GW Professional Weighing Scale. User Manual SNOWREX INTERNATIONAL CO., LTD. SRGW

Similar documents
AW/AHW Professional Weighing Scale. User Manual

Bright Advance Corporation

244241, Operation Manual Contents subject to change without notice. Version 1.0 Issue AA

OP-02 / OP-03 / OP-04

Operation Manual Contents subject to change without notice

Acceleration/Velocity/Displacement VIBRATION METER

Dual laser + type K thermometer INFRARED THERMOMETER

PS R975B 12R976B 12R977B 12R978B 12R979B

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!"#$%&'()*%!+#,&-('.!!!!!!

MS Operation Manual

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

Property of Monitronics Inc

Digital Torque Meter ADT-C Series OPERATION MANUAL

NV-DVR09NET NV-DVR016NET

ea980r Digital Anemometer User Manual

PAX2S Modbus Register Table REVISED 2/20/12 LP0894A

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

PiCUS Calliper Version 3

TitraLab 580 and 585. KF Titration Workstations. Reference Manual D21T083

Jasco V-670 absorption spectrometer

An ultra-sensitive, versatile, and affordable single tube luminometer for Life Science Research.

Vetek Weighing AB JWL Service Manual. Service Manual. May not be reproduced in any form without written permission PAGE 0

MULTIFUNCTION COMPUTER METER CX-742 USERS MANUAL

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

WEIGHT INDICATOR WIDRA W90

SuperCELL Data Programmer and ACTiSys IR Programmer User s Guide

INSTRUCTION MANUAL Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements

User's Guide. DISTO online. Leica Geosystems

zulu - inca - kundalini - cozmo Welcome to the Ownership of a YES Watch.

Instruction Manual HI Refractometer for Sodium Chloride Measurements

Minimum (-31) every 10 s -35 (-31)

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

Service Manual for DS-781/782(RS)

Instruction Manual. HI Refractometer for Sucrose in Wine and Grape Products Measurements

610,- KERN ADB. Analytical balances. Quick-Finder Analytical balances. Large glass draught shield with 3 sliding doors


MP3 Digital Voice Module Model No.: VCM-SD Rev.A3. Content

Operation Manual for DC-788

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

Operating instruction Platform scale

RADIATION-METER TM-91/TM-92

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

TitraLab 854 and 856. ph-stat Titration Workstations. Reference Manual D21T054

OPERATING INSTRUCTIONS

Instruction Manual HI Refractometer for Sucrose in Wine and Grape Products Measurements

INSTRUCTION MANUAL Milwaukee Refractometer MA872 Refractometer for Fructose Measurements

Bante210 Benchtop ph Meter Instruction Manual

Operating Instructions 5 Day Weather Station with Color Screen Model: DG-TH8805 INDOOR UNIT

VELA. Getting started with the VELA Versatile Laboratory Aid. Paul Vernon

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

VIBRATION METER. Instruction Manual.

MPP5800 series - PANEL MOUNT PRINTERS. Options

TitraLab 870. Reference Manual. ph/ep/ip/ec/ise Titration Workstation D21T060

PC User s manual. Advanced Electronic/Air Column PC BOWERS METROLOGY page 1 /32 version E

QUANTUM CONCEPT. Swimming User s Manual

Connect the Vernier spectrometer to your lap top computer and power the spectrometer if necessary. Start LoggerPro on your computer.

ISSP User Guide CY3207ISSP. Revision C

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

Consists of several displays that provide you with useful information. Odometer, Trip meter. distribution monitor. Bluetooth HandsFreeLink

INSTRUCTION MANUAL Milwaukee Refractometer MA888 Refractometer for Ethylene Glycol Measurements

CZ-53X Series IR Night Vision

Instructor s Advance Preparation

MAN-SGY-012-V11 EC 5195 Fairford Electronics Ltd - Synergy Modbus RTU Programming Manual - 22nd February 2016 Page 1 of 59.

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

473-SHX Dew Point Mirror

InfraRed Thermometer with Laser Pointer

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

January 2002 INSTRUMENT MANUAL 1470 WIZARD. Gamma Counter

INFRARED THERMOMETER TM0819

2100TR Liquid Scintillation Counter

After publication, this Indian Standard will supersede the following Indian Standards:

Mini Environmental Quality Meter

ION570. Reference Manual. Ion Analyser D21M073

Automatic Watershed Delineation using ArcSWAT/Arc GIS

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

PAA-ANALYZERS PRINCIPLE OF OPERATION

GT-510/510L series Instruction Manual

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

MODBUS Protocol for CS141 network card families

INSTRUCTIONS. Go-To Maksutov-Cassegrain. 90mm (3.6 ) F f/13.8

GPS Scout Backtrack Altimeter Model: GP123 USER MANUAL

Hooke s Law. Equipment. Introduction and Theory

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

Experiment P30: Centripetal Force on a Pendulum (Force Sensor, Photogate)

FAQS. La Crosse Technology, Ltd. Page 1

Measure - Conductivity STANDARD Last std: Sep 10:17 am. Touch meas to measure sample. Touch std to access standardize mode ATC. 25.

Digital Controller Operation

CHV Series Vector Control Inverter Options. Operating Instructions for Tension Control Card

Dewpoint Meter Data Sheet / Instructions

Circular Motion and Centripetal Force

Creating Empirical Calibrations

Speedtech Deerhunter s EDGE TM Model HE-1. Speedtech ECO EDGE TM Model EE-1. User s Manual

Conservation of Mechanical Energy Activity Purpose

HD32.2 WBGT Index HD 32.2 INSTRUMENT FOR THE ANALYSIS OF THE WBGT INDEX

SC400 Colorimeter. Silica. Photometer-System. Instruction Manual. SiO 2. Bedienungsanleitung Seite Instruction Manual Page 19 33

Transcription:

GW Professional Weighing Scale User Manual SNOWREX INTERNATIONAL CO., LTD. SRGW 20100415

Table of Contents Table of Contents...1 Specifications... 2 Basic specification... 2 Series specification(ec TYPE/OIML APPROVED)... 2 Series specification(non-approved)... 2 Display and keypad... 3 LCD Display... 3 Keypad... 4 Using the weighing scale... 6 Counting function... 6 Percentage function... 6 Operation of M+... 6 Operation of MR... 6 Alarm function... 7 Settings and Calibration... 8 General Settings (CAL 1)... 8 Print Settings (CAL 2)... 9 Calibration Procedure (CAL 3)...11 Linearity Calibration Procedure (CAL 4)... 12 RS232C Connection: DB-09 (Male)... 13 Bi-directional RS232C Setting... 13 1

Specifications Basic specification Display Digit Pan Size(mm) Dimensions(mm) Net Weight(kg) Operating Temperature Relative Humidity Power Interface LCD, height 17mm, 6/6(Parameter/WEIGHT) 280 x 200 (WxL) 280x300x110(WxLxH) 3.6kg 0 C to +40 C Less than 85% DC9V / 500mA, AC adapter; Built in 6V Rechargeable Battery RS-232C (optional) Series specification(ec TYPE/OIML APPROVED) Model GW-6D GW-15D GW-30D Max 1 / Max 2 = 3kg / 6kg 6kg / 15kg 15kg / 30kg Min 1 / Min 2 = 20g / 3kg 40g / 6kg 100g / 15kg e 1 / e 2 = 1g / 2g 2g / 5g 5g / 10g Accuracy 1/3000(Dual) 1/3000(Dual) 1/3000(Dual) Series specification(non-approved) Model GW-3H GW-6H GW-15H GW-30H Max. Capacity 3kg 6kg 15kg 30kg d = 0.1g 0.2g 0.5g 1g Accuracy 1/30000 1/30000 1/30000 1/30000 2

Display and keypad LCD Display. Numerical display to display weight, ID number Indicates the weight is stable. Indicates the weight is at zero. MR Indicates the total weights in memory M+ Indicates the accumulation weights in memory. G.W When is shown above the G.W. indicator, the Gross Weight is displayed. NET When is shown above the NET. indicator, the Net Weight is displayed. T.W When is shown above the T.W. indicator, the Tare Weight is displayed. Hi When the weight is over the weight upper bound, is flashing next to the Hi indicator. Go When the weight is between the weight upper bound and lower bound, is flashing next to the Go indicator. Lo When the weight is under the weight lower bound, is flashing next to the Lo indicator. kg & lb is shown above the is shown above the Indicate the unit of weight when in counting mode. when in percentage mode. 3

Keypad Key Icons Keypad Descriptions Zero key Press to absorb trivial weight on the pan and set the scale to zero. Tare key Press to perform tare operation. & Number setting keys Clear key Press +1 key to increase number and press shift to shift the digit. Press to clear the input data. M+ key Press to accumulate piece counting and weighing results. MR key Press to recall total number of accumulation and total weighing. Alarm key Press to set alarm for weight upper and lower bound. Backlight key Press to set backlight on or off. Function key Sampling key Percentage key Print key Press to toggle among weighing, percentage and counting modes. Press to set up sample quantity. Press to set up percentage of the given sample. Press to print the weight data. 4

Unit key ID key Gross/Net/Tare key Press to switch between kg and lb. Press to enter the ID mode. Use the numeric keypad to enter the user s ID number. Press to toggle among Gross Weight, Net Weight, and Tare Weight on the display. 5

Using the weighing scale Counting function 1. Put certain pieces of objects on to the scale pan. 2. In weighing mode, press, and then use & keys to set the piece counts. 3. Press to confirm. 4. Now you are ready to perform parts counting for the specific samples. Percentage function 1. Put certain pieces of objects on to the scale pan. 2. Press and then use & keys to enter the percentage of the sample, 3. Press to confirm. 4. Place objects of desired piece counts on the weighing pan. The percentage of the objects will be calculated automatically. Operation of M+ 1. When there is a load on the weighing pan, press and after a beep sound, the indicator let to M+ icon will light up on the LCD, indicating a data has been recorded. 2. Clear the load and put another load on the weighing pan. When the scale become stable, press to record another load weight After each recording, if the load on the weighing pan is not cleared, pressing will result in the beep and the scale won t be able to record the next weighing result. The stored memory can memorize up to 180 weighing results. Operation of MR 1. In weighing mode, press to display the accumulated weighing result. The LCD display will show the total number of accumulation and the total weight alternatively. For instance, if you added two weighing results and the total weight add up to 4.0 kg. The scale will show tot.002, and 4.000 kg 6

2. Press to exit the MR mode without clearing the data in memory. Alarm function 1. Press key to set the upper bound of the weight. The Hi is showing in the left window. 2. Set up the weight upper bound with the & keys. Press to confirm to save your Hi setting. And then move to Lo setting. 3. The Lo is showing in the left window. Press the & keys to set the lower bound of the weight. 4. Press to confirm to save your Lo setting. And then back to weighing mode. Note: While the weight exceeds the upper bound of Weight Upper Bound, or lower than the Weight Lower Bound, or between the lower and upper bound and is not zero, the scale may beep for warning. You may change the beep settings in CAL 1 menu. 7

Settings and Calibration 1. Press and hold any key while turning the scale ON. CAL 1 is shown on the LCD display. 2. Press key to toggle among the CAL 1, CAL 2, CAL 3, and CAL 4 menus. 3. Select CAL 1, press to enter General Settings menu. 4. Select CAL 2, press to enter the Print Settings menu 6. Select CAL 3, press to enter Calibration procedure. 7. Select CAL 4, press to enter Linearity Calibration procedure. Note: To perform CAL 3 and CAL 4 calibration, you must remove the JP3 jumper from the PCB first. Put the JP3 back after calibration is complete. General Settings (CAL 1) In the General Settings menu, press to toggle among the options, and to confirm. 1. Aut.oFF Auto Off Setting A.oFF 0 Disable auto shutdown function. A.oFF 1 If there is no operation, the scale will shut down in 5 minutes. A.oFF 2 If there is no operation, the scale will shut down in 10 minutes. A.oFF 3 If there is no operation, the scale will shut down in 20 minutes. A.oFF 4 If there is no operation, the scale will shut down in 30 minutes. 2. Pcnt.dP Percentage decimal Setting Pcnt.dP 0.0 100.0 %. Pcnt.dP 0.00 100.00 % 3. bbh - Hi Beep Setting Display Explanation bbh_ 0 Disable Hi alarm sound. bbh_ 1 Set Hi alarm sound as continual short beeps. bbh_ 2 Set Hi alarm sound as continual long beeps. 8

4. bbs - Go Beep Setting Display Explanation bbg_ 0 Disable Hi alarm sound. bbg_ 1 Set Hi alarm sound as continual short beeps. bbg_ 2 Set Hi alarm sound as continual long beeps. 5. bbl Lo Beep Setting Display Explanation bbl_ 0 Disable Hi alarm sound. bbl_ 1 Set Hi alarm sound as continual short beeps. bbl_ 2 Set Hi alarm sound as continual long beeps. Print Settings (CAL 2) Press to toggle among the options. Use the numeric keys to input data and press to save your settings. 1. Print Settings Display Pr.dEFA Pr.LP50 Descriptions Set the print format to default settings. Set the print format to LP-50 printer. 2. Printout setting Display Descriptions P. PrESS Press M+ to print single weighing result. Press C in MR mode to print accumulated weighing result and total accumulation. P. StAb.1 Print weighing result (Net wt, Pc. wt, Pc. count) when the scale is stable and weight > 0. * Pressing M+ and MR do not print. P. StAb.2 Print Net wt when the scale is stable and weight > 0. * Pressing M+ and MR do not print. P. ALL.1 Press M+ to print single weighing result. Press C in MR mode to print accumulated weighing result and total accumulation. Print weighing result (Net wt, Pc. wt, Pc. count) when the scale is stable and weight > 0. 9

P. ALL.2 Press M+ to print single weighing result. Press C in MR mode to print accumulated weighing result and total accumulation. Print Net wt when the scale is stable and weight > 0. P.Count Continuous printing weight data. Usually used for sending weight data to PC. P. off Print function disabled. 3. Baud Rate Display Descriptions br2400 Set the baud rate to 2400 br4800 Set the baud rate to 4800 br9600 Set the baud rate to 9600 4. Parity Setting Display PA. 7-E-1 PA. 7-o-1 PA. 7-n-2 PA. 8-n-1 PA. 8-E-1 PA. 8-o-1 Descriptions Set the parity to 7-E-1 Set the parity to 7-o-1 Set the parity to 7-n-2 Set the parity to 8-n-1 Set the parity to 8-E-1 Set the parity to 8-o-1 10

Calibration Procedure (CAL 3) Please remove the JP3 jumper before you start the calibration process. In Calibration menu, press 1. SEL maximum capacity Display LoAd 06d LoAd 15d LoAd 30d to toggle among the menu options. And press Descriptions Set maximum capacity as 6 kg. Set maximum capacity as 15 kg. Set maximum capacity as 30 kg. to confirm. 2. A0 A0 0(off) Zero tracking function is disabled. A0 1(on) Zero tracking function is activated. 3. Zero Point Calibration The right window shows AD Value of Zero weight. Wait until Pnt. 0 XXXXXX the AD value becomes stable, press to confirm. 4. Setup calibration weight Display Pnt. CAL XXXXXX Descriptions Put 1/3 or 2/3 or 3/3 of full load on the weighing pan. The right window shows AD Value of the load. Wait until the AD value becomes stable, press to confirm. The right window will cycle display the 1/3,2/3,3/3 of full Pnt. CAL 1/2/30000 load. When the weight displayed equal to the load weight, press to confirm. The window will show done. Remove the load from the weighing pan, and the scale will restart and the calibration is done. 11

Linearity Calibration Procedure (CAL 4) Note: This section can only be operated by engineers. Please have the jumper JP3 switch OFF before you start the calibration process. In Calibration menu, press to toggle among the menu options. And press to confirm. 1. Zero Point Calibration Display Pnt 0 Descriptions The AD Value is then displayed in the right window. Make sure the weighing pan is empty. Wait until the AD value becomes stable, press proceed. to 2. Calibration by 1/3 of the maximum capacity Pnt 1 The AD Value of 1/3 of the full load is then displayed. Put on poise of the 1/3 weight by the maximum capacity. Wait until the AD value becomes stable, press to proceed. 3. Calibration by 2/3 of the maximum capacity Pnt 2 The AD Value of 2/3 of the full load is then displayed. Put on poise of the 2/3 weight by the maximum capacity. Wait until the AD value becomes stable, press to proceed. 4. Calibration by the maximum capacity Pnt 3 The AD Value of the full load is then displayed. Put on poise of full capacity of the scale. Wait until the AD value becomes stable, press linearity calibration is complete.. The 12

RS232C Connection: DB-09 (Male) Pin setup: 2 (TXD) 3 (RXD) 5 (GND) others (NC) Bi-directional RS232C Setting This section is applicable only for models with RS-232C module. OUTPUT FORMAT STA SIGN W 6 W 5 W 4 W 3 W 2 W 1 W 0 SPACE U 1 U 0 CR LF STA U (55h) indicates it s an unstable weight. S (53h) indicates it s a stable weight. SIGN - (2Dh) means it s a negative weight. (20h) space char indicates it s a positive or zero weight. W 6 W 0 SPACE U 1, U 0 Weight data, decimal point included. 20h k (6Bh) g (67h) indicates that the unit is kilogram. l (6CH) b (62h) indicates that the unit is lb. CR LF 0Dh 0Ah Command: COMMAND Actions Response <ENQ> (05h) the weight string (not available when the print format is set to OFF or PRESS.) 13