Automatic titrators, TitroMatic

Similar documents
Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

USER MANUAL. Aquamax TAN

Concise laboratory catalogue

Titrex ACT titrators have been designed to simply and precisely satisfy and perform the widest range of potentiometric titrations: acid-base, redox,

Karl Fischer Titrator

Karl-Fischer Titration the method for determining water

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

From 1 ppm to 100% Karl Fischer water content determination

Compact Titration Compact Titrator G20. One Click Titration Simple & Dependable

Titration Catalog. Systems and Autosampler

The first address for Titration. TITRONIC 300 and TitroLine 5000

Easy and reliable KF titrations From 1 ppm to 100%

Mobile coulometer for water determination anywhere you want

Operating Instructions. Titration Excellence Terminal

Reagents - Install/Replace. Select method/sequence. KF Reagent calibration Running KF titration methods. Running SAC sequences

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

Process Instrumentation analyzers

PAA-ANALYZERS PRINCIPLE OF OPERATION

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Kjeltec 2300 Analyzer Unit

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

473-SHX Dew Point Mirror

ph/redox Measurement CPM 280

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

473 Dew Point Hygrometer

12.01 Determination of the isoelectric point of an amino acid (glycine)

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

One-hand ph/temperature measuring instrument

473 Dew Point Hygrometer

Electrochemistry LEC Potentiometric ph titration (phosphoric acid in a soft drink) What you need: What you can learn about

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

Automatic Potentiometric Titrator

ADI 2040 Process Analyzer

JAPAN QUALITY. Automated Clinical Analyzer

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz

ISEmax CAM40/CAS40. Technical Information

Titration of a strong acid with a strong base with Cobra4

Heat stress index. Dewpoint. pressure. altitude

Operating Instructions for Digital Manometer. Model: MAN-SD

Compact ph Measuring Instruments With Pro Engineering

610,- KERN ADB. Analytical balances. Quick-Finder Analytical balances. Large glass draught shield with 3 sliding doors

Application Bulletin

Electrodes - Connect/Replace. Reagents - Install/Replace. Select method ph electrode calibration. Reagent calibration.

Operating Instructions. METTLER TOLEDO DL77 / DL70ES / DL67 Titrators RESET EXIT RUN

STANDARD OPERATING PROCEDURE

Our Drop Counter sensor now features housing for two electrode sensors, an anti-twist mechanism, an indicator LED and two cable guides.

Kestrel 4500 Pocket Weather Tracker

P S H - S 3G m t e e t r e (C ( E mar ar e k d e ) P B H - B 4 - Por or ab ab e l PH M t e e t r

ION SELECTIVE MEASUREMENT

Automated Clinical Analyzer

CTC 155 / 350 / 660 Dry-block calibrator

2100TR Liquid Scintillation Counter

La nueva línea de tituladores y buretas

Metz Syn 10 Reaction Station

The Clinical Chemistry System that offers more so you do less!

CHEMISTRY WORKSTATION. The power of proven quality GIVING YOU PEACE OF MIND

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Operating Instructions. EasyPlus Titration Easy ph / Easy Ox / Easy Cl / Easy Pro

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

VIBRATION METER. Instruction Manual.

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX

JAPAN QUALITY. Automated Clinical Analyzer

DSA 5000 M. Density and Sound Velocity Meter. ::: Unique Density & Concentration Meters

Thermochemistry/Calorimetry. Determination of the enthalpy of vaporization of liquids LEC 02. What you need: What you can learn about

Instruction Manual Portamess 911 ph

PTG-NIR Powder Characterisation System (not yet released for selling to end users)

Experiment C-10 Titration of a Strong Acid and a Strong Base

Metso Concentration Measurement 3300

PC Control / Touch Control

Potentiometric measurement of ph

ED 701 General Industry Pressure Transmitter

PURCHASE DIVISION DEPARTMENT QUALITY MANUAL. CPRI Section II -Technical Specification

ph / Temperature Meter for Cheese with Application Specific Probe

INE-PHS-3E ph Meter Operating Manual

Technology that counts

PHS-25CW/3BW Benchtop ph Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Conductivity sensor for hygienic applications

Bante210 Benchtop ph Meter Instruction Manual

MULTIFUNCTION COMPUTER METER CX-742 USERS MANUAL

Electrochemistry. Conductivity of strong and weak electrolytes LEC 06. What you need: What you can learn about. Principle and tasks

Automatic Potentiometric Titrator [AT-710S]

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Thermo Scientific Orion Star T900 Series Laboratory Titrators. Potentiometric titrators for performing automated ph, redox, or ion titrations

OPTION. Karl Fischer Moisture Titrator [Volumetric titration] Karl Fischer Moisture Titrator [Coulometric titration]

Operating Instructions. EasyPlus Titration Easy KFV

RheolabQC. Rotational Rheometer for Quality Control. ::: Intelligence in Rheometry

Technology that counts

Vaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance

Hot solutions for temperature measurement. Contact and non-contact thermometers from Fluke

Conductometric Titration & Gravimetric Determination of a Precipitate

Dewpoint Meter Data Sheet / Instructions

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

ph/o.r.p. probe Type 8619 multicell transmitter/controller General data Measuring range Bürkert ph probe Bürkert O.R.P. probe Medium temperature

St art. rp m. Km /h 1: : : : : : : : : : : : :5 2.5.

Data Sheet / Instructions. Dewpoint MeterO

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

Experimental Procedure

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Transcription:

112 TitroMatic These are the fourth generation of CRISON titrators. CRISON has over 25 years experience in this field and knows that, for certain applications, the performance and cost of large titrator are not always justified. CRISON s TitroMatics are effective and economical titration systems and are extremely useful for routine determinations. There is a TitroMatic model for every application. We have versions for both universal and specific applications. TitroMatic 1S and 2S burettes TitroMatic burettes all have a precision mechanism which is actioned by a stepper motor. In the TitroMatic 1S, the motor stroke is subdivided into 40,000 steps and the mechanism moves the plunger of the syringe. A quick-switch electrovalve controls the in- and outlet of liquid from the syringe. In the TitroMatic 2S, the two syringes are actioned by a single mechanism. Only one reagent is dispensed: the one from the valve which has been activated. The other syringe will return the reagent to the original bottle. When the second reagent is not in frequent use, it is a good idea to free up the corresponding syringe. Peristaltic pumps, depending on version These are integrated in the back panel of the TitroMatic or in a separate module, 86 90. They can either add auxiliary reagents before or during titration or draw up any remaning sample during the automatic levelling process.

113 Main functions Titrations: - Defined End Point (DEP). - Equivalence Point Calculation, EPC. - Reaction Study (RS). Burette calibration. How do they perform titration? DEP Mode, Defined End Point. The instrument adds reagent until a known and previously-selected ph or mv value is attained. Reagent is added continuously. The titrator adapts the flow rate of the titrant reagent according to the area of titration, in order to attain the end point quickly. This is a rapid type of titration, frequently used in quality control applications. EPC Mode, Equivalence Point Calculation. The user only needs to know in which area the equivalence point of a reaction is to be found. The titrator will add reagent quickly until the area is reached and once there will calculate exactly the equivalence or inflection point of the titration. This is very useful in mv titrations, e.g. argentometry, where the equivalence point is always detected in the same area but where the exact potential may vary depending on electrode wear. RS Mode, Reaction Study. The instrument studies the behaviour of a sample during titration, so as to optimise later titration of this kind of sample. EPD: the flow rate decreases as the ph comes closer to the End Point. Fig. A. The EPC, equivalence point calculation, is 120 mv Fig. B. The equivalence point calculation, has moved to 160 mv Sample dosing without pipette: automatic levelling Using a TitroMatic equipped with peristaltic pumps, either integrated or using external model 86 90, the user need no longer pipette large volumes of sample. Polypropylene vessels, of identical shape and size, are used for this. The user need only pour an approximate amount of the sample in the vessels and the levelling system will draw up any excess, adjusting the volume exactly. Reproducibility over 1%. RS: Study of a reaction from a sample

114 TitroMatic (continued) Titromatic 1S 1S-2B 2S 2S-2B Elements Syringes 1 1 2 2 Pumps - 2-2 their function Universal versions There are several versions, the differences among them being the elements they include. Thus: One titrant ready Two titrants ready - - Double dosing of reagent - - Dosing sample without pipette - - Dispensing auxiliary reagents - - Automatic sensors cleaning - - Two RS 232 C interfaces: One bi-directional to printer or PC. Another for connection to any CRISON automatic sample changer. Data Logger, storage of results which can be queried on screen, printed or sent to a PC at any time. Real-time clock calendar Connectable peripherals Sensors: ph and redox electrodes ion selective electrodes photoprobes temperature probe (Pt 1000) Bar-code scanner Magnetic stirrer Separate peristaltic pump module 86 90 PC keyboard PC or printer Sampler or Balance The 86 90 separate pump can be connected to all versions. Key features common to all TitroMatics They can store different titration programmes Self-test programme, for calibrating the burette in the user s own laboratory. Syringes: 10 ml standard. 2.5 and 5 ml optional. Versions 2S, with 2 syringes, can also be turned into a 20 ml burette, by adding 2 10-ml syringes. Two TitroMatics can be connected to the same Sampler at the same time. Precision ph-meter. ph calibration with criteria for rejecting electrodes in poor condition. Re-calibration warning once the programmed time is exceeded. Backlit, liquid crystal graphic display. Highly-functional, long-life keypad. Connection for external PC keyboard, making it easier to add text such as report headers, sample code, users, etc.

115 External pump module 86 90 Display examples Measurement of ph and temperature. Titration reagent load on first startup The automation of certain processes sometimes requires the use of one or several peristaltic pumps. The 86 90 pump can be fitted to all versions of the TitroMatic. Printer 82, optional The results obtained, programmes in memory, etc., can be printed out on a printer, see examples. Calibrating ph. Second point 4.01 One of the screens, after calibration. Calibration data, second screen During titration End of titration TiCom software for data capture from a PC TitroMatics can be connected directly to a PC. The TiCom Programme, developed by CRISON, makes it easy to use. For further information, please see page 130

116 TitroMatic (continued) Technical specifications common to universal and specific TitroMatic Non-volatile memory Up to 5 titration programs with the TitroMatic 1S. Up to 10 with the TitroMatic 2S. Burette auto-calibration program. Clock / calendar. Header texts: 2 lines x 40 characters. Name of up to 4 operators. Program comments: 8 lines x 40 characters. Up to 50 results stored in the Data Logger. Languages Display Keypad English, spanish, french, italian. Graphic backlit liquid crystal display, 128 x 64 dots. Measuring ranges ph -2... 16, mv ± 2000, ºC -20... 150. Resolution Measuring error (±1 digit) Reproducibility (±1 digit) Temperature compensation ph calibration Membrane, 7 keys. Protected PET material. Guaranteed for up to 6 million strokes per key. 0.01 ph, 1 mv, 0.1ºC. 0.01 ph, 1 mv, 0.2ºC. ±0.01 ph, ±1 mv, ±0.1ºC. With ATC Pt 1000 probe or entering data using the keypad. Syringe volume Standard 10 ml. Optional: 5 and 2.5 Resolution Dispensing accuracy Reproducibility of the dispensing Materials in contact with the liquid Inputs and outputs Power supply In 1, 2 or 3 points, validity 0 h 7 days. Automatic recognition of technical buffers. ph 2.00, 4.01, 7.00, 9.21 and 10.90 (at 25ºC). Special calibration, 1 selectable point between 0 14 ph. Accepted electrode values: Slope 50... 65 mv/ph, at 25 ºC. Sensitivity 86... 110%. Asymmetry potential ± 40 mv. Rejection of defective electrodes. Expired calibration warning. 1/40000 of the syringe volume. Electrical safety Meets EC, EN 61010. (as relative error) 0.2% for volumes higher than 10 % of the syringe. ±0.1% for volumes higher than 10 % of the syringe. Syringe: glass borosilicate and PTFE. Electrovalve: PTFE and KEL-F. Tubes: PTFE. Measuring electrode, BNC connector. Reference electrode, banana Ø 4. ATC, Pt 1000 type, telephone connector or banana Ø 4. External keyboard, minidin connector. RS 232C bidirectional for PC or printer, telephone connector. RS 232C, for Sampler or balance, telephone connector. Stirrer control: On/Off and speed, RCA connector External pump control, telephone connector 24 VAC, 1.25A, 30 VA external power supply. EMC (Electromagnetic compatibility) Meets EC, EN 50081-2 and EN 50082-2. Permitted ambient conditions Enclosure Physical parameters Specifications subject to change without notice Certificates Supplied with the EC Declaration of Conformity as per directive EMC 89/336/EC, and specifications certificate. For further information, please see page 132. Operating temperature, 10...40 C. Storage and transport temperature, 10...50 C. 80%, relative humidity, non condensing. ABS and enamelled steel. Weight: 4 kg approx. Dimensions: 130 x 160 x 300 mm. Equipment composition Code Instrument Syringes Pumps Electrode ATC 86 50 TitroMatic 1S, universal 1 - - - 86 51 TitroMatic 1S 2B, universal 1 2 - - 86 60 TitroMatic 2S, universal 2 - - - 86 61 TitroMatic 2S 2B, universal 2 2 - - PLUG-IN POWER SUPPLY: The instrument is supplied with a 230 VAC plug-in power supply. For 115 VAC, please specify when ordering SENSORS: Universal TitroMatics are supplied without sensors. Select the ones most appropriate for your application, see pages 36 ACCESSORIES: TitroMatics include a stirrer, a sensor support, electrode cable and a set of buffer and electrolyte solutions. OPTIONAL ACCESSORIES: Sampler, printer, etc. See page 127