NEW Rtx -BAC Plus 1 and Rtx -BAC Plus 2 Columns

Similar documents
Rtx-BAC Plus 1 and Rtx-BAC Plus 2 Columns Advanced Technology for Fast, Reliable Measurement of Alcohol in Blood

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

Virtually Particle-Free Rt -Silica BOND Columns

Study of Residual Solvents in Various Matrices by Static Headspace

Activity in the FID Detection Port: A Big Problem if Underestimated

Definitive EtG/EtS LC-MS/MS Analysis:

Tri-n-propyltin Chloride Mixture

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Evaluation of a New Analytical Trap for Gasoline Range Organics Analysis

Rtx -CLPesticides Columns Reduce Analysis Time; Reduce System Maintenance

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products.

Secrets of GC Column Dimensions

Headspace Technology for GC and GC/MS: Features, benefits & applications

DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making

Blood Alcohol Determination using Static Headspace Analysis with Optimized Sample Throughput

Residual solvents analysis using an Agilent Intuvo 9000 GC system

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Understanding Gas Chromatography

Certified BTEX in Unleaded Gas Composite

DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Rely on Rxi -PAH Columns

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note.

Introduction to Capillary GC

Trajan SGE GC Columns

Rxi -624Sil MS The "Go To" GC Column for Fast, Effective Volatile Impurities Method Development

Application. Gas Chromatography February Introduction

Selection of a Capillary GC Column

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Fast, Quantitative Analysis of Residual Solvents in Cannabis Concentrates

Column Dimensions. GC Columns and Consumables. Mark Sinnott Application Engineer. March 12, 2010

Introduction to Capillary GC

-xt. -xt SYSTEM. Specifications for PAL-xt Systems. Valid for PAL-xt System models only. Prep and Load Platform

Monomer Analysis. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System

Simultaneous dual capillary column headspace GC with flame ionization confirmation and quantification according to USP <467> Application Note

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

USP Class 1 Residual Solvent Mixture

A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source

US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS

New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Roger Bardsley, Applications Chemist; Teledyne Tekmar P a g e 1

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column

Analytical Trap Comparison for USEPA Method 8260C

Chemistry Gas Chromatography: Separation of Volatile Organics

Delta-9-THC Standard. Catalog # Lot # A082745

Analysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

The Determination of Residual Solvents in Pharmaceuticals Using the Agilent G1888 Network Headspace Sampler Application

US EPA Method with the Tekmar Lumin P&T Concentrator, AQUATek LVA and Agilent 7890B GC/5977A MS

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated

Simultaneous Compound Identification and Quantification with Parallel Polyarc /FID and MS

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

A New Web-Based Application for Modeling Gas Chromatographic Separations

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Continuous Improvement in Petroleum/Petrochemical Analysis HP s Family of Innovative PLOT Columns

Water Injections in GC - Does Water Cause Bleed?

Fast Analysis of USP 467 Residual Solvents using the Agilent 7890A GC and Low Thermal Mass (LTM) System

Introduction and Principles of Gas Chromatography

Hydrogen as a Carrier Gas in the Analysis of Polar/Non-Polar Compounds Using the Polyarc System. Application Note. Author. Introduction.

Metolachlor ESA Sodium Salt Standard

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Helium conservation in volatile organic compound analysis using U.S. EPA Method 8260C

Selection of a Capillary

Volatile Organic Compounds in Every Day Food

Column Selection. there is more to life than a boiling point column. Jaap de Zeeuw Restek Corporation, The Netherlands. Copyrights: Restek Corporation

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions

Organochlorine Pesticides by GCxGC-ECD

Chapter 31 Gas Chromatography. Carrier Gas System

Analysis of Volatile Organic Compounds in Soil Samples by EPA Method 8260 with The Stratum PTC and SOLATek 72 Multi-Matrix Autosampler

Maximizing Sample Throughput In Purge And Trap Analysis

Solid Phase Micro Extraction of Flavor Compounds in Beer

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography

Analysis of Volatile Organic Compounds Using USEPA Method 8260 and the 4760 Purge and Trap and the 4100 Autosampler

Using Hydrogen as An Alternative Carrier Gas for US EPA 8260

A Technical Guide for Static Headspace Analysis Using GC Inside: Basic Principles of Headspace Analysis

Methanol Extraction of high level soil samples by USEPA Method 8260C

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs)

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS

Analysis of Volatile Organic Compounds in Water and Soil by EPA Method 8260 with the Atomx Concentrator/Multimatrix Autosampler

Uncontrolled Copy. SOP 109 Ethylene Glycol Screen by Gas Chromatography/Mass Spectrometry. Table of Contents. 1. Principle of Assay...

Transcription:

NEW Rtx -BAC Plus and Rtx -BAC Plus Columns Advanced Technology for Fast, Reliable Measurement of Alcohol in Blood Optimized column selectivities guarantee resolution of ethanol, internal standards, and common interferences. Quality testing of every column with target analytes ensures reliable performance. minute analysis time increases lab productivity. Innovative Chromatography Products www.restek.com

New Rtx -BAC Plus and Rtx -BAC Plus Columns Advanced Technology for Fast, Reliable Measurement of Alcohol in Blood Getting accurate, reliable results quickly is critical for labs analyzing blood alcohol concentration (BAC). New Rtx -BAC Plus and Rtx -BAC Plus columns provide definitive data in a fast, -minute analysis, so you can be certain of your results and maximize sample throughput. Blood alcohol content is often determined using headspace injection and dual column GC-FID analysis. While this is a relatively straightforward procedure, column choice plays a major role in data quality and reliability. In order to produce accurate results, the primary and confirmation columns must fully separate target analytes from all interferences and produce symmetrical peaks. Due to deficiencies in selectivity and inertness, coelution and tailing peaks are observed on competitor columns, which make confident reporting of target alcohols difficult. Best Overall Performance New Rtx -BAC Plus and Rtx -BAC Plus columns have optimized column selectivities, which result in optimized resolution of all target compounds, as well as the retention time and elution order changes necessary for confirmation. These new columns outperform other blood alcohol column pairs and ensure baseline separation of all critical compounds, including ethanol, methanol, acetone, tert-butanol (IS), acetaldehyde, isopropanol, and -propanol (IS), in less than minutes (Figure ). The separation of tert-butanol is especially notable as it has recently been adopted as an internal standard for BAC headspace analysis, but coelutes with acetone on some columns. In addition to being fully separated, target compounds exhibit excellent peak symmetry on Rtx -BAC Plus columns, allowing more accurate integration. In contrast, alcohol peaks on competitor columns display tailing, which can make integration difficult. As shown in Table I and Figure, the Rtx -BAC Plus columns produce the best peak shape for ethanol among the columns tested. Quality Counts Every Rtx -BAC Plus and Plus column is conditioned at maximum isothermal temperature and quality tested with the analytes shown in Figure to ensure reliable separations of all target compounds. Quality specifications for retention and efficiency ensure consistent column-to-column performance, and tightly controlled manufacturing results in robust columns with long lifetimes. The maximum temperature of these 00% chemically bonded columns is 0 C. Compared to other columns, new Rtx -BAC Plus and Rtx -BAC Plus columns offer the best overall performance for blood alcohol analysis. These columns provide fully separated, highly symmetrical peaks in a fast -minute analysis, allowing analysts to determine blood alcohol concentration quickly and report results with certainty. Table I: Rtx -BAC Plus and Rtx -BAC Plus columns exhibit both baseline resolution of critical compounds and excellent peak shape compared to other blood alcohol columns available. Column Resolution (Methanol/Acetaldehyde) Resolution (Acetone/tert-Butanol) USP Tailing Factor (Ethanol) Rtx -BAC Plus -..8 DB -ALC - 0..0 ZB BAC -..8 Rtx -BAC Plus. -.089 DB -ALC. -. ZB BAC.8 -.08

Figure : Rtx -BAC Plus columns provide the best overall performance for determining blood alcohol concentration. Highly symmetrical, baseline separated peaks provide fast and definitive results for all target compounds. Primary Analysis Confirmational Analysis Rtx -BAC Plus Baseline separation of all compounds. Symmetrical alcohol peaks. Rtx -BAC Plus Narrow, highly symmetrical peaks. All compounds separated in a fast, -minute analysis. RESTEK Peaks Conc. (µg/ml). Methanol 00. Acetaldehyde 00. Ethanol 00. Isopropanol 00. Acetone 00. t-butanol 0. -Propanol 0 Peaks Conc. (µg/ml). Acetaldehyde 00. Methanol 00. Ethanol 00. Acetone 00. Isopropanol 00. t-butanol 0. -Propanol 0 0.... GC_CF 0. 0.... GC_CF AGILENT DB -ALC Coelution of acetone and tert-butanol; tailing alcohol peaks., DB -ALC Tailing alcohols, broad peaks. PHENOMENEX 0. 0.... GC_CF 0..... ZB-BAC ZB-BAC Tailing alcohol and acetone peaks; minimal separation of methanol and acetaldehyde. Broad peaks with extensive tailing on alcohols. GC_CF 0. 0.... GC_CF8 0. 0.... GC_CF9 Columns: Rtx -BAC Plus, 0 m, 0. mm ID,.8 μm (cat.# 800); Rtx -BAC Plus, 0 m, 0. mm ID, 0. μm (cat.# 800); DB -ALC and ZB-BAC, 0 m, 0. mm ID,. μm; DB -ALC and ZB-BAC, 0 m, 0. mm ID,. μm; Sample: 0 µl each of BAC resolution control standard n-p (cat.# 00) and BAC resolution control standard t-b (cat.# 0) diluted in 900 µl water in a 0 ml headspace vial; Injection: Headspace-loop split (split ratio 0:); Liner: mm ID straight inlet liner (cat.# 09); Headspace-Loop: Inj. Port Temp.: 00 C; Instrument: Tekmar HT; Transfer Line Temp.: C; Valve Oven Temp.: C; Standby Flow Rate: 0 ml/min; Sample Temp.: 0 C; Sample Equil. Time: min; Vial Pressure: 0 psi; Loop Pressure: 0 psi; Loop Fill Time: min; Oven: 0 C (hold min); Carrier Gas He, constant flow; Linear Velocity: 80 cm/sec @ 0 C; Detector FID @ 0 C; Make-up Gas: Nitrogen, 0 ml/min; Instrument Agilent/HP890 GC; Acknowledgement: Headspace concentrator courtesy of Teledyne Tekmar, Mason, OH. -8--00-800--88 www.restek.com

Other Applications Rtx -BAC Plus columns can be used for other low temperature applications for volatile organic compounds, due to their unique selectivity, retention, and inertness. For example, in the analysis of abused inhalants in Figure, most compounds are resolved between the columns with several elution order changes for confirmation. In addition, excellent peak shapes are observed. As shown in Figures and, Rtx -BAC Plus columns can also be used for single column applications, such as glycols or gamma-butyrolactone (GBL), which is a derivatized form of gamma-hydroxybutyrate (GHB). The low bleed character of these columns also makes them useful for mass spectrometry applications. Figure : Dual column analysis of abused inhalants. Rtx -BAC Plus Peaks BAC Plus RT (min) BAC Plus RT (min). Methanol.0.0. Ethanol.9.0. Isopropanol.0.0. Diethyl ether.9.. Acetone..89. Methylene chloride.0.0. MTBE.8.0 8. Hexane.8.0 9. Chloroform.9. 0. MEK.0. Peaks BAC Plus RT (min) BAC Plus RT (min). Ethyl acetate... Benzene.90.88. Trichloroethylene.0.. MIBK 8.0.. Toluene 8..0. Ethylbenzene 0.8.8. m-xylene 0.8.89 8. p-xylene 0.8.89 9. o-xylene 0.990 8., 8 9 8 9 0 0 8 0 Rtx -BAC Plus Time (min) 8,,, 8 9 0 9 0 8 0 Time (min) GC_CF Columns: Rtx -BAC Plus, 0 m, 0. mm ID,.8 μm (cat.# 800) and Rtx -BAC Plus, 0 m, 0. mm ID, 0. μm (cat.# 800) using Rxi guard column, m, 0. mm ID (cat.# 009) with Universal Y Press-Tight connector (cat.# 00-); Sample: 0 μg/ml each inhalant in water; Injection: headspace-loop split (split ratio 0:); Liner: mm straight inlet liner (cat.# 09); Headspace-Loop: Inj. Port Temp.: 0 C; Instrument: Tekmar HT; Inj. Time: min; Transfer Line Temp.: C; Valve Oven Temp.: C; Sample Temp.: 0 C; Sample Equil. Time: min; Vial Pressure: 0 psi; Pressurize Time: min; Loop Pressure: 0 psi; Loop Fill Time: min; Oven Temp: 0 C (hold min) to 0 C at 0 C/min (hold 0 min); Carrier Gas: He, constant flow; Linear Velocity: 0 cm/ sec; Detector: FID @ 0 C; Make-up Gas: N, 0 ml/min; Instrument: Agilent/HP890 GC; Notes The Rtx -BAC Plus and Plus columns were connected to the injection port using a ~ inch section of guard column between the injection port and the Universal Y Press-Tight connector. Headspace concentrator courtesy of Teledyne Tekmar, Mason, OH. www.restek.com -8--00-800--88

Figure : Separation of glycols on the Rtx -BAC Plus column. Peaks BAC Plus RT (min) BAC Plus RT (min). Ethylene glycol.98.0. Propylene glycol...,-propanediol.0.8. Diethylene glycol.80.8.... Time (min) GC_CF Columns: Rtx -BAC Plus, 0 m, 0. mm ID,.8 μm (cat.# 800); Sample: 00 μg/ml each glycol in methanol:water (0:0); Injection: µl split (split ratio 0:); Liner: Restek Premium mm straight inlet liner w/wool (cat.# 00.); Inj. Temp.: 0 C; Oven Temp: 0 C (hold 0 min) to 0 C at 0 C/min (hold min); Carrier Gas: He, constant flow; Linear Velocity: 0 cm/sec; Detector: FID @ 0 C; Make-up Gas: N, 0 ml/min; Instrument: Agilent/HP890 GC; Notes: Injections were performed manually with a Merlin Microshot injector (cat.# 9). Figure : Gamma-butyrolactone (GBL) and internal standard alphamethylene-gamma-butyrolactone (AMGBL) on an Rtx -BAC Plus column. Peaks. GBL. AMGBL Looking for other applications? Search our chromatogram library by compound name, synonym, CAS# or keyword at www.restek.com/chromatograms Learn the latest and chat with other chemists in our technical blog at blog.restek.com..8....8.. Time (min) GC_CF Columns: Rtx -BAC Plus, 0 m, 0. mm ID,.8 μm (cat.# 800); Sample: Gamma-butyrolactone (GBL) (cat.# 0) and alpha-methylene-gamma-butyrolactone (AMGBL) (cat.# 09); Injection: Headspaceloop split (split ratio 0:); Liner: mm ID straight inlet liner (cat.# 09); Headspace-Loop: Inj. Port Temp.: 00 C; Instrument: Tekmar HT; Inj. Time: min; Transfer Line Temp.: C; Valve Oven Temp.: C; Sample Temp.: 00 C; Sample Equil. Time: 0 min; Vial Pressure: 0 psi; Pressurize Time: min; Loop Pressure: 0 psi; Loop Fill Time: min; Oven: 80 C (hold 0 min) to 80 C at 0 /min (hold 0 min); Carrier Gas He, constant flow; Linear Velocity: 8 cm/sec; Detector FID @ 0 C; Make-up Gas: Nitrogen, 0 ml/min; Instrument Agilent/HP890 GC; Notes: Sample was prepared by injecting µl of each standard into a capped headspace vial. The mass of each compound inside the headspace vial was µg. Headspace concentrator courtesy of Teledyne Tekmar, Mason, OH. -8--00-800--88 www.restek.com

NEW Columns and Standards for Blood Alcohol Testing Rtx -BAC Plus /Rtx -BAC Plus Columns Optimized column selectivities guarantee resolution of ethanol, internal standards, and frequently encountered interferences. Robust and reproducible column chemistry ensures longer column lifetime and consistent results. minute analysis time increases lab productivity. Stable to 0 C Rtx -BAC Plus Columns (fused silica) Description temp. limits cat.# 0m, 0.mm ID,.80µm -0 to 0/0 C 800 0m, 0.mm ID,.00µm -0 to 0/0 C 800 Rtx -BAC Plus Columns (fused silica) Description temp. limits cat.# 0m, 0.mm ID, 0.µm -0 to 0/0 C 800 0m, 0.mm ID,.0µm -0 to 0/0 C 800 Visit www.restek.com/cft for the latest products and resources for clinical, toxicology, and forensic laboratories. Blood Alcohol Resolution Control Standards Use to verify the retention time for each compound normally included in a blood alcohol test, and to verify that the compounds are resolved from and do not interfere with one another. Includes -propanol or tert-butanol internal standard. Intended for qualitative use only. BAC Resolution Control Standard n-p ( components) acetaldehyde methanol acetone -propanol (n-propanol) ethanol (BAC) -propanol (isopropanol) 00mg/dL each in water, ml/ampul No data pack available. acetaldehyde acetone tert-butanol (TBA) 00mg/dL each in water, ml/ampul No data pack available. cat.# 00 (ea.) BAC Resolution Control Standard t-b ( components) cat.# 0 (ea.) ethanol (BAC) methanol -propanol (isopropanol) Blood Alcohol Standards (Calibration) NIST-traceable ethanol calibration standards. Calibration mixtures ranging from 0.00g/dL to 0.0g/dL in water. Datapack and Certificate of Analysis for each standard available on our website. Compound qty. cat.# 0.00g/dL forensic ethanol solution ml/ampul -pk. 0.0g/dL forensic ethanol solution ml/ampul -pk. 0.0g/dL forensic ethanol solution ml/ampul -pk. 0.0g/dL forensic ethanol solution ml/ampul -pk. 0.0g/dL forensic ethanol solution ml/ampul -pk. 0.0g/dL forensic ethanol solution ml/ampul -pk. 0.08g/dL forensic ethanol solution ml/ampul -pk. 0.g/dL forensic ethanol solution ml/ampul -pk. 0.g/dL forensic ethanol solution ml/ampul -pk. 0.g/dL forensic ethanol solution ml/ampul -pk. 0.g/dL forensic ethanol solution ml/ampul -pk. 8 0.g/dL forensic ethanol solution ml/ampul -pk. 9 0.g/dL forensic ethanol solution ml/ampul -pk. Rxi Guard/Retention Gap Columns (fused silica) Extend column lifetime. Excellent inertness obtain lower detection limits for active compounds. Sharper chromatographic peaks by utilizing retention gap technology. Maximum temperature: 0 C. Nominal ID Nominal OD -Meter -Meter/-pk. 0-Meter 0-Meter/-pk. 0. mm 0. ± 0.0 mm 009 009-00 009 009-00 0. mm 0. ± 0.0 mm 009 009-00 00 00-00 0. mm 0.9 ± 0.0 mm 00 00-00 00 00-00 www.restek.com -8--00-800--88

Chromatography Essentials Restek Premium.0 mm ID Straight Inlet Liners Exceptionally inert, Restek Premium inlet liners with state-ofthe-art deactivation improve trace-level analysis. Increase accuracy and precision by preventing loss of sensitive analytes even when using wool. Achieve lower detection limits for a wide range of active compounds. Ensure liner-to-liner reproducibility through consistent manufacturing and extensive testing. Restek Premium.0mm ID Straight Inlet Liner for Agilent GCs equipped with split/splitless inlets ID x OD x Length qty. cat.# Straight, Restek Premium Technology,.0mm x.mm x 8.mm ea...0mm x.mm x 8.mm -pk...0mm x.mm x 8.mm -pk.. Universal Y Press-Tight Connectors An alternative method of performing dual-column confirmational analyses! Split sample flow onto two columns perform confirmation analysis with a single injection. Split a single column flow to two detectors. Description ea. -pk. Universal Y Press-Tight Connector 00 00 Universal Y Press-Tight Connector, Deactivated 00-00- Universal Y Press-Tight Connector, Siltek Deactivated 08 08 Visit www.restek.com/liners for our full selection. Restek Electronic Leak Detector Don t let a small leak turn into a costly repair protect your analytical column by using a Restek leak detector. Leak Detector Specifications Detectable Gases: Helium, nitrogen, argon, carbon dioxide, hydrogen Battery: Rechargeable lithium ion internal battery pack ( hours normal operation) Operating Temperature Range: 0 F (0 8 C) Humidity Range: 0 9% Warranty: One year Certifications: CE, Ex, Japan Compliance: WEEE, RoHS Limits of Detection These gases can be detected with the Restek electronic leak detector at the following leak rates: Minimum Detectable Gas Limits and Indicating LED Color: Helium,.0 x 0 -, red LED Hydrogen*,.0 x 0 -, red LED Nitrogen,. x 0 -, yellow LED Argon,.0 x 0 -, yellow LED Carbon dioxide,.0 x 0 -, yellow LED Gas detection limits measured in atm cc/sec. Description qty. cat.# Leak Detector With Hard-Sided Carrying Case and Universal Charger Set (U.S., UK, European, Australian) ea. Small Probe Adaptor for Leak Detector ea. 8 Dynamic Duo Combo Pack (Restek Leak Detector and ProFLOW 000 Flowmeter) kit Soft-Sided Storage Case for Leak Detector or ProFLOW 000 Flowmeter ea. Avoid using liquid leak detectors on a GC! Liquids can be drawn into the system and/or into the leak detector. *Caution: The Restek electronic leak detector is designed to detect trace amounts of hydrogen in a noncombustible environment. It is NOT designed for determining leaks in a combustible environment. A combustible gas detector should be used for determining combustible gas leaks under any condition. When using it to detect hydrogen, the Restek electronic leak detector may only be used for determining trace amounts in a GC environment. Restek carries a full line of headspace essentials including screw-thread headspace vials & magnetic screw-thread caps! -8--00-800--88 www.restek.com

Restek Has Added ISO 0 and 0 Accreditations We Now Offer a Full Line of Certified Reference Materials! Restek is proud to announce that our reference standard manufacturing and QA testing labs in Bellefonte, PA, have earned ISO 0 and 0 accreditations through ALA. More than ever, you can rely on Restek for all of your reference standards, and now, you can also experience the advantages of our ISO accreditations: Satisfy regulatory requirements by sourcing CRMs from an accredited supplier. Benefit from the exceptional product quality and customer service needed to meet strict ISO 900, 0, and 0 guidelines. Get the same reliability and documentation with custom-formulated solutions as you do with stock standards both fall under Restek s accreditation. Consolidate orders by ordering primary- and secondary-source reference standards, GC and LC columns, sample prep supplies, and accessories from one vendor. We invite you to visit www.restek.com/iso to learn more about our ISO quality credentials and view our certificates (including scopes of accreditation). If you have any questions or would like more information, feel free to contact customer service at 8--00, ext., or csreps@restek.com Note: If your lab must use certified reference materials (CRMs), please be sure to tell your Restek representative when ordering so we can help you meet your regulatory requirements as we transition our inventory. Questions? Contact us or your local Restek representative (www.restek.com/contact-us). Restek patents and trademarks are the property of Restek Corporation. (See www.restek.com/patents-trademarks for full list.) Other trademarks in Restek literature or on its website are the property of their respective owners. Restek registered trademarks are registered in the U.S. and may also be registered in other countries. To unsubscribe from future Restek communications or to update your preferences, visit www.restek.com/subscribe To update your status with an authorized Restek distributor or instrument channel partner, please contact them directly. 0 Restek Corporation. All rights reserved. Printed in the U.S.A. www.restek.com Lit. Cat.# CFBR8-UNV