZine Method 1 Method to 100 µg/l Fe (10-cm cell) Reagent Solution. Instrument Adapter Sample cell DR 6000 LZV

symphony Reference Electrodes

Key points. Discuss why contact lenses are not allowed in the chemical laboratory. Short pants Skirt Scandals Open-toed shoes

States of Matter: Solid, Liquid, and Gas

The Water Triple Point - A Reference Cell Close to the ITS-90 Value

Newton s Second Law of Motion

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

Experiment 2: THE DENSITY OF A SOLID UNKNOWN AND CALIBRATION WITH DATASTUDIO SOFTWARE

Periodicity of Properties of Oxides

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA

STANDARD OPERATING PROCEDURES

PYRIPROXYFEN TECHNICAL

THE UNIVERSITY OF NEWCASTLE- DISCIPLINE OF MEDICAL BIOCHEMISTRY. STANDARD OPERATING PROCEDURE PROCEDURE NO: GLP 021 MOD: 1st Issue Page: 1 of 6

Science Safety Booklet

Citric Acid Analysis L-6-1. MOISTURE (Karl Fischer)

PART I: MEASURING MASS

CHEMISTRY 135 General Chemistry II. Energy of Phase Changes [1]

HHPS WHMIS. Rules MSDS Hazard Codes Systems. Biology based. Chemistry based. Safety Symbols. Safety in the Lab. Lab Equipment

CHEMISTRY 135. Kinetics: Iodination of Acetone

CHEMICAL SAFETY TRAINING LEADER GUIDE. Chemical Safety Training Leader Workbook 1

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT

Tornado Preparedness. Monthly Safety Meeting

Chapter 2, Lesson 5: Changing State Melting

PRODUCT SAFETY SUMMARY (GPS) SODIUM-HYDROXIDE

Ideal Gas Law. To demonstrate the dependence of pressure on temperature for a fixed volume of real gas.

Installation guide 862 MIT / MIR

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

2. Synthesis of Aspirin

Physical and Chemical Properties of Matter Lab

ASTM Designation: D Standard Test Method for Determination of Iodine Number of Activated Carbon

Dimethyl ether (DME) for fuels Determination of impurities Gas chromatographic method

Hands-On Science. Light & Color. W. Michael Margolin Illustrated by Lloyd Birmingham

INSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7

Corn Sugar (crude & refined) Analysis F MOISTURE (Karl Fischer)

To use calorimetry results to calculate the specific heat of an unknown metal. To determine heat of reaction ( H) from calorimetry measurements.

Fischer Instruments Stainless Steel Barometer User Manual

Voltaic Cells. 100 ml graduated cylinder Emery cloth 150 ml beakers, 3 Salt bridge Voltmeter Wires with alligator clips, 2

technical guide Working Thermometers Calibration Procedures

OHD L-14 METHOD OF TEST FOR DETERMINING THE SPECIFIC GRAVITY AND UNIT WEIGHT OF COMPACTED BITUMINOUS MIXTURES

IBIDEN Group Green Procurement Guidelines. (Version 6)

2010 Winter Weather Advisory

Ambient Weather DHR70B-BRASS Handheld Fishing Barometer User Manual

Safe Use of Pyrophoric/Water Reactive Materials

13.4. Lesson 13.4 Changes of State. Overview

Electrolysis SCIENCE TOPICS PROCESS SKILLS VOCABULARY

Fischer 1508BTH-45 5" Brass Barometer with Temperature & Humidity User Manual

You must bring 1-2 empty pop cans to lab this week.

The Energy of Phase Changes

Nanoparticle Safety Program

Fischer Banjo Weather Station with Thermometer, Hygrometer, Barometer User Manual

Chemical Storage Guide

HAZARD COMMUNICATION SAFETY PROGRAM

Freezing point depression (Item No.: P )

Pre-Lab Read the entire laboratory assignment. Answer all pre-lab questions before beginning the lab.

Enzyme Catalysis. Objectives

Scope and application: For water, wastewater and seawater. Distillation is required for wastewater and seawater.

Fischer Instruments Chrome and Black Wood Base Weather Station with Barometer, Hygrometer, Thermometer and Quartz Clock User Manual

Adenosine Deaminase Assay (ADA) Kit Instructions

C. Eugene Bennett Department of Chemistry

Advanced Unit 7: Chemistry Practical Examination (SET A) Candidates must have: Scientific calculator Ruler

Transcription:

ICE MANTLE MAKER MODEL 452 User Maintenance Manual/Handbook Isothermal Technology Limited, Pine Grove, Southport, PR9 9AG, England Tel: +44 (0)1704 543830 Fax: +44 (0)1704 544799 Internet: www.isotech.co.uk E-mail: info@isotech.co.uk The company is always willing to give technical advice and assistance where appropriate. Equally, because of the programme of continual development and improvement we reserve the right to amend or alter characteristics and design without prior notice. This publication is for information only. Page 1 of 10

CONTENTS GUARANTEE... 3 CAUTIONARY NOTE... 4 HEALTH AND SAFETY INSTRUCTIONS... 5 PROCEDURE FOR THE CONSTRUCTION OF A WATER TRIPLE POINT CELL MANTLE USING A HEAT PIPE... 6 SCOPE... 6 EQUIPMENT... 6 PREFERRED METHOD USING LIQUID NITROGEN... 7 PREPARATION OF THE CELL... 7 FORMATION OF ICE USING THE MANTLE-MAKER... 7 ICE BRIDGE... 8 ALTERNATIVE METHOD USING SOLID CARBON DIOXIDE... 9 INITIATING THE FREEZE INSIDE THE WATER TRIPLE POINT CELL... 9 CELL USE... 9 Page 2 of 10

GUARANTEE This instrument has been manufactured to exacting standards and is guaranteed for twelve months against electrical break-down or mechanical failure caused through defective material or workmanship, provided the failure is not the result of misuse. In the event of failure covered by this guarantee, the instrument must be returned, carriage paid, to the supplier for examination and will be replaced or repaired at our option. FRAGILE CERAMIC AND/OR GLASS PARTS ARE NOT COVERED BY THIS GUARANTEE INTERFERENCE WITH OR FAILURE TO PROPERLY MAINTAIN THIS INSTRUMENT MAY INVALIDATE THIS GUARANTEE RECOMMENDATION The life of your ISOTECH Instrument will be prolonged if regular maintenance and cleaning to remove general dust and debris is carried out. ISOTHERMAL TECHNOLOGY LTD. PINE GROVE, SOUTHPORT PR9 9AG, ENGLAND TEL: +44 (0) 1704 543830/544611 FAX: +44 (0)1704) 544799 The company is always willing to give technical advice and assistance where appropriate. Equally, because of the programme of continual development and improvement we reserve the right to amend or alter characteristics and design without prior notice. This publication is for information only. Page 3 of 10

CAUTIONARY NOTE ISOTECH PRODUCTS ARE INTENDED FOR USE BY TECHNICALLY TRAINED AND COMPETENT PERSONNEL FAMILIAR WITH GOOD MEASUREMENT PRACTICES. IT IS EXPECTED THAT PERSONNEL USING THIS EQUIPMENT WILL BE COMPETENT WITH THE MANAGEMENT OF APPARATUS WHICH MAY BE POWERED OR UNDER EXTREMES OF TEMPERATURE, AND ARE ABLE TO APPRECIATE THE HAZARDS WHICH MAY BE ASSOCIATED WITH, AND THE PRECAUTIONS TO BE TAKEN WITH, SUCH EQUIPMENT. Page 4 of 10

HEALTH AND SAFETY INSTRUCTIONS 1. Read this entire handbook before use. 2. Wear appropriate protective clothing. 3. Operators of this equipment should be adequately trained in the handling of hot and cold items and liquids. 4. Do not use the apparatus for jobs other than those for which it was designed. 5. Do not handle the apparatus when it is cold, unless wearing the appropriate protective clothing and having the necessary training. 6. Do not drill, modify or otherwise change the shape of the apparatus. 7. Do not dismantle the apparatus. 8. Do not use the apparatus outside its recommended temperature range. 9. There are no user serviceable parts inside. Contact your nearest Isotech agent for repair. 10. Ensure adequate ventilation when using liquid nitrogen, solid carbon dioxide and alcohols. 11. Ensure Dewar flasks used with liquid nitrogen and solid carbon dioxide have been specifically intended and manufactured for this purpose. Page 5 of 10

PROCEDURE FOR THE CONSTRUCTION OF A WATER TRIPLE POINT CELL MANTLE USING A HEAT PIPE SCOPE This procedure describes the creation of Water Triple Point Cell Ice Mantles using the Isotech Ice Mantle Maker Model 452. The Ice Mantle Maker comprises a heat pipe of special construction designed to be especially efficient when used vertically. Diagram 1 shows the dimensions of the Ice Mantle Maker. EQUIPMENT With the Ice Mantle Maker the following items help to produce and control the shape of the Ice Mantle:- A syringe with a fine tube or needle attached of sufficient length to reach the bottom of the water triple point s reentrant tube. An Aluminium collar specific to the cell outside diameter and of length to cover the water/vapour interface. Alcohol (Methanol or Acetone) A supply of liquid nitrogen (or solid Carbon Dioxide, if used). A small Thermos or Dewar flask (suitable for use with Solid CO 2 or Liquid Nitrogen)*on no account should Liquid Nitrogen be poured into an ordinary Thermos Flask. The cell itself should be pre-cooled to about 0 C, in for example a Dewar flask containing crushed ice. The cell should remain in this Dewar during production of the ice mantle, but removed occasionally to check the progress of the mantle. Page 6 of 10

PREFERRED METHOD USING LIQUID NITROGEN PREPARATION OF THE CELL 1. The cell is first pre-cooled and maintained at 0 C (see above). 2. Any water which may have collected in the re-entrant tube is evacuated using the syringe and attached tube. 3. Alcohol is introduced into the re-entrant tube so that is approximately ¾ full, using the syringe to flush the alcohol over all surfaces of the re-entrant tube so as to eliminate any remaining water. 4. Next a metal rod pre-cooled in liquid nitrogen is introduced into the re-entrant tube of the Water Triple Point Cell. This initiates the formation of ice around the re-entrant tube prior to use of the Mantle Maker. If no ice has seen to have formed replace the first rod with another rod pre-cooled in liquid nitrogen, until ice has been seen to have formed. FORMATION OF ICE USING THE MANTLE-MAKER Once ice has been seen to have formed around the re-entrant tube, the metal rod is removed and the Mantle Maker placed fully into the cell s re-entrant tube. Liquid nitrogen is now poured carefully into the metal container of the Mantle Maker apparatus; taking care not to splash any since it can burn skin. The level of alcohol in the re-entrant tube of the cell should be adjusted if necessary to be level with the top of the water in the cell. All that is required now is to occasionally top up the liquid nitrogen level in the Mantle Maker, check for ice bridge formation (see note below) at the surface of the water in the cell and eventually, the final thickness of the mantle formed (which should not extend to the outer wall of the cell, as this can rupture the glass). The ice mantle will be complete in approximately 20 minutes dependent on the size of the cell. In any case the mantle should be approximately ¾ of the distance from the re-entrant tube to the outer glass wall of the cell, in thickness, but more. It may be necessary to gently tip the cell to one side to check the thickness of the mantle since the magnifying effect of the glass and water can make it appear larger than it actually is. Page 7 of 10

ICE BRIDGE By nature of water, ice preferentially forms at its surface. Ice in a Water Triple Point Cell forms a bridge between the re-entrant tube and the Cell s outer wall. This is natural, but can eventually crack the glass wall of the cell. There are various ways to melt this Ice Bridge, with your hand, by holding the cell at the point where the Ice Bridge forms until it melts or more conveniently by sliding a warm object or sleeve over the cell. This we provide in the form of an Aluminium Collar that you can re-warm in warm water. Page 8 of 10

ALTERNATIVE METHOD USING SOLID CARBON DIOXIDE Take a small Thermos or Dewar flask half fill it with alcohol and add solid Carbon Dioxide (dry ice) until the alcohol has cooled to the Carbon Dioxide temperature i.e. pieces of CO 2 remain in the flask. Transfer sufficient cooled alcohol from the flask to fill the Ice Mantle Maker to within 10mm of its metal container s rim. INITIATING THE FREEZE INSIDE THE WATER TRIPLE POINT CELL Pour about 1 cc of pre-cooled alcohol into the Water Triple Point Cell s re-entrant tube. Place the Ice Mantle Maker fully into the re-entrant tube. Ice will begin to form around the bottom of the Water Triple Point Cell s re-entrant tube. More pre-cooled alcohol can be added to form even heat transfer from the Mantle Maker and create a uniform Ice Mantle. The alcohol in the top container of the Ice Mantle Maker should be approximately -75 C to begin with. Very quickly as heat is exchanged with the ice in the cell, the alcohol will begin to warm. To prevent this continue to add solid CO 2. The Ice Mantle will be complete in 20 to 30 minutes. As before, any formation of an ice bridge should be dealt with as described previously. CELL USE Once made the water triple point cell should be maintained at 0 C for at least 2 hours prior to use but preferably overnight. The alcohol in the re-entrant tube should be removed and replaced with water. A metal rod at ambient temperature placed carefully into the re-entrant tube of the cell will free the ice-mantle ready for use. Page 9 of 10

Page 10 of 10