ISOCS / LabSOCS. Calibration software for Gamma Spectroscopy

Similar documents
Model S574 LabSOCS* Calibration Software. Radiation Safety. Amplified. DESCRIPTION KEY FEATURES.

Model S573 ISOCS* Calibration Software

Basic hands-on gamma calibration for low activity environmental levels

The Efficiency Characterization of Germanium Detectors at Energies less than 45 kev

Detection efficiency of a BEGe detector using the Monte Carlo method and a comparison to other calibration methods. Abstract

Practical Solutions to Radioactive Waste Characterization

Evaluation of Nondestructive Assay Characterization Methods for Pipe- Over-Pack Containers

Characterization of Large Structures & Components

Non-Destructive Assay Applications Using Temperature-Stabilized Large Volume CeBr Detectors 14277

Compton suppression spectrometry

PROFILE S and C Series

Quartz-Crystal Spectrometer for the Analysis of Plutonium K X-Rays

EFFICIENCY SIMULATION OF A HPGE DETECTOR FOR THE ENVIRONMENTAL RADIOACTIVITY LABORATORY/CDTN USING A MCNP-GAMMAVISION METHOD

Gamma Analyst Performance Characteristics (MDAs)

Collimated LaBr 3 detector response function in radioactivity analysis of nuclear waste drums

MARINELLI BEAKERS CATALOG

The first model was based only on the CANBERRA information which we. drawing. Canberra refused any other information.

Frazier L. Bronson CHP Canberra Industries, Inc., Meriden, CT USA ABSTRACT

Inaccuracy Determination in Mathematical Model of Labsocs Efficiency Calibration Program

Compton Camera. Compton Camera

Preparation of Standard Source as a Petri Dish for Plant by Using

Researchers at the University of Missouri-Columbia have designed a triple crystal

A MONTE CARLO SIMULATION OF COMPTON SUPPRESSION FOR NEUTRON ACTIVATION ANALYSIS. Joshua Frye Adviser Chris Grant 8/24/2012 ABSTRACT

The IAEA-CU world wide open proficiency test on the determination of radionuclides in soil, spinach and water

arxiv:nucl-ex/ v2 21 Jul 2005

Gamma-Spectrum Generator

NGN PhD Studentship Proposal

ISO INTERNATIONAL STANDARD

PRODUCTS FOR EDUCATION AND TRAINING

Journal of Radiation Protection and Research

Indian J.Sci.Res.2(3) :25-32, 2011

RMCC CANBERRA Latest developments

Simulation of 4π HPGe Compton-Suppression spectrometer

Performance of the True Coincidence Correction Method in GammaVision. Keyser, Ronald M., Haywood, Susan E., and Upp, Daniel L.

SOME ASPECTS OF MONTE CARLO SIMULATION FOR EFFICIENCY CALIBRATION OF GERMANIUM DETECTORS

Calibration of A Small Anode Germanium Well Detector

EFFICIENCY CALIBRATION STUDIES FOR GAMMA SPECTROMETRIC SYSTEMS: THE INFLUENCE OF DIFFERENT PARAMETERS

Geant4 Monte Carlo code application in photon interaction parameter of composite materials and comparison with XCOM and experimental data

An Improved U-Pu System for Field Pu Measurements

Project Memorandum. N N o. = e (ρx)(µ/ρ) (1)

Determination of the activity of radionuclides

Interactive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools

New methodology for source location and activity determination in preparation of repairing or decommissioning activities

1 Introduction. 2 Method. Robert Metzger 1,*, Kenneth Van Riper 2, and George Lasche 3

ANGLE 4. Advanced Gamma Spectroscopy Efficiency Calibration Software

Radioactive Waste Management

PRACTICAL GAMMA SPECTROSCOPY ASSAY TECHNIQUES FOR LARGE VOLUME LOW-LEVEL WASTE BOXES

University of Montenegro Centre for Nuclear Competence and Knowledge Management Podgorica,, Montenegro

Depth Distribution of H-3, C-14 and Co-60 in Decommissioning of the Biological Shielding Concrete of KRR-2

New happenings in gamma spectroscopy data analysis Sylvie Ward Sales Support Specialist

Geometric Considerations in the

WM2012 Conference, February 26 March 1, 2012, Phoenix, Arizona, USA. Segmented Gamma Scanner for Small Containers of Uranium Processing Waste

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

QuantumMCA QuantumNaI QuantumGe QuantumGold

1220 QUANTULUS The Ultra Low Level Liquid Scintillation Spectrometer

PROFILE S and C Series P-type Semi-planar and Coaxial HPGe Detectors

FRAM V5.2. Plutonium and Uranium Isotopic Analysis Software

Introduction to Environmental Measurement Techniques Radioactivity. Dana Pittauer 1of 48

Establishing an ISO-CART Measurement Station to Meet Government Burial Regulations for Radioactive Material

QSM 5.1 FAQs. For a test with a recommended maximum holding time measured in hours, the holding time shall be tracked by the hour.

WIPP WAC Equivalence Support Measurements for Low-Level Sludge Waste at Los Alamos National Laboratory

EFFICIENCY AND RESOLUTION OF GERMANIUM DETECTORS AS A FUNCTION OF ENERGY AND INCIDENT GEOMETRY

K 40 activity and Detector Efficiency

Introduction to gamma spectroscopy on a budget. Daniel Emes SA Radiation

Detection and measurement of gamma-radiation by gammaspectroscopy

Semiconductor Detector

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA

DETERMINATION OF CORRECTION FACTORS RELATED TO THE MANGANESE SULPHATE BATH TECHNIQUE

Distance from the face of the detector to the surface of the item being measured.

Radiation Detection and Measurement

THE COMPTON EFFECT Last Revised: January 5, 2007

Characterizing New Multi-Channel Peak Sensing ADC-Mesytec MADC-32

Investigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the WBC

Characterization and Monte Carlo simulations for a CLYC detector

Digital simulation of neutron and gamma measurement devices

Sample Spectroscopy System Hardware

THE ACTIVITY CALIBRATOR

IN-LINE MONITORING OF RADIUM SLURRY BY GAMMA-RAY SPECTROMETRY

Comparison of the Photo-peak Efficiencies between the Experimental Data of 137 Cs Radioactive Source with Monte Carlo (MC) Simulation Data

Enriched Uranium Waste Assay at AWE

Investigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the UAL

IAEA-SM-367/10/04/P SCREENING AND RADIOMETRIC MEASUREMENT OF ENVIRONMENTAL SWIPE SAMPLES

Integrated Waste Assay System (IWAS)

ETNA (Efficiency Transfer for Nuclide Activity measurement)

ISO INTERNATIONAL STANDARD. Measurement of radioactivity in the environment Soil Part 3: Measurement of gamma-emitting radionuclides

The Best Gamma-Ray Detector

High-Performance Germanium Coaxial Detectors for Safeguards and Non-Destructive Assay Product Configuration Guide

Radiometric Measurements of Environmental Radioactivity

High Purity Germanium Detector Calibration at ISOLDE

Procedure for determining radionuclides in foodstuffs at elevated levels of contamination by gamma spectrometry

Gamma background measurements in the Boulby Underground Laboratory

Dependence Of Gamma Ray Attenuation On Concentration Of Manganese (II) Chloride Solution

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

IPNDV Working Group 3: Technical Challenges and Solutions Nuclear Material (3) Technology Data Sheet

Slides by: Prof. Abeer Alharbi

European Project Metrology for Radioactive Waste Management

Scintillation Detector

FoodScreen Radiological Food Screening System

Transcription:

ISOCS / LabSOCS Calibration software for Gamma Spectroscopy

Counts Setup Hardware Peak Shaping Parameters Rise Time Flat Top Pole-zero Number of Channels Signal Gain Setting up a detector for measurement Setup Software Energy Calibration Shape Calibration Efficiency Calibration 1,E+06 1,E+04 1,E+02 Select Sources Energy Range Half-life Cascade effects Activity Select Geometries Beakers Vials Pay $$$ for these sources 137 Cs 65 Zn 133 Ba 60 Co 241 Am 57 Co 152 Eu 1,E+00 0 4000 8000 12000 16000 Channel February 2014 ISOCS/LabSOCS M.Rotty - p.2

Source-based Efficiency Calibrations Cost of Source-based Calibration Purchase of Sources Replacement of Sources Disposal of Sources Licensing for Sources Calibration Program Sample Preparation What if you can t make the sample match the calibration Not enough material Unusual material composition Locked in sealed container Calibration Sample? = Measured Sample February 2014 ISOCS/LabSOCS M.Rotty - p.3

cm 2 / g Gamma-ray Interactions in Material Gamma-ray Interactions are very well understood. Photoelectric absorption Compton Scattering Pair Production 1E+04 1E+03 1E+02 1E+01 1E+00 1E-01 1E-02 Energy dependence of gamma ray interaction in Germanium 1E-03 1E-03 1E-02 1E-01 1E+00 1E+01 1E+02 1E+03 Energy [MeV] Coherent Scattering Incoherent Scattering Photo-electric absorption Pair Production - Nuclear Total - w/ coherent Total - w/o coherent We can exploit this knowledge to create efficiency responses based on the physical parameters of the geometry. Use mathematical models to accurately compute the transport of gamma-rays through these geometries. February 2014 ISOCS/LabSOCS M.Rotty - p.4

Field (In-Situ) measurements February 2014 ISOCS/LabSOCS M.Rotty - p.5

Modeling of Laboratory Samples How to handle varieties of samples and containers? February 2014 ISOCS/LabSOCS M.Rotty - p.6

ISOCS/LabSOCS: A Generalized Efficiency Computation Method ISOCS/LabSOCS method is designed to quickly and accurately compute efficiencies for a wide range of geometries. Relies on a factory characterization of the intrinsic efficiency response of the detector. Does not require that the customer have a large inventory of calibration sources (although nominal sources for quality control tracking is highly recommended). February 2014 ISOCS/LabSOCS M.Rotty - p.7

Regulatory Acceptance of Modeling Approaches Calibration of Germanium Detectors for In-Situ Gamma-ray Measurements, N42.28-2002 American National Standards Institute, Inc., 1430 Broadway, New York 10018. One such application [of Monte Carlo Methods] is the calculation of the efficiency or response function for an HPGe detector. Using this approach, detectors can be calibrated for a variety of applications using models and simulations. Measuring, Evaluating, and Reporting Radioactive Material in Liquid and Gaseous Effluents and Solid Waste, U.S. Nuclear Regulatory Commission Guide 1.21 rev. 2 (June 2009): The use of NIST-traceable sources combined with mathematical efficiency calibrations may be applied to instrumentation used for radiochemical analysis (e.g., gamma spectroscopy systems) if employing a method provided by the instrument manufacturer. A Good Practice Guide for the use of Modelling Codes in Non Destructive Assay of Nuclear Materials, ESARDA Bulletin No. 42 (November 2009) 26. [Proposed revision of N42.14-1999. In committee] Calibration and Use of Germanium Spectrometers for the Measurement of Gamma-Ray Emission Rates of Radionuclides, N42.14-201x American National Standards Institute, Inc., 1430 Broadway, New York 10018: The following approaches may be considered for the calibration of the detector efficiency: a) Measurement of a standardization coefficient for a specific gamma ray and radionuclide by direct comparison with a standard source of known activity; b) Measurement of the full-energy peak efficiency as a function of energy; c) Calculation of the peak efficiency as a function of energy with the use of Monte Carlo or other calculation techniques. February 2014 ISOCS/LabSOCS M.Rotty - p.8

Flexibility of Modeling With modeling, it is possible to rapidly produce geometries that represent many usual shapes for which source standards may not be readily available. 55 gallon drum Gas Cell 400 ml Beaker Marinelli Beakers Large Tank (note collimated offset detector) Wine Glass Flask (with absorbers) February 2014 ISOCS/LabSOCS M.Rotty - p.9

Include Features Beyond just the Sample Complex objects can be created including absorber materials such as spacers, collimators, and positioning rings. February 2014 ISOCS/LabSOCS M.Rotty - p.10

A Word of Caution While mathematical modeling is a significant time and cost saver compared to source-based calibrations, care must still be taken to model the geometry to an appropriately accurate level. Not all regions are equally important. Some critical parameters are: Distance from Sample to Detector Attenuation of gamma-rays by intervening materials Not Important! Very Important! Detector February 2014 ISOCS/LabSOCS M.Rotty - p.11

Efficiency (relative to 3 mm distance) Sensitivity of Distance The efficiency for sources close to the detector are very sensitive to the position of the source. Beaker Bottom As a general rule of thumb: 1 mm 5% change in efficiency for close geometries. Many beakers have complicated bases and an effective distance may not be clear. 1.10 6 mm Detector Endcap 60 mm diameter disk source Also note: Reference source standards in epoxy matrices may deform beaker (from Rxn heat) thus changing the geometry. 1.05 1.00 60 kev 1332 kev Direct modeling of beaker base provides accurate description of the container. 0.95 0.90 0 1 2 3 4 5 6 February 2014 ISOCS/LabSOCS M.Rotty - p.12 Distance from Endcap (mm)

3D Interactive Geometry Composer Powerful 3D visualization provides immediate feedback for faster geometry development Detectors, basic Collimators, and Templates are rendered in the 3D virtual space. Data entry is fundamentally similar to the present geometry composer (although not identical). February 2014 ISOCS/LabSOCS M.Rotty - p.13

Templates - sample shape Many standard sample geometries are available for LabSOCS Box, Cylinder, Sphere, Beaker, Marinelly beaker Beaker editor for complex shape (cylindrically symmetric) Many templates are also available for ISOCS Drum, Container, Pipe, Box, surface measurement With collimator, housing, or without February 2014 ISOCS/LabSOCS M.Rotty - p.14

Material editor Easy to create: New element List of currently used elements February 2014 ISOCS/LabSOCS M.Rotty - p.15

LabSOCS Beaker Editor Used to create the *.bkr files for the complex beaker template in LabSOCS Simplifies creating of the complex beaker geometries by providing a visual output Created geometry may consist of boundaries for different materials, shields and collimators with a variety of shapes Beaker View Window Beaker Edit Window February 2014 ISOCS/LabSOCS M.Rotty - p.16

Geometry report ISOCS / LabSOCS report All geometry parameters Dimensions Materials Draw Template used Final result February 2014 ISOCS/LabSOCS M.Rotty - p.17

ISOCS - LabSOCS Create an efficiency curve to calculate activities Create a geometry file This file can be used to create a new geometry Dimensions modification Materials modification Can be used to cascade summing correction February 2014 ISOCS/LabSOCS M.Rotty - p.18

Absolute Efficiency Absolute Efficiency Typical: 80 mm (diam) 100 mm (tall) Modeling for Sample Optimization Cylindrical sample with 500 cc of 1.6 g/cc Soil. Ran multiple efficiency computations with varying container diameter and height but with fixed sample volume. Determine maximum efficiency. All detectors have maximum efficiency when sample diameter is about 12 14 cm, regardless of energy. In all cases a high aspect ratio (e.g. BEGe s) detector has greater efficiency than a low aspect ratio detector of similar relative efficiency. 5.E-02 HiAR (D/L: 2.7) MedAR (D/L:1.4) LoAR (D/L: 0.75) 60 kev 1.E-02 1332 kev 4.E-02 1.E-02 Optimum: 120 mm (diam) 45 mm (tall) 3.E-02 Fixed Sample Volume: 500 cc 2.E-02 80 100 120 140 160 180 Sample Diameter (mm) 8.E-03 6.E-03 HiAR (D/L: 2.7) MedAR (D/L:1.4) LoAR (D/L: 0.75) Fixed Sample Volume: 500 cc 80 100 120 140 160 180 Sample Diameter (mm) February 2014 ISOCS/LabSOCS M.Rotty - p.19

How Certain is your Measurement? If you don t know all the parameters of your measurement, it is possible to use modeling techniques to estimate the uncertainty due to these not well known parameters. Canberra provides an ISOCS interface called the ISOCS Uncertainty Estimator (IUE) to estimate these uncertainties The IUE software Helps the user determine which parameters to concentrate his effort in accurately determining efficiency A structured and defendable method to quickly create the uncertainty of the efficiency calibration, and to propagate those errors to the final result A useful investigative tool to evaluate, optimize and choose between various counting choices Different analysis modes: Sensitivity Analysis: Determine which geometrical parameters are most important to know well (focus effort on minimization of uncertainties of important variables) Uncertainty Analysis: Put in all known geometrical uncertainties and analyzed to determine the Total Geometric Uncertainties (more reliable accountancy) CANBERRA CANBERRA February 2014 ISOCS/LabSOCS M.Rotty - p.20

Summary Source-Based Efficiency Expensive Purchase sources/licensing Limited Few Number of Geometries Labor Intensive Make Samples Match the Calibration Mathematical Efficiency Take Advantage of the Well-known Properties of Gamma-ray Physics Generally Applicable In-Situ Non-destructive Assay Laboratory Defendable Results are reproducible Complex corrections -- Cascade Summing Uncertainty Modeling Measurement Optimization Focus on Making the Calibration Match the Sample Mathematical Efficiency modeling not only saves time, but it gives a deeper understanding of the measurement and greater confidence in the results. February 2014 ISOCS/LabSOCS M.Rotty - p.21