A Comparison of Least Squares Linear Regression and Measurement Error Modeling of WadCold Multipole Correlation in SSC Prototype Dipole Magnets

Similar documents
Bulk Modulus Capacitor Load Cells

Constant of Motion for a One- Dimensional and nth-order Autonomous System and Its Relation to the Lagrangian and Hamiltonian

(4) How do you develop an optimal signal detection technique from the knowledge of

8STATISTICAL ANALYSIS OF HIGH EXPLOSIVE DETONATION DATA. Beckman, Fernandez, Ramsay, and Wendelberger DRAFT 5/10/98 1.

PROJECT PROGRESS REPORT (03/lfi?lfibr-~/15/1998):

+.V) eo(o) -2 so - sx. hngc)90w3-- Beam-beam collisions and crossing angles in RHIC*

Tell uric prof i 1 es across the Darrough Known Geothermal Resource Area, Nevada. Harold Kaufniann. Open-file Report No.

N. Tsoupas, E. Rodger, J. Claus, H.W. Foelsche, and P. Wanderer Brookhaven National Laboratory Associated Universities, Inc. Upton, New York 11973

GA A22677 THERMAL ANALYSIS AND TESTING FOR DIII D OHMIC HEATING COIL

UNDERSTANDING TRANSPORT THROUGH DIMENSIONLESS PARAMETER SCALING EXPERIMENTS

RESEARCH IN ACCELERATOR PHYSICS (THEORY)

Plasma Response Control Using Advanced Feedback Techniques

GA A23736 EFFECTS OF CROSS-SECTION SHAPE ON L MODE AND H MODE ENERGY TRANSPORT

AC dipole based optics measurement and correction at RHIC

PLASMA MASS DENSITY, SPECIES MIX AND FLUCTUATION DIAGNOSTICS USING FAST ALFVEN WAVE

CQNl_" RESPONSE TO 100% INTERNAL QUANTUM EFFICIENCY SILICON PHOTODIODES TO LOW ENERGY ELECTRONS AND IONS

Curvature of a Cantilever Beam Subjected to an Equi-Biaxial Bending Moment. P. Krulevitch G. C. Johnson

Three-Dimensional Silicon Photonic Crystals

GA A22689 SLOW LINER FUSION

GA A27857 IMPACT OF PLASMA RESPONSE ON RMP ELM SUPPRESSION IN DIII-D

GA A25853 FAST ION REDISTRIBUTION AND IMPLICATIONS FOR THE HYBRID REGIME

Contractor Name and Address: Oxy USA, Inc. (Oxy), Midland, Texas OBJECTIVES

Development of a High Intensity EBIT for Basic and Applied Science

4kU. Measurement of Storage Ring Motion at the Advanced Light Source. QSTt ERNESTORLANDO LAWRENCE BERKELEYNATIONAL LABORATORY

GA A27806 TURBULENCE BEHAVIOR AND TRANSPORT RESPONSE APPROACHING BURNING PLASMA RELEVANT PARAMETERS

Colliding Crystalline Beams

GA A23713 RECENT ECCD EXPERIMENTAL STUDIES ON DIII D

Scaling between K+ and proton production in nucleus-nucleus collisions *

GA A27805 EXPANDING THE PHYSICS BASIS OF THE BASELINE Q=10 SCENRAIO TOWARD ITER CONDITIONS

D. L. Strenge PNL-SA A GENERAL ALGORITHM FOR RADIOACTIVE DECAY WITH BRANCHING AND LOSS FROM A MEDIUM DISCLAIMER. July 1995

Quarterly Report April 1 - June 30, By: Shirley P. Dutton. Work Performed Under Contract No.: DE-FC22-95BC14936

ust/ aphysics Division, Argonne National Laboratory, Argonne, Illinois 60439, USA

DML and Foil Measurements of ETA Beam Radius

Flowing Interval Spacing Parameter for Matrix Diffusion in the Saturated Zone

GA A26474 SYNERGY IN TWO-FREQUENCY FAST WAVE CYCLOTRON HARMONIC ABSORPTION IN DIII-D

DE '! N0V ?

Comparison Between Various Beam Steering Algorithms for the CEBAF Lattice* INTRODUCTION. SVD Based Algorithm

A NEW TARGET CONCEPT FOR PROTON ACCELERATOR DRIVEN BORON NEUTRON CAPTURE THERAPY APPLICATIONS* Brookhaven National Laboratory. P.O.

INTERMOLECULAR POTENTIAL FUNCTIONS AND HIGH RESOLUTION MOLECULAR SPECTROSCOPY OF WEAKLY BOUND COMPLEXES. Final Progress Report

GA A26057 DEMONSTRATION OF ITER OPERATIONAL SCENARIOS ON DIII-D

Comments on the Geophysics paper Multiparameter 11norm. waveform fitting: Interpretation of Gulf of Mexico reflection

Peak Reliability Delivering near real-time phase angle deltas using Inter-Control Center Communication Protocol (ICCP)

RWM FEEDBACK STABILIZATION IN DIII D: EXPERIMENT-THEORY COMPARISONS AND IMPLICATIONS FOR ITER

Magnetic Measurements of the Elliptical Multipole Wiggler Prototype

BASAL CAMBRIAN BASELINE GEOLOGICAL CHARACTERIZATION COMPLETED

National Accelerator Laboratory

Quench Propagation Velocity for Highly Stabilized Conductors

RECEIVED SEQ

W. Fischer and M. Okamura Brookhaven National Laboratory, Upton, NY 11973, USA

PROJECT PROGRESS REPORT (06/16/1998-9/15/1998):

Application of a Three-Dimensional Prognostic Model During the ETEX Real-Time Modeling Exercise: Evaluatin of Results (u)

August 3,1999. Stiffness and Strength Properties for Basic Sandwich Material Core Types UCRL-JC B. Kim, R.M. Christensen.

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

1995 Particle Accelerator Conference and International Conference on High-Energy Accelerators

Multi-Scale Chemical Process Modeling with Bayesian Nonparametric Regression

National Accelerator Laboratory

Scaling of divertor heat flux profile widths in DIII-D

Clifford K. Ho and Michael L. Wilson Sandia National Laboratories. P.O. Box Albuquerque, NM

Richard F. Gunst and William R. Schucany Department of Statistical Science Southern Methodist University Dallas, Texas 75275

Plutonium 239 Equivalency Calculations

GA A26686 FAST ION EFFECTS DURING TEST BLANKET MODULE SIMULATION EXPERIMENTS IN DIII-D

MAGNETIC RESONANCE IMAGING OF SOLVENT TRANSPORT IN POLYMER NETWORKS

A Distributed Radiator, Heavy Ion Driven Inertial Confinement Fusion Target with Realistic, Multibeam Illumination Geometry

GA A24166 SUPER-INTENSE QUASI-NEUTRAL PROTON BEAMS INTERACTING WITH PLASMA: A NUMERICAL INVESTIGATION

Undulator Interruption in

Applications of Pulse Shape Analysis to HPGe Gamma-Ray Detectors

National Accelerator Laboratory

RUDOLPH J. HENNINGER, XHM PAUL J. MAUDLIN, T-3 ERIC N. HARSTAD, T-3

Start-up Noise in 3-D Self-AmpMed

Simulation of Double-Null Divertor Plasmas with the UEDGE Code

Optimization of NSLS-II Blade X-ray Beam Position Monitors: from Photoemission type to Diamond Detector. P. Ilinski

Modeling Laser and e-beam Generated Plasma-Plume Experiments Using LASNEX

Measurement of Low Levels of Alpha in 99M0Product Solutions

C o f l F - 9m307-- SPREADSHEET APPLICATION TO CLASSIFY RADIOACTIVE MATERIAL FOR SHIPMENTa. A. N. Brown

RECXWH2 W/o s3-1

Abstract. results that address this question for the main linacs of the NLC. We will show that the effects of alignment drifts can indeed be handled.

m w n? r i OF,THISDOCUMENT IS UNLIMITED

Analysis of Shane Telescope Aberration and After Collimation

PROCEEDINGS THIRD WORKSHOP GEOTHERMAL RESERVOIR ENGINEERING. December 14-15,1977

GA A27235 EULERIAN SIMULATIONS OF NEOCLASSICAL FLOWS AND TRANSPORT IN THE TOKAMAK PLASMA EDGE AND OUTER CORE

Los Alamos IMPROVED INTRA-SPECIES COLLISION MODELS FOR PIC SIMULATIONS. Michael E. Jones, XPA Don S. Lemons, XPA & Bethel College Dan Winske, XPA

Bandgap Photons to GaInP2

GA A23977 DETAILED MEASUREMENTS OF ECCD EFFICIENCY ON DIII D FOR COMPARISON WITH THEORY

Survey, Alignment and Beam Stability at the Advanced Light Source

GA A22722 CENTRAL THOMSON SCATTERING UPGRADE ON DIII D

UPGRADED CALIBRATIONS OF THE THOMSON SYSTEM AT DIII D

Multicusp Sources for Ion Beam Lithography Applications

A Few-Group Delayed Neutron Model Based on a Consistent Set of Decay Constants. Joann M. Campbell Gregory D. Spriggs

IMPACT OF EDGE CURRENT DENSITY AND PRESSURE GRADIENT ON THE STABILITY OF DIII-D HIGH PERFORMANCE DISCHARGES

Two-Screen Method for Determining Electron Beam Energy and Deflection from Laser Wakefield Acceleration

The Radiological Hazard of Plutonium Isotopes and Specific Plutonium Mixtures

Diffractive Dijet Search with Roman Pots at CDF

AlliedSianal. Measurement U ncertai n ty of Silicone Fluid Leakage Testing for Rolamites. W. E. Holland. Federal Manufacturing & Technologies

12/16/95-3/15/96 PERIOD MULTI-PARAMETER ON-LINE COAL BULK ANALYSIS. 2, 1. Thermal Neutron Flux in Coal: New Coal Container Geometry

Summary Report: Working Group 5 on Electron Beam-Driven Plasma and Structure Based Acceleration Concepts

Turbulent Scaling in Fluids. Robert Ecke, MST-10 Ning Li, MST-10 Shi-Yi Li, T-13 Yuanming Liu, MST-10

Lawrence Berkeley Laboratory UNIVERSITY OF CALIFORNIA

TARGET PLATE CONDITIONS DURING STOCHASTIC BOUNDARY OPERATION ON DIII D

DISCLAIMER BASIN, WEST TEXAS AND NEW MEXICO

LABORATORY MEASUREMENT OF PERMEABILITY UPSCALING:- R FOR THE TOPOPAH SPRING MEMBER OF THE PAINTBRUSH TUFF

Transcription:

SSCL-Preprint-291 May 1993 Distribution Category: 400 A Comparison of Least Squares Linear Regression and Measurement Error Modeling of WadCold Multipole Correlation in SSC Prototype Dipole Magnets D. Pollock R. Gunst K. Kim W, Schucany t Superconducting Super Collider Laboratory P

I Disclaimer Notice This report was prepared as an account of work sponsored by an agency of the United States Government. NeIher the UnIed States Government or any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed,or represents that its use would not infringe privalely owned rights. Referenceherein to any specific commercialproduct, process, or service by trade name. trademark, manufacturer.or otherwise. does not necessarilywxstiute or imply Is endorsement, recommendation,or favoring by the United States Government or any agency thereof. The views and winions of authors expressed herein do not necessarilyslate or reflect those of the UnIed States Governmentor any agency mereof. Superconducting Super Collider Laboratory is an equal opportunity employer.

DISCLAIMER Portions of this document may be illegible in electronic image products. Images are produced from the best available original document.

To be published in Supercollider 5 SSCL-Preprint-29 1 A Comparison of Least Squares Linear Regression and Measurement Error Modeling of Wardcold Multipole Correlation in SSC Prototype Dipole Magnets* D. Pollock and K. Kim Superconducting Super Collider Laboratory? 2550 BecMeymeade Ave. Dallas, TX 75237 R. Gunst and W. Schucany Southern Methodist University Dallas, TX 75275 May 1993 *Presented at the Fifth Annual International Symposium on the Super Collider, May 68,1993 San Francisco, CA. +Operated by the Universities Research Association, Inc., for the U.S. Department of Energy under Contract NO. DE-AC35-89ER40486.

A COMPARISON OF LEAST SQUARES LINEAR REGRESSION AND MEASUREMENT ERROR MODELING OF WARM / COLD MULTIPOLE CORRELATION IN SSC PROTOTYPE DIPOLE MAGNETS D. A. Pollock,l R. F. Gunst? K. Kim,l and W. R. Schucany' Superconducting Super Collider Laboratory, Dallas, Texas 75237* 'Southern Methodist University, Dallas,Texas 75275 INTRODUCTION Linear estimation of cold magnetic field quality based on warm multipole measurements is being considered as a quality control method for SSC production magnet acceptance. To investigate prediction uncertainties associated with such an approach, axial-scan (2-scan) magnetic measurements from S SC Prototype Collider Dipole Magnets (CDMs) have been studied. This paper presents a preliminary evaluation of the explanatory ability of warm measurement multipole variation on the prediction of cold magnet multipoles. Two linear estimation methods are presented: least-squares regression, which uses the assumption offxed independent variable (xi) observations, and the measurement error model, which includes measurement error in the xi's. The influence of warm multipole measurement errors on predicted cold magnet multipole averages is considered. MSD QA is studying warm/cold correlation to answer several magnet quality control questions. How well do warm measurements predict cold (2kA) multipoles? Does samphg error significantly influence estimates of the linear coefficients (slope, intercept and residual standard error)? Is estimation error for the predicted cold magnet average small compared to typical variation along the 2-Axis? What fraction of the multipole RMS tolerance is accounted for by individual magnet prediction uncertainty? THE DATA To compare the two linear estimation models, the joint behavior of warm/cold multipole pairs have been studied. The data selected is from six CDM's (DCA311, 3 12, 314, 315, 317, and 319) which were measured at FNAL using mole B2. The data includes multipoles (an and bn, n = 1,ll) which were measured at 24 2-scan positions (between -7.01 and 7.01 m) for each magnet under both cold (2kA) and warm (+/- 10 A) conditions. The reported values are the position average of repetitive coil rotations. Also, the measurements have been centering corrected. Traditional linear regression assumptions regarding independence, constant variance and normality have been verified for the source data using graphical residual analysis techniques.1 Research results for the b2 (normal sextupole) multipole will be demonstrated in this paper. *Operated by the Universities Research Association, Inc., for the U.S. Department of Energy under Contract NO. DE-AC35-89ER40486.

COMPARING ORDINARY LEAST SQUARES AND MEASUREMENT ERROR MODEL FITS Ordinary Least Squares (OLS) is typically used to estimate the relationship between paired observations for which y is assumed to be linearly dependent on or explained by x. For the Warm/Cold multipole study, yi is a cold multipole observation (mole-position average), x i is a warm multipole observation. The dependent variable is traditionally assumed to be "fixed", (Le., observed without error). Since the Warm observations are not fixed (Le., each individual coil rotation at a given mole-position generates a different result), the OLS prediction model is subject to both random and measurement errors. According to linear estimation theory, the predicted slope, intercept and residual standard error using the OLS model under such conditions will be biased.*. 3 Without adjusting for the measurement error, the cold prediction model will underestimate the slope. In the case that x and y are themselves random variables (Le., error-free cold and warm multipole measurements are each random variables based on samples from several coil-rotations) the traditional linear model assumptions should be replaced by a Measurement Error Model.3 The key to applying the measurement error model (MEM) to cold multipole predictions is determining the value of the ratio of error variances (A) which for our example is defined as the ratio of (variance cold) / (variance warm). To estimate h, sample variance for both warm and cold multipoles by position (using individual coil rotations) within individual magnets have been calculated. The position variance estimate has been calculated as the average of individual position variances for all Z-scan positions and available magnets. Outliers were removed by using the Shewhart Variance Control Chart. Extreme values due to magnet end effects and strain gauge packs were also removed. The estimated h for the b2 data is 0.000392 units. It should be noted that a recent upgrade to the SSCL magnetic measuring system has reduced warm position variance significantly. The data in this study are for measurements taken before the improvement was introduced. P b 2.0 CI r 1.S X -aa I C 1.o Y cy n 9 0 0.5 0 -v.u 1.o 1.5 2.0 2.5 1 3.0 WARM b2 (unit8 X 10^-4) Figure Warm vs. Cold b2. The linear fits using OLS (shallower slope) and MEM (steeper slope) mel.ods. Data does not include strain gauge position values. A comparison of OLS and MEM prediction equations for b2 is shown in Figure 1. The figure shows how the OLS estimate tends to under-estimate the slope. The estimated coefficients (slope, intercept and residual standard error) and a 95% prediction interval for both OLS and MEM models of individual mole-position estimates are listed in Table 1. The wider 95% prediction interval for the MEM estimate shown in Table 1 is due to including measurement error (A). I

Table 1. Comparing OLS and MEM Estimates of Cold b2 by Mole-Position Estimate Slope Intercept Std. Error of Residuals OLS * 0.976 0.997 1.397 1.256-0.717-0.718-1.600 1.263 0.23319 0.18397 0.27892 0.20762 OLS ** MEM * MEM ** * ** - with "straingauge"effects. without "straingauge"effects. 95% Prediction Interval *** (1 sided, at mean warm value) 0.46023 0.36194 0.54875 0.40847 *** 95%prediction interval = 1.96 x Std. Error x sqrt(l/n + 1) Both the OLS and MEM prediction methods have been used to estimate cold multipoles by 2-position. See Figure 2 "Warm/Cold b2 Estimates by Mole-Position (DCA311)" for an example of the predictions by position. Based on One Way Analysis of Variance (ANOVA) of DCA311 warm multipole coil-rotation data, the average variance "within" position (i.e., due to measurement error) is 0.01482 units and the "between" postion variance is 0.12842 units. Differences due to position (i.e. manufacturing variation along the length of the magnet) explain approximately 92% of the variance in DCA311 warm b2. Similarly, differences due to position explain approximately 99%of the variance in DCA311 cold b2. In both cases, measurement error is very small compared to variation along the magnet. x YEN EST. (no S/G) OLS EST. (no W G ) + COLD b2 (PO8 AVG) 0 WARY b2 (PO8 AVQ) Figure 2. Warm/Cold 62 Estimate by Mole-Position (DCA311). Strain gauge effets are not shown. Predicted cold multipole values by mole-position are plotted using OLS and MEM methods. Actual Warm and Cold Measurements are shown for comparison. x YEYESX(noW0) om EST. (no %/a, 0 COLD b2 YAQNET AVQ + Figure 3. Warm/Cold b2 Estimate of Magnet Averages. Mole-position values have been averaged over the length of the magnet, without positions -0.31, and -1.52 (strain gauge effects). PREDICTING COLD MAGNET AVERAGE MULTIPOLE VALUES For magnet acceptance purposes, the magnet mean of the multipoles is of primary interest. The magnet mean is estimated as an average of the position measurements (or predictions). A summary of magnet mean predictions for b2 is presented in Figure 3 and Table 2. From these summaries, one may compare the relative difference between the Cold measurements and the OLS or MEM estimates. The MEM prediction was closer than the OLS prediction to the measured cold mean in 4/6 of the cases studied.

Table 2. Magnet Mean Results forb2 (normal sextupole). Note: Position o -0.31 m, -1.52 m (strain gauge effect removed), n = 22 positions per magnet. Bold indicates minimum prediction delta (absolute deifference from Cold Mean). Magnet DCA311 DCA312 DCA314 DCA315 DCA317 DCA319 Cold Mean OLS Mean Delta OLS h4emmean Delta MEM 0.99052 1.10590 0.11538 1.02881 0.03829 1.89581 1.47492 0.42089 1.49925 0.39656 1.69006 1.54623 0.14383 1.58910 0.10096 1.54929 1.67855 0.12926 1.75583 0.20654 1.08904 0.96566 0.12338 0.85753 0.23151 1.02556 1.21579 0.19023 1.17272 0.14716 DISCUSSION OF QUALITY CONTROL QUESTIONS PRESENTED IN THE INTRODUCTION 1. Using a linear model, how well do warm measurements predict cold (2kA) multipoles? For the example presented, the average absolute difference between six cold magnet averages of b 2 and predicted magnet averages is: 0.18716 units (OLS),and 0.18684 units (ML), see Table 2. 2. Does warm measurement sampling error significantly influence estimates of the linear coeflcients (slope, intercept and residual standard error)? Yes, at the "moleposition" level as demonstrated, see Table 1. 3. Is estimation error small compared to typical variation along the 2-Axis? Using the difference between the observed cold magnet average and the predicted magnet average, estimation error appears to be small. In this example the predicted magnet mean differed from the COLD measurement mean by 0.18716 units (OLS average absolute difference) and 0.18684 units (MEM), see Table 2. Using ANOVA of individual coilrotation data, measurement error was shown to be very small compared to variation along the magnet. 4. Whatfraction of the multipole tolerance (b2 RMS I.15, Systematic 2.0 at injection, 0.8 at high current) is accounted for by individual magnet prediction uncertatinty? Based on the average absolute difference between cold and predicted magnet means, OLS estimation error accounts for approximately 16.3 % of the b2 RMS tolerance and 23.40% of the high field b2 systematic tolerance, while MEM estimation error accounts for 16.2% of the RMS tolerance and 23.36%of the high field systematic tolerance. CONCLUSION This study has demonstrated two methods which may be considered for making cold magnet predictions from warm magnetic measurements. The study is based on a very small number of magnets. For the b2 example presented the two estimation methods produced similar predictions of the cold mean. Recent improvements to the measurement system may make the issue of "measurement error" insignificant. Uncertainty of the predicted mean due to magnet axial variation will continue to be studied as more magnets and data become available. ACKNOWLEDGMENTS A. Devred,J. DiMarco (SSCL, Dallas, Texas). K. Kussmaul (Westinghouse Elecmc Corporation, Round Rock,Texas). REFERENCES 1. 2. 3. 4. D. C. Montgomery (1991). Introduction to Statistical Quality Control, Second Edition, John Wiley & Sons, New York. pp. 465-468. J.D.Jobson (1991). Applied Multivariate Data Analysis. Volume I: Regression and Experimental Design, Springer-Verlag, New York. pp. 121, 122. M. Reilman, R. Gunst, and M. Lakshminarayana (1986). Stochastic Regression with Errors in Both Variables, Journal of Quality Technology, Vol. 18, No.3, pp. 162 ff. J. DiMarco, et. al., Magnetic Measurements, DCA320-322, MSIM Report, September 22,1992.