Acclaim HPLC and UHPLC Columns

Similar documents
Acclaim HPLC and UHPLC Columns

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Thermo Scientific Acclaim. Catalogue 9. Hichrom Limited

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Acclaim Mixed-Mode WCX-1

for Acclaim Mixed-Mode WCX-1

for Acclaim Mixed-Mode HILIC-1 Column

penta-hilic UHPLC COLUMNS

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Packings for HPLC. Packings for HPLC

penta-hilic UHPLC COLUMNS

LC Technical Information

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

LC and LC/MS Column Selection Flow Chart

Acclaim Mixed-Mode WAX-1 Columns

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

for Acclaim Trinity TM P1

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

Acclaim HILIC-10 Columns

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

Alltech Alltima HP Introduction

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

8. Methods in Developing Mobile Phase Condition for C18 Column

Optimisil HPLC & UPLC Column catalogue

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Pharmaceutical Analysis of API and Counter Ions in Complex Formulations in a Single Injection

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

Advantages of polymerbased. an alternative for ODS

ColumnsAcclaim PolarAdvantage II (PA2) HPLC Columns

HPLC Column Selection: Solve the Separation Mystery. The world leader in serving science

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

Reversed Phase Solvents

UPLC Method Development and Validation

LC Columns with Liquid Separation Cell Technology

Comparison of different aqueous mobile phase HPLC techniques

Technical Guide Thermo Scientific Syncronis HPLC Columns

Application Specific HPLC and UHPLC Columns

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Hypersil BDS Columns TG 01-05

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific

Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions

Part 2. Overview of HPLC Media

Cation Exchange HPLC Columns

Sepax SRT -C, Zenix -C SEC Phases

How proteins separate on reverse-phase HPLC

Method Development Kits

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

It s hot! ZIC -chilic

Shodex TM ODP2 HP series columns

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

InertSustainSwift C8

Analyze Nucleotides, Nucleosides, Purine, and Pyrimidine Bases Simultaneously with the Ultra IBD Column

Changing the way you think about HPLC

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Dionex IonPac AS28-Fast-4µm column

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated

Thermo Scientific Acclaim Surfactant Plus Column

Passion. Power. Productivity.

FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Small Molecule Selectivity Sampler

Fluophase and Fluofix Columns

New Developments in Surfactant Analysis Using HPLC

New Product Update. HPLC Columns

C18 Column. Care & Use Sheet

1.7 m Fortis UHPLC Columns

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Acclaim AmG C18 Column

Inertsil ODS-EP Technical Information

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches

Next Generation of Phenyl Columns. Chromatography Products.

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

SPE. Simply Efficient! Watchers bond Solid Phase Extraction by ISU. Ver

Method Development with ZirChrom's Ion Exchange Phases

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

Too Polar for Reversed Phase What Do You Do?

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)

Choosing Columns and Conditions for the Best Peak Shape

Open Column Chromatography, GC, TLC, and HPLC

Transcription:

Acclaim HPLC and UHPLC Columns Optimal selectivity through innovative chemistries Designed for separating a variety of analytes, from small neutral and polar molecules to complex mixtures. Ideal for pharmaceutical, environmental, food and beverage and chemical applications. Novel and proprietary surface chemistries Strict manufacturing and quality processes O OH O For optimum resolution of complex mixtures O Thermo Scientific Chromatography Columns and Consumables 6-7 Spherical Silica Providing consistent quality and performance The Acclaim web page contains the latest news, applications and downloads for the Acclaim HPLC column range. Visit www.thermoscientific.com/acclaim -

6 mau Acclaim C8 performance reversed-phase columns for reproducible results hydrophobic retention Excellent efficiencies for maximum resolution silanol activity for excellent peak shapes for basic analytes Extremely low bleed, fully compatible with MS The Acclaim columns are designed for high resolution reversed-phase separations. The very high surface coverage and very low metal content together result in columns with excellent efficiencies. These columns provide exceptional performance for a variety of applications in the pharmaceutical, chemical, environmental and food separations areas. A Standard Column 5 6 5 B RSLC Column 6 Acceleration 6 8 C Double Velocity Acceleration 5 to 8 Å 8 5 Particle Size.μm, μm, 5μm USP L A: Acclaim C8, 5μm, 5 x.6mm B, C: Acclaim RSLC C8,.μm, 5 x.mm Mobile Phase: mm HOAc in % (v/v) MeOH Temperature: C Flow Rate: A:.mL/min B:.mL/min C:.8mL/min Injection Volume: A: μl B:.μL C:.μL Detection: UV, 5 nm, A: Hz data rate B: 5 Hz data rate C: Hz data rate Analytes:. p-hydroxybenzoic acid. p-hydroxybenzaldehyde. Vanillic acid. Vanillin Sample: Commercial vanilla extract in % ethanol, filtered Reference: AOAC Official Method 99.5 LC Columns and Accessories >> Acclaim Acclaim C8 Particle Size (μm) Format Length (mm).mm ID.mm ID.6mm ID. RSLC Column 7 766-5 6898 765-75 - 75697-6898 76-5 799 - - 5 78 - - HPLC Column - 667-5 598 6897 59 75-667 - 599 7686 59 5 59 669 59 5 7687 777-5 Guard Cartridge 69689 798 69695 HPLC Column 5 - - 598 5 - - 599 See page -7 for Ordering Guide www.thermoscientific.com/chromatography -5

Acclaim C8 performance reversed-phase columns with intermediate hydrophobic retention silanol activity for excellent peak shapes for basic analytes Excellent column efficiencies LC-MS compatible Acclaim C8 reversed-phase columns feature densely bonded monolayer C8 ligands on a high-purity, spherical porous silica substrate. The columns are a well-characterized line of LC-MS compatible C8 phases with very high surface coverage and extremely low silanol activity. These columns provide exceptional performance for a variety of applications in the pharmaceutical, environmental, food and many other industrial sectors. to 8 Å 5 Particle Size.μm, μm, 5μm USP L7 mau Triclosan in toothpaste 8 8. nm Mobile Phase: Isocratic, 5% buffer, (mm Ammonium acetate ph5), 85% methanol (v/v) Temperature: 5 C Flow Rate:.mL/min Injection Volume:.μL Detection: Diode array detector, 8nm, Hz,. s resp. time and spectra nm Analytes:. Saccharin. Triclosan Sample: Toothpaste containing.% triclosan.... Thermo Scientific Chromatography Columns and Consumables 6-7 Acclaim C8 Particle Size (μm) Format Length (mm).mm ID.mm ID.6mm ID. RSLC Column - 768-5 765 769-766 76-5 767 - - 5 78 - - HPLC Column 5 59-595 59-596 5 59 6897 597 5 7685 - - 5 Guard Cartridge 69688 7979 69696 HPLC Column 5 59-598 - - 599 5 596-59 5 - - 59 See page -7 for Ordering Guide -6

Acclaim Phenyl- A unique reversed-phase column with high aromatic selectivity aromatic selectivity hydrophobic retention Unique and complementary selectivity compared to any other phenyl type column Compatibility with highly aqueous mobile phase efficiency and rugged packing Acclaim Phenyl- has a higher pi-pi interaction than other phenyl phases and provides unique selectivity for aromatic compounds while maintaining sufficient hydrophobic interaction and aqueous compatibility for superior chromatographic performance. The Acclaim Phenyl- column can be used in a wide range of applications in pharmaceutical, environmental, food testing and product-quality testing. This column is ideally suited for the analysis of aromatic analytes; some examples include glucocorticosteroids, estrogens, fat-soluble vitamins and phospholipids. to 8 Å 5 Particle Size μm, 5μm USP L LC Columns and Accessories >> Acclaim 6 mau 5 6 9 8 7 6 8 Mobile Phase: Methanol/water v/v 9/ Temperature: C Flow Rate:.5mL/min Injection Volume: μl Detection: UV, nm Analytes: ( ppm each). Retinol acetate (vitamin A acetate). Vitamin D. Vitamin D. delta-tocopherol 5. gamma-tocopherol 6. alpha-tocopherol (vitamin E) 7. Impurity (unknown) 8. Vitamin E acetate 9. Vitamin K. Vitamin K Acclaim Phenyl- Particle Size (μm) Format Length (mm).mm ID.mm ID.6mm ID Guard Cartridge 799 797 797 HPLC Column 5 797 797 7969 5 HPLC Column 5 - - 886 5 - - 79697 Format Acclaim Guard Cartridge Holder V- 6958 Acclaim Guard Kit (Holder and Coupler) V- 6977 Guard to Analytical Column Coupler V- 788 www.thermoscientific.com/chromatography -7

Acclaim C Columns for separating structurally related isomers shape selectivity Unique selectivity complementary to other reversed-phase columns Compatibility with highly aqueous mobile phase -quality: low column bleed, high efficiency and rugged packing The Acclaim C is designed to provide high shape selectivity for separating hydrophobic structural related isomers and unique selectivity complementary to other reversed-phase columns (e.g. C8). to 8 Å 5 Particle Size μm, 5μm USP L6 pa A B 6 ng Area 9 8 9 6 7 5 LLA 6 8 Mobile Phase A: Water:formic acid:mobile phase B 9:.6: (v/v) Mobile Phase B: Acetone:acetonitrile:THF:formic acid 675:5::(v/v) Gradient: Time (min) %A %B 6 7 5 95 5 95 9 Temperature: C Flow Rate:.mL/min Injection Volume: μl Detection: Corona ultra, nebulizer 5 C, filter high Analytes:. SDA. EPA. ALA. GLA 5. DHA 6. Arach. 7. LLA Samples: A. Standards in isopropanol B. Saponified chicken fat Thermo Scientific Chromatography Columns and Consumables 6-7 Acclaim C Particle Size (μm) Format Length (mm).mm ID.mm ID.6mm ID HPLC Column 5 78666-7866 78665 - - 5 7575 757 757 5 7866 7576-5 Guard Cartridge 757 757 757 HPLC Column 5 - - 7579 5 - - 7578 Format Acclaim Guard Cartridge Holder V- 6958 Acclaim Guard Kit (Holder and Coupler) V- 6977 Guard to Analytical Column Coupler V- 788-8

Acclaim PolarAdvantage Novel polar-embedded reversed-phase columns with unique selectivity Selectivity complementary to the C8 column silanol activity for excellent peak shape with basic compounds Compatible with % aqueous mobile phase selectivity for hydrophobic aromatic molecules Wide range of applications Acclaim PolarAdvantage (PA) columns feature a patented bonding column chemistry that incorporates a polar sulfonamide group with an ether linkage near the silica surface. This unique chemistry provides low silanol activity, compatibility with % aqueous mobile phase. The Acclaim PA column offers great separation power to resolve a wide variety of polar and non-polar analytes and supports LC-MS analysis. EPA 6 phenols 6 mau 5 6 7 8 9.5..5..5. Mobile Phase A: mm formic acid + mm ammonium formate, ph.75 ±.5 Mobile Phase B: Acetonitrile Gradient: -.5...6. %A 7 7 7 %B 9 9 Temperature: C Flow Rate:.5mL/min Injection Volume:.5μL Detection: UV, 8nm, Hz,.5s resp. time Analytes:. Phenol.,-Dinitrophenol. -Nitrophenol. -Chlorophenol 5. -Nitrophenol 6.,-Dimethylphenol 7.,6-Dinitro--methylphenol 8. -Chloro--methylphenol 9.,-Dichlorophenol.,,6-Trichlorophenol. Pentachlorophenol Sample: Calibration mix, 5μg/mL in water to 8 Å 6 5 Particle Size.μm, μm, 5μm USP L6 LC Columns and Accessories >> Acclaim Acclaim PolarAdvantage Particle Size (μm) Format Length (mm).mm ID.mm ID.6mm ID. RSLC Column 5 76 - - 75-75698 - 76 767-5 76 - - 5 78 - - HPLC Column 5 67 6897-66 76-5 67 669 68 5-779 - 5 Guard Cartridge 6969 798 69698 HPLC Column 5 - - 69 5 - - 6 5 - - 6 www.thermoscientific.com/chromatography -9

Acclaim PolarAdvantage II Complementary selectivity and enhanced hydrolytic stability Unique selectivity complementary to the C8 column Novel polar-embedded column chemistry for hydrolytic stability Compatible with % aqueous mobile phase bleed for MS compatibility Wide range of applications Acclaim PolarAdvantage II (PA) columns feature a patented surface chemistry that incorporates an amide-embedded polar group and multi-point attachment between the ligands and the silica surface. This unique chemistry provides enhanced hydrolytic stability from ph.5- with % aqueous mobile phases and exhibits high reversed-phase capacity, with selectivity complementary to conventional C8 columns. The Acclaim PA column is specifically designed to withstand high ph conditions, making it a good choice for the separation of both basic and acidic analytes..5 Å 6 5 Particle Size.μm, μm, 5μm USP L6 Turmeric,, mau C8 Area: 9.7 mau*min. Total area: 9.9 mau*min. PA Mobile Phase A: 5mM H PO Mobile Phase B: Methanol Isocratic: C8: 7% B (v/v) PA: 8% B (v/v) Temperature: C Flow Rate:.mL/min Detection: UV, 8nm Analytes:. Curcumin. Demethoxycurcumin. Bis-demethoxycurcumin Sample: Turmeric extract Thermo Scientific Chromatography Columns and Consumables 6-7 Acclaim PolarAdvantage II Particle Size (μm) Format Length (mm).mm ID.mm ID.6mm ID. RSLC Column 7 769-5 68989 768-6899 767-5 7 - - 5 78 - - HPLC Column - 6676-5 77999 6897 689 75-6677 - 77998 78 78 5 687 675 69 5 77997 78-5 Guard Cartridge 6969 7985 69699 HPLC Column 5 - - 697 5 - - 699 See page -7 for Ordering Guide -

pa Acclaim HILIC- Designed with unique selectivity for hydrophilic molecules Retains highly polar molecules that are not retained by reversed-phase chromatography Unique selectivity, complementary to reversed-phase columns Hydrolytically stable Rugged column packing Broad application range The Acclaim HILIC- column is designed for separating highly hydrophilic molecules by Hydrophilic Interaction Liquid Chromatography (HILIC). This column is based on high-purity spherical porous silica covalently modified with a proprietary hydrophilic layer. Glycerides 5 6 7 8 Mobile Phase A: Heptane Mobile Phase B: -Propanol/acetic acid 99.5:.5 Temperature: 5 C Flow Rate:.5mL/min Injection Volume: μl Detection: Corona ultra, nebulizer 5 C Analytes:. Tristearin. Trilaurin. Distearin isomer. Dilaurin isomer 5. Distearin isomer 6. Dilaurin isomer 7. Monostearin 8. Monolaurin to 8 Å Particle Size μm, 5μm LC Columns and Accessories >> Acclaim 6 8 Acclaim HILIC- Particle Size (μm) Format Length (mm).mm ID.mm ID.6mm ID HPLC Column 5 759 758 757 5 Guard Cartridge 76 76 76 Format Acclaim Guard Cartridge Holder V- 6958 Acclaim Guard Kit (Holder and Coupler) V- 6977 Guard to Analytical Column Coupler V- 788 www.thermoscientific.com/chromatography -

Acclaim Mixed-Mode HILIC- Uniquely designed for both reversed-phase and HILIC operations Can operate in both RP and HILIC modes Retains highly polar molecules Unique selectivity complementary to RP columns Broader application range compared with conventional diol-based columns -efficiency column for high-resolution separations The Acclaim Mixed-Mode HILIC- column features a unique, high-efficiency, silica-based HPLC mixed-mode stationary phase that combines both reversed-phase (RP) and hydrophilic interaction liquid chromatography (HILIC) properties. This combination allows both hydrophobic and hydrophilic interactions to be utilized to optimize separations. The functional group is of a hydrophobic alkyl chain with a diol group at the terminus. This unique combination results in the adjustable selectivity, making Acclaim Mixed-Mode HILIC- separate mixtures that would be impossible for a C8 column. This column is suitable for a broad range of applications, including non-ionic ethoxylated surfactants, drug metabolites, lipids, polyethylene glycols (PEGs), ethoxylated surfactants, and more..5 to 7.5 Å Particle Size μm, 5μm Cytosine and naphthalene AU Reversed-Phase Mode HILIC Mode Mobile Phase: CH CN/. M NH OAc, ph 5. v/v 5/8 for RP mode v/v 9/8 for HILIC mode Temperature: C Flow Rate: ml/min Injection Volume: μl Detection: UV, 5nm Analytes:. Cytosine ( ppm). Naphthalene ( ppm) 6 8 Thermo Scientific Chromatography Columns and Consumables 6-7 Particle Size (μm) Format Length (mm).mm ID.mm ID.6mm ID HPLC Column 5-79 - 5 79 79-5 Guard Cartridge 6969 79 6976 HPLC Column 5 6687-668 5 - - 668 Format Acclaim Guard Cartridge Holder V- 6958 Acclaim Guard Kit (Holder and Coupler) V- 6977 Guard to Analytical Column Coupler V- 788 -

Acclaim Mixed-Mode WAX- Designed for separating anionic molecules with powerful adjustable selectivity control Adjustable selectivity Selectivity orthogonal to reversed-phase (RP) columns Ideal selectivity for anionic molecules Excellent column efficiency and peak asymmetry Multimode retention mechanisms: reversed-phase, weak anion exchange, and HILIC modes The Acclaim Mixed-Mode WAX- is a novel, high-efficiency silica HPLC column that combines hydrophobic and weak anion exchange characteristics. Its unique chemistry results in a multimode separation mechanism that includes reversed-phase, anion exchange, and HILIC interactions. Selectivity can be adjusted by changing ionic strength, ph or organic solvent content. AU O OH OH Mobile Phase: /6 v/v Acetonitrile/buffer (6.8 g potassium monophosphate and.5 g pyrophosphate in g D.I. H O, ph is adjusted to 6. with NaOH) Temperature: C Flow Rate: ml/min Injection Volume: μl Detection: UV, nm Analytes:. Caffeine. Acetaminophen. Salicylamide. Acetyl salicylic acid (Aspirin) 5. Salicylic acid.5 to 7.5 Å Particle Size μm, 5μm USP L78 LC Columns and Accessories >> Acclaim 5 Particle Size (μm) Format Length (mm).mm ID.mm ID.6mm ID HPLC Column 5-798 - 5 789 788-5 Guard Cartridge 69686 799 697 HPLC Column 5 678-698 5 - - 6985 Format Acclaim Guard Cartridge Holder V- 6958 Acclaim Guard Kit (Holder and Coupler) V- 6977 Guard to Analytical Column Coupler V- 788 www.thermoscientific.com/chromatography -

Acclaim Mixed-Mode WCX- Designed for separating cationic molecules with adjustable selectivity control Adjustable selectivity Ideal selectivity for separating basic molecules Selectivity complementary to C8 RP columns Multimode separation mechanism: reversed-phase, weak cation exchange, anion-exclusion and HILIC The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column, with a proprietary ligand with both hydrophobic and weak cation exchange properties. Selectivity of ionizable and neutral compounds can be controlled independently or simultaneously by tuning mobile phase ionic strength, ph or organic modifier. This column therefore can separate using multiple separation modes: reversed-phase, cation exchange, and normal-phase/ HILIC and is recommended for a variety of industrial applications, including pharmaceutical, chemical, consumer products, foods and beverages..5 to 7.5 Å Particle Size μm, 5μm USP L78 Pharmaceutical counterions AU 5 6 7 Mobile Phase: /6 v/v CH CN/NH OAc, ph 5. ( mm total) Temperature: C Flow Rate: ml/min Injection Volume: 5μL Detection: UV (5 nm) Analytes:. Maleate 5μg/mL. Ketoprofen μg/ml. Naproxen μg/ml. Hydrocortisone 6μg/mL 5. Dexamethasone 6μg/mL 6. Oxprenolol μg/ml 7. Timolol 5μg/mL 8 Thermo Scientific Chromatography Columns and Consumables 6-7 Particle Size (μm) Format Length (mm).mm ID.mm ID.6mm ID HPLC Column 5-79 - 5 79 79-5 Guard Cartridge 8555 79 6975 HPLC Column 5 687-685 5 - - 685 Format Acclaim Guard Cartridge Holder V- 6958 Acclaim Guard Kit (Holder and Coupler) V- 6977 Guard to Analytical Column Coupler V- 788 -

Acclaim Size Exclusion Chromatography (SEC) performance SEC columns for analysis of water soluble polymers Proprietary mono-dispersed multi-pore hydrophilic resin: no inflection points in calibration curve SEC- calibrated from to 5, Daltons SEC- calibrated from, to,, Daltons Availability of small particle sizes packed in x.6mm dimension allows for high-resolution analysis at reduced solvent consumption Stable surface bonding with low column bleed and compatibility with UV, RI, MS, ELSD and Thermo Scientific Dionex Corona Charged Aerosol Detectors Thermo Scientific Acclaim SEC- and SEC- are a family of resin based, high performance size exclusion chromatography columns specifically designed for the separation of water soluble polymers and oligomers. Å (SEC ) Particle Size 5, 7μm to Å (SEC ) 5,, Molecular Weight (Da),,,,,, SEC- SEC- Mobile Phase: mm sodium perchlorate Temperature: 5 C Flow Rate:.5mL/min Injection Volume: 5μL Detection: RI Analytes: (.% -.% in mobile phase) dextran (MW 5,,-,,), PEO (MW 895,, 58,, 7,, 85,, 8,,,, and,), PEG (MW 8,,,,,5, 6, and ), diethylene glycol (MW 6 and ethylene glycol (MW 6).5..5..5..5 Elution Volume (ml) Thermo Scientific Chromatography Columns and Consumables 6-7 -6.5 pa -. PAA μg/l μg/l μg/l 5 μg/l 5 μg/l 5 5.5. Polyacrylic acid Area [ pa *min] Concentration [ μg/l].c 5 5 75 5 Mobile Phase A: Acetonitrile Mobile Phase B: Water Temperature: C Flow Rate:.5mL/min Injection Volume: 5μL Detection: Corona III; evaporator 55 C, Engine C, Hz, filter 5, power function. Analytes:. PAA standards in water Description Particle Size (μm) Format Length (mm).6mm ID 7.8mm ID Acclaim SEC- 5 Guard 87 HPLC Column 5 7976 797 7975 Acclaim SEC- 7 Guard 879 HPLC Column 5 797 797 797

Acclaim C8 -resolution reversed-phase separation of proteins and peptides Designed for high-resolution peptide mapping and protein separations Application tested for suitability in peptide mapping Reproducible for dependable results LC-MS compatible Ultrapure silica with low metal content and exhaustive bonding and endcapping Budesonide and related substances mau FS mau FS Acclaim C8 5 7 5 6 9 5 8 Acclaim C8, μm, 5 x.6mm Mobile Phase A: Acetonitrile:ethanol 5: Mobile Phase B:.% phosphoric acid Isocratic 66% B Temperature: C Flow Rate:.mL/min Injection Volume: 5μL Detection: UV, nm Sample: Budesonide, 5μg/mL after three days Analytes: 7, 8. Budesonide epimers, 99% Reference: Hou S, Hindle M, Byron PR; J. Pharm. Biomed. Analy. :7-8. Particle Size (μm) Format Length (mm).mm ID.mm ID.6mm ID HPLC Column 5 66 665 5 66 668 666 5 Guard Cartridges (/pk) 6969 757 69697.5 to 7.5 8 5 Particle Size μm USP L BioLC Columns and Accessories >> Protein Reversed Phase Description Cat. No. Acclaim SST Guard Cartridge Holder V- 6958 Acclaim Guard Kit (Holder and Coupler) V- 6977 Guard to Analytical Column Coupler V- 788 www.thermoscientific.com/chromatography -7