[ xevo G2 tof ] Your Quantitative and Qualitative Questions Answered. Exactly.

Similar documents
IN QUALITATIVE ANALYSIS,

[ XEVO G2-XS QTOF ] EXTRAORDINARY POSSIBILITIES FOR YOUR EVERYDAY ANALYSIS

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

EXPRESSION MORE PEPTIDES. MORE PROTEINS. MORE REPRODUCIBILITY. MORE QUANTIFICATION.

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Traditional Herbal Medicine Structural Elucidation using SYNAPT HDMS

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

High-Field Orbitrap Creating new possibilities

2010 Waters Corporation. Xevo TQ-S for Bioanalysis

ABI 3200 Q TRAP LC/MS/MS System

[ FOOD SAFETY SOLUTIONS ] FASTER, EASIER, AND MORE ACCURATE FOOD SAFETY ANALYSES

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

C HA R AC T E RIZ AT IO N O F INK J E T P RINT E R C A RT RIDG E INK S USING A CHEMOMETRIC APPROACH

Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate Yu 3

Designed for Accuracy. Innovation with Integrity. High resolution quantitative proteomics LC-MS

Multi-residue analysis of pesticides by GC-HRMS

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

ApplicationNOTE A STUDY OF THE ANALYSIS OF POLYBROMINATED DIPHENYL ETHER FLAME RETARDANTS BY GC/MS/MS. Introduction. Materials and Methods

UNIFI - Targeted and Untargeted Screening MS Software

ImprovIng ADmE ScrEEnIng productivity In Drug DIScovEry

ApplicationNOTE ULTRA TRACE ANALYSIS OF DIOXINS AND FURANS IN HUMAN ADIPOSE TISSUE USING SFE-LC EXTRACTION/CLEANUP AND THE WATERS AUTOSPEC ULTIMA NT

microtof-q III Innovation with Integrity The bench-mark in accurate mass LC-MS/MS ESI-Qq-TOF

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Q-TOF PREMIER DYNAMIC RANGE ENHANCEMENT AND ACCURATE MASS MEASUREMENT PERFORMANCE

Analysis of Labeled and Non-Labeled Proteomic Data Using Progenesis QI for Proteomics

[ Care and Use Manual ]

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Stephen McDonald and Mark D. Wrona Waters Corporation, Milford, MA, USA INT RO DU C T ION. Batch-from-Structure Analysis WAT E R S SO LU T IONS

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

ApplicationNOTE Abstract

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

Translational Biomarker Core

A Case of Pesticide Poisoning: The Use of a Broad-Scope Tof Screening Approach in Wildlife Protection

Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

[ instrument specifications ]

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Quan/Qual Analyses. Unmatched Confidence for. Thermo Scientific Q Exactive Orbitrap LC-MS/MS System. Identify Quantify Confirm

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

Introduction to Fourier Transform Infrared Spectroscopy

MetWorks Metabolite Identification Software

Performing Peptide Bioanalysis Using High Resolution Mass Spectrometry with Target Enhancement MRM Acquisition

Stephen McDonald, Mark D. Wrona, Jeff Goshawk Waters Corporation, Milford, MA, USA INTRODUCTION

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Finnigan LCQ Advantage MAX

of mass spectrometry

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Thermo Finnigan LTQ. Specifications

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

for XPS surface analysis

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Making Sense of Differences in LCMS Data: Integrated Tools

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Thermo Scientific LTQ Velos Dual-Pressure Linear Ion Trap

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

Theory and Practical Consequences.

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

WALKUP LC/MS FOR PHARMACEUTICAL R&D

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Natural Products. Innovation with Integrity. High Performance NMR Solutions for Analysis NMR

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

This document is a preview generated by EVS

LC-MS Based Metabolomics

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Quantitative and Qualitative Confirmation of Pesticides in Beet Extract Using a Hybrid Quadrupole-Orbitrap Mass Spectrometer

Impurity Profiling of Pharmaceutical Starting Materials Using Gas Chromatography Coupled with High- Resolution Accurate Mass Spectrometry

Introduction to Fourier Transform Infrared Spectroscopy

WADA Technical Document TD2003IDCR

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM

ANALYSIS OF BASIC COMPOUNDS

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

Targeted protein quantification

Guide to Peptide Quantitation. Agilent clinical research

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Powerful Scan Modes of QTRAP System Technology

Basic Principles for Purification Using Supercritical Fluid Chromatography

Analysis of Polar Metabolites using Mass Spectrometry

MassHunter TOF/QTOF Users Meeting

Application Note LCMS-116 What are we eating? MetaboScape Software; Enabling the De-replication and Identification of Unknowns in Food Metabolomics

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

ultimate efficiency unleashed [ Cortecs 1.6 µm columns ]

4000 Q TRAP LC/MS/MS System. Advanced Linear Ion Trap technology at the highest level of sensitivity 4000 QTRAP. LC/MS/MS System

Conformational Characterization of Calmodulin by Hydrogen Deuterium Exchange Mass Spectrometry

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Transcription:

[ xevo G2 tof ] Your Quantitative and Qualitative Questions Answered. Exactly.

Xevo G2 Tof Quantitative and qualitative answers from a single analysis. For scientists who need to confidently identify and quantify unknown compounds in complex samples, the Xevo G2 Tof mass spectrometer with UPLC /MS E and QuanTof technology offers exceptional levels of selectivity, in-spectrum dynamic range, speed of analysis, quantitative accuracy and exact mass performance simultaneously at unparalleled levels of sensitivity. Whether your focus is on peptide mapping experiments, protein intact mass analysis, metabolite identification, discovery DMPK quantification, food safety screening, or environmental monitoring, Xevo G2 Tof provides the highest quality information, so you can make decisions better, faster, and easier than ever before. Detect your compounds with high resolution With resolution in excess of 22,5 FWHM at speeds of up to 3 spectra per second, Xevo G2 Tof coupled to UltraPerformance LC delivers the selectivity to see low level peaks of interest in complex samples. 1 785.8 786.3 1 m/z 786 787 788 Resolution at high acquisition rates. UPLC/MS acquisition of [Glu-1] Fibrinopeptide B shows mass resolution of 25, FWHM at a data acquisition rate of 3 spectra per second. The chromatographic peak is 1.3 seconds wide at base and contains 4 spectra. Time.7.8.9

[ xevo G2 tof ] [ xevo G2 tof ] Identify unknowns with elemental composition Determining the correct elemental composition of ions is critical when identifying unknown compounds. Exact mass measurement, together with accurate isotope pattern information, allows elemental compositions to be determined with maximum confidence, for both precursor and fragment ions. Capability without compromise Our design philosophy of Engineered Simplicity is the combination of highest performance with system versatility and simplicity of operation high performance n QuanTof technology For the most sensitive, exact mass, quantitative and qualitative benchtop MS system n UPLC/MS E A simple, patented method of data acquisition that comprehensively catalogs complex samples in a single analysis versatility n Universal Ion Source Architecture The most extensive range of interface capabilities to service the broadest range of applications A tomato extract spiked with a mixture of pesticides was analyzed by UPLC/MS E. The precursor ion exact-mass at m/z 192.772 matches to within.1 mda of the calculated value for the elemental composition C 9 H 1 N 3 O 2. The observed isotope pattern matches closely to this elemental composition, as indicated by the low i-fit value displayed. The MS E fragment ion at m/z 16.511 has an elemental composition of C 8 H 6 N 3 O and matches exactly to loss of CH 3 OH, simultaneously confirming the elemental composition and giving structural information on the molecule, which can be identified confidently as the pesticide Carbendazim. simplicity of operation n Engineered Simplicity Guarantees maximum system performance and usability n System solutions The most complete system solutions backed by superior support to ensure your success Upgrade path to QTof functionality Future proof your laboratory investment with a simple upgrade path to exact mass MS/MS capability

Engineered Simplicity high performance ng Yeast Enolase on column 1.8 1.6 1.4 1.2 1.8.6.4 Quantitation Precision and accuracy of quantitative measurements..2 5 1 15 2 25 3 35 4 Injection number Yeast enolase was spiked into a tryptic digest of E. coli cell lysate and analyzed by a nanoscale UPLC separation with MS E. The data was processed using Waters Expression E Software. The average observed amount on column (1.55 ng protein) agreed within 1 of the theoretical amount on column (1.7 ng protein) with a relative standard deviation of 7 over 35 replicate injections. 1 S/N:RMS=146.32 Sensitivity Reserpine, 1 pg on column. Time 1. 1.5 2. Extracted exact mass chromatogram (69.2812±.2 Da) showing S/N obtained for 1 pg reserpine on column. 1 PEG C 18 H 38 O 1 Na Observed Mass 437.2364.1 mda Error 393.214 349.1837 437.2364 PEG peak intensity: 481.2628 Verapamil peak intensity: 2.76e3 Verapamil 1 C 27 H 38 N 2 O 4 4.11e7 Observed Mass 455.291.9 mda Error 455.291 454 455 456 m/z Dynamic Range This dynamic range is obtained even in the most complex spectra. 3 35 4 45 5 55 6 m/z Verapamil was spiked at a low level into a solution of polyethylene glycol (PEG). Xevo G2 Tof shows excellent mass accuracy over greater than 4 orders of magnitude in-spectrum dynamic range without compromising mass resolution.

y [ xevo G2 tof ] QuanTof performance without compromise. Powered by QuanTof technology, Xevo G2 Tof delivers the most sensitive, exact mass, quantitative and qualitative performance of any benchtop MS system. QuanTof s high-field pusher and dual-stage reflectron, incorporating high-transmission parallel wire grids, reduce ion turnaround times due to pre-push kinetic energy spread and improve focusing of high energy ions respectively. These innovative technologies combine to provide the highest levels of Tof performance. The novel ion detection system combines an ultrafast electron multiplier and hybrid ADC detector to provide outstanding sensitivity and quantitative performance. QuanTof delivers exact mass with high precision across LC peaks, which in turn provides high selectivity and confidence for the detection and identification of components in complex mixtures. Scan # Measured Mass Error (mda) Error (ppm) 1 228.1284.1.4 2 228.1288.5 2.2 3 228.1285.2.9 4 228.1284.1.4 1 2 3 6 7 8 5 4 9 1 Selectivity Stability of exact mass over a chromatographic peak. 5 228.1283.. 6 228.1286.3 1.3 7 228.1283.. 8 228.1283.. 9 228.1283.. 1 228.1287.4 1.8 1 11 12 11 228.1283.. 12 228.1283.. Scan 69 695 7 75 71 715 72 725 73 Summing scans across this peak gives m/z 228.1284 =.1 mda or.4 ppm The pesticide ametryn (m/z 228.1283) spiked into tomato at 12.5 ppb. The peak is 2.4 seconds wide and each individual scan shows better than 1 mda mass accuracy, allowing narrow mass windows for extracted mass chromatograms, increasing the selectivity of exact mass quantitative experiments.

Engineered Simplicity high performance UPLC/MS E all of the data, all of the time Xevo G2 Tof offers UPLC/MS E, so you can see all of the data all of the time. When you need to confirm the identity and structure of known or unknown compounds you can get high-quality, unambiguous, exact mass precursor and fragment ion data quickly and easily n Identify and quantify from a single dataset 1,2 n Maximize the UltraPerformance Liquid Chromatography advantage n Use simple, generic methods n Get exact mass precursor and fragment ion spectra from every detectable component in your sample 1 -.1 mda 16.51 +.1 mda 192.774 -.1 mda 132.561 -.3 mda +.2 mda 15.45 92.52 161.537 193.835 196.84 75 1 125 15 175 2 225 m/z UPLC/MS E spectrum of Carbendazim spiked into tomato at a concentration of 12.5 ppb. Excellent exact-mass performance and MassFragment Software allow fragment ions to be assigned structures automatically and compounds to be characterized with high confidence. Reference 1. Silva, Gorenstein, Li, Vissers, Geromanos, Absolute Quantification of Proteins by LC/MSE, Mol. Cell. Proteomics, 5.1, 144-156

[ xevo G2 tof ] UPLC/MS E : Simply thorough, thoroughly simple 18 16 14 12 1 8 6 4 2 5 1 15 2 UPLC/MS E is a simple, patented method of data acquisition that comprehensively catalogs complex samples in a single analysis. Prior to the implementation of the accurate mass LC/MS E approach, this level of productivity would have been extremely difficult to achieve. The capacity for conducting preliminary metabolite identification experiments has increased by almost an order of magnitude, and the turnaround time for metabolism data has been shortened to the point where the information has a much greater impact on decision making. y UPLC/MS E is a method of data acquisition that records exact mass precursor and fragment ion information, while simultaneously obtaining accurate quantitative profiles from every detectable component in a sample. UPLC/MS E rapidly alternates between two functions: the first acquiring low-energy exact mass precursor ion spectra; the second acquiring elevated-energy exact mass fragment ion; every mass is measured, and spectra for each component aligned in retention time. UPLC/MS E records data without discrimination or pre-selection, so your samples are completely cataloged in a single analysis. Tiller PR et al, Rapid Commun. Mass Spectrom. 28 Apr: 22(7): 153-61.

Engineered Simplicity versatility Problem Solving has never been so efficient The Universal Ion Source Architecture of Xevo G2 Tof allows you to use the widest range of ionization techniques as well as the very latest innovations in ionization technologies. With the Atmospheric Pressure GC (APGC) source you have the capability to perform GC and LC separations on a single MS platform. You ll benefit from the ability to analyze volatile and semi-volatile compounds of low and intermediate polarity traditionally analyzed only by dedicated vacuum GC/MS instruments. 3 The Atmospheric Solids Analysis Probe (ASAP) allows spectra to be rapidly generated from virtually any sample with minimum sample preparation. 4

y [ xevo G2 tof ] Total flexibility Change your ion sources Not your instrument y When you need options and time is critical, the ion sources are quickly interchangeable and ready to use within minutes. ESI Electrospray Ionization APCI Atmospheric Pressure Chemical Ionization ESCi Dual ESI and APCI APPI Atmospheric Pressure Photo Ionization APCI Atmospheric Pressure Chemical Ionization ASAP Atmospheric Solids Analysis Probe APGC Atmospheric Pressure Gas Chromatography nanoflow ESI Plug and Play nanoflow Also compatible with DESI (Prosalia), DART (IonSense), LDTD (Phytronix), TriVersa NanoMate (Advion) sources

Engineered Simplicity simplicity of operation Simplicity starts with IntelliStart Xevo G2 Tof features IntelliStart Technology, an intuitive interface that automates routine tasks. This technology ensures that all levels of scientist can operate the instrument quickly and confidently, to generate reproducible UPLC/MS data of the highest quality. Automated MS Resolution & Calibration Checks Simple setup of diverse experiments Automated LC/MS System Check Automated System Monitoring Upgrade to Xevo G2 QTof

[ xevo G2 tof ] System solutions for the way you work Revolutionize your workflow with Xevo G2 Tof and Engineered Simplicity PREPARE ANALYZE INTERPRET DECIDE IntelliStart ensures your system is ready to run, for experts and beginners alike. Waters Universal Ion Source Architecture, QuanTof technology, UPLC/MS, E and FastDDA will equip you with an entirely new level of quantitative and qualitative capability. Process, visualize, compare, and interpret the most complex data automatically. Then turn it into meaningful information quickly with targeted informatics software. Generate reports, share results and archive information easily with Waters laboratory informatics. Make decisions faster and better than ever before. Xevo G2 Tof enables you to future-proof your laboratory investment with a simple onsite upgrade path to QTof functionality. Xevo G2 QTof delivers full scan, exact mass MS/MS for targeted qualitative and quantitative analyses and UPLC/FastDDA for rapid, automated, intelligent exact mass MS/MS for full structural characterization as well as isobaric labelling quantitative proteomics experiments.

Sales Offices: Austria 43 1 877 18 7 Australia 61 2 9933 1777 Belgium and Luxembourg 32 2 726 1 Brazil 55 11 4134 3788 Canada 1 8 252 4752 China 86 21 6156 2666 Czech Republic 42 2 617 11384 Denmark 45 46 59 88 Finland 358 9 5659 6288 France 33 1 3 48 72 Germany 49 6196 4 6 Hong Kong 852 2964 18 Hungary 36 1 35 586 India 91 8 2837 19 Ireland 353 1 448 15 Italy 39 2 265 983 Japan 81 3 3471 7191 Korea 82 2 63 48 Mexico 52 55 52 186 The Netherlands 31 76 58 72 Norway 47 6 384 65 Poland 48 22 833 44 Puerto Rico 1 787 747 8445 Russia/CIS 7 495 727 449 / 29 9737 Singapore 65 6593 71 Spain 34 93 6 93 Sweden 46 8 555 115 Switzerland 41 56 676 7 Taiwan 886 2 251 9928 UK 44 28 238 61 US 1 8 252 4752 References: 1. Silva, Gorenstein, Li, Vissers, Geromanos; Absolute Quantification of Proteins by LC/MS E ; Mol. Cell. Proteomics; 5.1, 144-156. 2. Tiller, Yu, Castro-Perez, FillGrove, Baillie; High-Throughput, Accurate Mass Liquid Chromatography/Tandem Mass Spectrometry on a Quadrupole Time-of-Flight System as a First-Line Approach for Metabolite Identification Studies; Rapid Commun. Mass Spectrom., 28, 22, 153-161. 3. Portoles, Sancho, Hernandez, Newton, Hancock; Potential of Atmospheric Pressure Chemical Ionisation Source in GC-QTof MS for Pesticide Residue Analysis; J. Mass. Spectrom.; 21, 45, 926-936. 4. Twohig, Shockcor, Wilson, Nicholson, Plumb; Use of An Atmospheric Solids Analysis Probe for High Throughput Screening of Biological Fluids: Preliminary Applications on Urine and Bile; J. Proteome Res., 21, 9 (7), 359-3597. www.waters.com/xevog2tof Waters Corporation 34 Maple Street Milford, MA 1757 U.S.A. T: 58 478 2 F: 58 872 199 www.waters.com Waters, Xevo, UltraPerformance LC, ACQUITY UPLC, NuGenesis, ESCi, nd UPLC are registered trademarks of Waters Corporation. The Science of What s Possible, Engineered Simplicity, MassLynx, IntelliStart, MetaboLynx, MarkerLynx, BiopharmaLynx, ifit, and ProteinLynx Global SERVER are trademarks of Waters Corporation. All other trademarks are the property of their respective owners. 21 Waters Corporation. Printed in the U.S.A. December 21 723832EN-A4 AO-CP