Estimation of Seismic Shutoff of Intelligent Gas Meters in the Tokyo Metropolitan Area

Similar documents
Figure Locations of the CWB free-field strong motion stations, the epicenter, and the surface fault of the 1999 Chi-Chi, Taiwan earthquake.

Estimation of Damage Ratios of Wooden Houses and Water Distribution Pipelines in an Earthquake Scenario for the Tokyo Metropolitan Region

EVALUATION OF SITE AMPLIFICATIONS IN JAPAN USING SEISMIC MOTION RECORDS AND A GEOMORPHOLOGIC MAP

Department of Urban Environment Systems, Chiba University, Japan. Kajima Technical Research Institute, Kajima Corporation Co., Ltd., Japan.

Special feature: Are its lessons being adequately applied? Follow-up on the ten-year anniversary of the Hanshin-Awaji Earthquake

REAL-TIME ASSESSMENT OF EARTHQUAKE DISASTER IN YOKOHAMA BASED ON DENSE STRONG-MOTION NETWORK

Estimation of Deep Shear-Wave Velocity Profiles in Lima, Peru, Using Seismometers Arrays

Correlation of JMA instrumental seismic intensity with strong motion parameters

Experiments of Earthquake Early Warning to Expressway Drivers using Plural Driving Simulators

RELATIONSHIP BETWEEN DAMAGE RATIO OF EXPRESSWAY EMBANKMENT AND SEISMIC INTENSITY IN THE 2004 MID-NIIGATA EARTHQUAKE

Department of Civil Engineering, Kyoto University, by Shunzo OKAMOTO, M. J. A., Sept.

PRELIMINARY STUDY OF GROUND MOTION CHARACTERISTICS IN FURUKAWA DISTRICT, JAPAN, BASED ON VERY DENSE SEISMIC-ARRAY-OBSERVATION

PROBABILITY-BASED DESIGN EARTHQUAKE LOAD CONSIDERING ACTIVE FAULT

RELATIONSHIP OF SEISMIC RESPONSES AND STRENGTH INDEXES OF GROUND MOTIONS FOR NPP STRUCTURES

To estimate damage ratios of water and gas distribution pipes, fragility curves were empirically obtained based on damage datasets after the 1995 Kobe

Uncertainty in the assessment of seismic hazard

SEISMIC RISK ANALYSIS FOR CITY GAS NETWORK IN SOUTHERN KANTO AREA, JAPAN ABSTRACT

STUDIES ON SEVARAL COUNTERMEASURES AGAINST LIQUEFACTION-INDUCED FLOW AND AN APPLIVATION OF A MEASURE TO EXISTING BRIDGES IN TOKYO

CHARACTERISTICS OF STRONG GROUND MOTION FROM THE 2011 GIGANTIC TOHOKU, JAPAN EARTHQUAKE

Journal of Earthquake and Tsunami, Vol. 3, No. 4 (2009)

Study of the liquefaction phenomenon due to an earthquake: case study of Urayasu city

NATIONWIDE SITE AMPLIFICATION ZONATION STUDY USING JAPAN ENGINEERING GEOMORPHOLOGIC CLASSIFICATION MAP

- Information before strong ground motion -

PROBABILISTIC SEISMIC HAZARD MAPS AT GROUND SURFACE IN JAPAN BASED ON SITE EFFECTS ESTIMATED FROM OBSERVED STRONG-MOTION RECORDS

STRONG GROUND MOTION ATTENUATION IN THE SEA OF JAPAN (OKHOTSK-AMUR PLATES BOUNDARY) REGION

Effects of Surface Geology on Seismic Motion

(c) (a) (b) EFFECTS OF LOCAL SITE AMPLIFICATION ON DAMAGE TO WOODEN HOUSES

PREDICTION OF AVERAGE SHEAR-WAVE VELOCITY FOR GROUND SHAKING MAPPING USING THE DIGITAL NATIONAL LAND INFORMATION OF JAPAN

Making the Original Earthquake Early Warning System including epicentral earthquake

Study on acceleration response spectra for seismic design based on observed records in Hokkaido, JAPAN

SIMPLIFIED METHOD IN EVALUATING LIQUEFACTION OCCURRENCE AGAINST HUGE OCEAN TRENCH EARTHQUAKE

Probability Distribution of Falling Rock by Experiments and a Method to Assess Collision Hazard

Preliminary Analysis for Characteristics of Strong Ground Motion from Gigantic Earthquakes

REPORT ON THE TOHOKU AREA PASIFIC OFFSHORE EARTHQUAKE

JMA Tsunami Warning Services. Tomoaki OZAKI Senior Coordinator for Tsunami Forecast Modeling Japan Meteorological Agency

Design of Safety Monitoring and Early Warning System for Buried Pipeline Crossing Fault

A NUMERICAL STUDY OF DYNAMIC BEHAVIOR OF A SELF-SUPPORTED SHEET PILE WALL

Development of Spatial Information Database of Building Damage and Tsunami Inundation Areas following the 2010 Chile Earthquake

A STUDY AND DEVELOPMENT OF SEMI-ACTIVE CONTROL METHOD BY MAGNETORHEOLOGICAL FLUID DAMPER IN BASE ISOLATED STRUCTURES

SHAKING TABLE TESTS ON SEISMIC RESPONSE REDUCTION EFFECTS OF ROCKING BUILDING STRUCTURAL SYSTEMS

Frequency-dependent Strong Motion Duration Using Total Threshold Intervals of Velocity Response Envelope

Preliminary report of the 2011 off the Pacific coast of Tohoku Earthquake *


Final Presentation on Disaster Risk Management in Japan. Through ADRC V. R Programme. Main Findings and Action Plan:

SITE EFFECTS IN HIROSHIMA PREFECTURE, JAPAN DURING THE 2001 GEIYO EARTHQUAKE OF MARCH 24, 2001

Y. Shioi 1, Y. Hashizume 2 and H. Fukada 3

Experiments of Earthquake Early Warning to Expressway Drivers Using Synchronized Driving Simulators

Field Investigation and Dynamic Analysis of Damaged Structure on Pile Foundation during the 2011 off the Pacific Coast of Tohoku Earthquake

KNOWLEDGE NOTE 5-1. Risk Assessment and Hazard Mapping. CLUSTER 5: Hazard and Risk Information and Decision Making. Public Disclosure Authorized

DAMAGE ANALYSIS OF WATER SUPPLY PIPES DUE TO THE 2004 NIIGATA-KEN CHUETSU, JAPAN EARTHQUAKE ABSTRACT

DYNAMIC DEFORMATION CHARACTERISTICS OF THE GROUND IDENTIFIED FROM SEISMIC OBSERVATIONS IN VERTICAL BOREHOLES

SIMULATION OF SPREADS OF FIRE ON CITY SITE BY STOCHASTIC CELLULAR AUTOMATA

The 2011 Tohoku earthquake and dams

AN EXPERIMETAL STUDY ON THE FLUID PROPERTIES OF LIQUEFIED SAND DURING ITS FLOW

4 Associate Professor, DPRI, Kyoto University, Uji, Japan

Development of Spherical Sliding Bearing

NEW ATTENUATION FORMULA OF EARTHQUAKE GROUND MOTIONS PASSING THROUGH THE VOLCANIC FRONT

Residual Deformation Analyses to Demonstrate the Effect of Thin Steel Sheet Piles on Liquefaction-Induced Penetration Settlement of Wooden Houses

Relationship between Building Damage Ratios and Ground Motion Characteristics during the 2011 Tohoku Earthquake

Rational Earthquake-resistant Design and Maintenance of Buried Pipelines

Simulated Earthquake Ground Motion for Structural Design"

Xiang Wen, & Takahashi Toru Chiba University, Chiba City, Japan. Katada Masaki Kyoto University, Kyoto, Japan

CHARACTERIZING SPATIAL CROSS-CORRELATION BETWEEN GROUND- MOTION SPECTRAL ACCELERATIONS AT MULTIPLE PERIODS. Nirmal Jayaram 1 and Jack W.

MONITORING OF URBAN RECONSTRUCTION: A STUDY OF RECOVERY PROCESS IN BAM AFTER THE 2003 EARTHQUAKE

EARTHQUAKE OBSERVATION OF A LOW-RISE BUILDING

BROADBAND STRONG MOTION SIMULATION OF THE 2004 NIIGATA- KEN CHUETSU EARTHQUAKE: SOURCE AND SITE EFFECTS

THE 2011 TOHOKU EARTHQUAKE IN JAPAN. VSU Lyuben Karavelov, Sofia, Bulgaria. Key words: Tohoku earthquake, strong ground motion, damage

RESIDUAL DISPLACEMENT PREDICTION OF R/C BUILDING STRUCTURES USING EARTHQUAKE RESPONSE SPECTRA

Synopses of Master Papers Bulletin of IISEE, 47, 73-78, 2013

DEVELOPMENT OF EMPIRICAL CORRELATION BETWEEN SHEAR WAVE VELOCITY AND STANDARD PENETRATION RESISTANCE IN SOILS OF CHENNAI CITY

DETAILED INVESTIGATION OF PILES DAMAGED BY HYOGOKEN NAMBU EARTHQUAKE

Realistic Performance Assessment of Water Supply Systems Under Extreme Events

STRONG MOTION PREDICTION ON ROCK SURFACE BY SUPERPOSED EVOLUTIONARY SPECTRA

SEISMIC HAZARD ANALYSIS. Instructional Material Complementing FEMA 451, Design Examples Seismic Hazard Analysis 5a - 1

APPLICATIONS OF EARTHQUAKE HAZARD MAPS TO LAND-USE AND EMERGENCY PLANNING EXAMPLES FROM THE PORTLAND AREA

Vibration Control Effects of Tuned Cradle Damped Mass Damper

ANALYSIS OF RECORDS OF THE 1999 CHICHI EARTHQUAKE IN TAIWAN AND CORRELATION WITH HOUSING DAMAGE. Takanobu SUZUKI 1

Seismic Performance Assessment Uses Incremental Dynamic Analysis

RECIPE FOR PREDICTING STRONG GROUND MOTIONS FROM FUTURE LARGE INTRASLAB EARTHQUAKES

SURFACE WAVES AND SEISMIC RESPONSE OF LONG-PERIOD STRUCTURES

DYNAMIC PROPERTIES OF STRUCTURE-PILE SYSTEM USING MOCK-UP MODEL

Analysis of Ignitions Following 2011 Tohoku Earthquake Using Kawasumi Model DRAFT

HORIZONTAL LOAD DISTRIBUTION WITHIN PILE GROUP IN LIQUEFIED GROUND

Study on the Effect of Loess Sites on Seismic Ground Motion and Its Application in Seismic Design

STUDY ON MICROTREMOR CHARACTERISTICS BASED ON SIMULTANEOUS MEASUREMENTS BETWEEN BASEMENT AND SURFACE USING BOREHOLE

Structures Group Report

Cyclic fatigue demands on structures subjected to the Canterbury Earthquake Sequence

中村洋光 Hiromitsu Nakamura 防災科学技術研究所 National Research Institute for Earth Science and Disaster Prevention, Japan (NIED) Outline

Special edition paper Development of Shinkansen Earthquake Impact Assessment System

SEISMIC ZONING FOR GROUND MOTION IN TOKYO BASED ON NATION-WIDE ELECTRIC GEOTECHNICAL DATABASE SYSTEM

MCEER researchers working on the seismic retrofit and rehabilitation

SEISMIC BEHAVIOR OF SHIELD TUNNEL ACROSS ACTIVE FAULT

AMPLIFICATION FACTOR OF PEAK GROUND MOTION USING AVERAGE SHEAR WAVE VELOCITY OF SHALLOW SOIL DEPOSITS

APPLICATON OF SEAMLESS SIMULATION OF SEISMIC RESPONSE ANALYSIS AND HIGH RESOLUTION TSUNAMI SIMULATION TO COASTAL AREA OF SENDAI

LIQUEFACTION ASSESSMENT BY THE ENERGY METHOD THROUGH CENTRIFUGE MODELING

SHAKE TABLE STUDY OF SOIL STRUCTURE INTERACTION EFFECTS ON SEISMIC RESPONSE OF SINGLE AND ADJACENT BUILDINGS

Evaluating the effects of near-field earthquakes on the behavior of moment resisting frames

A Feasibility Study about Extraction Method of Densely Crowded Areaswith Wooden Buildings in the KOBE Government. Part II 1)

SAFETY EVALUATION OF SEISMICALLY ISOLATED HOUSES WITH DISPLACEMENT RESTRAINT DEVICES UNDER SEVERE EARTHQUAKE MOTIONS

Investigation of Liquefaction-induced Damage to Wooden Houses in Urayasu City Caused by the Great East Japan Earthquake

Transcription:

Paper: Estimation of Seismic Shutoff of Intelligent Gas Meters in the Tokyo Metropolitan Area Yoshihisa Maruyama Λ,FumioYamazaki Λ, Yoshihisa Yano ΛΛ, and Naoyuki Hosokawa ΛΛ Λ Department of Urban Environment Systems, Chiba University 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan E-mail: ymaruyam@tu.chiba-u.ac.jp ΛΛ Tokyo Gas Co., Ltd. 1-5-20 Kaigan, Minato-ku, Tokyo 105-8527, Japan [Received September 10, 2008; accepted September 19, 2008] We conducted shaking-table tests to clarify the seismic shutoff features of intelligent gas meters stopping the supply of gas during earthquakes where Tokyo Gas Co., Ltd., provides service, and studied the relationship between earthquake movement and gas meter shutoff based on 200,000 monitored archive data points showing shutoff situations during actual seismic movement. Keywords: intelligent gas meter, seismic shutoff characteristics, shaking table test, actual shutoff data 1. Introduction The 1995 Kobe earthquake seriously damaged infrastructures such as the gas supply in densely populated central western Japan [1], resulting in higher postquake priority being given to antiquake measures. Tokyo Gas Co., Ltd., for one example, introduced earthquake monitoring and Seismic Information Gathering and Network Alert (SIGNAL) rapid damage assessment using 331 spectrum intensity (SI) sensors in 1994 [2]. Expanding SIGNAL to 3,800 SI sensors, the firm implemented Super-Dense Real-Time Monitoring of Earthquakes (SUPREME) in 2001 [3] whose data is to be used to assess early damage to the gas network. Results are expected to provide important information on gas supply suspension decision making. Almost all Tokyo Gas customers are served by intelligent gas meters [4] whose use is observed and automatically stopped in gas leakage. Meters also interrupt the gas supply if peak earthquake acceleration exceeds 150-250 cm/s 2. Meter manufacturers have been conducting product tests applying harmonic waves, but only 6 actual seismic movement records were applied to meters and only while meter prototypes were being developed, leaving uncertainty about actual seismic meter shutoff due to test limitations. In the 2005 northwest Chiba earthquake [5], many intelligent gas meters shut off gas because of shaking. The accuracy of the SUPREME subsystem used to estimate the number of meters shut off due to an earthquake is low, however, due to the uncertainty of seismic Fig. 1. Intelligent gas meter. shutoff features, and an initial rapid response to an earthquake is in doubt due to potentially incorrect estimation. To determine meter shutoff, we conducted a series of shaking-table tests applying sinusoidal waves and actual seismic movement records to meters in shaking-table tests. We also collected 200,000 shutoff archive data points after the Chiba earthquake to evaluate the relationship between recorded seismic movement and seismic meter shutoff. 2. Shaking-Table Tests 2.1. Product Tests by Manufacturers A steel ball hitting surrounding plates in an intelligent gas meter (Fig. 1) [6] generates an electrical current that the meter distinguishes from other impact based on the electrical current duration. An electrical current lasting more than 40 ms three times or more in 3 s is recognized as an earthquake (Fig. 2). Intelligent gas meters shut off gas if maximum input acceleration is 150-250 cm/s 2. Meter manufacturers conduct product tests in which meters undergo sinusoidal waves with periods of 0.3 s and 0.7 s (Fig. 3). Shutoff acceleration does not depend on the type of meter. Shutoff acceleration under a sinusoidal wave with a period of 0.3 s is essentially the same as that undergoing a sinusoidal wave with a period of 0.7 s, but product tests use only two periods for applied sinusoidal waves, making it necessary to further study seismic meter shutoff features and to consider meter shutoff acceleration under sinusoidal waves with different periods. 400 Journal of Disaster Research Vol.3 No.6, 2008

Estimation of Seismic Shutoff of Intelligent Gas Meters in the Tokyo Metropolitan Area Fig. 2. Example of seismic movement recognized by intelligent gas meter. Fig. 4. Intelligent gas meters and shaking-table tests. (a) Fig. 5. Shutoff accelerations for sinusoidal waves applied in the X direction. (b) Fig. 3. Average shutoff accelerations obtained in product tests under sinusoidal waves with periods of (a) 0.3 s and (b) 0.7 s. 2.2. Shaking-Table Tests Under Sinusoidal Waves In a series of intelligent gas meter tests (Pipeline Technology Center, Tokyo Gas Co., Ltd.), we applied sinusoidal waves with periods of 0.1-1.8 s to meters fixed to walls (Fig. 4). Sinusoidal wave amplitude was increased at 5 cm/s 2 intervals. When meters shut off the gas supply, voltage was generated for 60 ms to detect the change in voltage associated with shutoff, precisely identifying when meters shut off gas. Two types of gas meters, 3 NB- 3s and NB-4s each, were used in experiments. In the relationship between the period of applied sinusoidal waves and shutoff acceleration of intelligent gas meters (Fig. 5), sinusoidal waves were applied in the X direction (Fig. 4) during shaking-table tests and the shutoff acceleration of accelerometers on gas meters obtained (Fig. 5, means for three gas meters). Note that one NB3-2 meter interrupted the gas supply under sinusoidal waves with a period of 0.1 s at a shutoff acceleration of 171 cm/s 2. Shutoff acceleration is almost constant when sinusoidal waves range from 0.2 to 1.8 s. These results and those of two-directional shaking tests also conducted suggest that differences in shutoff acceleration for sinusoidal wave periods are small if the period ranges from 0.2 to 1.8 s. 2.3. Shaking-Table Tests Under Actual Seismic Movement We used three sets of seismic records as input for shaking-table tests (Fig. 6, acceleration response spectra (h = 0.05)) from ground movement from (1) the Kobe Marine Observatory record of the Japan Meteorological Agency (JMA) in the 1995 Kobe earthquake; (2) K-NET Yokaichiba records in the northeast Chiba earthquake on April 11, 2005; and (3) Miyako-cho Tokyo Gas seismic observation station records during the northwest Chiba Prefecture earthquake on July 23, 2005. Resultant horizontal peak ground acceleration (PGA) was scaled to 250 cm/s 2. Journal of Disaster Research Vol.3 No.6, 2008 401

Table 1. Number of meters shut off in shaking-table tests according to actual seismic movement records. Fig. 6. Acceleration response spectra with a 5% damping ratio of ground movement records whose horizontal peak accelerations were scaled to 250 cm/s 2. In results of shaking-table tests (Table 1), differences between input and observed PGA were generated in shaking-table tests, especially for JMA Kobe records. Peak ground velocity (PGV) was calculated by integrating acceleration time histories during shaking-table tests. The period of seismic movement, T, is estimated using Eq. (1) and the relationship between shutoff acceleration and periods of ground movement determined (Fig. 7). T = 2π PGV............. (1) PGA Comparing results for shaking-table tests under sinusoidal waves and seismic movement records (Fig. 7), we found that shutoff acceleration of NB-4 meters in JMA Kobe and K-NET Yokaichiba records was larger than under sinusoidal waves. NB-3 and NB-4 meters shut off gas at slightly different times (Fig. 8). NB-3 meters interrupted gas before the maximum amplitude arrived because ways of recognizing seismic movement differed for the two meters. As stated (Fig. 2), intelligent meters distinguish between seismic movement and other impact based on electrical current. Under another rule for recognizing seismic movement, the difference in earthquake recognition results in differences in times when meters shut off gas (Fig. 8). Fig. 7. Shaking-table tests under sinusoidal waves versus actual seismic records. Fig. 8. Gas supply interruption by intelligent meters in JMA Kobe records. 3. Seismic Meter Shutoff Archives During the 2005 Northwest Chiba Earthquake 3.1. Dataset Collected by ST24 Tokyo Gas has introduced different antiquake systems such as STATION 24 (ST24), which observes intelligent meters detect gas leakage and suspension though telecommunications. ST24 collects meter shutoff archives. We collected 200,000 shutoff archives after the 2005 northwest Chiba earthquake. Meters interrupting gas supply numbered 10,175. The dataset included addresses and structural types 1- or 2-story houses, mostly wooden, 402 Journal of Disaster Research Vol.3 No.6, 2008

Estimation of Seismic Shutoff of Intelligent Gas Meters in the Tokyo Metropolitan Area Fig. 9. JMA seismic intensity distribution in the 2005 Northwest Chiba earthquake recorded by SUPREME, Tokyo Gas Co., Ltd. and multistory buildings. Customers applying for ST24 service were mainly owners of detached dwellings. Shutoff archives for wooden houses occupy over 75% of collected archives. 3.2. Peak Ground Acceleration Versus Meter Shutoff SUPREME has been monitoring earthquakes and rapid damage assessment system since 2001. Ground movement records obtained by SUPREME were from 2,699 district regulators in the 2005 Chiba quake (Fig. 9). Ground movement amplitude depends on soil conditions, so we used meters within 500 meters of seismic observation stations to determine the relationship between meter shutoff and PGA. Multistory building response results in differences in seismic meter shutoff related to the floor monitored (Fig. 10, 12-story condominium), with shutoff on higher floors greater than on lower floors because building response amplified seismic movement. According to the dataset collected, none of the 11 meters in wooden houses near this condominium cut off gas during the earthquake, indicating the need to appropriately evaluate the effects of structural response. Since most shutoff archives we collected involved wooden houses, our results held for seismic shutoff features of meters in wooden houses 1 or 2 stories high for which the effect of structural response is essentially negligible at meter locations. In the relationship between PGA observed by SUPREME and meter shutoff in the Chiba quake (Fig. 11), shutoff archives for wooden houses 500 m or closer to the nearest Seismic station were used to obtain shutoff. As PGA increased, shutoff increased, but at a broad range for PGA, indicating that seismic movement might affect meter shutoff (Fig. 12, response spectra with Fig. 10. Seismic meter shutoff in a 12-story building after the 2005 northwest Chiba earthquake (Chuo Ward, Chiba). 5% damping ratio at two seismic observation stations). PGA at station A was 246.0 cm/s 2 and none of the 8 meters shut off gas. PGA at station B was 217.0 cm/s 2, with all 3 meters shutting off gas. The peak response spectrum at Station A was 0.1 s. As stated, only one meter of 6 shut off gas under sinusoidal waves with a period of 0.1 s, indicating that meters are insensitive to very short-period movement, which is why none shut off gas at Station A. In meter shutoff acceleration during the 2005 Chiba quake versus shaking-table test results during sinusoidal Journal of Disaster Research Vol.3 No.6, 2008 403

Fig. 11. PGA versus intelligent meter shutoff in wooden houses during the 2005 Northwest Chiba earthquake. Fig. 13. Shutoff acceleration in the 2005 Chiba Northwest earthquake and in shaking-table tests with sinusoidal waves. Fig. 12. Response spectra with 5% damping ratio at two seismic observation stations. waves (Fig. 13), meter shutoffaccelerationin considering shutoffs and meter shutoff acceleration in actual cases, the spatial distribution of peak ground acceleration should be taken into account. Assuming that ground acceleration spreads with median PGA recorded at a seismic observation station, shutoff acceleration in shaking-table tests correspond to PGA associated with 50% seismic shutoff in actual cases. The average PGA associated with 40-60% seismic shutoff averaged 150 cm/s 2 equivalent to experimentally obtained shutoff acceleration. Thus, although meter shutoff varied widely in PGA, this can be explained based on the spatial PGA distribution in the actual environment, indicating that meter shutoff can be estimated from PGA recorded by SUPREME. 4. Estimated Meter Shutoff Curve Tokyo Gas estimates the number of meter shutoffs after an earthquake, but the system sometimes overestimates or underestimates it, so we estimated meter shutoff using PGA observed by SUPREME. Multiplying the number of customers in a district by estimated shutoff, the number of meters shut off is predicted just after an earthquake. Fig. 14. Regression curves for meter shutoff in the 2005 Northwest Chiba earthquake. We used meter shutoff archives after the 2005 Chiba quake, that after the Feb. 16, 2005, earthquake (1,596.), and after the Oct. 16, 2005, quake (1,651 shutoffs). We considered two functions in determining the estimation curve. Meter shutoff P is assumed to follow the lognormal distribution (Eq. (2)), P = Φ((lnPGA λ)=ζ )......... (2) where Φ(x) is the standard normal distribution. λ is the logarithmic mean and ζ standard deviation. Seismic shutoff is also assumed to follow the logistic distribution in Eq. (3), 1 P =....... (3) 1 + exp[ (β 0 + β 1 PGA)] where β 0 and β 1 are parameters in logistic distribution. We conducted two types of regression analysis to determine parameters in Eqs. (2) and (3) using the least squares method and the weighted least squares method. The number of meters is used as a weight in weighted regression analysis (Fig. 14) for shutoffs in the 2005 Chiba quake. Regression curves assuming log-normal distribu- 404 Journal of Disaster Research Vol.3 No.6, 2008

Estimation of Seismic Shutoff of Intelligent Gas Meters in the Tokyo Metropolitan Area 5. Conclusions (a) Based on shaking-table tests and statistical analysis using shutoff archives to clarify seismic shutoff features of intelligent gas meters, we found that shutoff acceleration under sinusoidal waves was essentially constant for the period of sinusoidal waves. The fact that meters did not interrupt gas supply at an applied movement of 0.1 s indicates that meters are not sensitive to very short-period ground excitation. From estimation curves for meter shutoff constructed based on PGA values observed by SUPREME and shutoff archives collected by ST24, we found that only shutoff datasets of meters in detached, mostly wooden dwellings did not include the effects of structural response to ground movement. Further research is thus needed to clarify effects of structural response to seismic meter shutoff. (b) Fig. 15. Regression curves among three earthquake events for (a) log-normal distribution and (b) logistic distribution whose parameters were determined by the weighted least squares method. References: [1] S. Oka, Damages of gas facilities by great Hanshin earthquake and restoration process, Proc. of the 6th U.S.-Japan Workshop on Earthquake Disaster Prevention for Lifeline Systems, pp. 253-269, 1995. [2] Y. Yoshikawa, H. Kano, F. Yamazaki, T. Katayama, and N. Akasaka, Development of SIGNAL: An early warning system of city gas network, Proc. of 4th U.S. Conference on Lifeline Earthquake Engineering, ASCE, 1995, pp. 160-167. [3] Y. Shimizu, F. Yamazaki, S. Yasuda, I. Towhata, T. Suzuki, R. Isoyama, E. Ishida, I. Suetomi, K. Koganemaru, and W. Nakayama, Development of real-time control system for urban gas supply network, Journal of Geotechnical and Geoenvironmental Engineering, ASCE, Vol.132, No.2, pp. 237-249, 2006. [4] Tokyo Gas Co., Ltd., Safety operation guide, http://www.tokyogas.co.jp/foreign/english/userguide/anzen/yobou/index.html [5] Strong motion observation office, Earthquake research institute, The University of Tokyo: http://taro.eri.u-tokyo.ac.jp/saigai /chiba/index.html [6] The high pressure gas safety institute of Japan: http://www.khk.or.jp/activities/research development/lpg lab/dl /saigai.pdf Yoshihisa Maruyama Fig. 16. Estimation curve for meter shutoff we proposed. Assistant Professor, Department of Urban Environment Systems, Chiba University tion without weight and logistic distribution determined by the weighted least squares method show good estimations. Differences among earthquake events were seen for logistic distribution considering the weight for determining parameters (Fig. 15). We used log-normal distribution without considering the weight to represent the relationship between PGA and meter shutoff (Fig. 16). 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan 2004 Completed Doctor course of Graduate School, Dept. of Civil Engineering, The University of Tokyo 2004- Postdoctoral Research Fellow, Center for Urban Earthquake Engineering, Tokyo Institute of Technology 2005- Research Associate, Department of Urban Environment Systems, Chiba University Journal of Disaster Research Vol.3 No.6, 2008 405

Fumio Yamazaki Professor, Department of Urban Environment Systems, Chiba University 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan 1978 Completed Master course of Graduate School, Dept. of Civil Engineering, The University of Tokyo 1978- Shimizu Corporation 1989- Associate Professor, Institute of Industrial Science, The University of Tokyo 2001- Professor, Asian Institute of Technology (AIT), Bangkok, Thailand 2003- Professor, Department of Urban Environment Systems, Chiba University Yoshihisa Yano Tokyo Gas Co., Ltd. 2-5-19 Minami-Azabu, Minato-ku, Tokyo 106-0047, Japan 2005 Graduated from Department of Urban Environment Systems, Chiba University 2007 Completed Master course of Graduate School, Department of Urban Environment Systems, Chiba University 2007 Tokyo Gas Co., Ltd. Naoyuki Hosokawa Supply and Disaster Management Department, Tokyo Gas Co., Ltd. 1-5-20 Kaigan, Minato-ku, Tokyo 105-8527, Japan 1994 Graduated from Department of Civil Engineering, The University of Tokyo 1996 Completed Master course of Graduate School, Dept. of Civil Engineering, The University of Tokyo 1996 Tokyo Gas Co., Ltd. 406 Journal of Disaster Research Vol.3 No.6, 2008