Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Similar documents
Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Column Dimensions. GC Columns and Consumables. Mark Sinnott Application Engineer. March 12, 2010

Secrets of GC Column Dimensions

Rapid Analysis of Food and Fragrances Using High-Efficiency Capillary GC Columns. Application. Authors. Abstract. Introduction

GC Resolution Do You See What I See?

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Selection of a Capillary

Selection of a Capillary GC Column

Introduction to Capillary GC

Practical Fast Gas Chromatography for Contract Laboratory Program Pesticide Analyses *

Understanding Gas Chromatography

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Author. Abstract. Introduction

A New Web-Based Application for Modeling Gas Chromatographic Separations. Dr. Hansjoerg Majer Restek Corporation Market Development Manager Europe

Understanding the Capillary GC Column: How to Choose the Correct Type and Dimension

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography

Introduction to Capillary GC

A New Web-Based Application for Modeling Gas Chromatographic Separations

Choosing the Correct GC Column Dimensions and Stationary Phase

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

How To Select the Correct GC Column. Simon Jones Application Engineer

New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column

Water Injections in GC - Does Water Cause Bleed?

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Theory and Instrumentation of GC. Chromatographic Parameters

The Focus Robotic Sample Processor as a Tool for the Multiple Analysis of Samples using Complementary Techniques

Introduction and Principles of Gas Chromatography

Hydrogen as a Carrier Gas in the Analysis of Polar/Non-Polar Compounds Using the Polyarc System. Application Note. Author. Introduction.

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application

Fast and Accurate Analysis of PBDEs in a Single Run, Including BDE-209

Fast and Accurate Analysis of PBDEs in a Single Run, Including

Study of Residual Solvents in Various Matrices by Static Headspace

GAS CHROMATOGRAPHY (GC)

The Effects of Carrier Gas Viscosity and Diffusion on Column Efficiency in Capillary Gas Chromatography

So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Chromatographic Separation

Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions

A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column

Application. Gas Chromatography February Introduction

Get Selective. By Jaap de Zeeuw

Gas Chromatography (Chapter 2 and 3 in The essence of chromatography)

Analysis of BTEX in Natural Water with SPME

Ultra-Inert chemistry for Trace Level Analysis

Supelco Ionic Liquid GC Columns Introduction to the Technology

Volatile organic compounds (VOCs):

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

Trajan SGE GC Columns

CHEM340 Tutorial 4: Chromatography

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

Fast Analysis of USP 467 Residual Solvents using the Agilent 7890A GC and Low Thermal Mass (LTM) System

TOTALLY INNOVATIVE MULTIMODE AUTOSAMPLER NEW KONIK ROBOKROM Laboratory Gas Generators An Overview +8 OPERATIONAL MODES MAIN FEATURES

Principles of Gas- Chromatography (GC)

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

Spectra Library Electron Capture Negative Ion (ECNI) Mass Spectra of Selected Polybrominated Diphenyl Ethers (PBDEs)

Simultaneous Compound Identification and Quantification with Parallel Polyarc /FID and MS

Column Selection. there is more to life than a boiling point column. Jaap de Zeeuw Restek Corporation, The Netherlands. Copyrights: Restek Corporation

2. a) R N and L N so R L or L R 2.

Highly Sensitive and Rugged GC/MS/MS Tool

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

Evaluation of a New Analytical Trap for Gasoline Range Organics Analysis

Simultaneous dual capillary column headspace GC with flame ionization confirmation and quantification according to USP <467> Application Note

Spring 2010 updated March 24 Determination of Aromatics in Gasoline by Gas Chromatography- Mass Spectrometry: Comparison of Grades and Brands

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Evaluation of Capillary Columns for General Performance Parameters

Speakers. Moderator. John V Hinshaw GC Dept. Dean CHROMacademy. Tony Taylor Technical Director CHROMacademy. Dave Walsh Editor In Chief LCGC Magazine

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY

STANDARD OPERATING PROCEDURES

GC-CI-MS analysis of TMS derivatives

Gas chromatography. Advantages of GC. Disadvantages of GC

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

Chemistry Instrumental Analysis Lecture 27. Chem 4631

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

Analytical Chemistry

Application Note 116 Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ

Exercise in gas chromatography

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

Fall 2012 Due In Class Friday, Oct. 19. Complete the following on separate paper. Show your work and clearly identify your answers.

Chromatography. Gas Chromatography

Chlorinated Compounds in Hydrocarbon Streams Using a Halogen Specific Detector (XSD)

Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs)

Headspace Technology for GC and GC/MS: Features, benefits & applications

CHAPTER 6 GAS CHROMATOGRAPHY

Chapter 31 Gas Chromatography. Carrier Gas System

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note.

Residual solvents analysis using an Agilent Intuvo 9000 GC system

USP<467> residual solvents

A Direct 5 ms Column Performance Comparison for Active Semi-Volatile Analytes

2] The plate height in chromatography is best described as 2

Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application

Continuous Improvement in Petroleum/Petrochemical Analysis HP s Family of Innovative PLOT Columns

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

U.S. EPA Method 8270 for multicomponent analyte determination

Determination of Volatile Substances Proof of Food Adulteration

Transcription:

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software High Efficiency GC Columns Page 1 Variables for Shortening Run Times Stationary Phase Shorten Column Length Decrease Internal Diameter Temperature Programming Carrier Gas: type and linear velocity Page 2 1

Resolution N k R s = α 1 4 k + 1 α Efficiency Retention Selectivity N = ƒ (gas, L, r c ) k = ƒ (T, d f, r c ) α = ƒ (T, phase) L = Length r c = column radius d f = film thickness T = temperature Page 3 Start with the Right Phase DB-1 15m x 0.32mm, 0.25µm Oven: 40 C for 2 min 40-120 C at 5 C/min 0 2 4 6 8 10 12 14 Time (min.) DB-Wax 15m, 0.32mm, 0.25µm Oven: 80-190 C at 20 C/min 0 1 2 3 4 5 Time (min.) Page 4 2

Resolution N k R s = α 1 4 k + 1 α Efficiency Retention Selectivity N = ƒ (gas, L, r c ) k = ƒ (T, d f, r c ) α = ƒ (T, phase) L = Length r c = column radius d f = film thickness T = temperature Page 5 Column Length and Efficiency (Theoretical Plates) Length (m) n 15 69,450 30 138,900 60 277,800 0.25 mm ID n/m = 4630 (for k = 5) Page 6 3

Column Length and Resolution R α n α L Length X 4 = Resolution X 2 t α L Page 7 Column Length VS Resolution and Retention: Isothermal R=0.84 2.29 min R=1.16 4.82 min R=1.68 8.73 min 15 m 30 m 60 m Double the plates, double the time but not double the the resolution Page 8 4

DECREASE THE LENGTH DB-5 30 m 0.53 mm I.D., 0.5 µm 1 2 3 4 5.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 DB-5 15 m 0.53 mm I.D., 0.5 µm 1. Benzene 2. Toluene 3. Ethylbenzene 4. m,p-xylene 5. o-xylene 1 2 3 4 5 1.0 2.0 3.0 4.0 5.0 BTEX Carrier: Helium, 36 cm/sec at 40 c Oven : 40 C for 3 min, 5 /min to 100 C 6.0 Page 9 Column Length and Cost 15m 30m 60m $ $ $ $ $ $ $ Page 10 5

Length Summary If you Decrease Length: Efficiency Decrease Resolution Decrease Analysis Time Decrease Pressure Decrease Cost Decrease Page 11 Resolution N k R s = α 1 4 k + 1 α Efficiency Retention Selectivity N = ƒ (gas, L, r c ) k = ƒ (T, d f, r c ) α = ƒ (T, phase) L = Length r c = column radius d f = film thickness T = temperature Page 12 6

Column Diameter - Theoretical Efficiency 5 m 10 m Total Plates N ~ 112,000 N ~ 112,000 I.D. (mm) 0.05 0.10 0.18 20 m N ~ 112,000 0.20 0.25 n/m 23,160 11,580 6,660 5830 4630 30 m N ~ 112,000 0.32 3660 0.45 2840 k = 5 0.53 2060 Page 13 Different Column I. D. Equal Phase Ratios Column: DB-624 30 m, 0.53 mm, 3 m Carrier: Helium, 40(cm/sec) Oven: 65 C Injection: Split Detector: FID Column: DB-624 30 m, 0.32 mm, 1.8 m 0 5 10 15 20 Time (min) Page 14 7

PHASE RATIO (β) Film Thickness Column Dimensions Phase Ratio β 30 m x.53 mm x 3.0 µm 44 30 m x.32 mm x 1.8 µm 44 K C = k β β = r 2d f Page 15 Column Diameter and Capacity I.D. (mm) Capacity (ng) 0.05 1-2 0.10 6-13 0.18 25-55 Like Polarity Phase/Solute 0.25 µm film thickness 0.20 35-70 0.25 80-160 0.32 110-220 0.45 600-800 0.53 1000-2000 Page 16 8

Diameter Summary If you decrease the inside diameter: Efficiency Increase Resolution Increase Pressure Increase Capacity Decrease Flow rate Decrease Page 17 Combining a change in Length with a change in Diameter Decrease Length Decrease Diameter Efficiency Analysis Time Page 18 9

Resolution N k R s = α 1 4 k + 1 α Efficiency Retention Selectivity N = ƒ (gas, L, r c ) k = ƒ (T, d f, r c ) α = ƒ (T, phase) L = Length r c = column radius d f = film thickness T = temperature Page 19 Carrier Gas Considerations Best velocity? Optimal range of velocities Too low or high results in loss of resolution Balance resolution and analysis time BUT... there is no LAW against going FASTER Page 20 10

Carrier Gas Considerations Van Deemter Curve 1.00 Excessive Diffusion h 0.75 0.50 He Poor Mass Transfer 0.25 ū opt H 2 OPGV 10 20 30 40 50 60 u (cm/sec) Page 21 Carrier Gas - Hydrogen Comments Hydrogen is extremely diffusive in air Difficult to reach explosive level of ~4 % Most GC's flow regulated with safety shutdown Spring loaded/explosion proof doors Page 22 11

Carrier Gas Considerations Utilizing Computer Controlled Flow Ramping (EPC) Lonely Late Eluters? = P Decrease retention and overall run time by increasing pressure (speed up the gas!) Page 23 Easy Options with Method Translation Software Different Column Dimensions Switch He to H 2 Carrier Gas and Try Faster Velocities Same Column & Gas Type but Faster Velocities Combination of all of the above Page 24 12

CLP-Pesticides - Original Improved Method 0.32mm I.D., Helium Carrier Gas 1 2 GC3-6707.D\ECD2B 3 4 5,6 7 8 10 9 11 12 13 Column: DB-XLB 30m x 0.32mm i.d., 0.25µm Carrier: He, constant flow, 38 cm/s at 120 C Injector: Pulsed Splittless, 220 C Pulse pressure & time: 35psi for 1.15min 2µL, 50ppb Oven: 120 C for 1.17min 120 C to 160 C at 25 /min 160 C to 260 C at 10 /min 260 C to 300 C (4min) at 15 /min Detector: µ-ecd, 320 C Ar/CH4 (P5) makeup gas at 60mL/min 15 14 16 17 18 19 21 <16 minutes 22 20 6.00 8.00 10.00 12.00 14.00 16.00 Page 25 Input Original Method Parameters Page 26 13

Same Column and Gas Type Fast Analysis (OPGV) Transfer same dimensions New Velocity New Temp. Program Page 27 GC3-6707.D\ECD2B Same Column and Gas Type Fast Analysis (OPGV) Before No Real Changes in Resolution! 6.00 8.00 10.00 12.00 14.00 16.00 Only Time! <14 minutes Page 28 14

GC3-6707.D\ECD2B 6.00 8.00 10.00 12.00 14.00 16.00 Same Column and Gas type None mode, Try higher velocities New calculated temp. program Page 29 Same Column and Gas type None mode, Higher velocities Before Co-elution (poorer) 80 cm/sec Co-elution (poorer) <8 minutes 65 cm/sec <10 minutes Close elution (similar) 50 cm/sec Page 30 15

Same Column, Hydrogen Carrier Gas Translate Only Page 31 GC3-6707.D\ECD2B Same Column, H 2 Carrier Gas Translate Only Before No Real Changes in Resolution 6.00 8.00 10.00 12.00 14.00 16.00 33% faster! 11 minutes Page 32 16

GC3-6707.D\ECD2B 6.00 8.00 10.00 12.00 14.00 16.00 Same Column, H2 Carrier Gas, Higher Velocities Page 33 Same Column, H2 Carrier Gas, Even Higher Velocities Co-elution Before 85 cm/sec Co-elution 7 minutes 80 cm/sec Co-elution <8 minutes 70 cm/sec Page 34 17

New Column Dimensions, H 2 Gas, Translate Only Input NEW dimensions Close enough (got lucky) New Velocity New Temp. Program Page 35 New Column Dimensions, H2 Gas, Translate Only Page 36 18

New Column Dimensions, H2 Gas, Translate Only 5 10 11 6 Page 37 New Column Dimensions, H2 Gas, Fast Analysis New Velocity New Temp. Program Page 38 19

New Column Dimensions, H2 Gas, Fast Analysis Better Resolution and Faster Analysis! 503.003.504.004.505.005.506.006.507.00 Page 39 New Column Dimensions, H2 Gas, Higher Velocities Page 40 20

New Column Dimensions, H2 Gas, Higher Velocities 105 cm/sec? 5.5 minutes! 95 cm/sec <6 minutes 85 cm/sec Page 41 Flow Ramp (EPC) for Late Eluters and Faster Bake Outs Page 42 21

Flow Ramp No Flow Ramp Begin of Flow Ramp Under 5 minutes! Page 43 Final Method Used at EPA 1 2 3 4 5 6 7 8 Column: DB-XLB 20m x 0.18mm i.d., 0.18µm Carrier: H2, constant flow, 77.3cm/s at 120 C Injector: Pulsed Splittless, 220 C Pulse pressure & time: 35psi for 0.5min Flow ramp at 6.25min of 99mL/min 2 to 3mL/min 2mm i.d. liner 0.5µL, 50ppb Oven: 120 C for 0.49min 120 C to 160 C at 59.4 /min 12 160 C to 260 C at 23.7 /min 10 260 C to 300 C (1.69min) at 35.6 /min 9 Detector: µ-ecd, 320 C 13 Ar/CH4 (P5) makeup gas at 60mL/min 21 11 14 15 16 17 18 19 20 22 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 Page 44 22

Final Method Used at EPA 1 2 3 4 5 6 7 8 12 10 9 13 11 DB-XLB 14 15 16 17 18 19 20 21 22 0 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 1 2 3 4 6 5 7 8 9 10 12 13 11 DB-17ms 14 16 15 1718 19 20 21 22 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 Page 45 Further Work (App. Note 5989-7818EN) 20m x 0.18mm ID, Fast Even in Helium Page 46 23

Translate Only, Helium 20 22 1 DB-XLB 2 3 5 6 7 12 13 16 18 19 10 8 9 11 15 14 17 21 4 20 22 DB-17ms 1 12 13 16 19 21 15 17 18 2 3 4 6 5 7 8 9 10 11 14 12 minutes 4 6 8 10 12 Page 47 Food/Fragrance Method translation Page 48 24

Spearmint Oil on DB-1 17.7 min -9.7 min 0.18 mm, He Carrier 0.25 mm, He Carrier 27.4 min 3 8 13 18 23 28 Time (min) Page 49 Food/Fragrance Method translation, Hydrogen Page 50 25

Spearmint Oil on DB-1, (App. Note 5989-7509EN) 10.6 min -16.8 min 0.18 mm, H 2 Carrier 17.7 min -9.7 min 0.18 mm, He Carrier 0.25 mm, He Carrier 27.4 min 3 8 13 18 23 28 Time (min) Page 51 Spearmint Oil on DB-1 Resolution Check -16.8 min (0.18 mm, H 2 Carrier) 10.6 min -9.7 min (0.18 mm, He carrier) 17.7 min (0.25 mm, He Carrier) 27.4 min Page 52 26

Resolution Maintained Compounds Sabinene β-pinene α-terpinene p-cymene Speed Gain Compound Resolution 0.25 mm 0.18 mm Helium Helium 1.52 1.59 1.61 1.73 N/A 35% 0.18 mm Hydrogen 1.56 1.86 61% Page 53 Aromatic Solvents on HP-INNOWax Page 54 27

Aromatic Solvents on HP-INNOWax 20m x 0.18mm ID x 0.18um 4.6 min 1 1.5 2 2.5 3 3.5 4 4.5 min 60m x 0.32mm ID x 0.5um 22.6 min 5 7.5 10 12.5 15 17.5 20 22.5 Page 55 Aromatic Solvents on HP-INNOWax Modified Temp then converted to Hydrogen Page 56 28

Aromatic Solvents on HP-INNOWax (App. Note 5989-7623EN) 20m x 0.18mm ID x 0.18um Helium 4.6 min 1 1.5 2 2.5 3 3.5 4 4.5 min Hydrogen 3 min Page 57 CONCLUSIONS Stationary Phase Chosen for optimized selectivity Length Shorter might be possible without losing a lot of R Carrier Gas Helium can still go fast but Hydrogen has the most advantage at high velocities Flow Ramp Increase at end of run for lonely late eluters Temperature Program Use MTS to scale temps properly Method Translation Software FREE, reliable Diameter Smaller allows shorter length but has less capacity Small Change in ID Easier to Translate Again think capacity Page 58 29

TECHNICAL SUPPORT 1-800-227-9770, #4, #1 E-mail: gc_column_support@agilent.com 1-972-699-6423 (Daron) 1-866-912-6701 (toll free) E-mail: Daron_Decker@Agilent.com Page 59 For More Detailed Information Fast Analysis if Aromatic Solvent with 0.18 mm ID GC Column" (5989-7623EN) Analysis of Semivolatiles Using High Efficiency Capillary GC Columns (5989-7500EN) Rapid Analysis of Food and Fragrances Using High-Efficiency Capillary GC Columns (5989-7509EN) Agilent J&W High-Efficiency Capillary columns: Productivity- Enhancing Tools for Fast GC Applications (5989-7499EN) www.agilent.com/chem/hecolumns Page 60 30