AW/AHW Professional Weighing Scale. User Manual

Similar documents
GW Professional Weighing Scale. User Manual SNOWREX INTERNATIONAL CO., LTD. SRGW

Bright Advance Corporation

244241, Operation Manual Contents subject to change without notice. Version 1.0 Issue AA

Operation Manual Contents subject to change without notice

OP-02 / OP-03 / OP-04

Acceleration/Velocity/Displacement VIBRATION METER

PS R975B 12R976B 12R977B 12R978B 12R979B

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!"#$%&'()*%!+#,&-('.!!!!!!

Dual laser + type K thermometer INFRARED THERMOMETER

MS Operation Manual

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

Operation Manual for DC-788

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

Digital Torque Meter ADT-C Series OPERATION MANUAL

Vetek Weighing AB JWL Service Manual. Service Manual. May not be reproduced in any form without written permission PAGE 0

Property of Monitronics Inc

NV-DVR09NET NV-DVR016NET

PiCUS Calliper Version 3

PAX2S Modbus Register Table REVISED 2/20/12 LP0894A

Service Manual for DS-781/782(RS)

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this

WEIGHT INDICATOR WIDRA W90

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

Operating instruction Platform scale

INSTRUCTION MANUAL Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements

User's Guide. DISTO online. Leica Geosystems

Instruction Manual HI Refractometer for Sodium Chloride Measurements

ea980r Digital Anemometer User Manual

Consists of several displays that provide you with useful information. Odometer, Trip meter. distribution monitor. Bluetooth HandsFreeLink

TitraLab 580 and 585. KF Titration Workstations. Reference Manual D21T083

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

Instruction Manual. HI Refractometer for Sucrose in Wine and Grape Products Measurements

Jasco V-670 absorption spectrometer

MULTIFUNCTION COMPUTER METER CX-742 USERS MANUAL

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

SuperCELL Data Programmer and ACTiSys IR Programmer User s Guide

VIBRATION METER. Instruction Manual.

RADIATION-METER TM-91/TM-92

Measure - Conductivity STANDARD Last std: Sep 10:17 am. Touch meas to measure sample. Touch std to access standardize mode ATC. 25.

610,- KERN ADB. Analytical balances. Quick-Finder Analytical balances. Large glass draught shield with 3 sliding doors

MAN-SGY-012-V11 EC 5195 Fairford Electronics Ltd - Synergy Modbus RTU Programming Manual - 22nd February 2016 Page 1 of 59.

Instruction Manual HI Refractometer for Sucrose in Wine and Grape Products Measurements

INSTRUCTION MANUAL Milwaukee Refractometer MA872 Refractometer for Fructose Measurements

OPERATING INSTRUCTIONS


VELA. Getting started with the VELA Versatile Laboratory Aid. Paul Vernon

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

zulu - inca - kundalini - cozmo Welcome to the Ownership of a YES Watch.

An ultra-sensitive, versatile, and affordable single tube luminometer for Life Science Research.

PC User s manual. Advanced Electronic/Air Column PC BOWERS METROLOGY page 1 /32 version E

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

MODBUS Protocol for CS141 network card families

TitraLab 854 and 856. ph-stat Titration Workstations. Reference Manual D21T054

Minimum (-31) every 10 s -35 (-31)

Sales Analysis User Manual

Conservation of Mechanical Energy Activity Purpose

Dewpoint Meter Data Sheet / Instructions

CHV Series Vector Control Inverter Options. Operating Instructions for Tension Control Card

InfraRed Thermometer with Laser Pointer

Operating Instructions 5 Day Weather Station with Color Screen Model: DG-TH8805 INDOOR UNIT

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

Bante210 Benchtop ph Meter Instruction Manual

Data Sheet / Instructions. Dewpoint MeterO

Creating Empirical Calibrations

TitraLab 870. Reference Manual. ph/ep/ip/ec/ise Titration Workstation D21T060

HD32.2 WBGT Index HD 32.2 INSTRUMENT FOR THE ANALYSIS OF THE WBGT INDEX

GT-510/510L series Instruction Manual

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

PAA-ANALYZERS PRINCIPLE OF OPERATION

MPP5800 series - PANEL MOUNT PRINTERS. Options

MP3 Digital Voice Module Model No.: VCM-SD Rev.A3. Content

MODELS 3340/3345 ION METERS OPERATING MANUAL

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

GPS Scout Backtrack Altimeter Model: GP123 USER MANUAL

Digital Controller Operation

QUANTUM CONCEPT. Swimming User s Manual

Experiment P14: Collision Impulse & Momentum (Force Sensor, Motion Sensor)

Casio G SHOCK watches Specifications

INSTRUCTION MANUAL Milwaukee Refractometer MA888 Refractometer for Ethylene Glycol Measurements

Mini Environmental Quality Meter

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

CZ-53X Series IR Night Vision

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

Experiment P30: Centripetal Force on a Pendulum (Force Sensor, Photogate)

473-SHX Dew Point Mirror

SC400 Colorimeter. Silica. Photometer-System. Instruction Manual. SiO 2. Bedienungsanleitung Seite Instruction Manual Page 19 33

Circular Motion and Centripetal Force

TOUCH SCREEN WEATHER STATION MODEL WS-3650

After publication, this Indian Standard will supersede the following Indian Standards:

2 ACCESSING VARIOUS MODES

RHS 980C OPERATION MANUAL

INFRARED THERMOMETER TM0819

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Instructor s Advance Preparation

ION570. Reference Manual. Ion Analyser D21M073

Automatic titrators, TitroMatic

Transcription:

AW/AHW Professional Weighing Scale User Manual Sep. 2009

Table of Contents Specifications... 2 Basic specification... 2 Series specification... 2 Display and keypad... 3 LCD Display... 3 Keypad... 4 Using the weighing scale... 6 Counting function... 6 Percentage function... 6 Operation of M+... 6 Operation of MR... 6 Alarm function... 7 Input tare weight by keypad... 7 Settings and Calibration... 8 General Settings (CAL 1)... 8 Settings (CAL 2)... 9 Calibration Procedure (CAL 3)...11 Linearity Calibration Procedure (CAL 4)... 12 RS232C Connection: DB-09 (Male)... 13 Bi-directional RS232C Setting... 13 1

Specifications Basic specification Digital Display LCD, height 40 mm x 125 mm 6 digitals Platter Size (mm) 245 x 355 (W x H) Dimensions (mm) 387 x 365 x 117(W x L x H) Net Weight (kg) 3.7kg Operating Temperature 0 to +40 Relative Humidity Less than 85% Power 9V / 500mA, AC adapter; Built in 6V Rechargeable Battery Interface RS-232C Series specification Model AW Max. Capacity 1.5kg/3lb 3kg/6lb 7.5kg/15lb 15kg/30lb 30kg/60lb 50kg/100lb d = 0.1g 0.2g 0.5g 1g 2g 2g Accuracy 1/15000 1/15000 1/15000 1/15000 1/15000 1/25000 Model AHW Max. Capacity 3kg/6lb 6kg/12lb 15kg/30lb 30kg/60lb 50kg/100lb d = 0.1g 0.2g 0.5g 1g 1g Accuracy 1/30000 1/30000 1/30000 1/30000 1/50000 2

Display and keypad LCD Display. Numerical display to display weight, date & time, ID number Indicates the weight is stable. Indicates the weight is at zero. Hi-Lo M+ Indicates the accumulation weight in memory. G.W When is shown above the G.W. indicator, the Gross Weight is displayed. N.W. When is shown above the N.W. indicator, the Net Weight is displayed. T.W When is shown above the T.W. indicator, the Tare Weight is displayed. Hi When you are setting the weight upper bound, is flashing above the Hi indicator. Lo When you are setting the weight lower bound, is flashing above the Lo indicator. 3

Keypad Key Icons Keypad Descriptions Off key Press to switch the scale OFF. ~ On key Zero key Tare key Numeric and decimal keys Press to turn the scale ON. Press to absorb trivial weight on the pan and set the scale to zero. Press to perform tare operation. Press the numeric and decimal keys to input data such as piece weight, quantity etc. Clear key Press to clear the input data. M+ key Press to accumulate piece counting and weighing results. MR key Press to recall total number of accumulation and total weighing. Hi key Press to set alarm for weight upper bound. Lo key Press to set alarm for the weight low bound. 4

Function key Press to toggle among, Hi/Lo, %, sampling. Sampling key Press to set up sample quantity. (Sample key: multiple sampling methods are available. See Sampling section.) Percentage key Press to set up percentage of the given sample. key Press to print the weight data. Unit key Date &time key ID key Gross/Net/Tare key Press to switch between kg and lb. Press to display the current date and time. Note: The date and time setting can be changed in CAL 1 menu. Press to enter the ID mode. Use the numeric keypad to enter the user s ID number. Press to toggle among Gross Weight, Net Weight, and Tare Weight on the display. 5

Using the weighing scale Counting function 1. Put certain pieces of objects on to the scale pan. 2. In weighing mode, press the numeric key to set the piece count and press. 3. Now you are ready to perform parts counting for the specific samples. The input data will be cleared in 4 seconds if is not pressed. Percentage function 1. Put certain pieces of objects on to the scale pan. 2. Press and use the numeric key to enter the percentage of the sample.. 3. Place objects of desired piece counts on the weighing pan. The percentage of the objects will be calculated automatically. Operation of M+ 1. When there is a load on the weighing pan, press and after a beep sound, the M+ indicator will light up on the LCD, indicating a data has been recorded. 2. Clear the load and put another load on the weighing pan. When the scale become stable, press. After a beep sound, the M+ indicator will light up on the LCD, indicating second data has been recorded. After each recording, if the load on the weighing pan is not cleared, pressing will result in the long beep and the scale won t be able to record the next weighing result. The stored memory can memorize up to 180 weighing results. Operation of MR 1. In weighing mode, press to display the accumulated weighing result. The LCD display will flash the total number of accumulation and the total weight alternatively. For instance, if you added two weighing results and the total weight add up to 2.0 kg. The scale will flash ACC.002, and then 2.000kg 6

2. Press to exit the MR mode without clearing the data in memory. Alarm function 1. Press key to set the upper bound of the weight. The is flashing above the Hi indicator. 2. Set up the weight upper bound with the numeric keys Press key again to save your setting and return to normal weighing mode. 3. Press key to set the lower bound of the weight. The is flashing above the Lo indicator. 4. Set up the lower bound with the numeric keys. 5. Press key again to save your setting and return to weighing mode. Note: While the weight exceeds the upper bound of Weight Upper Bound, or lower than the Weight Lower Bound, or between the lower and upper bound and is not zero, the scale will beep for warning. You may change the beep settings in CAL 1 menu. Input tare weight by keypad 1. In weighing mode, press the numeric keys to input the tare weight. (The unit is in gram.) 2. Then, press, and the tare weight has been changed. (The input data will be cleared in 4 seconds if is not pressed.) Note: It s not allowed to set tare weight greater than scale capacity. 7

Settings and Calibration 1. Press and hold any key while turning the scale ON. CAL 1 is shown on the LCD display. 2. Press key to toggle among the CAL 1, CAL 2, CAL 3, and CAL 4 menus. 3. Select CAL 1, press to enter General Settings menu. 4. Select CAL 2, press to enter the Settings menu 6. Select CAL 3, press to enter Calibration procedure. 7. Select CAL 4, press to enter Linearity Calibration procedure. Note: To perform CAL 3 and CAL 4 calibration, you must remove the JP3 jumper from the PCB first. Put the JP3 back after calibration is complete. General Settings (CAL 1) In the General Settings menu, press to toggle among the options, and to confirm. 1. Aut.oFF Auto Off Setting Display Descriptions A.oFF 0 Disable auto shutdown function. A.oFF 1 If there is no operation, the scale will shut down in 5 minutes. A.oFF 2 If there is no operation, the scale will shut down in 10 minutes. A.oFF 3 If there is no operation, the scale will shut down in 20 minutes. A.oFF 4 If there is no operation, the scale will shut down in 30 minutes. 2. B. LiGHt - Backlight Setting Display Descriptions bl 0 Disable the backlight function. bl 1 Enable the backlight function. bl 2 Automatic backlight when there is load on the weighing pan. 3. bbh - Hi Beep Setting Display Explanation bbh_ 0 Disable Hi alarm sound. bbh_ 1 Set Hi alarm sound as continual short beeps. bbh_ 2 Set Hi alarm sound as continual long beeps. 8

4. bbs - Go Beep Setting Display Explanation bbs_ 0 Disable Go alarm sound. bbs_ 1 Set Go alarm sound as continual short beeps. bbs_ 2 Set Go alarm sound as continual long beeps. 5. bbl Lo Beep Setting Display Explanation bbl_ 0 Disable Lo alarm sound. bbl_ 1 Set Lo alarm sound as continual short beeps. bbl_ 2 Set Lo alarm sound as continual long beeps. 6. dny-date Setting (dd/mm/yy) 1. Current date is shown on the display. Press the Date key to select the field for adjustment. 2. The date format is displayed as DD/MM/YY. For example to set the date as April 17, 2009, press the date key to select the date field. 3. Enter the date with numeric keypad and press date key to go to the next field. 4. When the set up is complete, press tare to save your settings. 7. HNS-Time Setting (hh/mm/ss) 1. Current date is shown on the display. Press the Date key to select the field for adjustment. 2. The date format is displayed as H/M/S. For example to set the date as 16: 50: 23, press the date key to select the date field. 3. Enter the date with numeric keypad and press date key to go to the next field. 4. When the set up is complete, press tare to save your settings. Settings (CAL 2) Press to toggle among the options. Use the numeric keys to input data and press to save your settings. 1. Settings Display Pr.dEFA Pr.LP50 Descriptions Set the print format to default settings. Set the print format to LP-50 printer. 9

2. out setting Display Descriptions P. PrESS Press M+ to print single weighing result. Press C in MR mode to print accumulated weighing result and total accumulation. P. StAb.1 weighing result (Net wt, Pc. wt, Pc. count) when the scale is stable and weight > 0. * Pressing M+ and MR do not print. P. StAb.2 Net wt when the scale is stable and weight > 0. * Pressing M+ and MR do not print. P. ALL.1 Press M+ to print single weighing result. Press C in MR mode to print accumulated weighing result and total accumulation. weighing result (Net wt, Pc. wt, Pc. count) when the scale is stable and weight > 0. P. ALL.2 Press M+ to print single weighing result. Press C in MR mode to print accumulated weighing result and total accumulation. Net wt when the scale is stable and weight > 0. P.Count Continuous printing weight data. Usually used for sending weight data to PC. P. off function disabled. 3. Baud Rate Display Descriptions br2400 Set the baud rate to 2400 Br4800 Set the baud rate to 4800 br9600 Set the baud rate to 9600 4. Parity Setting Display PA. 7-E-1 PA. 7-o-1 PA. 7-n-2 PA. 8-n-1 Descriptions Set the parity to 7-E-1 Set the parity to 7-o-1 Set the parity to 7-n-2 Set the parity to 8-n-1 10

Calibration Procedure (CAL 3) Please remove the JP3 jumper before you start the calibration process. In Calibration menu, press to toggle among the menu options. Use the numeric keys to input data and press to confirm. 1. SEL maximum capacity Display LoAd 03 LoAd 06 LoAd 15 LoAd 30 LoAd 50 Descriptions Set maximum capacity as 3 kg. Set maximum capacity as 6 kg. Set maximum capacity as 15 kg. Set maximum capacity as 30 kg. Set maximum capacity as 50 kg. 2. A0 Display A0 off A0 on Descriptions Zero tracking function is disabled. Zero tracking function is activated. 3. Zero Point Calibration Display Descriptions XXXXXX 0 Firstly, it shows AD Value at Zero point. Press. Make sure the weighing pan is empty. Wait until the AD value becomes stable, press proceed. 4. Setup calibration weight Display Descriptions And put on the calibration weight either by 1/3, 2/3 of the full XXXXXX capacity or the full load. The corresponding AD value is then to displayed. When AD value become stable, press. The displays will shows 1/3, 2/3 of the full capacity in cycle. 11

When the displayed number corresponds to the calibration weight user is using, press to confirm. Linearity Calibration Procedure (CAL 4) Note: This section can only be operated by engineers. Please have the jumper JP3 switch OFF before you start the calibration process. In Calibration menu, press to toggle among the menu options, and to confirm. 1. Zero Point Calibration Display Pnt 0 Descriptions The AD Value is then displayed. Make sure the weighing pan is empty. Wait until the AD value becomes stable, press to proceed. 2. Calibration by 1/3 of the maximum capacity Display Descriptions Pnt 1 The AD Value of 1/3 of the full load is then displayed. Put on poise of the 1/3 weight by the maximum capacity. Wait until the AD value becomes stable, press to proceed. 3. Calibration by 2/3 of the maximum capacity Display Descriptions Pnt 2 The AD Value of 2/3 of the full load is then displayed. Put on poise of the 2/3 weight by the maximum capacity. Wait until the AD value becomes stable, press to proceed. 4. Calibration by the maximum capacity Display Descriptions Pnt 3 The AD Value of the full load is then displayed. Put on poise of full capacity of the scale. Wait until the AD value becomes stable, press linearity calibration is complete. Note: For 50 kg instrument, 5 section linearity calibrations are required.. The 12

RS232C Connection: DB-09 (Male) Pin setup: 2 (TXD) 3 (RXD) 5 (GND) others (NC) Bi-directional RS232C Setting This section is applicable only for models with RS-232C module. PRINTOUT FORMAT 1. Key press print Setting Press M+ Press Press C in MR mode ITEM 1 : Date 02-04-2009 Time TRANSACTION TOTAL PrESS ---------------------- 07:38:59 ---------------------- ALL.1 ALL.2 Date 02-04-2009 Time 07:38:35 ID :888888 Gross Weight: S 10.000 kg Net Weight : S 10.000 kg Tare Weight : S 0.000 kg ID :888888 Gross Weight: S 10.000 kg Net Weight : S 10.000 kg Tare Weight : S 0.000 kg TOTAL NET WEIGHT of 1 ITEM(S) : 10.000 kg StAbLE.1 StAbLE.2 No print out. No print out. No print out. off 13

2. Stable auto print Setting StAbLE.1 ALL.1 out when the weight is stable. Date 02-04-2009 Time 07:40:23 ID :888888 Gross Weight: S 10.000 kg Net Weight : S 10.000 kg Tare Weight : S 0.000 kg ALL.2 Net Weight:S 10.000 kg StAbLE.2 PrESS No print out. off STA SIGN W 6 W 5 W 4 W 3 W 2 W 1 W 0 SPACE U 1 U 0 CR LF STA U (55h) indicates it s an unstable weight. S (53h) indicates it s a stable weight. SIGN - (2Dh) means it s a negative weight. (20h) space char indicates it s a positive or zero weight. W 6 W 0 SPACE U 1, U 0 Weight data, decimal point included. 20h k (6Bh) g (67h) indicates that the unit is kilogram. l (6CH) b (62h) indicates that the unit is lb. CR LF 0Dh 0Ah Command print out COMMAND Actions Response <ENQ> (05h) the weight string (not available when the print format is set to OFF or PRESS.) 14