á233ñ ELEMENTAL IMPURITIES PROCEDURES

Similar documents
PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009]

Pharmacopeial Forum Vol. 36(1) [Jan. Feb. 2010] 1

Using cold vapor generation atomic absorption to determine mercury impurities in pharmaceutical products

BRIEFING 1730 THEORY AND PRACTICE OUTLINE

Concept of Elemental Impurities (EI) assessment in finished dosage forms by total extraction testing

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

Test Method: CPSC-CH-E

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

Elemental Scientific. Spike Recovery. Elemental Scientific

Examples of Method Validation Studies Conducted in Different Economies

Elemental Scientific. Stability. Elemental Scientific

Validating performance of an Agilent 7800 ICP MS for USP <232>/<233> & ICH Q3D/Q2(R1): Elemental Impurity Analysis in Pharmaceuticals

Revision Bulletin 27 Jan Feb 2017 Non-Botanical Dietary Supplements Compliance

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

Revision Bulletin 29 Dec Jan 2018 Non-Botanical Dietary Supplements Compliance

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

Elemental Scientific. Spike Recovery. Elemental Scientific

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

Appendix II- Bioanalytical Method Development and Validation

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

Title Revision No date DETERMINATION OF HEAVY METALS (ARSENIC, CADMIUM, LEAD AND MERCURY) IN COSMETIC PRODUCTS

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

Analysis of trace elements in polymer samples to ensure compliance with WEEE-RoHS standards using the Thermo Scientific icap 7200 ICP-OES

Mercury, total-in-sediment, atomic absorption spectrophotometry, nameless, direct

February 20, Joe Cerniglia The International Group for Historic Aircraft Recovery (TIGHAR) Job Number: S0CHG688. Dear Joe:

Determining Elemental Impurities in Pharmaceutical Materials: How to Choose the Right Technique

DRAFT EAST AFRICAN STANDARD

á733ñ LOSS ON IGNITION

The Nitrofurantoin Capsules Revision Bulletin supersedes the currently official monograph.

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

Chapter 4: Verification of compendial methods

NATIONAL ASSOCIATION OF TESTING AUTHORITIES (NATA) REQUIREMENTS FOR ACCREDITATION OF ICP-MS TECHNIQUES

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

ASEAN GUIDELINES FOR VALIDATION OF ANALYTICAL PROCEDURES

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Accurate Quantification of Cadmium, Chromium, Mercury and Lead in Plastics for RoHS Compliance using the Agilent 7500ce ICP-MS

Quality Assurance is what we do to get the right answer for our purpose FITNESS FOR PURPOSE

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

U.S. EPA SW-846 Method 6010C using the Prodigy High Dispersion ICP

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Proposed new USP general chapters <232> and <233> for elemental impurities: The application of ICP-MS for pharmaceutical analysis

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

Basic Digestion Principles

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C

á191ñ IDENTIFICATION TESTS GENERAL

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

Meeting the Challenges of Soil Analysis with the Avio 200 ICP-OES

RISK ASSESSMENT, IMPLEMENTATION AND VALIDATION OF ELEMENTAL IMPURITIES FOR ICH Q3D, USP <232><233> AND EP 5.20

Handbook of Inductively Coupled Plasma Spectrometry

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

DISCLAIMER: This method:

The Isosorbide Mononitrate Extended-Release Tablets Revision Bulletin supersedes the currently official monograph.

Direct Analysis of Photoresist Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Application

contents of the currently official monograph. Please refer to the current edition of the USP NF for official text.

Traceability, validation and measurement uncertainty 3 pillars for quality of measurement results. David MILDE

PQRI Technical Analytical Challenges Round 2 Interlaboratory Study: Progress and Early Findings

BRIEFING. (EXC: K. Moore.) RTS C Propylparaben C 10 H 12 O Benzoic acid, 4 hydroxy, propyl ester; Propyl p hydroxybenzoate [ ].

Additionally, minor editorial changes have been made to update the monograph to current USP style.

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

PRINCIPLE OF ICP- AES

Trace elemental analysis solutions for your application. June 6, 2018

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Should you have any questions, please contact Mary P. Koleck, Ph.D., Scientific Liaison ( or

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

METHOD 8000A GAS CHROMATOGRAPHY

Z/zs. tnitiats: wu\ Z-z* I A. sop-c-102. Determination of Chemical Oxygen Demand. Revision 6. Approval: Effective date: 3. Renewat date: 7lt:,:

ICP-OES Application Note Number 35

Certificate of Analysis

Analytical Method Determination of airborne metal concentrations by ICP-MS Sampling using Solu-Sert filter capsules

Application note. Determination of exchangeable cations in soil extracts using the Agilent 4100 Microwave Plasma-Atomic Emission Spectrometer

Determination of Nutrients. Determination of total phosphorus. Extraktion with aqua regia, reflux method. Introduction

3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement

METHOD 3015A MICROWAVE ASSISTED ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS

Preparation of Food and Feed Samples for Metals Analysis

1. Preliminary qualitative analysis of unknown substances (liquid or solid).

Direct Determination of Cadmium and Lead in honey by Electrothermal Atomization Atomic Absorption Spectrometry with Zeeman Effect Correction

Sodium Chloride - Analytical Standard

USP 35 Official Monographs / Oxaliplatin 4143 DEFINITION

Dissolution Test 2 was validated using an Inertsil ODS-3V brand of L1 column. The typical retention time for donepezil is about 5.5 min.

Isotope Dilution Mass Spectrometry

METHOD 6010A INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION SPECTROSCOPY

SECTION D.2 AMMONIA NITROGEN

contents of the currently official monograph. Please refer to the current edition of the USP NF for official text.

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Debjani Banerjee Department of Chemical Engineering IIT Kanpur

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

ICH Q3D: Practical implementation and the role of excipient data in a risk based approach. Dr Andrew Teasdale

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

Transcription:

Second Supplement to USP 38 NF 33 Chemical Tests / á233ñ Elemental Impurities Procedures 1 á233ñ ELEMENTAL IMPURITIES PROCEDURES INTRODUCTION This chapter describes two analytical procedures (Procedures 1 and 2) for the evaluation of the levels of the elemental impurities. The chapter also describes criteria for acceptable alternative procedures. 2S (USP38) By means of validation 2S (USP38) studies, analysts will confirm that the analytical procedures described herein 2S (USP38) are suitable for use on specified material. Use of Alternative Procedures The chapter also describes criteria for acceptable alternative procedures. Alternative procedures that meet the validation requirements herein may be used in accordance with General Notices and Requirements 6.30, Alternative and Harmonized Methods and Procedures. Information on the Requirements for Alternate Procedure Validation is provided later in this chapter. 2S (USP38) Speciation The determination of the oxidation state, organic complex, or combination is termed speciation. Analytical procedures for speciation are not included in this chapter, but examples may be found elsewhere in USP NF and in the literature. COMPENDIAL PROCEDURES 1 AND 2 System standardization and suitability evaluation using applicable reference materials should be performed on the day of analysis. 2S (USP38) Procedure and Detection Technique Procedure 1 can be used for elemental impurities generally amenable to detection by inductively coupled plasma atomic (optical) emission spectroscopy (ICP AES or ICP OES). Procedure 2 can be used for elemental impurities generally amenable to detection by ICP MS. Before initial use, the analyst should verify that the procedure is appropriate for the instrument and sample used (procedural verification) by meeting the alternative procedure validation requirements below. Sample Preparation Forms of sample preparation include Neat, Direct aqueous solution, Direct organic solution, and Indirect solution. The selection of the appropriate sample preparation depends on the material under test and is the responsibility of the analyst. When a sample preparation is not indicated in the monograph, an analyst may use any of the following appropriately validated 2S (USP38) preparation procedures. In cases where spiking of a material under test is necessary to provide an acceptable signal intensity, the blank should be spiked with the same Target elements, and where possible, using the same spiking solution. Standard solutions may contain multiple Target elements. [NOTE All liquid samples should be weighed.] Neat: Used for liquids or alternative procedures that allow the examination of unsolvated samples. Direct aqueous solution: Used when the sample is soluble in an aqueous solvent. Direct organic solution: Used where the sample is soluble in an organic solvent. Indirect solution: Used when a material is not directly soluble in aqueous or organic solvents. Total metal extraction is the preferred sample preparation approach to obtain an indirect solution. 2S (USP38) Digest the sample using the 2S (USP38) Closed vessel digestion procedure provided below or one 2S (USP38) similar to it. 2S (USP38) The sample preparation scheme should yield sufficient sample to allow quantification of each element at the limit specified in the corresponding monograph or chapter. Closed vessel digestion: This sample preparation procedure is designed for samples that must be digested in a Concentrated acid using a closed vessel digestion apparatus. Closed vessel digestion minimizes the loss of volatile impurities. The choice of a Concentrated acid depends on the sample matrix. The use of any of the Concentrated acids may be appropriate, but each introduces inherent safety risks. Therefore, appropriate safety precautions should be used at all times. [NOTE Weights and volumes provided may be adjusted to meet the requirements of the digestion apparatus used.] An example procedure that has been shown to have broad applicability is the following. Dehydrate and predigest 0.5 g of primary sample in 5 ml of freshly prepared Concentrated acid. Allow to sit loosely covered for 30 min in a fume hood. Add an additional 10 ml of Concentrated acid, and digest, using a closed vessel technique, until digestion or extraction is complete.

2 á233ñ Elemental Impurities Procedures / Chemical Tests Second Supplement to USP 38 NF 33 Repeat, if necessary, by adding an additional 5 ml of Concentrated acid. [NOTE Where closed vessel digestion is necessary, follow the manufacturer s recommended procedures to ensure safe use.] Alternatively, leachate extraction may be appropriate with justification following scientifically validated metal disposition studies, which may include animal studies, speciation, or other means of studying disposition of the specific metal in the drug product. 2S (USP38) Reagents: All reagents used for the preparation of sample and standard solutions should be free of elemental impurities, in accordance with Plasma Spectrochemistry á730ñ. Procedure 1: ICP OES 2S (USP38) Standardization solution 1: 1.5 2S (USP38) J of the Target element(s) in a Matched matrix Standardization solution 2: 0.5J of the Target element(s) in a Matched matrix Sample stock solution: Proceed as directed in Sample Preparation above. Allow the sample to cool, if necessary. For mercury determination, add an appropriate stabilizer. Sample solution: Dilute the Sample stock solution with an appropriate solvent to obtain a final concentration of the Target elements at NMT 1.5 2S (USP38) J. Blank: Matched matrix Elemental spectrometric system (See Plasma Spectrochemistry á730ñ.) Mode: ICP Detector: Optical detection system Rinse: Diluent used Standardization: Standardization solution 1, Standardization solution 2, and Blank System suitability Sample: Standardization solution 1 Suitability requirements Drift: Compare results obtained from Standardization solution 1 before and after the analysis of the Sample solution. Suitability criteria: NMT 20% for each Target element. [NOTE If samples are high in mineral content, rinse system well 2S (USP38) before introducing the Sample in order to minimize carryover.] Analysis: Analyze according to the manufacturer's suggestions for program and wavelength. Calculate and report results on the basis of the original sample size. [NOTE Appropriate measures must be taken to correct for matrix-induced interferences (e.g., wavelength overlaps).] Procedure 2: ICP MS Standardization solution 1: 1.5 2S (USP38) J of the Target element(s) in a Matched matrix Standardization solution 2: 0.5J of the Target element(s) in a Matched matrix Sample stock solution: Proceed as directed for Sample Preparation above. Allow the sample to cool, if necessary. For mercury determination, add an appropriate stabilizer. Sample solution: Dilute the Sample stock solution with an appropriate solvent to obtain a final concentration of the Target elements at NMT 1.5 2S (USP38) J. Blank: Matched matrix Elemental spectrometric system (See Plasma Spectrochemistry á730ñ.) Mode: ICP. [NOTE An instrument with a cooled spray chamber is recommended. (A collision cell or reaction cell may also be beneficial.)] Detector: Mass spectrometer Rinse: Diluent used Standardization: Standardization solution 1, Standardization solution 2, and Blank System suitability Sample: Standardization solution 1 Suitability requirements Drift: Compare results obtained from Standardization solution 1 before and after the analysis of the Sample solution. Suitability criteria: Drift NMT 20% for each Target element. [NOTE If samples are high in mineral content, rinse system well 2S (USP38) before introducing the Sample in order to minimize carryover.] Analysis: Analyze according to the manufacturer's suggestions for program and m/z. Calculate and report results based on the original sample size. [NOTE Appropriate measures must be taken to correct for matrix-induced interferences (e.g., argon chloride interference with arsenic determinations).]

Second Supplement to USP 38 NF 33 Chemical Tests / á233ñ Elemental Impurities Procedures 3 REQUIREMENTS FOR 2S (USP38) ALTERNATE PROCEDURE VALIDATION If the specified compendial procedures do not meet the needs of a specific application, an alternative procedure may be developed (see General Notices and Requirements 6.30, Alternative and Harmonized Methods and Procedures). Alternative procedures must be validated and shown to be acceptable, in accordance with the validation requirements for alternative procedures as described below. 2S (USP38) The level of validation necessary to ensure that an alternative procedure is acceptable depends on whether a limit test or a quantitative determination is specified in the monograph. 2S (USP38) The requirements for the validation of an elemental impurities procedure for each 2S (USP38) type of determination are described below. Any alternative procedure that has been validated and meets the acceptance criteria that follow is considered to be suitable for use. 2S (USP38) LIMIT PROCEDURES The following section defines the validation parameters for the acceptability of alternative limit procedures. Meeting these requirements must be demonstrated experimentally using an appropriate system suitability procedure and reference material. 2S (USP38) The suitability of the method must be determined by conducting studies with the material or mixture under test supplemented with known concentrations of each Target element of interest at the appropriate acceptance limit concentration. The material or mixture under test must be spiked before any sample preparation steps are performed. Detectability Standard solution: A preparation of reference materials for the Target element(s) at the Target concentration Spiked sample solution 1: Prepare a solution of sample under test, spiked with appropriate reference materials for the Target elements at the Target concentration, solubilized or digested as described in Sample Preparation. Spiked sample solution 2: Prepare a solution of the sample under test, spiked with appropriate reference materials at 80% of the Target concentration for the Target elements, solubilized or digested as described in Sample Preparation. Unspiked sample solution: A sample of material under test, solubilized or digested in the same manner as the Sample solutions Non-instrumental procedures: Spiked sample solution 1 provides a signal or intensity equivalent to or greater than that of the Standard solution. Spiked sample solution 2 must provide a signal or intensity less than that of Spiked sample solution 1. [NOTE The signal from each Spiked sample solution is NLT the Unspiked sample solution determination.] Instrumental procedures: The average value of the three replicate measurements of Spiked sample solution 1 is within ±15% of the average value obtained for the replicate measurements of the Standard solution. The average value of the replicate measurements of Spiked sample solution 2 must provide a signal intensity or value less than that of the Standard solution. [NOTE Correct the values obtained for each of the spiked solutions using the Unspiked sample solution.] Precision for Instrumental Methods (Repeatability) [NOTE Non-instrumental precision is demonstrated by meeting the Detectability requirement above.] Sample solutions: Six independent samples of the material under test, spiked with appropriate reference materials for the Target elements at the Target concentration Relative standard deviation: NMT 20% for each Target element Specificity The procedure must be able to unequivocally assess (see Validation of Compendial Procedures á1225ñ) each Target element in the presence of components that may be expected to be present, including other Target elements, and matrix components. QUANTITATIVE PROCEDURES The following section defines the validation parameters for the acceptability of alternative quantitative procedures. Meeting these requirements must be demonstrated experimentally, using an appropriate system suitability procedure and reference

4 á233ñ Elemental Impurities Procedures / Chemical Tests Second Supplement to USP 38 NF 33 materials. Meeting these requirements demonstrates that the procedure is equivalent to the compendial procedure for the purpose of quantifying the Target elements. Accuracy Standard solutions: Prepare solutions containing the Target elements at concentrations ranging from 50% to 150% of J, using appropriate reference materials. Test samples: Prepare samples of the material under test spiked with appropriate reference materials before any sample preparation steps (digestion or solubilization) at concentrations ranging from 50% to 150% of J for each Target element. Spike recovery: 70% 150% for the mean of three replicate preparations at each concentration Precision REPEATABILITY Test samples: Six independent samples of material under test (taken from the same lot) spiked with appropriate reference materials for the Target element(s) at the indicated level Relative standard deviation: NMT 20% (N = 6) 2S (USP38) for each Target element INTERMEDIATE PRECISION ( 2S (USP38) RUGGEDNESS ) 2S (USP38) Perform the Repeatability analysis again either on a different day, with a different instrumentation, with a different analyst, or a combination thereof. Combine the results of this analysis with the Repeatability analysis so the total number of analyses is 12. 2S (USP38) Relative standard deviation: NMT 25% (N = 12) 2S (USP38) for each Target element Specificity The procedure must be able to unequivocally assess (see á1225ñ) each Target element in the presence of components that may be expected to be present, including other Target elements, and matrix components. Demonstrated by meeting the Accuracy requirement. Limit of Quantitation, Range, and Linearity APPENDIX Concentrated acid: Concentrated ultra-pure nitric, sulfuric, hydrochloric, or hydrofluoric acids or Aqua regia Aqua regia: Aqua regia is a mixture of concentrated hydrochloric and nitric acids, typically at ratios of 3:1 or 4:1, respectively. Matched matrix: Solutions having the same solvent composition as the Sample solution. In the case of an aqueous solution, Matched matrix would indicate that the same acids, acid concentrations, and mercury stabilizer are used in both preparations. Target elements: Elements with the potential of being present in the material under test. Include arsenic (As), cadmium (Cd), lead (Pb), and mercury (Hg) in the target element evaluation when testing is done to demonstrate compliance. Target elements should also include any elements that may be added through material processing or storage. 2S (USP38) Target limit or Target concentration: The acceptance value for the elemental impurity being evaluated. Exceeding the Target limit indicates that a material under test exceeds the acceptable value. The determination of compliance is addressed in other chapters. [NOTE When applying this chapter to Elemental Impurities Limits á232ñ and Elemental Contaminants in Dietary Supplements á2232ñ, Target limits can be approximated by dividing the Daily Dose PDEs by the maximum daily dose for the Drug Product Analysis Option in á232ñ or the Daily Serving PDE divided by the maximum daily serving size in á2232ñ.] J: The concentration (w/w) of the element(s) of interest at the Target limit, appropriately diluted to the working range of the instrument. For example, if the target elements are lead and arsenic for an analysis of an oral solid drug product with a daily dose of 10 g/day using inductively coupled plasma mass spectrometry (ICP MS), the target limit for these elements would be 0.5 mg/g and 1.5 2S (USP38) mg/g (see Table 2 in á232ñ). However, in this case, the linear dynamic range of the ICP MS is known to extend from 0.01 ng/ml to 0.1 mg/ml for these elements. Therefore, a dilution factor of at least 1:100 2S (USP38) is

Second Supplement to USP 38 NF 33 Chemical Tests / á233ñ Elemental Impurities Procedures 5 required to ensure that the analysis occurs in the linear dynamic range of the instrument. J would thus equal 5 ng 2S (USP38) and 15 ng 2S (USP38) /ml for lead and arsenic, respectively, when the dilution factor is added. Appropriate reference materials: Where Appropriate reference materials are specified in the chapter, certified reference materials (CRM) from a national metrology institute (NMI), or reference materials that are traceable to the CRM of an NMI should be used. An example of an NMI in the United States is the National Institute of Standards and Technology.