Infrared Tire Temperature Sensor Kit, IRTS-UK-V2 Datasheet

Similar documents
Infrared Tire Temperature Sensor, IRTS-V2 - Datasheet

Infrared Temperature Sensor - Datasheet

Multichannel Brake Infrared Temperature Sensor - Datasheet

DATA SHEET. Thermocouple module with digital I²C-Interface - THMOD-I²C. Characteristic features. Areas of application. Features.

Data byte 0 Data byte 1 Data byte 2 Data byte 3 Data byte 4. 0xA Register Address MSB data byte Data byte Data byte LSB data byte

Installation Instructions: ICON Anti-Condensate Controller

Load Washers. Force kn until kn. Type 9101A A

SHM-14 Ultra-Fast, 14-Bit Linear Monolithic Sample-Hold Amplifiers

MAGPOWR TENSION CONTROL DLCA NET-SLIM. User Manual. Digital Load Cell Amplifier MI 850A358 1 A

ENSC387: Introduction to Electromechanical Sensors and Actuators LAB 3: USING STRAIN GAUGES TO FIND POISSON S RATIO AND YOUNG S MODULUS

Operating Instructions for Digital Manometer. Model: MAN-SD

user's manual nx frequency converters resolver option board opt-bc

GS110. IR Thermal Imaging System for Low-Emissivity Glass with Automatic Emissivity Correction. Manual Addendum

MODBUS Protocol for CS141 network card families

Preliminary Product Information. LIC 4000 Series Exposed Absolute Linear Encoders

About the Sens it Payload

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

St art. rp m. Km /h 1: : : : : : : : : : : : :5 2.5.

Application example. Measuring Force Sensors Rigid. Six series Nano, Mini, Gamma, Delta, Theta, Omega. Range of measurement, force ± 36 N..

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

IDENTIFICATION STS400

BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

POINTS OF CAUTION BEFORE USE...

Load Washers. Force. for Forces of 7, kn. F z. Type 9001A A 9081B, 9091B

Differential Pressure Sensor

OPERATING MANUAL. EIB-Kombisensor AS 315 N

HD2016. [ GB ] Weighing rain gauge. Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION

The gauge factor of a strain gauge relates strain to change in electrical resistance. The gauge factor G F is defined by the formula.

E2T0 DVP

I2 C Compatible Digital Potentiometers AD5241/AD5242

32 Input AC Block I/O Module

Size A DIN EN

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

PRODUCT OVERVIEW REF. IN 16 BIPOLAR OFFSET 17 REGISTER 74LS75 REGISTER 74LS75 BITS LSB

DESCRIPTION FEATURES APPLICATIONS. Audio Processor IC

MS4525HRD (High Resolution Digital)

Pin & Socket Connectors

DATASHEET AD7520, AD7521. Features. Ordering Information. Pinouts. 10-Bit, 12-Bit, Multiplying D/A Converters. FN3104 Rev.4.

HIGH CURRENT BRIDGE DRIVER and 4-20mA Transmitter

What You Need to Get Started INSTALLATION GUIDE

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

Electronic Instrumentation. Project 2 Velocity Measurement

Pressure transmitters for industrial applications MBS 32 and MBS 33

Data Logger V2. Instruction Manual

AN6783S. IC for long interval timer. ICs for Timer. Overview. Features. Applications. Block Diagram

- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen

S P E C I F I C A T I O N

16 Input AC Block I/O Module

100K SLQ1 OP2 R207. Future option SLQ2 OP2 R307. Future option

RoHS. Versatile. X g. X 2 e

Display counter electromechanical

3 Channel Constant Current DMX LED Driver

VFD- RoHS Compliant M0116MY-161LSBR2-1. User s Guide. (Vacuum Fluorescent Display Module) For product support, contact

Using a Mercury itc with thermocouples

89BSD CALCULATION METHOD APPLICATION NOTE

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

Alignment Tools Used To Locate A Wire And A Laser Beam In The VISA Undulator Project

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08

SKA COMPACT. ALL IN ONE Linear Axes

Differential indicators

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMX-controlled motorised shutters

Old Dominion University Physics 112N/227N/232N Lab Manual, 13 th Edition

MS4525HRD (High Resolution Digital) Integrated Digital Pressure Sensor (24-bit Σ ADC) Fast Conversion Down to 1 ms Low Power, 1 µa (standby < 0.15 µa)

CANBUS-THERMO-2CH Rev B v Channel CAN-Bus Thermocouple Interface K-Type. V1.0 July SK Pang Electronics Ltd

KH600. 1GHz, Differential Input/Output Amplifier. Features. Description. Applications. Typical Application

100K SLQ1 OP2 R207. Future option SLQ2 OP2 R307. Future option

EXPERIMENT NO. 4. Thermal Radiation: the Stefan-Boltzmann Law

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC6H 400-S/SP1

MCP Scrubber Monitoring

all stainless steel transducer multimedia compatibility

Gurley Model A58 Absolute Encoder

Maintenance/ Discontinued

800mA and 1A Low Dropout Positive Regulator 2.85V, 3V, 3.3V, 5V, and Adjustable

Arduino Weather Station And Ascom Observing Conditions

User Manual. 1000BASE-T1 SFP Module

CDS. high density spring connection

Project. Project Location. Catalog #

MS BA Miniature 30 bar Industrial Pressure Sensor

DVSA2800D Series HIGH RELIABILITY HYBRID DC-DC CONVERTERS DESCRIPTION FEATURES

FOR MESSRS : DATE : Oct. 26 th,2017 TECHNICAL DATA TX16D201VM0BAB. Contents

Introduction. Pre-lab questions: Physics 1BL KIRCHOFF S RULES Winter 2010

Single point load cells

VMS-GeoMil. Background

ME 4/549 Lab Assignment 5: Single Block Experiment Spring 2006 due 1 June 2006

July 11, Capacitor CBL 23. Name Date: Partners: CAPACITORS. TI-83 calculator with unit-tounit. Resistor (about 100 kω) Wavetek multimeter

CPE100: Digital Logic Design I

Q-Motion Precision Linear Stage

IH5341, IH5352. Dual SPST, Quad SPST CMOS RF/Video Switches. Description. Features. Ordering Information. Applications. Pinouts.

FLOW SENSOR FOR LIQUID MEDIA Serie 210

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

Series FEATURES AND BENEFITS INTRODUCTION. Figure 1 Power Derating Curve. Table 1 Tolerance and TCR vs. Resistance

Silicon Temperature Sensors KT 100 KT 110 KT 130 KT 210 KT 230. KTY 11-x KTY 13-x KTY 21-x KTY 23-x KTY 19-6 KTY 16-6

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC5FW 500-S

User s Manual: MODEL 904-T CLINOMETER PAK

Simple circuits - 3 hr

Direct-operated 2/2-way compact solenoid valves Type EV210A

Resistance : R = ρ( ) units are Ohms ( 14 ) Resistor 100 ohms

IRTS-P PRECISION INFRARED TEMPERATURE SENSOR INSTRUCTION MANUAL

Transcription:

The Izze-Racing infrared sensor is specifically designed to measure the highly transient surface temperature of a tire with spatial fidelity, providing invaluable information for chassis tuning, tire exploitation, and driver development. Each sensor is capable of measuring temperature at 16, 8, or 4 laterally-spaced points, at a sampling frequency of up to 100Hz, object temperature between -20 to 300 C, using CAN 2.0A protocol, enclosed in a compact IP66 rated aluminum enclosure, and priced to be affordable to all tiers of motorsport. The sensor is now offered as a complete kit for any data acquisition system that can log CAN messages. The kit includes four 4, 8, or 16-channel infrared tire temperature sensors with wide (60 ) or ultra-wide (120 ) field-of-views and a complete motorsport-grade wiring harness. SENSOR SPECIFICATIONS Temperature Measurement Range, T o -20 to 300 C Package Temperature Range, T p -20 to 85 C Accuracy (Central 10 Channels, Nominal) (16-Ch Sensor) ±1.0 C for 0 C < T p < 50 C ±2.0 C for T p < 0 C and T p > 50 C Accuracy (First & Last 3 Channels, Nominal) (16-Ch Sensor) ±2.0 C for 0 C < T p < 50 C ±3.0 C for T p < 0 C and T p > 50 C Noise Equivalent Temperature Difference, NETD 0.5 C at 16Hz, ε = 0.85, T o = 25 C Field of View, FOV 60 x 8 (wide) 120 x 15 (ultra-wide) Number of Channels 16, 8, or 4 Sampling Frequency 100 1, 64 1, 32, 16, 8, 4, 2, or 1Hz Thermal Time Constant 2 ms Effective Emissivity 0.01 to 1.00 (default = 0.78) Spectral Range 8 to 14 µm 1 Optional Extra, 64Hz limit for IRTS-120-V2, 100Hz limit for IRTS-60-V2 ELECTRICAL SPECIFICATIONS (SENSOR) Supply Voltage, V s 5 to 8 V Supply Current, I s (typ) 30 ma Features Reverse polarity protection Over-temperature protection (125 C) MECHANICAL SPECIFICATIONS (SENSOR) Weight L x W x H (max, 60 FOV) L x W x H (max, 120 FOV) Protection Rating 20 g 36.6 x 26.0 x 12.3 mm 31 x 29.0 x 12.3 mm IP66 Page 1 of 9

CAN SPECIFICATIONS Standard Bit Rate Byte Order Data Conversion Base CAN ID s (Default) Termination CAN 2.0A (11-bit identifier), ISO-11898 1 Mbit/s Big-Endian / Motorola 0.1 C per bit, -100 C offset, unsigned LF Sensor: 1200 (Dec) / 0x4B0 (Hex) RF Sensor: 1204 (Dec) / 0x4B4 (Hex) LR Sensor: 1208 (Dec) / 0x4B8 (Hex) RR Sensor: 1212 (Dec) / 0x4BC (Hex) None CAN ID: Base ID Channel 1 Channel 2 Channel 3 Channel 4 Byte 0 (MSB) Byte 1 (LSB) Byte 2 (MSB) Byte 3 (LSB) Byte 4 (MSB) Byte 5 (LSB) Byte 6 (MSB) Byte 7 (LSB) CAN ID: Base ID+1 Channel 5 Channel 6 Channel 7 Channel 8 Byte 0 (MSB) Byte 1 (LSB) Byte 2 (MSB) Byte 3 (LSB) Byte 4 (MSB) Byte 5 (LSB) Byte 6 (MSB) Byte 7 (LSB) CAN ID: Base ID+2 Channel 9 Channel 10 Channel 11 Channel 12 Byte 0 (MSB) Byte 1 (LSB) Byte 2 (MSB) Byte 3 (LSB) Byte 4 (MSB) Byte 5 (LSB) Byte 6 (MSB) Byte 7 (LSB) CAN ID: Base ID+3 Channel 13 Channel 14 Channel 15 Channel 16 Byte 0 (MSB) Byte 1 (LSB) Byte 2 (MSB) Byte 3 (LSB) Byte 4 (MSB) Byte 5 (LSB) Byte 6 (MSB) Byte 7 (LSB) WIRING SPECIFICATIONS (SENSOR) Wire Cable Length (typ.) Connector 26 AWG M22759/32, DR25 jacket 500 mm Deutsch DTM 4P (gold contacts) Supply Voltage, V s Red (Pin 3) Ground Black (Pin 4) CAN + Blue (Pin 2) CAN - White (Pin 1) (twisted) (twisted) Page 2 of 9

SENSOR CONFIGURATION: To modify the sensor s configuration, send the following CAN message at 1Hz for at least 10 seconds and then reset the sensor by disconnecting power for 5 seconds: CAN ID: Current Base ID Programming Constant New CAN Base ID (11-bit) Emissivity Sampling Frequency Channels Byte 0 (MSB) Byte 1 (LSB) Byte 2 (MSB) Byte 3 (LSB) Byte 4 Byte 5 Byte 6 Byte 7 30000 = 0x7530 1 = 0x001! 2047 = 0x7FF 1 Optional Extra, 64Hz limit for IRTS-120-V2, 100Hz limit for IRTS-60-V2 1 = 0.01! 100 = 1.00 1 = 1Hz 2 = 2Hz 3 = 4Hz 4 = 8Hz 5 = 16Hz 6 = 32Hz 7 = 64Hz 1 8 = 100Hz 1 CAN messages should only be sent to the sensor during the configuration sequence. DO NOT continuously send CAN messages to the sensor. 40 = 4Ch 80 = 8Ch 160 = 16Ch DIMENSIONS: 60 Field-of-View, IRTS-60-V2 120 Field-of-View, IRTS-120-V2 Page 3 of 9

Field of View (FOV): 16-Channel 8-Channel 4-Channel 60 Field-of-View, IRTS-60-V2: (Approximate. Angle offset (z-axis rotation) between -5 and +5, mounts should allow adjustment accordingly) Page 4 of 9

120 Field-of-View, IRTS-120-V2: (Approximate. Angle offset (z-axis rotation) between -5 and +5, mounts should allow adjustment accordingly) Page 5 of 9

WIRING SPECIFICATIONS (HARNESS): Wire Cable Length (typ.) Connectors 22 AWG M22759/32, DR25 jacket, ATUM boots 1.8-2.1m trunk segments, 0.5m branches Deutsch DTM 4P (gold contacts) Supply Voltage, V s Red (Pin 3) Ground Black (Pin 4) CAN + Blue (Pin 2) CAN - White (Pin 1) (twisted) (twisted) The default wiring harness layout is shown in the first diagram below and is designed for data loggers without an internal CAN terminating resistor (MoTeC, Cosworth, Bosch, Stack, 2D, AEM, RaceCapture/Pro systems). o The harness can be modified upon request for data loggers with an internal CAN terminating resistor (AiM systems). The layout of this harness is shown in the second diagram below. The harness needs to be powered with 5-8 volts (120mA) but may be extended to 6.5-36 volts upon request. The CAN terminating resistors are integrated into the short Deutsch DTM connectors. Resistor value is 120Ω. Female pins for MoTeC Tyco/AMP Superseal connectors or female pins (38943-22) for AS Deutsch Autosport connectors (e.g., AS620-35SN connector for C185, C187, L180, ADL/EDL) may be added to the flying leads for the data logger upon request. Additional CAN sensors (strain gauge amplifiers, brake temperature sensors, etc.) may be added to the harness by using a y-harness at each corner. Harness lengths may be modified upon request. Please contact us if you would like to modify the wiring harness / kit; we are glad to accommodate your specific requirements. Page 6 of 9

DEFAULT WIRING HARNESS LAYOUT: (Data logger without internal CAN terminating resistor) Page 7 of 9

ALTERNATIVE WIRING HARNESS LAYOUT: (Data Logger with internal CAN terminating resistor) Page 8 of 9

ADDITIONAL INFORMATION: Stated accuracy is under isothermal package conditions; for utmost accuracy, avoid abrupt temperature transients and gradients across the sensor s package. Point the sensor in the downstream direction (facing front of tire) to avoid contamination, pitting, and/or destruction of the sensor s lens from debris. Protective windows are available upon request. The effective emissivity of most tires ranges from approximately 0.75 to 0.90 in the 8 to 14 µm spectrum. o Generally, the emissivity should be lowered as the standoff distance (distance from tire to sensor) increases; this is particularly important with the 60 FOV sensor due to the larger standoff distances required. The suggested emissivity vs. standoff distance is shown in the graph below: 1 0.95 Emissivity, ε 0.9 0.85 0.8 0.75 0.7 0 50 100 150 200 250 Standoff Distance (mm) o Lowering the emissivity increases the measured object temperature and vice versa Noise Equivalent Temperature Difference (NETD) increases with increasing sampling frequency: o Provided that tire surface temperature is highly transient, it is usually advantageous to use a higher sampling frequency at the cost of increased noise. A sampling frequency of 16 or 32 Hz is recommended for most applications. Page 9 of 9